M2216/1201 http://www.omega.com e-mail: info@omega.com ® U ser ’ s Guide CCT -05 Frequency Input Signal Conditioners.
Servicing North America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: canada@omega.
NOTES T ABLE OF CONTENTS PAGE Open the Housing . . . . . . . . . . . . . . . . . . . . . . . . 3 Internal Overview . . . . . . . . . . . . . . . . . . . . . . . . 3 Power Supply module MA . . . . . . . . . . . . . . . . . . 4 Changing the Power Supply .
MECHANICAL DIMENSIONS 75 mm (2.952") 110 mm (4.33") 36 mm (1.417") 45 mm (1.771") OUTPUT S / SALI DAS m A Vdc INPU T / ENTR A D A S U PP L Y / AL IME N T ACI ON 3 4 5 6 9 10 1 1 12 7 1 + Lo H i + -- TECHNICAL DATA WEIGHT . . . . . .
SIGNAL OUTPUT Current SIGNAL OUTPUT Voltage Sensor NAMUR CONNECTIONS + OUTPUTS / SALIDA S mA V dc INPUT / ENTRA DA SUPPL Y / ALIM ENT ACIO N 3 4 5 6 9 10 1 1 1 2 7 1 + Lo H i + -- POWER SUPPLY The side label, shows the type and value of the power supply.
3 2 1 4 5 6 7 9 8 10 PT1 Fine gain adjust PT2 Trigger adjust SELECTOR A FIG. 8 The frequency ranges are interpreted as follow : Range A (0 to 40/70 Hz.) which means that the minimum range is from 0 to 40 Hz, and the maximum range from 0 to 70 Hz. The high level of the signal output can be adjusted for any value between 40 to 70 Hz.
INPUT SIGNAL TYPE PNP, NPN, Namur, Vac FREQUENCY Min. 10 Hz. Max. 40 KHz. AUXILIARY POWER SUPPLY +24 Vdc @ 25 mA. for PNP, NPN. 8.2 Vdc for Namur OUTPUT 0 to 20 mA or 4 to 20 mA R L < 600 Ω max. 22 mA ±3% 0 to 10 Vdc R L > 1000 Ω max. 11 V ±3% ACCURACY ≤ 0.
INPUT SIGNAL TYPE PNP, NPN, Namur, Vac FREQUENCY Min. 10 Hz. Max. 40 KHz. AUXILIARY POWER SUPPLY +24 Vdc @ 25 mA. for PNP, NPN. 8.2 Vdc for Namur OUTPUT 0 to 20 mA or 4 to 20 mA R L < 600 Ω max. 22 mA ±3% 0 to 10 Vdc R L > 1000 Ω max. 11 V ±3% ACCURACY ≤ 0.
3 2 1 4 5 6 7 9 8 10 PT1 Fine gain adjust PT2 Trigger adjust SELECTOR A FIG. 8 The frequency ranges are interpreted as follow : Range A (0 to 40/70 Hz.) which means that the minimum range is from 0 to 40 Hz, and the maximum range from 0 to 70 Hz. The high level of the signal output can be adjusted for any value between 40 to 70 Hz.
SIGNAL OUTPUT Current SIGNAL OUTPUT Voltage Sensor NAMUR CONNECTIONS + OUTPUTS / SALIDA S mA V dc INPUT / ENTRA DA SUPPL Y / ALIM ENT ACIO N 3 4 5 6 9 10 1 1 1 2 7 1 + Lo H i + -- POWER SUPPLY The side label, shows the type and value of the power supply.
MECHANICAL DIMENSIONS 75 mm (2.952") 110 mm (4.33") 36 mm (1.417") 45 mm (1.771") OUTPUT S / SALI DAS m A Vdc INPU T / ENTRAD A S U PP L Y / A L IMEN T AC I ON 3 4 5 6 9 10 1 1 12 7 1 + Lo H i + -- TECHNICAL DATA WEIGHT . . . . . .
NOTES T ABLE OF CONTENTS PAGE Open the Housing . . . . . . . . . . . . . . . . . . . . . . . . 3 Internal Overview . . . . . . . . . . . . . . . . . . . . . . . . 3 Power Supply module MA . . . . . . . . . . . . . . . . . . 4 Changing the Power Supply .
WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
Where Do I Find Everything I Need for Process Measurement and Control? OM EGA…Of Course! TEMPERATURE M U Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies M U Wire: Ther.
Ein wichtiger Punkt beim Kauf des Geräts Omega CCT-05 Series (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Omega CCT-05 Series noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Omega CCT-05 Series - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Omega CCT-05 Series reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Omega CCT-05 Series erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Omega CCT-05 Series besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Omega CCT-05 Series verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Omega CCT-05 Series. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Omega CCT-05 Series gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.