Benutzeranleitung / Produktwartung Arlington GDS20N des Produzenten Napoleon Fireplaces
Zur Seite of 28
1 W415-0496 / B / 08.10.05 W415-0496 / B / 08.10.05.
2 W415-0496 / B / 08.10.05 WHA T T O DO IF Y OU SMELL GAS WARNINGS & SAFETY PRECA UTIONS.
3 W415-0496 / B / 08.10.05 WARNING • The sto ve is a vented g as-fi r ed hea ter . Do not b urn wood or other materials in this sto ve . • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
4 W415-0496 / B / 08.10.05 NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
5 W415-0496 / B / 08.10.05 Expansion / contraction noises during heating up and cool- ing down cycles are normal and to be expected. This appliance is only for use with the type of gas indicated on the rating plate . This appliance is not convertible for use with other gases, unless a certified kit is used.
6 W415-0496 / B / 08.10.05 MAINT AIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES: A. 4" B. 2" * C. 2" STOVE SHOULD NOT BE INST ALLED DIRECTL Y ON CARPETING . MINIMUM 48" FROM STOVE TOP TO CEILING TO CEILING FROM STOVE TOP ............
7 W415-0496 / B / 08.10.05 BLO WER INST ALLA TION Blower ( SEE LOCATION AND CLEARANCES ) 1. Cut and remove the tie securing the blower switch wires to the heat shield. 2. Connect the white wire coming from below the unit to the terminal on the blower .
8 W415-0496 / B / 08.10.05 AIR TERMINAL INST ALLA TIONS * * * * * Recommended to prevent condensation on windows and thermal breakage * * * * * * * * * * It is recommended t o use a heat shield and to maximize the distance to vinyl c lad sof fits .
9 W415-0496 / B / 08.10.05 Use only Wolf S teel, Simpson Dura-V ent, Selkirk Direct T emp or American Met al Amerivent venting components. For Simpson Dura-V ent, Selkirk Direct T emp and American Metal Amerivent, follow the installation procedure provided with the venting components.
10 W415-0496 / B / 08.10.05 Use the GD201 periscope kit to locate the air termination above grade. The periscope must be installed so that when final grading is completed, the bottom air slot is located a minimum of 12 inches above grade. The maximum allow- able vent length depends on the fireplace, as illustrated.
11 W415-0496 / B / 08.10.05 ELBO W VENT LENGTH V AL UES DEFINITIONS HORIZONT AL TERMIN A TION REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE .
12 W415-0496 / B / 08.10.05 V 1 HORIZONT AL TERMINA TION See graph to determine the re- quired vertical rise V T for the re- quired horizontal run H T . For vent configurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.
13 W415-0496 / B / 08.10.05 VERTICAL TERMIN A TION Example 3: V 1 =5 f t V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 =3 f t H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.
14 W415-0496 / B / 08.10.05 H 1 VERTICAL TERMIN A TION For vent configurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2: H.
15 W415-0496 / B / 08.10.05 This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum rectangle opening of 10" x 9". IMPORT ANT : FOR OPTIMUM PERFORMANCE, THE STOVE PIPE SHOULD RISE ¼" PER FOOT OF RUN.
16 W415-0496 / B / 08.10.05 4. If more than one length of liner needs to be used to reach the stove, couple them together as illustrated in FIGURE 24 . Seal the joints using the same procedure as described above. The vent system must be supported approximately every 10 feet along a horizontal run.
17 W415-0496 / B / 08.10.05 1. Attach the adjustable pipe to the last section of rigid piping. Secure with screws and seal. 2. Install the 4" aluminium flex- ible liner to the stove. Secure with 3 screws and flat wash- ers. Seal the joint and screw holes using high tempera- ture sealant.
18 W415-0496 / B / 08.10.05 1. Lift the top cast piece off of the unit. 2. Detach the front cast piece from the side pieces by removing the screws from the brackets located in the upper inside corners.
19 W415-0496 / B / 08.10.05 LOG PLACEMENT LOGO PLACEMENT Remove the backing from the the logo and position onto the control door as shown. It is not necessary to rem ove the cast fr ont, however , this will make for a more simple log installation.
20 W415-0496 / B / 08.10.05 Purge all gas lines with the glass door removed. Assure that a continuous gas flow is at the burner before closing the door . The on-off switch is located on the back of the unit at the top right corner on model GDS20. When lit for the first time, the fireplace will emit a slight odour for a few hour s .
21 W415-0496 / B / 08.10.05 Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow . FIGURE 34 FIGURE 35 Air shutter adjustment must only be done .
22 W415-0496 / B / 08.10.05 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor . When ordering replacement parts always give the fol- lowing information: 1.
23 W415-0496 / B / 08.10.05 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
24 W415-0496 / B / 08.10.05 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed.
25 W415-0496 / B / 08.10.05 Main burner goes out; pilot goes out. REFER TO "MAIN BURNER GOES OUT ; PILOT ST A YS ON" Thermocouple shorting or faulty . V ent re-circulating - check joint seals and installation. - loosen and tighten thermocouple - clean thermocouple and valve connection.
26 W415-0496 / B / 08.10.05 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Deale.
27 W415-0496 / B / 08.10.05 NO TES.
28 W415-0496 / B / 08.10.05 NO TES.
Ein wichtiger Punkt beim Kauf des Geräts Napoleon Fireplaces Arlington GDS20N (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Napoleon Fireplaces Arlington GDS20N noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Napoleon Fireplaces Arlington GDS20N - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Napoleon Fireplaces Arlington GDS20N reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Napoleon Fireplaces Arlington GDS20N erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Napoleon Fireplaces Arlington GDS20N besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Napoleon Fireplaces Arlington GDS20N verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Napoleon Fireplaces Arlington GDS20N. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Napoleon Fireplaces Arlington GDS20N gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.