Benutzeranleitung / Produktwartung EMR898A des Produzenten Oregon Scientific
Zur Seite of 14
GB Oregon Scientific“ In-Out Thermometer with Cable-Free Sensor and RF Clock Model: EMR898A User Manual T ABLE OF CONTENTS Introduction ................................................................................ 1 Brief Description ............
GB GB Clock Functions ......................................................................... 14 Enabling / Disabling Radio Reception .................................. 15 Language Options ............................................................
GB GB GENERAL W ARNINGS ¥ Do not attempt to repair the product yourself. Contact the retailer or our customer service department if it requires servicing.
GB GB OTHER NOTICES Disposing of this Product When disposing of this product, do so in accordance with your local waste disposal regulations. Statement of Responsibility Oregon Scientific assumes no r.
GB GB REMOTE UNIT Front View A. LCD Status Display Displays the current temperature measured by the remote unit. B. LED Indicator Flashes when the remote unit transmits a reading. Back View C. ° C/ ° F Slide Switch Selects temperature display between degrees Fahrenheit ( ° F) or Centigrade ( ° C).
GB GB Remote Unit 1 . Locate the battery compartment at the back of the remote unit ( → p. 6,E. ). 2 . Remove the screws on the battery compartment using a screwdriver (sold separately). 3. Insert two 1.5V alkaline AA batteries into the compartment, making sure to align the polarities correctly as shown by the diagram.
GB GB Remote Unit Similarly, you can choose to either mount the remote unit on a wall or make it stand on a flat surface. It is recommended to place the unit away from direct sunlight, rain, and snow.
GB GB REMOTE TEMPERA TURE READINGS The remote temperature readings are displayed on the top line of the LCD screen display ( → p. 1 1,A. ). Kinetic W ave Display The Kinetic W ave Display is only shown on the top line of the main unit. It displays the current receiving signal status from the remote unit to the main unit.
GB GB Resetting Maximum / Minimum T emperatures T o clear the maximum and minimum recorded temperatures: CLOCK FUNCTIONS Y our product is designed to synchronize its calendar clock automatically once it is brought within range of the radio signal from the U.
GB GB LANGUAGE OPTIONS TIME ZONE OPTIONS T ime zones around the world are identified by how many hours they are offset from the Greenwich Mean Time (GMT). US time zones are 5 to 10 hours behind the Greenwich Mean T ime. The main unit is pre- set to Pacific Standard T ime (PST).
GB GB * These states have certain parts where a different time zone is followed. Check to make sure to set the correct time zone for your area. ** These states have certain areas where Daylight Savings are not observed. In Hawaii, the whole state does not follow Daylight Savings.
GB GB ALARM FUNCTIONS The unit is equipped with 2 alarms: Weekday Alarm and Single Alarm. Activating / De-activating the Alarms T o return to normal clock mode, press the MODE button anytime during the procedures below. Setting the Alarms Press or to adjust the values for each setting.
GB GB Press SNOOZE ( → p. 5,M. ) to temporarily stop the alarm. The alarm will sound again after 8 minutes unless another key on the clock is pressed. T o stop the ringing completely , press ALARM . The Single Alarm will automatically disable itself after the clock has gone off at the preset time.
GB GB SPECIFICA TIONS Main Unit T ype Description T emperature Operation Range -4ßF to 140ßF (-20.0ßC to +60.0ßC) T emperature Resolution 0.2ßF (0.1ßC) RF T ransmission Frequency 433 MHz RF T ransmission Range Maximum 100 feet (30 meters) T emperature Sensing Cycle 78 seconds Power 2 x UM-3 or AA 1.
Ein wichtiger Punkt beim Kauf des Geräts Oregon Scientific EMR898A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Oregon Scientific EMR898A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Oregon Scientific EMR898A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Oregon Scientific EMR898A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Oregon Scientific EMR898A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Oregon Scientific EMR898A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Oregon Scientific EMR898A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Oregon Scientific EMR898A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Oregon Scientific EMR898A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.