Processes
Description
Arc Welding Power Source
Maxstar 152 And 175
Visit our website at www.MillerWelds.com

Thank you and congratulations on choosing Miller. Now you can get the job done and get it done right. We know you don’t have time to do it any other way.

That’s why when Niels Miller first started building arc welders in 1929, he made sure his products offered long-lasting value and superior quality. Like you, his customers couldn’t afford anything less. Miller products had to be more than the best they could be. They had to be the best you could buy.
Today, the people that build and sell Miller products continue the tradition. They’re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929.
Working as hard as you do – every power source from Miller is backed by the most hassle-free warranty in the business.
This Owner’s Manual is designed to help you get the most out of your Miller products. Please take time to read the Safety precautions. They will help you protect yourself against potential hazards on the worksite. We’ve
made installation and operation quick and easy. With Miller you can count on years of reliable service with proper maintenance. And if for some reason the unit needs repair, there’s a Troubleshooting section that will help you figure out what the problem is. The parts list will then help you to decide which exact part you may need to fix the problem. Warranty and service information for your particular model are also provided.

Miller is the first welding equipment manufacturer in the U.S.A. to be registered to the ISO 9001 Quality System Standard.
Miller offers a Technical Manual which provides more detailed service and parts information for your unit. To obtain a Technical Manual, contact your local distributor. Your distributor can also supply you with Welding Process Manuals such as SMAW, GTAW, GMAW, and GMAW-P.

Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. To locate your nearest distributor or service agency call 1-800-4-A-Miller, or visit us at www.MillerWelds.com on the web.






Means Warning! Watch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.
Marks a special safety message.
This group of symbols means Warning! Watch Out! possible ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessary actions to avoid the hazards.
Means “Note”; not safety related.
The symbols shown below are used throughout this manual to call attention to and identify possible hazards. When you see the symbol, watch out, and follow the related instructions to avoid the hazard. The safety information given below is only a summary of the more complete safety information found in the Safety Standards listed in Section 1-4. Read and follow all Safety Standards.
If earth grounding of the workpiece is required, ground it directly with a separate cable – do not use work clamp or work cable.
Do not touch electrode if you are in contact with the work, ground, or another electrode from a different machine.
Use only well-maintained equipment. Repair or replace damaged parts at once. Maintain unit according to manual.
Wear a safety harness if working above floor level. Keep all panels and covers securely in place.
Only qualified persons should install, operate, maintain, and repair this unit.
During operation, keep everybody, especially children, away.
Clamp work cable with good metal-to-metal contact to workpiece or worktable as near the weld as practical.
Insulate work clamp when not connected to workpiece to prevent contact with any metal object.
ELECTRIC SHOCK can kill.
Do not connect more than one electrode or work cable to any single weld output terminal.
Touching live electrical parts can cause fatal shocks or severe burns. The electrode and work circuit is electrically live whenever the output is on. The input power circuit and machine internal circuits are also live when power is on. In semiautomatic or automatic wire welding, the wire, wire reel, drive roll housing, and all metal parts touching the welding wire are electrically live. Incorrectly installed or improperly grounded equipment is a hazard.
SIGNIFICANT DC VOLTAGE exists after removal of input power on inverters.
Turn Off inverter, disconnect input power, and discharge input capacitors according to instructions in Maintenance Section before touching any parts.
Do not touch live electrical parts. Wear dry, hole-free insulating gloves and body protection. Insulate yourself from work and ground using dry insulating mats or covers big enough to prevent any physical contact with the work or ground. Do not use AC output in damp areas, if movement is confined, or if there is a danger of falling. Use AC output ONLY if required for the welding process. If AC output is required, use remote output control if present on unit. Disconnect input power or stop engine before installing or servicing this equipment. Lockout/tagout input power according to OSHA 29 CFR 1910.147 (see Safety Standards). Properly install and ground this equipment according to its Owner’s Manual and national, state, and local codes.
FUMES AND GASES can be hazardous.
Welding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health.
Keep your head out of the fumes. Do not breathe the fumes.
If inside, ventilate the area and/or use exhaust at the arc to remove welding fumes and gases.
If ventilation is poor, use an approved air-supplied respirator. Read the Material Safety Data Sheets (MSDSs) and the manufacturer’s instructions for metals, consumables, coatings, cleaners, and degreasers. Work in a confined space only if it is well ventilated, or while wearing an air-supplied respirator. Always have a trained watch- person nearby. Welding fumes and gases can displace air and lower the oxygen level causing injury or death. Be sure the breath- ing air is safe.
Always verify the supply ground – check and be sure that input power cord ground wire is properly connected to ground terminal in disconnect box or that cord plug is connected to a properly grounded receptacle outlet. When making input connections, attach proper grounding conduc- tor first – double-check connections. Frequently inspect input power cord for damage or bare wiring – replace cord immediately if damaged – bare wiring can kill. Turn off all equipment when not in use. Do not use worn, damaged, undersized, or poorly spliced cables.
Do not weld in locations near degreasing, cleaning, or spraying op- erations. The heat and rays of the arc can react with vapors to form highly toxic and irritating gases.
Do not weld on coated metals, such as galvanized, lead, or cadmium plated steel, unless the coating is removed from the weld area, the area is well ventilated, and if necessary, while wearing an air-supplied respirator. The coatings and any metals containing these elements can give off toxic fumes if welded.
Do not drape cables over your body.
som _nd_5/97

