Benutzeranleitung / Produktwartung Modero MVP-5150 des Produzenten AMX
Zur Seite of 176
Operation/Reference Guide Mio Modero Touch Panels MVP-5100/5150 Modero® Viewpoint Widescreen Touch Panels Last Updated: 12/2/200 8.
AMX Limited Warranty and Disclaimer All products returned to AMX re quire a Return Mate rial Authorization (RMA) n umber . The RMA number is obtained from the AMX RMA Department. The RMA number must be clear ly marked on the outside of each box. The RMA is valid for a 30-day period.
FCC Information This device complies with Part 15 of the FCC Rul es and Industry Canada RSS 210, subject to the following two conditions: (1) this devi ce may not cause harmful interfe ren ce, and (2) this device must accept any interference received; including interference that may cause undesired operatio n.
Software License and Warranty Agreement • LICENSE GRANT . AMX grants to Licensee the non-exclusive right to use the AMX Software in the manner described in this License. The AMX Software is licensed, no t sold. This license does not grant Licensee the right to create derivative wor ks of t he AMX Software.
Table of Contents i MVP-5100/5150 Modero Viewpoint Tou ch Panels Table of Contents Introduction .................. ...................................................................... ................ 1 MVP-5150 5.2" Modero Vi ewPoint WiFi Touch Panel .
ii MVP-5100/5150 Modero Viewpoint Touch Panels Table of Contents Automatically settin g SSID .............. ............. ................ ................. ............. ................ ... 29 Manually settin g SSID ................ ................
Table of Contents iii MVP-5100/5150 Modero Viewpoint Tou ch Panels Upgrading Firmware ........................... ............................................... .............. 85 Upgrading the Modero Firmware via the USB por t .................... ..
iv MVP-5100/5150 Modero Viewpoint Touch Panels Table of Contents Input mask outpu t examples ........................ ................ ............. ................. ................ . 15 4 URL Resources .................. ......................... .
Introduction 1 MVP-5100/5150 Modero Viewpoint Touch Panels Introduction The MVP-5100 Modero® V iewpoint® IR T ouch Panel ( FG5966-08 ) and the MVP-5150 Modero® V iewpoint® W iFi T ouch Panel ( FG5966-07 ) are wireless er go nomic de vices, with all control established through a NetLinx Master or through an IR recei ver .
Introduction 2 MVP-5100/5150 Modero Viewpoint Touc h Panels MVP-5150 5.2" Modero ViewPoint WiFi Touch Panel MVP-5150 Specifications (FG 5966-07) Dimensions: 4 3/4" x 7 9/16" x 13/16" (120.7 mm x 191.8 mm x 20.3 mm) Wei gh t : • 1.
Introduction 3 MVP-5100/5150 Modero Viewpoint Touch Panels MVP-5150 Specifications (FG 5966-07) (Cont.) External Components Connector: 5-pin Mini-USB connector used for output to USB programming, f irmware update, and touch panel file transfer between the PC and the target panel.
Introduction 4 MVP-5100/5150 Modero Viewpoint Touc h Panels MVP-5100 5.2" Modero ViewPoint IR Touch Panel The MVP-5100 differs from the MVP-5150 in that it does not have a built-in wireless card or the capacity to install one, and only communicates with other de vices via IR.
Introduction 5 MVP-5100/5150 Modero Viewpoint Touch Panels Memory The MVP-5100 and MVP-5150 com e with 128MB of Mobile DDRAM memory and 256 MB NAND Flash memory .
Introduction 6 MVP-5100/5150 Modero Viewpoint Touc h Panels Basic Operation The MVP-5100 and MVP-5150 are operated using their integral touchscreens. If the device has shut down, a touch of the touchscreen will reacti v ate it.
Accessories 7 MVP-5100/5150 Modero Viewpoint Touch Panels Accessories Table Charging Station The MVP-5100 and MVP-5150 may be used with the MVP-TCS-52 T able Charging Station ( FG5966- 1X ) (FIG. 4), which acts both as a char ging station and a direct po wer connection.
Accessories 8 MVP-5100/5150 Modero Viewpoint Touc h Panels Powering the MVP-TCS -52 The MVP-TCS-52 uses a PS3.0 power supply (included with th e touch panel or available separately from www .amx.com ) to provide direct po wer for the MVP panel both for standard functions and for charging its internal battery .
Accessories 9 MVP-5100/5150 Modero Viewpoint Touch Panels Wall Charging Station The optional MVP-WCS-52 W all Charging Station ( FG5966-1X ) offers the same rechar ging and connection features as the .
Accessories 10 MVP-5100/5150 Modero Viewpoint Touc h Panels The touch panel remains locked in the MVP-WCS-52 until unlocked by the user . This may be done by entering an appropriate password (please r.
Accessories 11 MVP-5100/5150 Modero Viewpoint Touch Panels Recharging T o recharge the touch panel: 1. Slide the de vice into the W all Charging Station cradle bottom-first and make sure the de vice is fully seated in the Charging Station. 2. Press the top of the touch panel back until it clicks .
Accessories 12 MVP-5100/5150 Modero Viewpoint Touc h Panels Installing the MVP-WCS-52 Since the W all Charging Station is intended to be af f ixed to a w all or other permanent structure, care must be taken to ensure its proper installation to pre vent potential damage to an y touch panel placed within.
Accessories 13 MVP-5100/5150 Modero Viewpoint Touch Panels 3. Run the power cable through the knockout into the box. Pull out about six inches (15.25cm) of cable into the box to facilitate installation of the MVP-WCS-52.
Accessories 14 MVP-5100/5150 Modero Viewpoint Touc h Panels Strip 0.25 inch (6.35 mm) of wire insulation of f all wires. Insert each wire into the a ppropriate opening on the connector . T urn the scre ws clockwise to secure the wires in the connector .
