PROGRAMMABLE PROCESS MONITORS USER ’ S MANUAL DP3600, DP3700 AND DP3800 SERIE S OMEGA ENGINEERING, INC., ONE OMEGA DRIVE, STAMFORD, CT 06907. MANUAL: M881/0399.
1 SPECIFICATIONS ............................................................................................................................................................................................... 3 DESCRIPTION ............................
2 SCALING .............................................................................................................................................................................................................. 12 OFFSET ........................
3 SPECIFICATIONS (typical @ 25 C and rated supply voltage unless otherwise specified). STANDARD INPUT: * 4 - 20 MA, 10 - 50 MA, 0 - 5 VDC, 0 - 10 VDC EXTERNAL HOLD: * An external low level signal applied to the HOLD pin on the rear connector will initiate hold function.
4 DESCRIPTION The DP3600 series of instrumen ts are micro - processor based intelligent monitors that are capable of performing several tasks in addition to displaying the process variable.
5 PROGRAM LIMITS 1. Process Limit1 2. Process Limit2 3. Setup limt 3 f or Rate/Process 4. Process Limit 3 5. Setup Limit4 for Process/Deviation 6. Process Limit 4 7. Timer 1 Limit 8. Timer 2 Limit 9. Deadband for limits 9. Limits Normally open/close (1 Thru 4) 10.
6 Offset: Next configurable function is offset and is indicated by the message ‘OFFSET’ followed by current offset value. To change the v alue of flashing digit press ^v key. To move the flashing digit, push <NXT> key. After programming the desired value of offset, push the "SETUP" key to get to the next function.
7 Selection of Limit 4 as Process or Deviation Limit: This step comes after programming Limit 3 and is indicated by the message ‘LT3 Pr’ (if Limit 3 is setup as Process limit ) or ‘LT3 dEN’ (if Limit 3 is setup as deviation limit). Alternate selection can be made by pushing ^v key.
8 Audio Alarm On/Off: This unit supports an audio alarm which comes on when ever a limit value is exceeded. This alarm can be turned On or Off, as desired. The selection is made by pushing ^v key. If the alarm is ON, the display will read ‘ALR ON’ (Alarm On).
9 Rate Time - Base: This step is for programming time - base for calculation of Rate. Units of time - base are seco nds. Again, the active digit will be flashing. To change the value, push ^v key. To activate another digit for change, use <NXT> key.
10 SET UP FLOW CHART: SETUP SCALING (SCALING) HIGH SCALE (HI SCLE) LOW SCALE (LO SCLE) OFFSET (OFFSET) TARE (TARE) PROGRAM PROCESS LIMIT 1 (PrG Lt1 -- 01.234) PROGRAM PROCESS LIMIT 2 (PrG Lt2 -- 01.234) LIMIT 3 RATE OR PROCESS (Lt3 rtE) or (Lt3 Pr) PROGRAM LIMIT 3 VALUE (PrG Lt3 -- 02.
11 MAX. AND MIN. READIN GS (PEAKS) Displaying: To display the peak values of Process variable push Peak key once and let go. The display will first indicate ‘ HIGH Pt’ briefly and then the value of the highest Process variable value monitored by the system.
12 PROCESS CHANGE Displaying: The system will constantly monitor the total amount of change in process variable since start or last reset. This change is displayable in engineering units by pushing the ‘PR CNG’ k ey. This function is useful in tracking the change that has taken place in the process e.
13 TARE Tare function is used for taking out a preset amount of process variable from the total reading e.g. if we are measuring weight of a certain p roduct being put in a container but do not want the weight of the container to show on the display, then enter the weight of the container as tare value.
14 Timer Limits: Displaying: To display timer limits, first push the TIME key. While still in this mode go on to push LIMITS key. The display will briefly show TR1 LT (for timer 1 Limit) and then the previously programmed value. Pushing the LIMITS key one more time will display TR2 LT followed by pre - programmed timer 2 value.
15 Open Collector Option Whenever a limit is reached an open collector output provides a 5 Vdc signal at 50ma. on the output connector, e.g... Limit 1 provides its 5 volt output signal between pins 1 and 2.
16 PIN NO DESCRIPTION 1 LIMIT 1 COMMON/OPEN COLLECTOR POSITIVE 2 LIMIT 1 NORMALLY OPEN/OPEN COLLECTOR NEGA TIVE 3 LIMIT 2 COMMON/OPEN COLLECTOR POSITIVE 4 LIMIT 2 NORMALLY OPEN/OPEN COLLECTOR NEGATIVE.
17 TROUBLE SHOOTING If the meter locks on a particular display, unplug and plug in again the meter to unlock the display. A total reset defaults all scaling values to zero.
18 A 1 2 3 4 3 B 3.62" (91.9mm) 1.70" 43.2mm NOT DRAWN TO SCALE Back of the Meter Bracket Screw Driver Push Meter this way with the Screwdriver MOUNTING 1. Cut a hole in panel to the specifications shown in the figure 4 : Figure 4. Panel Cutout Dimensions 2.
Ein wichtiger Punkt beim Kauf des Geräts Omega Engineering DP3600 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Omega Engineering DP3600 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Omega Engineering DP3600 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Omega Engineering DP3600 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Omega Engineering DP3600 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Omega Engineering DP3600 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Omega Engineering DP3600 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Omega Engineering DP3600. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Omega Engineering DP3600 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.