ARC RAYS can burn eyes and skin.
BUILDUP OF GAS can injure or kill.
Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld.
Shut off shielding gas supply when not in use. Always ventilate confined spaces or use approved air-supplied respirator.
Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or watching (see ANSI Z49.1 and Z87.1 listed in Safety Standards).
HOT PARTS can cause severe burns.
Wear approved safety glasses with side shields under your helmet. Use protective screens or barriers to protect others from flash and glare; warn others not to watch the arc. Wear protective clothing made from durable, flame-resistant mate- rial (leather and wool) and foot protection.
Do not touch hot parts bare handed. Allow cooling period before working on gun or torch.
MAGNETIC FIELDS can affect pacemakers.
WELDING can cause fire or explosion.
Pacemaker wearers keep away. Wearers should consult their doctor before going near arc welding, gouging, or spot welding operations.
Welding on closed containers, such as tanks, drums, or pipes, can cause them to blow up. Sparks can fly off from the welding arc. The flying sparks, hot workpiece, and hot equipment can cause fires and burns. Accidental contact of electrode to metal objects can cause sparks, explosion, overheating, or fire. Check and be sure the area is safe before doing any welding.
NOISE can damage hearing.
Protect yourself and others from flying sparks and hot metal. Do not weld where flying sparks can strike flammable material. Remove all flammables within 35 ft (10.7 m) of the welding arc. If this is not possible, tightly cover them with approved covers. Be alert that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas. Watch for fire, and keep a fire extinguisher nearby. Be aware that welding on a ceiling, floor, bulkhead, or partition can cause fire on the hidden side. Do not weld on closed containers such as tanks, drums, or pipes, unless they are properly prepared according to AWS F4.1 (see Safety Standards). Connect work cable to the work as close to the welding area as practical to prevent welding current from traveling long, possibly unknown paths and causing electric shock and fire hazards. Do not use welder to thaw frozen pipes.
Noise from some processes or equipment can damage hearing.
Wear approved ear protection if noise level is high.
CYLINDERS can explode if damaged.
Shielding gas cylinders contain gas under high pressure. If damaged, a cylinder can explode. Since gas cylinders are normally part of the welding process, be sure to treat them carefully.
Protect compressed gas cylinders from excessive heat, mechani- cal shocks, slag, open flames, sparks, and arcs.
Install cylinders in an upright position by securing to a stationary support or cylinder rack to prevent falling or tipping.
Remove stick electrode from holder or cut off welding wire at contact tip when not in use. Wear oil-free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes, and a cap. Remove any combustibles, such as a butane lighter or matches, from your person before doing any welding.
Keep cylinders away from any welding or other electrical circuits.
Never drape a welding torch over a gas cylinder.
Never allow a welding electrode to touch any cylinder.
Never weld on a pressurized cylinder – explosion will result.
Use only correct shielding gas cylinders, regulators, hoses, and fit- tings designed for the specific application; maintain them and associated parts in good condition.
FLYING METAL can injure eyes.
Turn face away from valve outlet when opening cylinder valve.
Welding, chipping, wire brushing, and grinding cause sparks and flying metal. As welds cool, they can throw off slag. Wear approved safety glasses with side shields even under your welding helmet.
Keep protective cap in place over valve except when cylinder is in use or connected for use.
Read and follow instructions on compressed gas cylinders, associated equipment, and CGA publication P-1 listed in Safety Standards.

FIRE OR EXPLOSION hazard.
MOVING PARTS can cause injury.
Do not install or place unit on, over, or near combustible surfaces. Do not install unit near flammables. Do not overload building wiring – be sure power supply system is properly sized, rated, and protected to handle this unit.
Keep away from moving parts such as fans. Keep all doors, panels, covers, and guards closed and securely in place.
FALLING UNIT can cause injury.
H.F. RADIATION can cause interference.
Use lifting eye to lift unit only, NOT running gear, gas cylinders, or any other accessories. Use equipment of adequate capacity to lift and support unit. If using lift forks to move unit, be sure forks are long enough to extend beyond opposite side of unit.
High-frequency (H.F.) can interfere with radio navigation, safety services, computers, and communications equipment. Have only qualified persons familiar with electronic equipment perform this installation. The user is responsible for having a qualified electrician prompt- ly correct any interference problem resulting from the installa- tion. If notified by the FCC about interference, stop using the equipment at once. Have the installation regularly checked and maintained. Keep high-frequency source doors and panels tightly shut, keep spark gaps at correct setting, and use grounding and shielding to minimize the possibility of interference.
Allow cooling period; follow rated duty cycle. Reduce current or reduce duty cycle before starting to weld again. Do not block or filter airflow to unit.
STATIC (ESD) can damage PC boards.
Put on grounded wrist strap BEFORE handling boards or parts. Use proper static-proof bags and boxes to store, move, or ship PC boards.
ARC WELDING can cause interference.
Electromagnetic energy can interfere with sensitive electronic equipment such as computers and computer-driven equipment such as robots. Be sure all equipment in the welding area is electromagnetically compatible. To reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor. Locate welding operation 100 meters from any sensitive elec- tronic equipment. Be sure this welding machine is installed and grounded according to this manual. If interference still occurs, the user must take extra measures such as moving the welding machine, using shielded cables, using line filters, or shielding the work area.
MOVING PARTS can cause injury.
Keep away from moving parts. Keep away from pinch points such as drive rolls.
WELDING WIRE can cause injury.
Do not press gun trigger until instructed to do so. Do not point gun toward any part of the body, other people, or any metal when threading welding wire.
Safety in Welding and Cutting, ANSI Standard Z49.1, from American Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126 Safety and Health Standards, OSHA 29 CFR 1910, from Superinten- dent of Documents, U.S. Government Printing Office, Washington, D.C. 20402. Recommended Safe Practices for the Preparation for Welding and Cut- ting of Containers That Have Held Hazardous Substances, American Welding Society Standard AWS F4.1, from American Welding Society, 550 N.W. LeJeune Rd, Miami, FL 33126 National Electrical Code, NFPA Standard 70, from National Fire Protec- tion Association, Batterymarch Park, Quincy, MA 02269.
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 1235 Jefferson Davis Highway, Suite 501, Arlington, VA 22202. Code for Safety in Welding and Cutting, CSA Standard W117.2, from Canadian Standards Association, Standards Sales, 178 Rexdale Boulevard, Rexdale, Ontario, Canada M9W 1R3. Safe Practices For Occupation And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute, 1430 Broadway, New York, NY 10018. Cutting And Welding Processes, NFPA Standard 51B, from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