Accessories 15 MVP-5100/5150 Modero Viewpoint Touch Panels 11. After fully seating the screws, wipe do wn the area around the screw holes with the alcohol prep pad from the Installation Kit. T ake a rubber foot and remove its adhesi ve backing. Put the foot, adhesive- side down, in the slot surrounding the screw hole in the W all Charging Station.
Accessories 16 MVP-5100/5150 Modero Viewpoint Touc h Panels Installing the Optional Meta l Rough-In Box The optional Metal Rough-In Bo x (FG037-11) is 10 in ches (25.40 cm) wide at its widest dimension (wider than the bezel of the W all Charging Station), and is only intended for pre construction installations (FIG.
Accessories 17 MVP-5100/5150 Modero Viewpoint Touch Panels Other MVP-WCS-52 i nstallations The W all-Mounted Charging Station is designed to be installed in various dif fere nt locations, such as into the face of a w ooden podium or the top of a table.
Accessories 18 MVP-5100/5150 Modero Viewpoint Touc h Panels.
Configuring Communication 19 MVP-5100/5150 Modero Viewpoint Touch Panels Configuring Communication All control for a MVP-5150 touch panel is established through a NetLinx Master . Communication between the MVP and the Master consists of using eith er W ireless Ethernet (DHCP , Static IP) or USB.
Configuring Communication 20 MVP-5100/5150 Modero Viewpoint Touc h Panels IR Communication Both the MVP-5100 and MVP-5150 may be used as infrared remote de vices for other AMX controllers or third-party de vices. The de vices can transmit IR ov er 20 feet (6.
Configuring Communication 21 MVP-5100/5150 Modero Viewpoint Touch Panels Modero Setup and System Settings All AMX Modero panels, including the MVP-5100 an d MVP-5150, feature on-board Setup pa ges. Use the options in the Setup pages to access panel information and make v arious configuration changes.
Configuring Communication 22 MVP-5100/5150 Modero Viewpoint Touc h Panels For more information on the Setu p and Pr otected Setup pages, refer to the Setup P ag es section on page 45 and the Pr otected Setup P ages section on page 55. Setting the Panel’ s Device Number In the Pr otec ted Setup page: 1.
Configuring Communication 23 MVP-5100/5150 Modero Viewpoint Touch Panels Wireless Settings - Wireless Access Overview (MVP-5150 Only) DHCP When choosing DHCP , a DHCP server must be accessible before the fields are populated. The parameters of the wireless car d must be set before selecting Ethernet as the Master Connection T ype.
Configuring Communication 24 MVP-5100/5150 Modero Viewpoint Touc h Panels Wireless communication using a DHCP Address In the Pr otec ted Setup page: 1. Select Wir eless Settings . W ireless communication is set within the IP Settings section of this page (FIG.
Configuring Communication 25 MVP-5100/5150 Modero Viewpoint Touch Panels Wireless communic ation using a Static IP Address 1. From the Pr otected Setup page, press the Wireless Settings b utton to open the Wir eless Settings page. W ireless communication is set within the IP Settings section of this page (FIG.
Configuring Communication 26 MVP-5100/5150 Modero Viewpoint Touc h Panels Using the Site S urvey tool This tool allows a user to "snif f out" all transmitting W ireless Access Points within the detection range of the internal wireless card (FIG.
Configuring Communication 27 MVP-5100/5150 Modero Viewpoint Touch Panels 4. Select a desired Access Point by touching the co rresponding row . The up arrow and down arro w will be grayed out if ten or fewe r access points are detected. If more are detected, then the y will be enabled as appropriate so that the user can scroll through the list.
Configuring Communication 28 MVP-5100/5150 Modero Viewpoint Touc h Panels 5. In this keyboard, enter the SSID name used on the ta rget W ireless Access Po int ( case sensitive ). The card should be gi ven t he SSID used by the target W AP . If this field is left blank, the unit will attempt to connect to the first a vailable W AP .
Configuring Communication 29 MVP-5100/5150 Modero Viewpoint Touch Panels 6. Click Done when complete. 7. From the Open (Clear T ext) Settings page (FIG. 19), press the Save b utton to incorporate the new information into the device and begin the communication process.
Configuring Communication 30 MVP-5100/5150 Modero Viewpoint Touc h Panels 2. Locate the W ir eless Security menu (FIG. 21). 3. Press the Static WEP b utton to open the Static WEP Settings dialog (FIG.
Configuring Communication 31 MVP-5100/5150 Modero Viewpoint Touch Panels 6. T oggle the D efault Key field to choose a WEP K ey v alue ( from 1- 4 ) that matches what will be used on the target. This value MUST MA TCH on both devices . These WEP K ey identif ier values must match f o r both de vices.
Configuring Communication 32 MVP-5100/5150 Modero Viewpoint Touc h Panels 12. V erify that the fields within the IP Settings section ha ve been properly conf igu red. Refer to Step 1: Configur e the Device’ s W ir eless IP Settings (MVP-5150 Only) section on page 23 for detailed information.
Configuring Communication 33 MVP-5100/5150 Modero Viewpoint Touch Panels Step 3: Choose a Master Connection Mode Since the MVP-5150 may connect with a Master via USB or Ethernet, this requires a decision on the type of connection to be ma de between it and the Master .
Configuring Communication 34 MVP-5100/5150 Modero Viewpoint Touc h Panels Panel downloads and firmware updates The MVP-5100 and MVP-5150 devices support a USB dri ver for panel do wnloads and firmw are updates. This means that the devices connect to a host computer for updates through their Mini USB ports (FIG.
Configuring Communication 35 MVP-5100/5150 Modero Viewpoint Touch Panels 6. In the new windo w: - Select Use the following IP Address . Unde r IP addr ess , pro vide an IP address. Ensure that it is in the same subnet as the IP address giv en to the usb0 interface on the MVP-5100, but make sure that it has a different node number .
Configuring Communication 36 MVP-5100/5150 Modero Viewpoint Touc h Panels 9. The W ind ows XP machine no w searches for the suitable driver (FIG. 29). 10. Once the system finds the driv er , it displays its choice (FIG. 30). Click Finish to complete the driver installation.
