Benutzeranleitung / Produktwartung USB-6525 data aquisition (DAQ) device des Produzenten National Instruments
Zur Seite of 16
USER GUIDE AND SPECIFICATIONS NI USB-6525 This user guide describes how to use the National Instruments USB-6525 data acquisi tion (D A Q) de vice. Introduction The NI USB-6525 is a full-speed USB 2.
USB-6525 User Guide an d Specifications 2 ni.com Figure 2. USB-6525 Back View Installing Software Software suppo rt for the USB-6525 for Wind ows 2000/XP is provided by NI-DAQmx. The NI-D A Q mx CD contains example programs th at you can use to get started programming with the USB-65 25.
© National Instruments Co rporation 3 USB-6525 User Guide and Specifications Refer to the Safety G uidelines section of this document for im portant safety information. Setting Up Hardware Complete the f ollowing st eps to set up the hardwa re: 1. Install combicon scr e w terminal blocks by inserting them into th e combicon jacks.
USB-6525 User Guide an d Specifications 4 ni.com I/O Connector The USB-6525 device ships with two d etachable terminal blocks for digital signals. Each indivi dual terminal accepts a wire gauge between 16 AWG–28 AWG. Table 1. Digital T erminal Assignments Module T erminal Signal Module T erminal Signal 1 P0.
© National Instruments Co rporation 5 USB-6525 User Guide and Specifications Signal Descriptions Table 2 describes the signals available on the I/O connectors. Digital I/O USB-6525 has eight channel-to-channel op tically isolated inputs, P1.<0..7>, and eight chann el-to-channel optically isolated solid-state relay outputs, P0.
USB-6525 User Guide an d Specifications 6 ni.com Applying a DC voltage of at least 3.2 V across two input terminals registers logic high. Applying no voltage or a voltage dif ference of 1 V or less registers logic lo w . DC voltages between 1 V and 3.
© National Instruments Co rporation 7 USB-6525 User Guide and Specifications Solid-State Relay (SSR) Outputs You can connect loads to the USB-6525. Connect the load to one of the leads of the power source. Connect either the P0. x A or the P0. x B terminal to the load and the other terminal to the other lead of the AC or DC power source.
USB-6525 User Guide an d Specifications 8 ni.com Figures 7 and 8 show examples of us ing an external flyback diode to protect DC inductiv e loads and an MO V to protect A C inducti ve loads, respecti vely . Figure 7. Contact Protection for DC Inductive Load s Figure 8.
© National Instruments Co rporation 9 USB-6525 User Guide and Specifications Using the USB-6525 as a TTL Output Device Figure 9 shows a sign al connection example for a TTL-level application with an external supply voltage of +5 V.
USB-6525 User Guide an d Specifications 10 ni.com Input current ........... .............. .............. ....3.0 mA/channel max Solid-State Relay Outputs Number of output channels ................. ....8, ch-ch isolated Relay type ...................
© National Instruments Corporation 11 USB- 6525 User Guide an d Specifications Power Requirements USB Input voltage ............ ........... ............ 4.5 to 5.25 VDC in configured state Active current ....... .............. ........... . 150 mA max Suspend current.
USB-6525 User Guide an d Specifications 12 ni.com Isolation Channel-to-channel ............. .............. ......60 VDC continuous Channel-to-earth ground ....... ...... ............60 VDC continuous Withstand . .......... .............. ........... .
© National Instruments Corporation 13 USB- 6525 User Guide an d Specifications CE Compliance This product meets the essential re quirements of applicable European Directives, as amended for CE markin.
USB-6525 User Guide an d Specifications 14 ni.com Operate the device only at or belo w Pollution Degree 2. Pollution is foreign matter in a solid, liquid, or gaseous state that can reduce dielectric strength or surface resisti vity .
© National Instruments Corporation 15 USB- 6525 User Guide an d Specifications • Measurement Category III is for measurements performed in the building installation at the distribution le vel. This cate gory refers to measurements on hard-wir ed equipment such as equipment in f ixed installations, distribution boards, and circuit breakers.
National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for more information abou t National Instruments trademarks. Other product and compan y names mentioned herein are trademarks or t rade names of their respective companie s .
Ein wichtiger Punkt beim Kauf des Geräts National Instruments USB-6525 data aquisition (DAQ) device (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie National Instruments USB-6525 data aquisition (DAQ) device noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für National Instruments USB-6525 data aquisition (DAQ) device - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von National Instruments USB-6525 data aquisition (DAQ) device reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über National Instruments USB-6525 data aquisition (DAQ) device erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon National Instruments USB-6525 data aquisition (DAQ) device besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von National Instruments USB-6525 data aquisition (DAQ) device verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit National Instruments USB-6525 data aquisition (DAQ) device. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei National Instruments USB-6525 data aquisition (DAQ) device gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.