Considerations About Welding And The Effects Of Low Frequency Electric And Magnetic Fields Welding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of research, a special blue ribbon committee of the National Research Council concluded that: “The body of evidence, in the committee’s judgment, has not demonstrated that exposure to power- frequency electric and magnetic fields is a human-health hazard.” However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your exposure to electromagnetic fields when welding or cutting. To reduce magnetic fields in the workplace, use the following procedures:
About Pacemakers: Pacemaker wearers consult your doctor first. If cleared by your doctor, then following the above procedures is recommended.

Unless otherwise noted, the 175 model is shown throughout this manual. NOTE

Amperes Input at Rated Load Output KVA KW Weight Overall Dimensions
152 120 A @ 25 Volts DC, 100% Duty Cycle 1–150 95 230 Volts AC; 50/60 Hz; Single-Phase
175 140 A @ 25.6 Volts DC, 100% Duty Cycle 1–175 95 460 Volts AC; 50/60 Hz; Three-Phase

The volt-ampere curves show the minimum and maximum voltage and amperage output capabilities of the welding power source. Curves of other settings fall between the curves shown.


Duty Cycle is percentage of 10 min- utes that unit can weld at rated load without overheating.
100% Duty Cycle At 120 Amperes For 152 Models; 140 Amperes For 175 Models
Exceeding duty cycle can damage unit and void warranty.
rduty1 5/95 – SB-121 591-B / SB-144 507-B / ST-157 356-B


1 10 in (254 mm) Open Space On Right Side And Rear Of Unit For Good Airflow 2 Lifting Handle

Determine total cable length in weld circuit and maximum welding am- peres. Use Section 3-3 to select proper cable size.
Use lugs of proper amperage ca- pacity and hole size for connecting to work clamp, electrode holder, or wire feeder.
Total Cable Length In Weld Circuit = 20 ft (6 m)

100 ft (30 m) Or Less 150 ft (45 m)
60 Thru 100% Duty Cycle 10 Thru 100% Duty Cycle
100 4 4 4 3 2 1 1/0 1/0 150 3 3 2 1 1/0 2/0 3/0 3/0 200 3 2 1 1/0 2/0 3/0 4/0 4/0 250 2 1 1/0 2/0 3/0 4/0 2-2/0 2-2/0
*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least than 300 circular mils per ampere. S-0007-D


For Electrode Positive (DCEP), connect work cable connector to negative (–) receptacle and elec- trode holder cable connector to positive (+) receptacle.

To connect to receptacle, align keyway, insert plug, and tighten threaded collar.
sb7.1 5/94 – ST-801 174 / Ref. S-0004-A / S-0750 / Ref. ST-141 127-B


B Contact closure to A completes +15 volts dc contactor control circuit.
C Output command reference; 0 to +10 volts dc depending on setting of Amperage Adjustment control R4.
E Input command signal (potentiometer wiper or 0 to +10 volts dc).
*The remaining sockets are not used.

Select size and length using Sec- tion 3-8. Conductor rating must comply with national, state, and local electrical codes.
Install and connect input conduc- tors and grounding conductor in conduit or equivalent between wall receptacle and deenergized line disconnect device.
Be sure grounding conductor goes to an earth ground.
Select type and size using Section 3-8. Install into deenergized line disconnect device (fused discon- nect switch shown).
Turn Off unit Power switch, and connect plug to receptacle.

Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes 40

Have only qualified persons make this installation.
1 Line Disconnect Device Of Proper Rating
Select size and length using Sec- tion 3-10. Conductor rating must comply with national, state, and local electrical codes. Strip 3/8 in (10 mm) insulation off conductors.
4 Strain Relief Connector
Remove wrapper and insert con- ductors.
5 Input Terminal Block
7 Welding Power Source Ground Terminal
Connect grounding conductor to ground terminal first. Then connect input conductors to line terminals. Tighten strain relief connector.
8 Disconnect Device Ground Terminal
Install and connect grounding conductor and input conductors in conduit or equivalent to deener- gized line disconnect device.
Connect grounding conductor first, then line input conductors. Be sure grounding conductor goes to an earth ground.
Reinstall wrapper.
Select type and size using Section 3-10. Install into deenergized line disconnect device (fused disconnect switch shown).
Tools Needed:
ssb2.4* 1/94 – ST-145 667-B / SA-145 666-C

Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes 10



For front panel control, place switch in On position.
For remote control, place switch in Remote 14 position (see Section 3-5).
Weld output receptacles are energized when switch is On and Power is On.

1 Amperage Adjustment Control
Use control to select weld amper- age. Amperage may be adjusted while welding.

2 Amperage Control Switch
Use switch to select way of control- ling amperage adjustment.
For front panel control, place switch in Panel position.
For remote control, place switch in Remote 14 position (see Section 3-5).
See Example below.
3 Remote Foot Control
4 Remote Hand Dial
EXAMPLE Of Combination Remote Amperage Control


Set Switches Adjust Remote Control Set Control
4-4. Weld Process Switch
1 Weld Process Switch

Use switch to select type of weld output current. Use GTAW position for Gas Tungsten Arc Welding. Use SMAW position for Shielded Metal Arc Welding.
Switch position determines the op- eration of the Lift-Arc switch (see Section 4-5).
5 Fingertip Control · Unit Minimum · Control Setting

Lift-Arc switch must be in Off position when using a High-Frequency unit with this welding power source, or when using the SMAW welding process. NOTE
Use switch to select Lift-Arc On or Off.
With Lift-Arc On, start an arc in GTAW welding as follows:
Touch tungsten electrode to work- piece at weld start point, hold elec- trode to workpiece for 1-2 sec- onds, and slowly lift electrode. An arc will form when electrode is lifted.

Normal open-circuit voltage is not present before tungsten electrode touches workpiece; only a low sensing voltage is present between electrode and workpiece. The solid- state output contactor does not en- ergize until after tungsten electrode is touching workpiece. This allows electrode to touch workpiece with- out overheating, sticking, or getting contaminated.
Do NOT Strike Like A Match!
Ref. S-156 279
Use switch to turn unit and pilot light On and Off.




Turn Off welding power source and disconnect input power. Remove wrapper. 1 Input Capacitor C1 (Both Models) 2 Input Capacitor C2 (175 Models Only) 3 Voltmeter Check input capacitor(s). Measure the dc voltage across the positive (+) and negative (–) terminals until voltage drops to near 0 (zero) volts. Proceed with job inside unit. Reinstall wrapper when finished.
Significant DC voltage can remain on capacitors after unit is Off. Always check capacitors as shown to be sure they have discharged before working on unit.
Tools Needed:
5/16 in

No weld output; unit completely inop- erative.
Be sure Power switch is On (see Section 4-6).
Secure power cord plug in receptacle (152 model) (see Section 3-7).
Be sure line disconnect switch is On (see Section 3-9).
Check line fuse(s) and replace if necessary. Reset circuit breakers (see Sections 3-7 or 3-9).
Check for proper input power connections (see Sections 3-7 or 3-9).
No weld output; fan motor FM running and pilot light on.
Check position of Output (Contactor) switch (see Section 4-2).
Thermostats TP1 and/or TP2 open (overheating). Allow fan to run; thermostat(s) closes when unit has cooled (see Section 2-3).
Low weld output with no control. Check position of Amperage Control switch (see Section 4-3).
Have Factory Authorized Service Station/Service Distributor check control board PC1.
Limited output and low open-circuit voltage.
Check incoming power for correct voltage. Replace line fuse if open or reset circuit breaker (see Sec- tions 3-7 or 3-9).
Check for proper input and output connections (see Sections 3-2, 3-4, and 3-7 or 3-9).
Erratic or improper weld output. Tighten all welding cable connections (see Sections 3-2 and 3-4).
Check for proper size and type of cable (see Section 3-2).
Check for proper input and output connections (see Sections 3-2, 3-4, and 3-7 or 3-9).
Replace electrode (see Section 7).
Arc not forming when using Lift-Arc. Check electrode and workpiece, clean as needed to allow good contact.
Fan motor FM does not run. Check and clear blocked fan blade; be sure blade is secure on shaft.
Have Factory Authorized Service Station/Service Distributor check fan motor FM.
Wandering arc; poor control of arc di- rection.
Reduce gas flow rate.
Select proper size tungsten (see Section 7-1).
Properly prepare tungsten (see Sections 7-2 and 7-3).
Tungsten electrode oxidizing and not remaining bright after conclusion of weld.
Shield weld zone from drafts.
Increase postflow time.
Check and tighten all gas fittings.
Water in torch. Refer to torch Owner’s Manual for part(s) requiring replacement, and repair torch as necessary.




