Benutzeranleitung / Produktwartung OXY8_050503 des Produzenten M-Audio
Zur Seite of 24
User Guide Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Oxygen 8 Featur es . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Oxygen 8 Overview . . . . . . . . . .
Introduction Congratulations on your pur chase of the Oxygen 8, par t of the USB K eystation series of MIDI controllers br ought to y ou by M-Audio .Y ou ma y use your Oxygen 8 in conjunction with a USB equipped PC or Macintosh computer and a ppr opriate music softwar e to enter a full range of MIDI note and controller information.
Contained within the Oxygen 8 is a USB MIDI interface. Simply plug the Oxygen 8 into your computer’ s USB por t, install the included drivers and enable the MIDI interface within your m usic software.
Guide to Getting Started Here’ s an outline of steps to begin using your Oxygen 8 on either Mac or PC: 1. Attach the Oxygen 8 to your computer (see “Hardwar e Installation”). 2. Install the Driver (see “Software Installation”). 3. Hook your sound module to the Oxygen 8 (see “Setting Up Y our MIDI Studio”).
To v erify your Windows installation after you ha v e carefull y follow ed these instructions, you ma y check y our system’ s “Device Manager , ” located in the Control Panel under “System.
7. Y ou will see a “New Har dware found” dialog. (If you don’ t see this dialog at first, unplug y our Oxygen 8 and tr y again.) Click Next. 8. Y ou will see another warning that the product has not passed Windows logo testing. Click "Continue an ywa y".
11. Again, the computer reminds y ou that the product has not passed Windows Logo testing. Click "Continue anywa y". 12. The driv er has been installed. Windows XP Installation is now complete. W indows 2000 1. Ser vice Pack 2 or higher is r equir ed for pr oper operation of the Oxygen 8 driver .
The installer will scan your har d drive (this can tak e some time) and will then install the necessar y files and perform setup actions on your system. A series of progr ess bars will show y ou how the pr ocess is going. 6. At the next prompt, the installer will warn you that this product does not ha ve a Windows Digital Signature.
10. The installer will warn y ou again, a second time , that this product does not ha ve a Windows Digital Signature - again, click “Y es. ” 11. The next scr een informs you that the installer has completed. Click “Finish” to continue. 12. Windows 2000 will prompt y ou to r estar t the computer , in order to complete the installation.
click “Next” to continue. The installer will scan your har d drive (this can tak e some time) and will then install the necessar y files and perform setup actions on your system. A series of progr ess bars will show y ou how the pr ocess is going.
system OS 9.2.2 or higher . Some updates ar e offer ed free to Apple owners. Please check the Apple website at http://www .info .apple.com for update information.
First Time OMS Configuration Instructions If you ha v e installed the Oxygen 8 in Mac OS 9, it is now time to configur e OMS (this is not necessar y in Mac OS X). Go to the Chooser under the Apple Menu, and mak e sur e AppleT alk is turned off (this is recommended, although OMS will sense that it is on and prompt y ou to turn it off).
1. The Oxygen 8 is connected to the computer via the USB port connectors, using the supplied USB standard cable. 2. The Oxygen 8 can pla y the synthesizer that is part of an internal sound card, as well as an y softwar e synthesizers that are installed in y our system.
Using the Oxygen 8 in your Application Software Once the Oxygen 8 driver has been installed, y ou will need to configure y our MIDI application softwar e to utilize the Oxygen 8. The manner in which this is done varies between a pplications, so we can just cov er the basics her e .
1. Po wer up the Oxygen 8, using either a 9vDC adapter or using 6 AA batteries. Set the pow er switch to the the 9V/Batter y setting. If a 9V pow er adapter is present, the Oxygen 8 will use power fr om the adapter . If a 9V adapter is not present, and the Oxygen 8 has the requir ed battery power , the unit will pow er up using the batteries.
manuals of y our devices for inf ormation on how to change the Pitch Bend range. T o bend the pitch up, mov e the wheel a wa y from y ou. T o bend the pitch down, move the wheel towar ds you.
F or example, if you want to change the value of the velocity offset, first press the MIDI/SELECT button and then the velocity k e y . Second, change the data entr y slider to the value you want. Finally , press the MIDI/SELECT button again to finish the change.
“Flat” & “Sharp” keys: By pr essing the MIDI/SELECT button and the flat or the sharp k ey , you will shift the activ e k e yboar d pitch one note (half-step) higher , or low er . For example, if you want to change the pitch 2 notes do wn, press MIDI/SELECT button and the “flat” key twice.
Rear Panel 1. Sustain jack: This jack allows you to connect an optional foots witch to the ke yboard. When the footswitch is depr essed, notes play ed on the k eyboard will continuously sound as long as the f ootswitch is held, while MIDI controller inf ormation is sent from the Oxygen 8.
20 Specifications Model: Oxygen 8 Keyboard T ype 25 dynamic key Simultaneous Output 10 note (reverse priority) Control Switches MIDI Channel Reset Octave -2, -1, center , +1, +2 Program Change CC-00/CC-32 (GS Bank Selection) CC-No.
T echnical Support & Contact Information F or additional technical assistance, contact M-Audio T echnical Suppor t by telephone (626-445-8495, 9-5 PST M-F), by fax (626-445-7564) or by e-mail (techsupt@m-audio .
Appendix A-Midi Charts MIDI Controllers: Number Definition Parameter 0 Bank Select 0-127 1 Modulation Wheel 0-127 2 Breath Control 0-127 3U ndefined 0-127 4F oot Controller 0-127 5P ortamento Time 0-1.
MIDI Implementation: Model: Oxygen 8 V ersion: 1.0 Function T ransmitted Recognized Remarks Basic Channel Default 1 x Changed 1-16 x Mode Default Mode 3 x Messages x x Altered ************* x Note Num.
Oxygen 8 W arranty Information M-Audio warrants that this pr oduct is free of def ects in materials and w orkmanship under normal conditions f or 90 da ys, so long as the pr oduct is: o wned by the or.
Ein wichtiger Punkt beim Kauf des Geräts M-Audio OXY8_050503 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie M-Audio OXY8_050503 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für M-Audio OXY8_050503 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von M-Audio OXY8_050503 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über M-Audio OXY8_050503 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon M-Audio OXY8_050503 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von M-Audio OXY8_050503 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit M-Audio OXY8_050503. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei M-Audio OXY8_050503 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.