Configuring Communication 37 MVP-5100/5150 Modero Viewpoint Touch Panels 3. Right click on the se lected device and select Properties to open the Local Ar ea Connection Pr operties window (FIG. 31). 4. In the Local Area Connection Properties window (FIG.
Configuring Communication 38 MVP-5100/5150 Modero Viewpoint Touc h Panels Systems Settings page of the Pr otected Settings menu, as shown in FIG. 33. (For more information, refer to the Pr otected Setup P ages section on page 55.) Under Subnet mask , set the subnet mask to 255.
Configuring Communication 39 MVP-5100/5150 Modero Viewpoint Touch Panels 2. In NetLinx Studio, select Settings > Master Communication Settings from the Main menu to open the Master Communication Settings dia log (FIG. 34). 3. Click the Communications Settings b utton to open the Communications Settings dialog (FIG.
Configuring Communication 40 MVP-5100/5150 Modero Viewpoint Touc h Panels 6. Click the Edit Settings button to open the V irtual NetLinx Master Settings dialog (FIG. 36). 7. Select the IP Address for the AMX USB device in the A vailable Conn ections section.
Configuring Communication 41 MVP-5100/5150 Modero Viewpoint Touch Panels 3. Set the Master Port and select Done . 4. If you enabled password security on your Master , se t the username and password within the device. 5. Select the blank field Username to open the k eyboard.
Configuring Communication 42 MVP-5100/5150 Modero Viewpoint Touc h Panels 8. Click OK to close the open dialogs, save the settings, and return to the main NetLinx Studio application. 9. Place the panel in the T able Charging Station or in the W all Charging Station.
Configuring Communication 43 MVP-5100/5150 Modero Viewpoint Touch Panels 18. Press the on-screen Reboot button to save an y changes and restart the panel. The panel will now be connected to the master . 19. Click the OnLine T ree tab in the W orkspace window to vie w the devices on the V irtual System.
Configuring Communication 44 MVP-5100/5150 Modero Viewpoint Touc h Panels.
Setup Pages 45 MVP-5100/5150 Modero Viewpoint Touch Panels Setup Pages Both the MVP-5100 an d MVP-5150 feature on-board Setup pages. Use the options in the Setup page s to access panel information and make v arious configuration changes. T o access the Setup pages, press the reset button and hold for 3 to 5 seconds (FIG.
Setup Pages 46 MVP-5100/5150 Modero Viewpoint Touc h Panels Setup Page (Cont.) Connection Status: Displays whether the panel has external communication, as well as the encryption status of the Master , the connection type ( Ethernet or USB ), and to which System the panel is connected.
Setup Pages 47 MVP-5100/5150 Modero Viewpoint Touch Panels Navigation Buttons The follo wing Navigation b uttons (FIG . 42) appear on the left side of the Setup page: Protected Setup Pages Information on the Protected Setup pages is available on page 55.
Setup Pages 48 MVP-5100/5150 Modero Viewpoint Touc h Panels Information Button The Information b utton allows access of both the Pr oject Information page, which contains data on the TPDesign4 file being used with the MVP-5100, and the P anel Information page, which contains detailed information on the panel its elf.
Setup Pages 49 MVP-5100/5150 Modero Viewpoint Touch Panels Project Information Page (Cont.) Sales Order: Displays the sales order information. Purchase Order: Displays the purchase order information. AMX IR 38K Assigned Port: Displays the AMX 38 kHz IR channel port used by the IR Emitter on the panel.
Setup Pages 50 MVP-5100/5150 Modero Viewpoint Touc h Panels Panel Information Page The Panel Information page provides detailed panel information (FIG. 44). Features on this page include: FIG. 44 Panel Information page Panel Information Page Back: Saves all changes and returns to the previous page.
Setup Pages 51 MVP-5100/5150 Modero Viewpoint Touch Panels Time & Date Settings Page The options on the T ime & Date Settings page (FIG. 45) allows setting and adjusting of time and date information on the NetLinx Master .
Setup Pages 52 MVP-5100/5150 Modero Viewpoint Touc h Panels Audio Settings Page The Audio Settings page allows adjustment of v olume lev els and panel sounds settings (FIG. 46). Features on these pages include: FIG. 46 Audio Settings pages Audio Settings Page Back: Saves all changes and returns to the previous page.
Setup Pages 53 MVP-5100/5150 Modero Viewpoint Touch Panels Battery Settings Page The options on the Battery Settings page allow setting of po w er warning preferences and battery sta tus information, and adjustment of the display times for battery warnings (FIG.
Setup Pages 54 MVP-5100/5150 Modero Viewpoint Touc h Panels.
Protected Setup Pages 55 MVP-5100/5150 Modero Viewpoint Touch Panels Protected Setup Pages The Pr otected Setup page (FIG. 48) provides secured access to advanced panel conf iguration options, including communication and security settings.
Protected Setup Pages 56 MVP-5100/5150 Modero Viewpoint Touc h Panels Protected Setup Page (Cont.) System Recovery: • Reset System Settings - Delet es all of the current configuration parameters on the panel (including IP Addresses, Device Number assignments, Passwords, and other presets).
Protected Setup Pages 57 MVP-5100/5150 Modero Viewpoint Touch Panels The Pr otected Setup page for the MVP-5100 is slightly different, as some of the functions are d isabled (FIG. 50). The particular functions that are disabled are explained in detail in the Pr otected Setup Navigation Buttons section on page 58.
Protected Setup Pages 58 MVP-5100/5150 Modero Viewpoint Touc h Panels Protected Setup Navigation Buttons The Protected Setup Navigation Buttons (FIG. 51) appear on the left edge of the Protected Setup pa ge. The Navigation Buttons for the MVP-5100 ha ve dif ferent functionality than those for the MVP-5150, as shown belo w .
Protected Setup Pages 59 MVP-5100/5150 Modero Viewpoint Touch Panels System Settings Page The System Settings page (FIG. 53) displays sets the NetLinx Master’ s communication settings. The elements of this page include: FIG. 53 System Settings page System Settings Page Elements Back: Saves all changes and returns to the previous page.