TUNGSTEN ELECTRODE

For additional information, see your distributor for a handbook on the Gas Tungsten Arc Welding (GTAW) process.Wear clean gloves to prevent contamination of tungsten electrode. NOTE

Electrode Diameter DC – Argon – Electrode Negative/Straight Polarity
.010” Up to 15 * Up to 15 Up to 10
.010” Up to 25 * Up to 20 Up to 15
.010” * * Up to 20 Up to 15
♦Typical argon shielding gas flow rates are 15 to 35 cfh (cubic feet per hour).
*Not Recommended.
The figures listed are intended as a guide and are a composite of recommendations from American Welding Society (AWS) and electrode manufacturers.
gtaw 7/97

1 Tungsten Electrode 2 Balled End
Understand and follow safety symbols at start of Section 8-1 before preparing tungsten.
Ball end of tungsten before welding by applying either an ac amperage slightly higher than what is recom- mended for a given electrode diam- eter (see Section 7-1), or a dc electrode positive amperage.
Ref. S-0161
1 Tungsten Electrode 2 Tapered End
Grind end of tungsten on fine grit, hard abrasive wheel before weld- ing. Do not use wheel for other jobs or tungsten can become contami- nated causing lower weld quality.
2-1/2 Times Electrode Diameter
1 Stable Arc 2 Flat
Diameter of this flat determines amperage capacity.
3 Grinding Wheel 4 Straight Ground 3
Ideal Tungsten Preparation – Stable Arc
1 Arc Wander 2 Point 3 Grinding Wheel 4 Radial Ground
Wrong Tungsten Preparation – Wandering Arc
Ref. S-0161 / Ref. S-0162
1-1/2 Times · Electrode Diameter


Weld current can damage electronic parts in vehicles. Disconnect both battery cables before welding on a vehicle. Place work clamp as close to the weld as possible.
3 Torch 4 Filler Rod (If Applicable) 5 Tungsten Electrode
Select and prepare tungsten according to Sections 7-1, and 7-2 or 7-3.
Tungsten extension is the distance the tungsten extends out gas cup of torch.
Arc length is the distance from the tungsten to the workpiece.
As a general guide, start with an extension and arc length equal to diameter of tungsten.

Form pool Tilt torch Move torch to front of pool. Repeat process.
Move torch to front of pool. Repeat process. Remove rod

Butt Weld And Stringer Bead
20 °
20 °
70 °
10 ° 20 °
40 °
70 °
20 °
30 °
90 °
70 °
20 °
ST-162 003 / S-0792
“T” Joint · Lap Joint · Corner Joint

not available unless listed. *18 Is Supplied with 152 Model only

Figure 9-1. Main Assembly (175 Model Illustrated)

No. Dia. Mkgs. Item
Description Part
Model
No.
Figure 9-1. Main Assembly
1 195 585 HANDLE, rubberized carrying 1 1 3 134 327 LABEL, warning general precautionary 1 1 4 +163 781 WRAPPER 1 4 +163 782 WRAPPER 1 5 PC1 164 619 CIRCUIT CARD, control 1 1 PLG1,2 131 052 CONNECTOR & SOCKETS, (consisting of) 2 2 113 746 CONNECTOR, rect skt 24-18ga Molex 39-00-0038 16 16 PLG3 131 056 CONNECTOR & SOCKETS, (consisting of) 1 1 113 746 CONNECTOR, rect skt 24-18ga Molex 39-00-0038 14 14 PLG5 ++130 203 CONNECTOR & SOCKETS, (consisting of) 1 1 113 746 CONNECTOR, rect skt 24-18ga Molex 39-00-0038 12 12 6 141 690 GROMMET, scr No. 8/10 panel hole .281sq .197 high 6 6 7 140 627 INSULATION, PC card 1 1 8 151 280 BRACKET, mtg PC card 1 8 +141 520 BRACKET, mtg PC card 1 9 C1 151 281 CAPACITOR, elctlt 1600uf 400VDC 1 9 C1,2 151 281 CAPACITOR, elctlt 1600uf 400VDC 2 10 006 426 CLAMP, capacitor 2.000dia 1 2 11 153 178 LABEL, warning exploding parts etc 1 12 136 190 NUT, speed U type 10-32 2 4 13 133 405 NUT, speed 10-24 flat type rectangular 1 2 14 130 215 PLATE, output rear panel 1 14 140 373 PLATE, output rear panel 1 15 Neg,Pos 129 525 RECEPTACLE, twlk insul fem (Dinse type) 50/70 series 2 2 129 527 CONN, twlk insul male (dinse type) 50 series 2 2 16 145 743 LUG, univ w/scr 600V 2-14 wire 1 17 010 916 CONNECTOR, clamp cable .750 1 1 18 120 484 CORD SET, 250V 6-50P 12ga 3/c 8ft 1 19 TE1 147 386 BLOCK, term 70A 3P 1 20 147 255 BRACKET, mtg terminal block 1 21 119 757 BAR, support heat sink bottom 1 1 22 126 372 STRIP, polyest gl lam .187 x .250 x .625 1 1 23 140 626 STRIP, polyest gl lam .187 x .500 x 2.250 1 1 24 +128 803 BAR, support heat sink top 1 1 25 CT1 150 925 TRANSFORMER, current 1 1 26 Fig 9-2 MODULE, power 1 1 27 Fig 9-2 MODULE, diode 1 1 28 141 515 STRIP, polyest gl lam .187 x .500 x .812 1 1 29 126 026 LABEL, warning electric shock can kill 1 1 30 119 943 STRIP, polyest gl lam .187 x .500 x 6.500 1 30 140 380 STRIP, polyest gl lam .187 x .500 x 8.687 1 31 Z1 130 794 STABILIZER 1 31 Z1 131 866 STABILIZER 1 32 019 663 MOUNT, nprn 15/16 OD 4 4 33 HD1 156 149 TRANSDUCER, current 1 33 HD1 124 684 TRANSDUCER, current 300A module supply 1 PLG10 130 204 CONNECTOR & SOCKETS, (consisting of) 1 1 114 066 CONNECTOR, rect skt 20-14ga Amp 350536-1 3 3 34 T1 151 585 TRANSFORMER, pwr main 1 34 T1 141 669 TRANSFORMER, pwr main 325 1 35 R2 139 203 RESISTOR, WW fxd 30W 8K ohm 1 35 R2,3 139 203 RESISTOR, WW fxd 30W 8K ohm 2 36 R1 136 076 RESISTOR, WW fxd 30W 200 ohm 1 1 37 141 422 INSULATOR, flat pack 1 1 38 S1 090 328 SWITCH, tgl DPST 40A 600VAC 1

