1 W415-0223 / E / 03.05.09 W olf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada t (705)721-1212 t fax (705) 722-6031 www .napoleonreplaces.com t ask@napoleon.on.ca INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
2 W415-0223 / E / 03.05.09 Pg 2-4 INTRODUCTION W arranty General Instructions General Information Care of Glass & Plated Parts 5-7 INST ALLA TION Insert V ent Connection Chimney Connection W all S.
3 W415-0223 / E / 03.05.09 NAPOLEON gas fi replaces are manufactured under the strict Standard of the world recognized ISO 9001:2000 Quality Assurance Certi fi cate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0223 / E / 03.05.09 FOR YOUR SA TISF ACTION, THIS FIREPLACE INSERT HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUALITY! Minimum inlet gas supply pressure is 4.5 inches water col- umn for natural gas and 1 1 inches water column for propane.
5 W415-0223 / E / 03.05.09 36" 15 1 / 2 " 25" 10 9 / 16 " 5 ½" AIR INLET EXHAUST 4 15 / 16 " 15 1 / 2 " 11 5 / 8 " 7 3 / 8 " 3"Ø 44 7 / 8 " 3 SIDED BACKER PLATE ALUMINUM TRIM 44 7 / 8 " 36 1 / 2 " 4 SIDED BACKER PLATE ALUMINUM TRIM Provide adequate ventilation air .
6 W415-0223 / E / 03.05.09 2" OVERLAP EXHAUST SEALANT HI-TEMP INTAKE VENT CONNECTION ASSEMBLY Move the insert close to its fi nal position inside the wood- burning fi replace.
7 W415-0223 / E / 03.05.09 For ease of accessibility , an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route 2-strand solid core millivolt wire from the gas fi replace insert to the wall switch / millivolt thermostat.
8 W415-0223 / E / 03.05.09 Positioning the logs improperly will cause fl ame impingement and carboning. PHAZER TM logs and glowing embers, exclusive to Napoleon Fireplaces, glow when exposed to direct fl ame and provide a unique and realistic glowing effect that is dif ferent in every installation.
9 W415-0223 / E / 03.05.09 The on-off switch is located behind the left side control door . Purge all gas lines with the glass door open. Assure that a continuous gas fl ow is at the burner before closing the door . Allow several minutes (5-15) for the fl ame to stabilize after ignition.
10 W415-0223 / E / 03.05.09 1. Turn of f the electrical power and the gas supply to the fi replace insert. 2. Remove the fi re viewing door . Remove the logs. 3. Detach the two screws from the back of the fi rebox and remove the panel, as illustrated.
11 W415-0223 / E / 03.05.09 A mirror will let you see the opening of the air shutter without removing the burner . Scribe a line along the venturi tube and air shutter cap. Open or close according to the original opening by us- ing the scribed line as your datum.
12 W415-0223 / E / 03.05.09 31* W690-0001 MILLIVOL T THERMOST A T 32* W660-0010 REMOTE CONTROL - ADV ANT AGE 32* W660-001 1 REMOTE CONTROL - ADV ANTAGE PLUS 33* GD660 REMOTE W ALL SWITCH C / W 20FT WI.
13 W415-0223 / E / 03.05.09 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
14 W415-0223 / E / 03.05.09 PILOT BURNER THERMOCOUPLE THERMOPILE Main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engul fi ng the thermopile. Thermopile shorting Remote wall switch wire is too long, too much resistance in the system Faulty thermostat or switch - turn up pilot fl ame.
15 W415-0223 / E / 03.05.09 Exhaust fumes smelled in room, headaches. - check all seals. Fireplace is spilling. Carbon is being de- posited on glass, logs or combustion cham- ber surfaces. Flame is impinging on the logs or combustion chamber . - check that the logs are correctly positioned.
16 W415-0223 / E / 03.05.09 Appliance Ser vice Histor y This heater must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer Name 43.
Ein wichtiger Punkt beim Kauf des Geräts Napoleon Fireplaces GDIZC-N (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Napoleon Fireplaces GDIZC-N noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Napoleon Fireplaces GDIZC-N - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Napoleon Fireplaces GDIZC-N reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Napoleon Fireplaces GDIZC-N erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Napoleon Fireplaces GDIZC-N besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Napoleon Fireplaces GDIZC-N verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Napoleon Fireplaces GDIZC-N. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Napoleon Fireplaces GDIZC-N gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.