This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
2 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Dr ywall T op Of Firepl ace Opening Non-Combus tible Figure 1 T ABLE OF CONTENTS Packaging ......................................... Page 2 Introduction ...................................... Page 2 General Information .
3 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Model Orifice Size El e v at i on F e et ( m et e r s ) Nat. Prop. LSM40-2 .1405" (#28) .
4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. New Y ork City , New Y ork (MEA) Installation of these fireplaces are approved for installation in New York City in the US state of New Y ork.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 5 Figure 2 Figure 3 *Note: See Page 6, Step 1 for clearance requirements to the nailing flange located at each side of the unit and any screw heads adjacent to it. The appliance should be mounted on a fully supported base extending the full width and depth of the unit.
6 Unit Being Secured by Its Nailing Flanges to the Framing Figure 6 Step 1. ( Page 6 ) Construct the appliance fram- ing. Position the appliance within the framing and secure with nailing brackets. Step 2. ( Page 6 ) Route gas supply line to the right side of the appliance.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 7 EXTERIOR HORIZONT AL VENT TERMINA TION CLEARANCE REQUIREMENTS Mi n i mu m Cl e a ra n ce s Ca n a di a n I n s ta l la t i on * US I ns t a ll a t io n * * A = Cle a ra nc e abo v e gr a de , ver a nd a, po r ch , dec k or ba lc o ny .
8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. C Back wall of chase/enclosure (including any finishing materials) D A B Model No. A B C D LSM40-2 in. 50-5/8 83-5/8 59-1/8 41-7/8 mm 1286 2124 1502 1064 LSM45-2 in. 56-3/4 89-7/8 63-1/2 44-7/8 mm 1441 2283 1613 1140 Model No.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 9 E A B D T op View Front View 5-3/32 (129) Right Side View 14-1/8 8-1/2” (216) 5-1/4” (133) (359) 26-15/32 (672) C 25-29/32 (658) 25-1/2 (648) 7 2-1/2 (64) (178) 19-5/8 (498) Gas Inlet (This Side Only) Electrical Inlet 8-3/8 (213) F G H J M o d e l N o .
10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Remove the word "of" from sentence (in red below) (done 8-1-07) T ermination Flashing An d Storm Collar Fires top/Spacer SV 8 6/12/24/36/48 V ent Section s 40' Ma x (12.2 M) 6' Mi n (1.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 11 T R A H C H T G N E L N O I T C E S T N E V l a n i m o N h t g n e L n o i t c e S ) s e h c n i ( 6 2 1 4 2 6 3 8 4 T O T A L Q T Y n o i t c.
12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. First Vent Component Align the dimple (four places) with the opening of the locking incline channel on appliance collar .
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 13 Fr a m in g D i me n si o n s f or Ro o f In c h es (m i ll i me t e rs ) Pi t c h C D 0/ 1 2 1 3 i n. (3 3 0 m m ) 13 i n. (3 3 0 m m ) 6/ 1 2 1 3 i n. (3 3 0 m m ) 15 - 1 /2 in . (3 9 4 m m ) 12 / 1 2 13 in .
14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 24 - T op Vent - THREE ELBOWS V H 1 H V 1 Ceiling Firestop/Spacer (SV8BF) Wall Firestop/Spacer (SV8HF) T a bl e B H + H 1 M a xi m u m V M in i mu m fe e t ( me t er ) fe e t ( me t er ) 10 (3 .
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 15 Vertical Rise SV8E90 Elbow Horizontal / Inclined Run SV8HTS T ermination Shown Firestop/Spacer SV8 L6/12/24/36/48 Vent Sections Support Bracket.
16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 26 Figure 27 Installing the Square Horizontal T ermination (SV8HTS) Firestop/Spacer (SV8HF) shown on the exter ior side of the wall. It may also be installed on the interior side. SV8HTS T ermination Shown.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 17 H V Wall Firestop/Spacer (SV8HF) Ceiling Firestop/Spa ce r (SV8BF) T a bl e C H M a xi m um V M i n im u m fe e t (m e t er ) f ee t (m e t er ) 3. 5 ( 1 .0 7 ) 2. 5 ( 0 .7 6 2) 6. 5 (1 .9 8 ) 3.
18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 30 - T op Vent - THREE 90 DEGREE ELBOWS See T able 6 on Page 17 as an aid in venting component selection for a particular range of exterior wall thicknesses.
19 CAUTION Ground supply lead must be connected to the wire attached to the green ground screw located on the outlet box. See Figures 32A and 32B . Failure to do so will result in a potential safety hazard.
20 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Step 5. REMOVING GLASS DOOR FRAME ASSEMBL Y Refer to Figure 37 on Page 21 and remove the front glass door assembly as follows: T o remove the .
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 21 Figure 35 ELECTRONIC Flame Sensor Hood Ignitor Rod Pilot Nozzels Glass Door Latch (2) Glass Door Assembly Firebox Floor T op Flange Glass Door .
22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Air Shutter Opening Burner Orifice Gas Valve Venturi Venturi Main Burner Factory Air Shutter Opening Setting - Inches (millimeter) Model Nat.Gas Propane Gas LS M4 0- 2 1/ 16 ( 1.5 9) 9/32 ( 7. 14 ) L S M 4 5- 2 1/ 16 ( 1.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 23 Glass Door Assembly Fireplace Finish Combustible Or Non-Combustible Material Bottom Of Fireplace 1/8 Inch Minimum Door T rack Finish Combustible Or Non-Combustible Material Front Face Of Fireplace Floor Panel Figure 41 Figure 40 A hearth extension is not required with this appliance.
24 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 43 17" 14" 8-1/4” 45° 12" 5" 12 (305) MANTEL 10 (254) MANTEL 8 (203) MANTEL 6 (152) MANTEL 4 (102) MANTEL 7 (178).
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 25 INST ALLA TION ACCESSORIES Listed Secure Vent™ Components Cat. No. Model No. Description H2266 SV8HTS Horizontal Square T ermination with Fir.
26 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. IMPOR T ANT/CANADA Th e co n ve r si o n sha l l be car r ie d ou t in acc o r da n ce wit h t he req u ir e me n ts of the pro v in c ia l au th o r it i es ha v in g ju r is d ic t i on an d in acc o rd a nc e wi th th e re q u ir e m en t s of th e CA N 1- B 1 49 .
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 27 Figure 47 Step 8. Reassemble the remaining components by reversing the procedures outlined in the preceding steps. Step 9. Attach the conversion label provided in the conversion kit to the rating plate on the appliance.
Printed in U.S.A. © 2005 by Lennox Hearth Products P/N 850,026M REV . D 08/2007 Lennox Hearth Products reser ves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
Ein wichtiger Punkt beim Kauf des Geräts Lennox Hearth Products Montebello LSM40MN-2 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Lennox Hearth Products Montebello LSM40MN-2 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Lennox Hearth Products Montebello LSM40MN-2 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Lennox Hearth Products Montebello LSM40MN-2 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Lennox Hearth Products Montebello LSM40MN-2 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Lennox Hearth Products Montebello LSM40MN-2 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Lennox Hearth Products Montebello LSM40MN-2 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Lennox Hearth Products Montebello LSM40MN-2. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Lennox Hearth Products Montebello LSM40MN-2 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.