Benutzeranleitung / Produktwartung FMG90 des Produzenten Omega Engineering
Zur Seite of 18
omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info FMG90 Series Electromagnetic Flow Meter Shop online at U ser ’ s Guide.
.
Table of contents page 1 About this oper ating m anual.................................................................................... 4 2 Device descr iption ........................................................................................
1 About this operating manual • The operating manual is aimed at specialists and semi-skilled personnel. • Before each step, read through the relevant adv ice carefully and keep to the specified order. • Thoroughly read and understand the information in the section (Safety Instructions " 3 " ).
2 Device description The FMG90 series from Omega, is a non-c ontact flow sensor. The measurement is performed using magnetic induction and works without any moving parts.
2.1 Intended use The magnetic inductive flow sensor FMG90 mu st only be used for measuring and metering liquids with a minimum conductivity of 20 μ S/cm. WARNING! No safety component! The magnetic inductive flow sensor of the series FMG90 are not safety components in accordance with Directive 2006-42-EC (Machine Directive).
3 Safety instructions Before you install the FMG90, read through this operating manual carefully. If the instructions contained within it are not follow ed, in particular the safety guidelines, this could result in danger for people, the envir onment, and the device and the system it is connected to.
4 Construction and function Construction: The measuring tube with its ear thing sleeves and electrodes passes through the sensor housing and forms the external process connection of the FMG90. A magnetic field for the measur ement process is generated inside the sensor housing, which also contains the sensor and signal conditioning circuitry.
5.1 Installation instructions CAUTION! Risk of malfunction due to external magnetic fields! Magnetic fields close to the device can cause malfunctions and should be avoided. ª Ensure that no external magnet ic fields are present at the installation site of the FMG90.
• If two or more FMG90 devices are used side by side, maintain a separation of at least 2.5 cm between adjacent devices. If adjacent devices are too cl ose together, operation of both devices may be impaired due to mutual interference. 5.2 Assembly The FMG90 is installed directly into the pipe line.
6 Electrical connection The electrical connection of the FMG90 is via the 4-pin plug M12x1 at the top. The corresponding connection cables with moulded coupling socket are available in various lengths. CAUTION! Electric current! The electrical connection should only be carried out by a fully qualified electrician.
7 Commissioning and measuring operation Before switching on the FMG90 for the first time , please follow the instructions in the following section. 7.1 Commissioning Check that the FMG90 has been installed correctly and that all screw connections are sealed.
9 Disassembly and disposal CAUTION! Risk of injury! Never remove the device from a plant in operation. ª Make sure that the plant is shut down professionally. Before disassembly: Prior to disassembly, ensure that the equipment is switched off and is in a safe and de-energised state.
10 Technical data The technical data of customised versions may differ from the data in these instructions. Please observe the information specified on the type plate. Type FMG 91 FMG 92 FMG 93 FMG 94 FMG 95 FMG 96 Measurement device characteristics Flow range [GPM] 0.
10.1 Materials table Component Material Component- w etted Sensor housing ABS Measuring tube PVDF X Process connections PVDF X O-ring EPDM X Electrodes Stainless steel 316L X Grounding rings Stainless steel 316L X 10.
10.3 Dimensions FMG 91 - 95 Ty pe L1 L2 D1 D2 FMG 91 4± 0.02 0.83 ± 0.01 ½ - 14 NPT Ø 0.31 FMG 92 4± 0.02 0.83 ± 0.01 ½ - 14 NPT Ø 0.31 FMG 93 4.02± 0. 02 0.83± 0.01 ¾ - 14 NPT Ø 0.55 FMG 94 4.41± 0. 02 0.98± 0.01 1 – 11.5 NPT Ø 0.71 FMG 95 4.
.
M-5204/1112.
Ein wichtiger Punkt beim Kauf des Geräts Omega Engineering FMG90 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Omega Engineering FMG90 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Omega Engineering FMG90 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Omega Engineering FMG90 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Omega Engineering FMG90 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Omega Engineering FMG90 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Omega Engineering FMG90 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Omega Engineering FMG90. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Omega Engineering FMG90 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.