Benutzeranleitung / Produktwartung BGD90NT des Produzenten Napoleon Fireplaces
Zur Seite of 32
1 W415-0580 / C / 04.07.08 $10.00 INSTALLATION AND OPERATION INSTRUCTIONS Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.on.ca CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL STANDARDS: CSA 2.
2 W415-0580 / C / 04.07.08 PG2-5 INTRODUCTION Warning Warranty Fireplace Dimensions Installation Overview General Instructions General Information Care of Glass 6-10 VENTING V enting lengths and Air T.
3 W415-0580 / C / 04.07.08 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON®® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. PA TENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.
4 W415-0580 / C / 04.07.08 6" FIGURE 1 INST ALLA TION O VERVIEW See the section “MINIMUM MANTEL AND ENCLOSURE CLEARANCES” See the section “FRAMING” See the section “VENTING” and “IN.
5 W415-0580 / C / 04.07.08 GENERAL INSTRUCTIONS GENERAL INFORMA TION This gas fireplace should be installed and serviced by a qualified installer to conform with local codes.
6 W415-0580 / C / 04.07.08 * 16” MINIMUM 40 FEET MAXIMUM 3 FEET MINIMUM FIGURE 3b When using Wolf Steel Ltd.venting components, use only approved Wolf Steel Ltd.
7 W415-0580 / C / 04.07.08 VERTICAL RISE IN FEET V T FIGURE 4 See graph to determine the required vertical rise V T for the required horizontal run H T .
8 W415-0580 / C / 04.07.08 H 2 H 1 V 1 90° See graph to determine the required vertical rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .03(two 90° elbows - 90°) = .03(180° - 90°) = 2.
9 W415-0580 / C / 04.07.08 MAXIMUM VERTICAL RISE IN FEET V T HORIZONT AL VENT RUN PLUS OFFSET IN FEET H T The shaded area within the lines represents acceptable values for H T and V T . See graph to determine the required vertical rise V T for the required horizontal run H T .
10 W415-0580 / C / 04.07.08 MINIMUM AIR TERMINAL L OCA TION CLEARANCES . FIGURE 12.
11 W415-0580 / C / 04.07.08 INST ALLA TION / FRAMING WALL AND CEILING PR O TECTION HORIZONT AL VENT SECTIONS: A minimum clearance of 2” all around the vent pipe on all horizontal runs to combustibles is required except for clearances in fi replace enclosures**.
12 W415-0580 / C / 04.07.08 USING FLEXIBLE VENT COMPONENTS ELBOW SP ACERS Do not allow the inside vent pipe to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. A 3/4” air gap be- tween the liner and the outer liner all around is required for safe op- eration.
13 W415-0580 / C / 04.07.08 FLUE COLLAR RESTRICTOR PLA TE FIGURE 23 FIGURE 24 W ARNING THE STANDOFFS HA VE BEEN SHIPPED FLAT . BEFORE FRAMING ENSURE THE STANDOFFS ARE BENT UP AND SCREWED INTO PLACE. A TTENTION A TENCIÓN LAS TRABAS PERMANECEN PLANAS DURANTE EL ENVÍO.
14 W415-0580 / C / 04.07.08 59 1 / 4 " 1" MIN 1" MIN 11 6 " 82" FIGURE 25 FIGURE 28 59 1 / 4 " 29 1/2" 29 1/2" 10" MIN 59 1 / 4 " FIGURE 26 FIGURE 27.
15 W415-0580 / C / 04.07.08 73 1 / 4 " 60 3 / 4 " 5 1 / 2 " 23 3 / 4 " 5 1 / 2 " Use only non-combustible material such as cement board, ceramic tile, marble, etc. when finishing to the fireplace. DO NOT USE WOOD OR DR YW ALL.
16 W415-0580 / C / 04.07.08 RECEIVER Receiver 12 Pin Connector 11 0 V O U T Receiver Hearth Mount OFF ON REMOTE TPTH TP TH FCM-COM FA N A UX O U T Red Black MOTOR Green White Fan Control Module (FCM) .
