DE
Panasonic logo
Offizielle Bedienungsanleitung

Panasonic QA43K11GAU6

2 Seiten·62 KB·Kompressor·PDF·EN
Panasonic QA43K11GAU6
Inhaltsverzeichnis 2 Abschnitte MATSUSHITA Compressor Single Phase 115 V MODEL# QA43K11GAU6 R-134a 60 Hz · LR - 36593 LR - 100738 AnzeigenAusblenden
Page 1 of the Panasonic QA43K11GAU6 user manual — MATSUSHITA Compressor Single Phase 115 V MODEL# QA43K11GAU6 R-134a 60 Hz
Seite 1 · Zum Vergrößern klicken
Seite 1
Panasonic QA43K11GAU6 — MATSUSHITA Compressor Single Phase 115 V MODEL# QA43K11GAU6 R-134a 60 Hz diagram (page 1)
Abb. 1 · MATSUSHITA Compressor Single Phase 115 V MODEL# QA43…

MATSUSHITA Compressor Single Phase 115 V MODEL# QA43K11GAU6 R-134a 60 Hz

Voltage Range 103 Volts to 127 Volts @ 60 Hz Application High Back Pressure Compressor Cooling Fan Cooling

Refrigerant Control . . Capillary Tube Evaporator

Temp. Range 23°F to 59°F / -5°C to 15°C

Capacity 1,485 Btu/h ±10% * E.E.R 6.94 Btu/Wh ±10% * Current 2.62 Amps *

Panasonic QA43K11GAU6 — MATSUSHITA Compressor Single Phase 115 V MODEL# QA43K11GAU6 R-134a 60 Hz diagram (page 1)
Abb. 2 · MATSUSHITA Compressor Single Phase 115 V MODEL# QA43…

Nominal Motor Data Motor Input 214 Watts* Rated Current . . . 2.31 Amps Type RSIR, PTC relay

Locked Rotor 12.3 Amps Start Current 17.7 Amps Coil Resistances Run 2.93 Ohms @ 68°F (20°C) Start . . . 9.88 Ohms

*Test Conditions for Performance Specifications

Test Oil Freol α 22 Shell Temp 170.0°F / 76.0°C Condensing Temp 130.0°F / 54.4°C Evaporating Temp 45.0°F / 7.2°C Ambient Temp 95.0°F / 35.0°C Gas Superheat 95.0°F / 35.0°C Liquid Sub-Cooling 115.0°F / 46.1°C

Overload Protector Nominal Operating Characteristics

30 35 40 45 50 55 60 Evaporating Temperature (°F)

Model Name MM3-33EC Manufacturer Matsushita Temperature To Open: 230°F ± 9°F / 110°C ± 5°C

Close: 142°F ± 15°F / 61°C ± 8°C Trip Current @158°F (70°C) 3.3 Amps ± 7.5% @77°F (25°C) 10.0 Amps @ 18 sec. max. P.T.C. Starting Device Nominal Operating Characteristics Model Name MM8-5CDP4M7 PTH7M4R7MC1 Manufacturer Matsushita Murata Mfg. Base resistance @ 77°F(25°C) ±20% 4.7 4.7 Ohms Power Consumption (max) 4.0 3.0 Watts Operation time 1.5 to 3.5 0.7 to 2.2 seconds Recovery time (max) 85 70 seconds Run Capacitor — µF — V (min.) †Although these accessories are listed by UL/CSA for use with this compressor, Matsushita assumes no responsibility whatsoever for these or any other components sourced by the refrigeration system manufacturer from third parties.9 – Point Data Evaporating Temp. Condensing Temp. Rating +30°F +45°F +59°F 140°FBtu/h Watts Amps E.E.R.973 193 2.49 5.041,420 223 2.69 6.371,990 252 2.89 7.90 130°FBtu/h Watts Amps E.E.R.1,017 187 2.45 5.441,485 214 2.62 6.942,062 236 2.79 8.74 120°FBtu/h Watts Amps E.E.R.1,065 181 2.41 5.881,533 202 2.55 7.592,141 221 2.69 9.69 Panasonic® Panasonic Industrial Company Refrigeration Products Department Tel: 201 - 392 - 4249 Fax: 201 - 392 - 4315 Rev#1-5/9

Rated Performance Data · Performance Curves · Electrical Accessories†

Page 2 of the Panasonic QA43K11GAU6 user manual — LR - 36593 LR - 100738
Seite 2 · Zum Vergrößern klicken
Seite 2
Panasonic QA43K11GAU6 — LR - 36593 LR - 100738 diagram (page 2)
Abb. 3

MATSUSHITA Compressor Single Phase 115 V MODEL# QA43K11GAU6 R-134a 60 Hz

Tubes Tube O.D. Wall Material Suction 0.39 in. / 10 mm 0.035 in. / 0.9 mm Copper Process 0.39 in. / 10 mm 0.035 in. / 0.9 mm Copper Discharge 0.33 in. / 8.3 mm 0.035 in. / 0.9 mm Copper

mm inches A 188.8 7.43 B 73.0 2.87 C 115.8 4.56 D 77.0 3.03 E 62.2 2.45 F 77.0 3.03

U.L. File # SA 4615 C.S.A. File #’s LR - 34080

* All dimensions are for reference only

LR - 36593 LR - 100738

This document sets forth certain operational parameters and conditions for operation of this product. If this product is operated outside of the parameters and conditions stated herein, buyer assumes sole and full responsibility and shall indemnify seller with respect to all product failures and all consequences thereof. Operation of the product outside of the parameters and conditions specified herein shall serve to invalidate all seller warranties, if any, with respect to the product. This document is for reference only. For specifications, please contact Panasonic’s engineering department.

General Data Oil Charge . . 250 cc ± 5 cc / 15.3 cu.in. ± 0.3 cu.in.

Net Weight With Oil 17.8 lbs, 8.1 kg Approved Oils FREOL α 22 Residual Moisture 120 mg max. Impurities 10 mg max. Displacement 4.33 cc. / 0.264 cu. in.

Panasonic QA43K11GAU6 — LR - 36593 LR - 100738 diagram (page 2)
Abb. 4

Panasonic Industrial Company Refrigeration Products Department Tel: 201 - 392 - 4249 Fax: 201 - 392 - 4315 Rev#1-5/9

Frage zu Panasonic QA43K11GAU6 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Panasonic QA43K11GAU6

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Panasonic QA43K11GAU6 PDF-Anleitung

2 Seiten·62 KB·Kompressor·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…