No. Dia. Mkgs. Item
Description Part
Model
No.
Figure 9-1. Main Assembly (Continued)
PLG11 115 094 CONNECTOR & SOCKETS, (consisting of) 1 113 746 CONNECTOR, rect skt 24-18ga Molex 39-00-0038 4 RC11 115 090 CONNECTOR & PINS, (consisting of) 1 114 656 CONNECTOR, rect pin 24-18ga Molex 39-00-0040 4 047 838 BLANK, snap-in nyl 1.000mtg hole 1 38 S1 091 441 SWITCH, tgl 3PST 40A 600V 1 39 148 297 NUT, speed U type 10-32 2 2 40 146 684 INSULATOR, switch pwr 1 41 CR1 106 462 RELAY, encl 24VDC DPDT 1 1 42 NAMEPLATE, (order by model and serial number) 1 1 43 PL1 157 958 LIGHT, ind white lens 28V 1 1 44 S2-5 120 376 SWITCH, rocker SPDT 4A 250VAC 4 4 45 166 883 NAMEPLATE, meter 1 1 46 166 881 BLANK, meter nameplate backing 1 1 47 097 922 KNOB, pointer 1 1 48 R4 073 562 POTENTIOMETER, C sltd sft 1/T 2W 10K ohm 1 1 49 151 533 PANEL, front 1 49 146 333 PANEL, front 1 50 161 098 BUS BAR, output 1 1 51 134 756 LABEL, warning electric shock can kill 1 52 C12 135 286 CAPACITOR 1 1 53 C13 135 289 CAPACITOR 1 1 54 C14 141 524 LEAD ASSEMBLY, elect 1 1 54 C15 141 525 LEAD ASSEMBLY, elect 1 1 54 C16 141 522 LEAD ASSEMBLY, elect 1 1 54 C17 141 523 LEAD ASSEMBLY, elect 1 1 55 RC7 143 976 CONNECTOR w/SOCKETS, (consisting of) 1 1 079 534 CONNECTOR, circ skt push-in 14-18ga Amp 66358-6 14 14 134 734 CONNECTOR, circ 14 pin plug Amp 213571-2 134 731 CONNECTOR, circ pin push-in 14-18ga Amp 213603-1 079 739 CONNECTOR, circ clamp str rlf .703 max cable OD
Amp 206322-2 (or) 143 922 CONNECTOR, circ clamp str rlf .453 max cable OD
Amp 206070-3 56 168 755 CASE SECTION, bottom/rear 1 56 140 621 CASE SECTION, bottom/rear 1
+When ordering a component originally displaying a precautionary label, the label should also be ordered. ++Included with Interconnecting Circuit Card PC2. To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor.


1 C11 093 085 CAPACITOR, polye MF .0047uf 1000V 1 1 2 158 540 MODULE, pwr (consisting of) 1 2 170 702 MODULE, pwr (consisting of) 1 3 156 247 BLADE, fan 6 in 4wg 30deg .252 bore CCW 1 3 170 706 KIT, fan blade (consisting of) 1 4 605 525 NUT, .312-24 stl elastic stop 1 5 FM 156 246 MOTOR, fan 120/230V 2600RPM w/36V sec (consisting of) 1 RC6 135 409 CONNECTOR & PINS, (consisting of) 1 114 656 CONNECTOR, rect pin 24-18ga 8 5 FM 170 692 MOTOR, fan 230/460V 2600RPM w/36V sec (consisting of) 1 RC11 165 895 CONNECTOR & PINS, (consisting of) 1 147 996 CONNECTOR, rect skt pin 22-18ga 9 6 146 238 BRACKET, mtg fan motor 1 1 7 +151 484 HEAT SINK, pwr module 1 7 141 423 HEAT SINK, pwr module 1 8 Q1-4 149 207 KIT, transistor mosfet 4 4 9 D5 149 215 KIT, diode fast recovery 1 10 TP2 032 810 THERMOSTAT, NC 1 1 11 SR1 149 218 KIT, rectifier integ 100A 1 11 SR1 149 217 KIT, rectifier integ 100A 1 12 VCM1 164 849 MODULE, varistor/capacitor 4 400 joule 1620-1980VDC 1 13 PC2 151 284 CIRCUIT CARD, interconnecting 1 13 PC2 167 368 CIRCUIT CARD, interconnecting 1 PLG6 115 092 CONNECTOR & SOCKETS, (consisting of) 1 113 746 CONNECTOR, rect skt 24-18 ga 8 PLG11 163 467 CONNECTOR & SOCKETS, (consisting of) 1 147 995 CONNECTOR, rect skt 24-18 ga 9 14 153 178 LABEL, warning exploding parts etc 1 15 VR4 004 113 VARISTOR, 40 joule 390VDC 1 1

