Revision 1.3 Page i ® ® FPM100 Fluid Pressure Monitor User’s Manual Revision 1.3 Copyright © 2012 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N.
FPM100 User’s Manual Page ii Revision 1.3 Revision History Revision Description 1.0 Original document 1.2 Corrected accessory table and added new sensors 1.
Revision 1.3 Page iii ® ® Table of Contents 1 General ....................................................................................................................... ......... 1 1.1 Introduc tion .................................
FPM100 User’s Manual Page iv Revision 1.3 Table of Figures Figure 1 - Graph of Transducer Accuracy vs. Tank Depth ......................................................... 4 Figure 2 - Pressure Transducer Selectio n Chart for Tank Level Applications .
Revision 1.3 Page 1 ® ® 1 General 1.1 Introduction Congratulations on your purchase of the Maretr on Fluid Pressure Moni tor (FPM100). Maretron has designed and built your monitor to the highes t standards for years of reliable, dependable, and accurate service.
FPM100 User’s Manual o 16 programmable tank types includi ng Fuel, Fresh Water, Waste Water o Programmable tank number(s ) up to 16 per tank type o Programmable tank capacity 1.4 FPM100 Accessories Maretron offers the following accessories for the FPM100: • PT-V-0-1BAR-01 Pressure Transducer Vacuum to 1 Bar (14.
Revision 1.3 Page 3 ® ® o Configure for Tank Depth and Shape Configure or Program the Tank Depth (Section 3.3.5.1 ) Custom Calibration (Section 3.3.5.2 ) 1.6 Theory of Operation The FPM100 operates by measur ing the current transmitted by pressure transducers.
FPM100 User’s Manual Figure 1 - Graph of Transducer Accuracy vs. Tank Depth The pressure transducer you select must have su fficient range to measure the full height of the liquid column of a fu ll tank. The table in Figure 2 below shows the maximum depth that can be sensed by each pressure transducer type.
Revision 1.3 Page 5 ® ® 2.2 Choosing a Mounting Location Please consider the following wh en choosing a mounting location. 1. The FPM100 is waterproof, so it c an be mounted in a damp or dry location. 2. The orientation is not important, so the FPM100 can be mounted on a horizontal deck, vertical bulkhead, or upside down if desired.
FPM100 User’s Manual Keep in mind that the rated burst pressure of the pressure tr ansducer is 2.4 to 3 times the maximum measurement pressure of the transducer.
® ® Pressure Transducer Ball Valve Tank Fitting 2.5 Connecting the FPM100 The FPM100 requires two types of elec trical connections: 1) the NMEA 2000 ® connection (refer to Section 2.5.1 ), and 2) the pressure transducer c onnections, which are described in Section 2.
FPM100 User’s Manual Figure 6 – NMEA 2000 ® Connector Face Views 2.5.2 Pressure Transducer Connections The FPM100 pressure transducer connections ar e made by connecting to the 12-pin terminal strip on the top of the unit. First, remove the f our screws at the corner s of the unit detaching the splash guard from the unit.
Revision 1.3 Page 9 ® ® 3 Configuring the FPM100 The FPM100 has several configurable paramete rs, which are shown below including the default values. If you are not using the defaul t values, then you will need to refer to the corresponding section for confi guring the FPM100 appropriately.
FPM100 User’s Manual Page 10 Revision 1.3 3.2.2 Configuring Label Program this parameter with a text string which identifies t he particular parameter being monitored by this channel. Maretron display products will display this label text when yo u are selecting data to display.
Revision 1.3 Page 11 ® ® 3.3.2 Configuring Pressure at 4mA Program this parameter to matc h the pressure reading of the pr essure transducer when it is sourcing a current of 4mA. You can determine this value by examining t he specification of the pressure transducer being used.
FPM100 User’s Manual Empty Tank Depth Full Tank Depth Figure 8 – Empty Tank Depth and Full Tank Depth Parameters 3.3.5.1.3 Fluid Density In order for the FPM100 to properly convert pressure readings to tank levels using a rectangular tank calibration, it must be configured with the density of the fluid being monitored.
Revision 1.3 Page 13 ® ® 3.3.7 Configuring Tank Type As shipped from the factory, the FPM100 transmits the ta nk type as “Fuel”. You can reconfigure the FPM100 for any of these tank types: 1. Fuel 2. Fresh Water 3. Waste Water 4. Live Well 5. Oil 6.
FPM100 User’s Manual Page 14 Revision 1.3 5 Troubleshooting If you notice unexpected operation of the Mare tron FPM100, follow the troubleshooting procedures in this section to remedy simple problems. Symptom Troubleshooting Procedure No Pressure data visible on NMEA 2000 ® network.
Revision 1.3 Page 15 ® ® Figure 9 – Troubl eshooting Guide If these steps do not solve your problem, please contact Maretr on Technical Support (refer to Section 7 for contact information). 6 Technical Specifications Specifications (Tank Level Mode) Parameter Value Comment Accuracy +/-1% FS Exclusiv e of Pressure Tra nsd ucer Resolution +/-0.
FPM100 User’s Manual Page 16 Revision 1.3 Electrical Parameter Value Comment Operating Voltage 9 to 32 Volts DC Voltage Power Consumption 400mA Maximum Current Drain Load Equivalence Number (LEN) 8 NMEA 2000 ® Spec.
® ® 8 Installation Template Please check the dimensions before using the fo llowing diagram as a template for drilling the mounting holes because the printing proc ess may have distorted the dimensions. Figure 10 – Mounting Surface Template Revision 1.
FPM100 User’s Manual Page 18 Revision 1.3 9 Maretron (2 Year) Limited Warranty Maretron warrants the FPM100 to be free from defects in materia ls and workmanship for two (2) years from the date of original purchase.
Revision 1.3 Appendix A – NMEA 2000 ® Interfacing Page A1 ® ® Appendix A – NMEA 2000 ® Interfacing FPM100 NMEA 2000 ® Periodic Data Transmitted PGNs PGN 130314 – Actual Pressure The FPM100 uses this PGN to provide a regul ar transmission of various pressures.
Ein wichtiger Punkt beim Kauf des Geräts Maretron FPM100 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Maretron FPM100 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Maretron FPM100 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Maretron FPM100 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Maretron FPM100 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Maretron FPM100 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Maretron FPM100 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Maretron FPM100. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Maretron FPM100 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.