Protected Setup Pages 60 MVP-5100/5150 Modero Viewpoint Touc h Panels Refer to the Step 3: Choose a Master Connection Mode se ction on page 33 for m ore detailed information on using the System Settings page. System Setting Page Elements (Cont.) Mode Cycles between the connection modes : URL, Listen, NDP(UDP ,) URL(UDP), and Auto.
Protected Setup Pages 61 MVP-5100/5150 Modero Viewpoint Touch Panels Wireless Settings Page (MVP- 5150 Only) Use the options on the W ireless Settings page (FIG. 54) to configure communication settings for the wireless CF card (802.11b/g), an d read the device number assigned to the panel.
Protected Setup Pages 62 MVP-5100/5150 Modero Viewpoint Touc h Panels Wireless Settings Page (Cont.) IP Settings (Cont.) Secondary DNS Enter the secondary DNS address for this panel. Domain Enter a unique name to the panel for DNS look-up. MAC Address This unique address identifies the wireless Ethernet card in the panel (read- only).
Protected Setup Pages 63 MVP-5100/5150 Modero Viewpoint Touch Panels Wireless Settings Page (Cont.) Wireless Security (Cont.): EAP-TTLS This button opens the EAP-TTLS Settings page (FIG .
Protected Setup Pages 64 MVP-5100/5150 Modero Viewpoint Touc h Panels Wireless Security The options on the W ireless Security section (FIG. 55) include the wireless security methods supported by the NXA-WC80211GCF W i-Fi card.
Protected Setup Pages 65 MVP-5100/5150 Modero Viewpoint Touch Panels Open (Clear Text) Se ttings Press the Open (Clear T ext) b utton to open the Open (Clear T ext) Settings page (FIG. 56). Open security does not utilize any encryption methodology , but requires an SSID (alpha-numeric) entry .
Protected Setup Pages 66 MVP-5100/5150 Modero Viewpoint Touc h Panels Static WEP Settings Press the Static WEP b utton to open the Static WEP Setting s page (FIG. 57). Static WEP security requires that both a target W AP be identified and an encryption method be implemented prior to establishing communica tion.
Protected Setup Pages 67 MVP-5100/5150 Modero Viewpoint Touch Panels Refer to the Configuring W ir eless Network Access (MVP-5150 Only) section on page 23 and the Using the Site Surve y tool section on page 26 for further details on these security options.
Protected Setup Pages 68 MVP-5100/5150 Modero Viewpoint Touc h Panels Enter a pass phrase with a minimum of 8 characters and a maximum of 63. The exact same pass phrase (including capitaliza tion) must be entered in the access point.
Protected Setup Pages 69 MVP-5100/5150 Modero Viewpoint Touch Panels All three of these certif icate-using security me thods are documented in the following sections.
Protected Setup Pages 70 MVP-5100/5150 Modero Viewpoint Touc h Panels EAP-LEAP Setting s Press the EAP-LE AP button to open the EAP-LEAP Settings page (FIG. 60). EAP (Extensible Authentication Protocol) is an Enterprise authentication protocol that can be used in both wired and wireless network en vironments.
Protected Setup Pages 71 MVP-5100/5150 Modero Viewpoint Touch Panels Refer to the EAP Authentication section on page 160 for further details on these secu rity options. Refer to FIG. 61 for an example of how a typical EAP-LEAP system con figuration page should appear .
Protected Setup Pages 72 MVP-5100/5150 Modero Viewpoint Touc h Panels EAP-FAST Settin gs Press the EAP-F AST b utton to open the EAP-F AST Settings dialog (FIG. 62). EAP-F AST (Flexible Authentication via Secure T unneling) security was designed for wireless en vironments where security and ease of setup are e qually desirable.
Protected Setup Pages 73 MVP-5100/5150 Modero Viewpoint Touch Panels Refer to the EAP Authentication section on page 160 and the Using the Site Survey tool section on page 26 for further details on these security options.
Protected Setup Pages 74 MVP-5100/5150 Modero Viewpoint Touc h Panels EAP-PEAP Settings Press the EAP-PE AP b utton to open the EAP-PEAP Settings page (FIG. 63). PEAP (Protected Extensible Au thentication Protocol) was dev eloped as a way to securely transmit authentication information, such as passwords, ov e r a wireless network en vironment.
Protected Setup Pages 75 MVP-5100/5150 Modero Viewpoint Touch Panels EAP-PEAP security is designed for wireless en vironmen ts where it is necessary to transmit data securely ov er a wireless network.
Protected Setup Pages 76 MVP-5100/5150 Modero Viewpoint Touc h Panels EAP-TTLS Setting s Press the EAP-TT LS b utton to open the EAP-TTLS Settings page (FIG. 64). TTLS (EAP T unnele d T ransport Layer Security) is an auth entication method that does n ot use a client certificate to authenticate the panel.
Protected Setup Pages 77 MVP-5100/5150 Modero Viewpoint Touch Panels Refer to the EAP Authentication section on page 160 and the Using the Site Survey tool section on page 26 for further details on these security options. EAP-TTLS Settings (Cont.) Identity: Opens an on-screen keyboard.
Protected Setup Pages 78 MVP-5100/5150 Modero Viewpoint Touc h Panels EAP-TLS Settings Press the EAP-TL S button to open the EAP-TLS Settings page (FIG. 65). TLS (T ransport Layer Security) was the original st andard wireless LAN EAP au thentication protocol.
Protected Setup Pages 79 MVP-5100/5150 Modero Viewpoint Touch Panels Refer to the EAP Authentication section on page 160 for further details on these secu rity options. Refer to the Using the Site Survey tool section on page 26 for more information on using this feature.
Protected Setup Pages 80 MVP-5100/5150 Modero Viewpoint Touc h Panels Client certificate configuration A client certificate can be conf igu red by an IT depa rtment in se ve ral ways. The client certif icate and priv ate key can both be incorporated into one f ile or split into two separate files.