Hardware is common and

Model
No. Dia. Mkgs. Item
Description Part
No.
Figure 9-2. Module, Power & Diode (Fig 9-1 Item 26 & 27) (Continued)
16 R10 030 839 RESISTOR, WW fxd 5W 220 ohm 1 1 17 DM1 151 479 MODULE, diode (consisting of) 1 17 DM1 140 492 MODULE, diode (consisting of) 1 18 D5,6 151 229 KIT, diode ultra fast recovery 1 1 19 151 470 HEAT SINK, diode module 1 19 140 622 HEAT SINK, diode module 1 20 R9 098 324 RESISTOR, WW fxd 25W 5 ohm 1 20 R5 098 324 RESISTOR, WW fxd 25W 5 ohm 1 21 D1,2 151 431 KIT, diode ultra fast recovery 1 1 22 C9,10 098 325 CAPACITOR, polyp film .027uf 630V 2 2 23 TP1 129 552 THERMOSTAT, NC 1 1
+When ordering a component originally displaying a precautionary label, the label should also be ordered. To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor.




Effective January 1, 2000 (Equipment with a serial number preface of “LA” or newer)
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor.
guarantees or warranties expressed or implied.
LIMITED WARRANTY – Subject to the terms and conditions below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants to its original retail purchaser that new Miller equipment sold after the effective date of this limited warranty is free of defects in material and workmanship at the time it is shipped by Miller. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.
* APT, ZIPCUT & PLAZCUT Model Plasma Cutting Torches * Remote Controls * Accessory Kits * Replacement Parts (No labor) * Spoolmate 185 & Spoolmate 250 * Canvas Covers
Within the warranty periods listed below, Miller will repair or replace any warranted parts or components that fail due to such defects in material or workmanship. Miller must be notified in writing within thirty (30) days of such defect or failure, at which time Miller will provide instructions on the warranty claim procedures to be followed.
Your distributor also gives you ...
Miller’s True Blue Limited Warranty shall not apply to:
Service You always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours.
Miller shall honor warranty claims on warranted equipment listed below in the event of such a failure within the warranty time periods. All warranty time periods start on the date that the equipment was delivered to the original retail purchaser, or one year after the equipment is sent to a North American distributor or eighteen months after the equipment is sent to an International distributor.
Support Need fast answers to the tough welding questions? Contact your distributor. The expertise of the distributor and Miller is there to help you, every step of the way.
MILLER PRODUCTS ARE INTENDED FOR PURCHASE AND USE BY COMMERCIAL/INDUSTRIAL USERS AND PERSONS TRAINED AND EXPERIENCED IN THE USE AND MAINTENANCE OF WELDING EQUIPMENT.
In the event of a warranty claim covered by this warranty, the exclusive remedies shall be, at Miller’s option: (1) repair; or (2) replacement; or, where authorized in writing by Miller in appropriate cases, (3) the reasonable cost of repair or replacement at an authorized Miller service station; or (4) payment of or credit for the purchase price (less reasonable depreciation based upon actual use) upon return of the goods at customer’s risk and expense. Miller’s option of repair or replacement will be F.O.B., Factory at Appleton, Wisconsin, or F.O.B. at a Miller authorized service facility as determined by Miller. Therefore no compensation or reimbursement for transportation costs of any kind will be allowed.
3. 1 Year — Parts and Labor * DS-2 Wire Feeder * Motor Driven Guns (w/exception of Spoolmate 185 & Spoolmate 250) * Process Controllers * Positioners and Controllers * Automatic Motion Devices * RFCS Foot Controls * Induction Heating Power Sources * Water Coolant Systems * HF Units * Grids * Maxstar 140 * Spot Welders * Load Banks * Miller Cyclomatic Equipment * Running Gear/Trailers * Plasma Cutting Torches (except APT & SAF Models) * Field Options (NOTE: Field options are covered under True Blue for the remaining warranty period of the product they are installed in, or for a minimum of one year — whichever is greater.)
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF PROFIT), WHETHER BASED ON CONTRACT, TORT OR ANY OTHER LEGAL THEORY.
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY IMPLIED WARRANTY, GUARANTY OR REPRESENTATION AS TO PERFORMANCE, AND ANY REMEDY FOR BREACH OF CONTRACT TORT OR ANY OTHER LEGAL THEORY WHICH, BUT FOR THIS PROVISION, MIGHT ARISE BY IMPLICATION, OPERATION OF LAW, CUSTOM OF TRADE OR COURSE OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE, WITH RESPECT TO ANY AND ALL EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND DISCLAIMED BY MILLER.
Some states in the U.S.A. do not allow limitations of how long an implied warranty lasts, or the exclusion of incidental, indirect, special or consequential damages, so the above limitation or exclusion may not apply to you. This warranty provides specific legal rights, and other rights may be available, but may vary from state to state.
In Canada, legislation in some provinces provides for certain additional warranties or remedies other than as stated herein, and to the extent that they may not be waived, the limitations and exclusions set out above may not apply. This Limited Warranty provides specific legal rights, and other rights may be available, but may vary from province to province.
miller_warr 7/00

