Benutzeranleitung / Produktwartung BGNV42P des Produzenten Napoleon Fireplaces
Zur Seite of 16
1 W415-0377 / C / 09.23.05 WARNING: If the information in these instructions is not followed exactl y , a fire or explosion may result causing property damage, personal injury or death. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.
2 W415-0377 / C / 09.23.05 PG 2-4 INTR ODUCTION Warranty General Instructions General Information Care of Glass & Plated Parts 5 VENTING Vent Safety Switch Hi Limit Switch Venting Action Check 6-7.
3 W415-0377 / C / 09.23.05 NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0377 / C / 09.23.05 Do not use abrasive cleaners to clean plated parts. Buff lightly with a clean dry cloth. The fireplace is factory equipped with 3/16" thick tempered glass. Use only replace- ment glass available from your Napoleon dealer.
5 W415-0377 / C / 09.23.05 This is a vented appliance and must be connected to a chimney in accordance with the current installation codes. In absence of local codes, install to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes.
6 W415-0377 / C / 09.23.05 It is best to frame your fireplace after it is positioned. Use 2x4's and frame to local building codes. FIGURE 7-9. Note: In order to avoid the possibility of exposed i.
7 W415-0377 / C / 09.23.05 NAILING T AB 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws sup- plied. Secure through the cen- tre of the top and bottom slots in the nailing tab and then through the existing holes in the corner posts.
8 W415-0377 / C / 09.23.05 The upper louvres must be removed to allow the door to be removed. Release the two door latches, located across the top of the door and lift off the lower door bracket. Insert the upper louvres into the slots on both brackets.
9 W415-0377 / C / 09.23.05 PHAZER TM logs and glowing embers, exclusive to Napoleon Fireplaces, provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully position the glowing embers for a maximum glowing effect.
10 W415-0377 / C / 09.23.05 Attach the connectors from the black and white wires to the thermodisc and secure the thermodisc bracket to the secur- ing stud at the bottom left of the unit using a lock washer and wing nut. Ensure that the thermodisc touches the firebox wall.
11 W415-0377 / C / 09.23.05 Attach and secure the sensor assembly bracket to the se- curing stud located next to the receptacle/junction box at the bottom left of the unit using the lock washer and wing nut. Ensure that the thermodisc touches the firebox wall.
12 W415-0377 / C / 09.23.05 • T urn off all gas to the fireplace. • O pen windows. • D o not try to light any appliance. • D o not touch any electric switch; do not use any phone in your building. • I mmediately call your gas supplier from a neighbour's phone.
13 W415-0377 / C / 09.23.05 Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow. Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports.
14 W415-0377 / C / 09.23.05 # PART No. DESCRIPTION 25 GDL42K LOUVRE KIT - UPPER & LOWER - BLACK 25 GDL42PB LOUVRE KIT - UPPER & LOWER - POLISHED BRASS 25 GDL42SS LOUVRE KIT - UPPER & LOWER.
15 W415-0377 / C / 09.23.05 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor. - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed.
16 W415-0377 / C / 09.23.05 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a recommended gas fireplace glass cleaner. DO NOT CLEAN GLASS WHEN HO T. If deposits are not cleaned off regularl y , the glass may become per- manently marked.
Ein wichtiger Punkt beim Kauf des Geräts Napoleon Fireplaces BGNV42P (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Napoleon Fireplaces BGNV42P noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Napoleon Fireplaces BGNV42P - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Napoleon Fireplaces BGNV42P reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Napoleon Fireplaces BGNV42P erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Napoleon Fireplaces BGNV42P besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Napoleon Fireplaces BGNV42P verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Napoleon Fireplaces BGNV42P. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Napoleon Fireplaces BGNV42P gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.