Protected Setup Pages 81 MVP-5100/5150 Modero Viewpoint Touch Panels Calibration Page The Calibration page (FIG. 66) allows you to calibrate the touch panel for accurate button selection. 1. Press and hold the reset b utton for 6 seconds to access the Calibration page (see FIG.
Protected Setup Pages 82 MVP-5100/5150 Modero Viewpoint Touc h Panels Other Settings Press the Other Settings b utton to display the two settings options for Cache and Passwo rd . Press one of the options within three seconds, or the two options buttons will slide back behind the Other Settings button.
Protected Setup Pages 83 MVP-5100/5150 Modero Viewpoint Touch Panels Password Settings Pag e The options on the P assword Settings page (FIG. 68) allow assignment of passwords required for users to access the Protected Setup page, and to release the device from a MVP-WCS-52 Charging Station.
Protected Setup Pages 84 MVP-5100/5150 Modero Viewpoint Touc h Panels The User Access section allo ws the Administrator to control access of all individuals using or attempting to use the MVP-5100. From this section, new users may be gi ven access rights to the de vice; howe ver , they will NO T be given access to the Pr otec ted Settings page.
Upgrading Firmware 85 MVP-5100/5150 Modero Viewpoint Touch Panels Upgrading Firmware The MVP-5100 and MVP-5150 com e already loaded with on-board firmware, which is upgradeable through the use of the latest version of NetLinx Studio. Refer to the NetLinx St udio version 2.
Upgrading Firmware 86 MVP-5100/5150 Modero Viewpoint Touc h Panels 6. Press the Reboot b utton both to sa ve an y changes and to restart the panel. Remember that the panel’ s connection type must be set to USB prior to r ebooting the panel and prior to inserting the USB connector .
Upgrading Firmware 87 MVP-5100/5150 Modero Viewpoint Touch Panels 10. Click the Communications Settings... b utton to open the Communications Settings dialog box (FIG. 70 ). 11. Click on the NetLinx Master ra dio button from the Platform Selection section.
Upgrading Firmware 88 MVP-5100/5150 Modero Viewpoint Touc h Panels 21. The OnLine T ree should now display the connection to the device. The Connection Status Icon on the device make take up to f ive seconds to re gister the connection.
Upgrading Firmware 89 MVP-5100/5150 Modero Viewpoint Touch Panels 7. Select T ools > Firmware T ransfers > Send to NetLinx Device from the main menu to open the Send to NetLinx Device dialog ( B in FIG.
Upgrading Firmware 90 MVP-5100/5150 Modero Viewpoint Touc h Panels A Special Note for Network Interface Connections Due to any USB connection to your PC being ma de through a Network Interface Connection (NIC), W indo ws will automatically make an y new NIC connec tion the Primary connection.
Upgrading Firmware 91 MVP-5100/5150 Modero Viewpoint Touch Panels 3. From the Advanced menu, select Advanced Settings... to open the Advanced Settings window (FIG. 75 ). 4. Under the Adapters And Bindings tab, the user needs to make sure the Local Area Connection is not at the top of the Connec tions list.
Upgrading Firmware 92 MVP-5100/5150 Modero Viewpoint Touc h Panels 6. When f inished, click OK to close the Advanced Settings windo w and sav e all changes.
Upgrading Firmware 93 MVP-5100/5150 Modero Viewpoint Touch Panels Uploading IR Codes to the MVP-5100 Since the MVP-5100 communicates with other devices through IR instead of through W iFi, making sure that the device has the latest IR codes is vital.
Upgrading Firmware 94 MVP-5100/5150 Modero Viewpoint Touc h Panels 4. When the IR file appears in the W orkspace Tree, right-click on the file and select De vice Mapping... to open the Device Mapping wi ndo w (FIG. 79). 5. Click the Map button to open the Enter DPS windo w (FIG.
Upgrading Firmware 95 MVP-5100/5150 Modero Viewpoint Touch Panels 7. From the main menu, select T ools > Firmware T ransfers > Send T o NetLinx Device... to open the Send to NetLinx Device window (FIG. 81). 8. Select the f ile to be transferred and cl ick Close when finished.
Upgrading Firmware 96 MVP-5100/5150 Modero Viewpoint Touc h Panels Adding an AMX IR Database fi le to Net Linx Studio T o add a n IR file contained in AMX’ s IR Database: 1. In the NetLinx Studio W orkspa ce, select Add F rom AMX IR Database ... to open the Select IR F r om A Database windo w .
Upgrading Firmware 97 MVP-5100/5150 Modero Viewpoint Touch Panels 4. In the File Properties windo w (FIG. 85), verify the Identif ier and Descrip tion information (in the only two f ields with editable data) and click OK. 5. The selected IR file no w appears in the NetLinx Studio W orkspace (FIG.
Upgrading Firmware 98 MVP-5100/5150 Modero Viewpoint Touc h Panels Adding a personal IR Databa se file to NetLinx Stud io T o choose a n IR file from a personal IR file database: 1. In the NetLinx Studio W orkspace, se lect Add F r om User IR Database.
Programming 99 MVP-5100/5150 Modero Viewpoint Touch Panels Programming Overview Y ou can program the MVP-5100 and MVP-5150, using the commands in this section, to perform a wide variety of operations using Send_Commands and variable te xt commands.
Programming 100 MVP-5100/5150 Modero Viewpoint Touc h Panels Page Commands (Cont. ) @PDR Set the popup location reset flag. If the flag is set, the popup will return to its default location on show instead of it s last drag location.
Programming 101 MVP-5100/5150 Modero Viewpoint Touch Panels Page Commands (Cont.) @PPF Deactivate a specific popup page on either a specified page or the current page. If the page name is empty , the current page is used (see example 2). If the popup page is part of a group, the whole group is deactivat ed.