Please complete and retain with your personal records.
Purchase Date (Date which equipment was delivered to original customer.)
Distributor
Address
City
State Zip
For Service
Call 1-800-4-A-Miller or see our website at www.MillerWelds.com to locate a DISTRIBUTOR or SERVICE AGENCY near you.
Always provide Model Name and Serial/Style Number.
Welding Supplies and Consumables
Options and Accessories
Personal Safety Equipment
Service and Repair
Miller Electric Mfg. Co. An Illinois Tool Works Company 1635 West Spencer Street Appleton, WI 54914 USA
Training (Schools, Videos, Books)
Circuit Diagrams
European Headquarters – United Kingdom Phone: 44 (0) 1204-593493 FAX: 44 (0) 1204-598066
File a claim for loss or damage during shipment.
For assistance in filing or settling claims, contact your distributor and/or equipment manufacturer’s Transportation Department.
PRINTED IN USA 2000 Miller Electric Mfg. Co. 6/00
In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.
Häufige Probleme, wahrscheinliche Ursachen und Lösungen.
| Problem | Mögliche Ursache | Abhilfe | |
|---|---|---|---|
| No weld output; unit completely inop- erative. | Be sure Power switch is On (see Section 4-6). | p.20 | |
| No weld output; unit completely inop- erative. | Secure power cord plug in receptacle (152 model) (see Section 3-7). | p.20 | |
| No weld output; unit completely inop- erative. | Be sure line disconnect switch is On (see Section 3-9). | p.20 | |
| No weld output; unit completely inop- erative. | Check line fuse(s) and replace if necessary. Reset circuit breakers (see Sections 3-7 or 3-9). | p.20 | |
| No weld output; unit completely inop- erative. | Check for proper input power connections (see Sections 3-7 or 3-9). | p.20 | |
| No weld output; fan motor FM running and pilot light on. | Check position of Output (Contactor) switch (see Section 4-2). | p.20 | |
| No weld output; fan motor FM running and pilot light on. | Thermostats TP1 and/or TP2 open (overheating). Allow fan to run; thermostat(s) closes when unit has cooled (see Section 2-3). | p.20 | |
| Low weld output with no control. | Check position of Amperage Control switch (see Section 4-3). | p.20 | |
| Low weld output with no control. | Have Factory Authorized Service Station/Service Distributor check control board PC1. | p.20 | |
| Limited output and low open-circuit voltage. | Check incoming power for correct voltage. Replace line fuse if open or reset circuit breaker (see Sec- tions 3-7 or 3-9). | p.20 | |
| Limited output and low open-circuit voltage. | Check for proper input and output connections (see Sections 3-2, 3-4, and 3-7 or 3-9). | p.20 | |
| Erratic or improper weld output. | Tighten all welding cable connections (see Sections 3-2 and 3-4). | p.20 | |
| Erratic or improper weld output. | Check for proper size and type of cable (see Section 3-2). | p.20 | |
| Erratic or improper weld output. | Check for proper input and output connections (see Sections 3-2, 3-4, and 3-7 or 3-9). | p.20 | |
| Erratic or improper weld output. | Replace electrode (see Section 7). | p.20 | |
| Arc not forming when using Lift-Arc. | Check electrode and workpiece, clean as needed to allow good contact. | p.20 | |
| Fan motor FM does not run. | Check and clear blocked fan blade; be sure blade is secure on shaft. | p.20 | |
| Fan motor FM does not run. | Have Factory Authorized Service Station/Service Distributor check fan motor FM. | p.20 | |
| Wandering arc; poor control of arc di- rection. | Reduce gas flow rate. | p.20 | |
| Wandering arc; poor control of arc di- rection. | Select proper size tungsten (see Section 7-1). | p.20 | |
| Wandering arc; poor control of arc di- rection. | Properly prepare tungsten (see Sections 7-2 and 7-3). | p.20 | |
| Tungsten electrode oxidizing and not remaining bright after conclusion of weld. | Shield weld zone from drafts. | p.20 | |
| Tungsten electrode oxidizing and not remaining bright after conclusion of weld. | Increase postflow time. | p.20 | |
| Tungsten electrode oxidizing and not remaining bright after conclusion of weld. | Check and tighten all gas fittings. | p.20 | |
| Tungsten electrode oxidizing and not remaining bright after conclusion of weld. | Water in torch. Refer to torch Owner’s Manual for part(s) requiring replacement, and repair torch as necessary. | p.20 |