17 W415-0580 / C / 04.07.08 Before the glass door can be removed, the control doors must be opened and the hearth strip and screen assembly must be removed.
18 W415-0580 / C / 04.07.08 Brick panels are shipped separate from unit due to the brittle material of the bricks, care must be taken not to bend or force them into place. When shipped, the brick panels range in varying shades of Sandstone. During initial use, the panels will darken temporarily .
19 W415-0580 / C / 04.07.08 6. Place the pin in log #7 in the hole in log #6. The log should sit in the notch on log #2 and the bottom should rest along the right side of the Andiron. 8 PHAZER™ logs and glowing embers, exclusive to Wolf Steel Ltd.Fireplaces, provide a unique and realistic glowing ef fect that is different in every installation.
20 W415-0580 / C / 04.07.08 Randomly place the charcoal embers along the front and sides of the Hearth Panels in a realistic manner . Fine dust found in the bottom of the bag should not be used. Sprinkle vermiculite around the charcoal embers. NOTE: Both charcoal embers and vermiculite are not to be placed on the burner .
21 W415-0580 / C / 04.07.08 RECEIVER SLOT SP ARK MODULE VA LV E WING NUT INNER ACCESS PA N E L 1. Remove access panel from inside the fi rebox. 2. Unplug the control module from the junction box 3. Pull up on the control module being held down with velcro and disconnect the plugs (fan, aux).
22 W415-0580 / C / 04.07.08 FIGURE 49 HAND HELD REMO TE OPERA TIONS 1. Install 4 AA batteries into the receiver battery bay as indicated on the battery cover (+/-).
23 W415-0580 / C / 04.07.08 1. Press the Thermostat Key . The LCD display on the T ransmitter will show that the room is “ON” and the set temperature is now displayed. 2. T o adjust the set temperature, press the Up/Down Arrow Keys until the desired set tem- perature is displayed on the LCD screen of the T ransmitter.
24 W415-0580 / C / 04.07.08 LO W BA TTER Y / MANU AL BYP ASS The life span of the remote batteries depends on various factors: quality of the batteries, the number of ignitions, the number of changes to the room thermostat set point, etc.
25 W415-0580 / C / 04.07.08 A. This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly . B. Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor .
26 W415-0580 / C / 04.07.08 Purg e all gas lines with the glass door of the f ire place remo ved. Assur e that a contin uous gas flow is a t the burner befor e installing the door . TURN OFF THE G AS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPL ACE.
27 W415-0580 / C / 04.07.08 67* W573-0007 HI-TEMP SEALANT 68* GD501 HEA T GUARD 69 GA-566 HOT AIR DISTRIBUTION KIT 70 GA-72 HOT AIR EXHAUST KIT 71 GA-70 EXTENSION KIT , 5FT FLEX VENT 72* W010-0370 W A.
28 W415-0580 / C / 04.07.08 6 4** 8 7 5 41 23 28 29 30 31 35 27 26 34 64 33 66 32 11 65 21 2 15 16 12 3 14 19 17 71 55 58 22 79 63 69 70 13.
29 W415-0580 / C / 04.07.08 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a gas fi replace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned off regularly , the glass may become per- manently marked.
30 W415-0580 / C / 04.07.08 Main burner goes out; pilot goes out. Main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engulfi ng the thermo- pile - turn up pilot fl ame. - replace pilot assembly . Thermopile shorting - clean thermopile connection to the valve.
31 W415-0580 / C / 04.07.08 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS.
32 W415-0580 / C / 04.07.08 NO TES.
Ein wichtiger Punkt beim Kauf des Geräts Napoleon Fireplaces BGD90NT (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Napoleon Fireplaces BGD90NT noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Napoleon Fireplaces BGD90NT - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Napoleon Fireplaces BGD90NT reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Napoleon Fireplaces BGD90NT erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Napoleon Fireplaces BGD90NT besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Napoleon Fireplaces BGD90NT verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Napoleon Fireplaces BGD90NT. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Napoleon Fireplaces BGD90NT gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.