Programming 102 MVP-5100/5150 Modero Viewpoint Touc h Panels Page Commands (Cont. ) @PPM Set the modality of a specific popup page to Modal or NonModal. A Modal popup page, when active, only allows you to use the buttons and features on that popup page.
Programming 103 MVP-5100/5150 Modero Viewpoint Touch Panels Page Commands (Cont.) @PSE Set the show effect for the specified popup page to the named show effect. Syntax: "'@PSE-<popup page name>;<show effect name>'" Va r i a b l e : popup page name = 1 - 50 ASCII characters.
Programming 104 MVP-5100/5150 Modero Viewpoint Touc h Panels Page Commands (Cont. ) PPOF Deactivate a specific popup page on either a specified page or the current page. If the page name is empty , the curr ent page is used (see example 2). If the popup page is part of a group, the whole group is deactivat ed.
Programming 105 MVP-5100/5150 Modero Viewpoint Touch Panels Programming Numbers The follo wing information provides the program ming numbers for colors, fonts, and borders.
Programming 106 MVP-5100/5150 Modero Viewpoint Touc h Panels RGB Values for all 88 Basic Colors (Cont.) Index No . Name Red Green Blue 36 V ery Light Cyan 0 255 255 37 Light Cyan 0 223 223 38 Cyan 0 1.
Programming 107 MVP-5100/5150 Modero Viewpoint Touch Panels Font styles and ID numbers Font styles can be used to program the text font s on buttons, sliders, and pages. The follo wing chart shows the def ault font type and their respectiv e ID numbers generated by TPDesign4.
Programming 108 MVP-5100/5150 Modero Viewpoint Touc h Panels Border styles and Programmi ng numbers Border styles can be used to program bor ders on bu ttons, sliders, and popup pages. The TPDesign4 T ouch Panel Design program has pr e-set border styles that are user-selectable.
Programming 109 MVP-5100/5150 Modero Viewpoint Touch Panels TPD4 Border Styles by Name (Cont.) No. Border styles No. Bor der styles 53 Diamond 185 97 Menu Bottom Rounde d 185 54 Diamond 195 98 Menu Bo.
Programming 110 MVP-5100/5150 Modero Viewpoint Touc h Panels TPD4 Border Styles by Name (Cont.) No. Border styles No. B order styles 141 Menu Left Rounded 55 149 Menu Left Rounded 135 142 Menu Left Ro.
Programming 111 MVP-5100/5150 Modero Viewpoint Touch Panels "^" Button Commands These Button Commands are used in NetLinx Studio and are case insensiti ve. All commands that begin with " ^ " hav e the capability of assigning a variable text address range and button state range.
Programming 112 MVP-5100/5150 Modero Viewpoint Touc h Panels "^" Button Commands (Cont .) ^B A U Append unicode text. Same format as ^UNI. Syntax: "'^BAU-<vt addr range>,<button states range>,<unicode text>'" Va r i a b l e : variable text address range = 1 - 4000.
Programming 113 MVP-5100/5150 Modero Viewpoint Touch Panels "^" Button Commands (Cont.) ^BCT Set the text color to the specified color . Only if the specified text color is not the same as the curren t color . Note : Color can be assigned by color name (without spaces), number or R,G ,B valu e (RRGGBB or RRGGBBAA).
Programming 114 MVP-5100/5150 Modero Viewpoint Touc h Panels "^" Button Commands (Cont .) ^BIM Set the input mask for the specified address. Syntax: "'^BIM-<vt addr range>,<input mask>'" Va r i a b l e : variable text address range = 1 - 4000.
Programming 115 MVP-5100/5150 Modero Viewpoint Touch Panels "^" Button Commands (Cont.) ^BMC Button copy command. Copy attributes of the source button to all the destination buttons. Note that the source is a single button state. Each state must be copied as a separate command.
Programming 116 MVP-5100/5150 Modero Viewpoint Touc h Panels "^" Button Commands (Cont .) ^BMF Set any/all button parameters by sending embedded codes and data. Syntax: "'^BMF-<vt addr range>,<button states range>,<data>'" Va r i a b l e s : variable text address char array = 1 - 4000.
Programming 117 MVP-5100/5150 Modero Viewpoint Touch Panels "^" Button Commands (Cont.) ^BMF (Cont.) For some of these commands and values, refer to the RGB V alues for all 88 Basic Colors table on page 105. ’%CF<on fill color >’ = Set Fill Color.
Programming 118 MVP-5100/5150 Modero Viewpoint Touc h Panels "^" Button Commands (Cont .) ^BMI Set the button mask image. Mask image is used to crop a borderless button to a non-square shap e.
Programming 119 MVP-5100/5150 Modero Viewpoint Touch Panels "^" Button Commands (Cont.) ^BNN Set the T akeNote network name for the specified Addresses. Syntax: "'^BNN-<vt addr range>,<network name>'" Va r i a b l e : variable text address range = 1 - 4000.
Programming 120 MVP-5100/5150 Modero Viewpoint Touc h Panels "^" Button Commands (Cont .) ^BOR Set a border to a specific border style associated with a border value for those buttons with a defined address range. Refer to the Border Styles and Programming Numbers table on page 108 for more information.
Programming 121 MVP-5100/5150 Modero Viewpoint Touch Panels "^" Button Commands (Cont.) ^BRD Set the border of a button state/ states. Only if the specified border is not the same as the current border . The border names are available through the TPDesign4 border -name drop-down list.
Programming 122 MVP-5100/5150 Modero Viewpoint Touc h Panels "^" Button Commands (Cont .) ^BVL Log-On/Log-Off the computer control connection. Syntax: "'^BVL-<vt addr range>,<connection>'" Va r i a b l e : variable text address range = 1 - 4000.
Programming 123 MVP-5100/5150 Modero Viewpoint Touch Panels "^" Button Commands (Cont.) ^CPF Clear all page flip s from a button. Syntax: "'^CPF-<vt addr range>'" Va r i a b l e : variable text address range = 1 - 4000.
Programming 124 MVP-5100/5150 Modero Viewpoint Touc h Panels "^" Button Commands (Cont .) ^FON Set a font to a specific Font ID value for those buttons with a defined address range. Font ID numbers are generated by th e TPDesign4 programmers report.
Programming 125 MVP-5100/5150 Modero Viewpoint Touch Panels "^" Button Commands (Cont.) ^GLH Change the bargraph upper limit. Syntax: "'^GLH-<vt addr range>,<bargraph hi>'" Va r i a b l e : variable text address range = 1 - 4000.
Programming 126 MVP-5100/5150 Modero Viewpoint Touc h Panels "^" Button Commands (Cont .) ^GSN Change the bargraph slider name or joystick cursor name. Slider names and cursor names can be f ound in the TP Design4 slider name and cursor drop-down list.
Programming 127 MVP-5100/5150 Modero Viewpoint Touch Panels "^" Button Commands (Cont.) ^JSB Set bitmap/ picture alignment using a numeric keypad layout for those buttons with a defined address range. The alignment of 0 is followed by ',<left>,<top> '.
Programming 128 MVP-5100/5150 Modero Viewpoint Touc h Panels "^" Button Commands (Cont .) ^JST Set text alignment using a numeric keypad layout for those buttons with a defined address range. The alignment of 0 is followed by ',<left>,<top> '.
Programming 129 MVP-5100/5150 Modero Viewpoint Touch Panels "^" Button Commands (Cont.) ^TEC Set the text effect color for the specified addresses/states to the specified color . The T ext Effect is specified by name and c an be found in TPD4.
Programming 130 MVP-5100/5150 Modero Viewpoint Touc h Panels Miscellaneous MVP Stri ngs back to the Master The following tw o strings are sent by the MVP panel back to the communicating Master: MVP Panel Loc k Passcode c ommands These commands are used to maintain a passcode list.
Programming 131 MVP-5100/5150 Modero Viewpoint Touch Panels Text Effects Names The following is a listing of text ef fects names associated with the ^TEF command on page 129. MVP Panel Lock Passcode Commands (Cont.) ^LPR Remove a given user from the User Access Passwords li st on the Password Setup page.
Programming 132 MVP-5100/5150 Modero Viewpoint Touc h Panels Button Query Commands Button Query commands reply back with a custom ev ent. There will be one custom e vent for each button/state combination. Each query is assigned a unique custom e vent type.
Programming 133 MVP-5100/5150 Modero Viewpoint Touch Panels All custom ev ents hav e the follo wing 7 fields: These fields are populated dif f erently for each query command.
Programming 134 MVP-5100/5150 Modero Viewpoint Touc h Panels Button Query Commands (Cont.) ?BCF Get the current fill color . Syntax: "'?BCF-<vt addr range>,<button states range>'" Va r i a b l e : variable text address range = 1 - 4000.
Programming 135 MVP-5100/5150 Modero Viewpoint Touch Panels Button Query Commands (Cont.) ?BMP Get the current bitmap name. Syntax: "'?BMP-<vt addr range>,<button states range>'" Va r i a b l e : variable text address range = 1 - 4000.
Programming 136 MVP-5100/5150 Modero Viewpoint Touc h Panels Button Query Commands (Cont.) ?BRD Get the current border name. Syntax: "'?BRD-<vt addr range>,<button states range>'" Va r i a b l e : variable text address range = 1 - 4000.
Programming 137 MVP-5100/5150 Modero Viewpoint Touch Panels Button Query Commands (Cont.) ?FON Get the current font index. Syntax: "'?FON-<vt addr range>,<button states range>'" Va r i a b l e : variable text address range = 1 - 4000.
Programming 138 MVP-5100/5150 Modero Viewpoint Touc h Panels Button Query Commands (Cont.) ?JSB Get the current bitmap justification. Syntax: "'?JSB-<vt addr range>,<button states range>'" Va r i a b l e : variable text address range = 1 - 4000.
Programming 139 MVP-5100/5150 Modero Viewpoint Touch Panels Button Query Commands (Cont.) ?JST Get the current text justification. Syntax: "'?JST-<vt addr range>,<button states range>'" Va r i a b l e : variable text address range = 1 - 4000.
Programming 140 MVP-5100/5150 Modero Viewpoint Touc h Panels Button Query Commands (Cont.) ?TEF Get the current text effect name. Syntax: "'?TEF-<vt addr range>,<button states range>'" Va r i a b l e : variable text address range = 1 - 4000.
Programming 141 MVP-5100/5150 Modero Viewpoint Touch Panels Panel Runtime Operations Serial Commands are used in the AxcessX T erminal Emulator mode. These commands are case insensitiv e. Panel Runtime Op eration Commands ABEEP Output a single beep even if beep is Off.
Programming 142 MVP-5100/5150 Modero Viewpoint Touc h Panels Panel Runtime Operatio n Commands (Cont.) @AKP Pop up the keypad icon and initialize the text string to that specified. Keypad string is set to null on power up and is stored until power is lost.
Programming 143 MVP-5100/5150 Modero Viewpoint Touch Panels Panel Runtime Operatio n Commands (Cont.) @EKP Extend the Keypad. Pops up the keypad icon and initializes the text string to that specified.
Programming 144 MVP-5100/5150 Modero Viewpoint Touc h Panels Panel Runtime Operatio n Commands (Cont.) @SOU Play a sound file. Syntax: "'@SOU-<sound name>'" Va r i a b l e s : sound name = Name of the sound file. Supported sound file formats are: WAV & MP3.
Programming 145 MVP-5100/5150 Modero Viewpoint Touch Panels Input Commands These Send Commands are case insensitive. Input Command s ^CAL Put panel in calibration mode. Syntax: "'^CAL'" Example: SEND COMMAND Panel,"'^CAL'" Puts the panel in calibration mode.
Programming 146 MVP-5100/5150 Modero Viewpoint Touc h Panels Embedded codes The following is a list of G4 compatible embedd ed codes: Embedded Codes Decimal numbers Hexidecimal values Vir tual keystro.
Programming 147 MVP-5100/5150 Modero Viewpoint Touch Panels Panel Setup Commands These commands are case insen sitiv e. Panel Setup Commands ^MUT Set the panel mute state. Syntax: "'^MUT-<mute state>'" Va r i a b l e : mute state= 0 = Mute Off and 1 = Mute On.
Programming 148 MVP-5100/5150 Modero Viewpoint Touc h Panels.
Battery Life and Replacem ent 149 MVP-5100/5150 Modero Viewpoint Touch Panels Battery Life and Replacement Overview The battery po wering the MVP-5100 and MVP-5150 is designed for upwards of 300 deep dischar ge rechargings.
Battery Life and Replacement 150 MVP-5100/5150 Modero Viewpoint Touc h Panels Battery Replacement The touch panel's battery is intended to last the life of the device, b ut it may be upgraded for ad ditional run time.
Appendix A: Text Formatti ng 151 MVP-5100/5150 Modero Viewpoint Touch Panels Appendix A: Text Formatting Text Formatting Codes for Bargraphs/Joysticks T ext formatting codes for bargraphs provide a me.
Appendix A: Text Formatting 152 MVP-5100/5150 Modero Viewpoint Touc h Panels Text Area Input Masking T ext Area Input Masking may be used to limit the allo wed/correct characters that are entered into a text area.
Appendix A: Text Formatti ng 153 MVP-5100/5150 Modero Viewpoint Touch Panels Refer to the following Send_Commands for more detailed information: Input mask ranges These ranges allow a user to specify the min imum and maximum numeric value for a field.
Appendix A: Text Formatting 154 MVP-5100/5150 Modero Viewpoint Touc h Panels A keyboard entry using normal text entry is straightforward. Ho we ver , once an input mask is applied, the behavior of the k eyboard needs to change to accommodate the input mask's requirement.
Appendix A: Text Formatti ng 155 MVP-5100/5150 Modero Viewpoint Touch Panels URL Resources A URL can be broken into se veral parts. F or example, with the URL http://www .
Appendix B: Wireless Technology 156 MVP-5100/5150 Modero Viewpoint Touc h Panels Appendix B: Wireless Technology Overview of Wireless Technology 802.11b/2.4 GHz and 802.11a/5 GHz are the two major WLAN standards and both operate using radio frequency (RF) technology .
Appendix B: Wireless Technology 157 MVP-5100/5150 Modero Viewpoint Touch Panels Terminology 802.1x IEEE 802.1x is an IEEE standard that is built on the Internet standard EAP (Extensible Authentication Protocol ). 802.1x is a standard for passing EAP messages ov er either a wired or wirele ss LAN.
Appendix B: Wireless Technology 158 MVP-5100/5150 Modero Viewpoint Touc h Panels WEP Short for W ired Equi valent Pri vacy , WEP is a scheme used to secure wireless networks (W i-Fi). A wi reless network broa dcasts messages using radio which are particularly susceptible to hacker a ttacks.
Appendix B: Wireless Technology 159 MVP-5100/5150 Modero Viewpoint Touch Panels WP A 2 Also kno w as IEEE 802.11 i, this is an amendment to the 802.11 standard specifyi ng security mechanisms for wireless networ ks. The 802.11i scheme makes use of the Advanced Encryption Standard (AES) block cipher; WEP and WP A use the RC4 stream cipher .
Appendix B: Wireless Technology 160 MVP-5100/5150 Modero Viewpoint Touc h Panels EAP Authentication EAP (Extensible Authentication Protocol) is an Enterprise authentication protocol that can be used in both a wired and wireless network environment. EAP requires the use of an 802.
Appendix B: Wireless Technology 161 MVP-5100/5150 Modero Viewpoint Touch Panels EAP communication overview EAP Authentication goes a step beyond just encrypting data transfers, b ut also requires that a set of credentials be validated before the client (panel) is allo wed to connect to the rest of the network (FIG.
Appendix B: Wireless Technology 162 MVP-5100/5150 Modero Viewpoint Touc h Panels AMX Certificate Upload Utility The Certificate Upload utility gi ves you the ability to compile a list of target touch panels, select a pre- obtained certificate (uniquely identifying the panel), and then upload that f ile to the selected panel.
Appendix B: Wireless Technology 163 MVP-5100/5150 Modero Viewpoint Touch Panels 6. S elect the IP Address that corresponds to the vi rtual IP Address assigned to the USB connection port on the computer .
Appendix C: Troubleshooting 164 MVP-5100/5150 Modero Viewpoint Touc h Panels Appendix C: Troubleshooting This section describes the solutions to possible ha rdware/f irmware issues that could arise during the common operation of a Modero touch panel.
Appendix C: Troubleshooting 165 MVP-5100/5150 Modero Viewpoint Touch Panels Device Isn’t Appearin g In The Online Tre e Tab 1. V erify that the System number is the same on both the NetLinx Project Na vigator window and the System Settings page on the de vice.
Appendix C: Troubleshooting 166 MVP-5100/5150 Modero Viewpoint Touc h Panels Only One Modero Panel I n My System Shows Up Symptom: I have mor e than one Moder o panel connected to my System Master and only one shows up. Multiple NetLinx Compatible devices, such as MVP panels, can be associated for use with a single Master .
Appendix 167 M VP-5100/5150 Modero Viewpoint To uch Panels.
12/08 © 2008 AM X. All rights reserved. AMX and the AM X logo are register ed trademarks of AMX. AMX reserv es the right to alter specifica tions without notice a t any time. It’s Your World - Take Con trol™ 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 USA • 800.
Ein wichtiger Punkt beim Kauf des Geräts AMX Modero MVP-5150 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie AMX Modero MVP-5150 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für AMX Modero MVP-5150 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von AMX Modero MVP-5150 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über AMX Modero MVP-5150 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon AMX Modero MVP-5150 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von AMX Modero MVP-5150 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit AMX Modero MVP-5150. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei AMX Modero MVP-5150 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.