Benutzeranleitung / Produktwartung 28645EG des Produzenten Intex
Zur Seite of 24
195 PO (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Model SF80110 Model SF70110 Model SF60110 Don’t forget to try these other fine Intex products: pools, pool accessories, inflatable pools and in-home toys, airbeds and boats available at fine retailers or visit our website.
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 2 Warnings .......................................................................... 3 Parts References ............................
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 3 IMPORTANT SAFETY RULES Read, Understand and Follow All Instructions Carefully Before Installing and Using this Product.
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 4 PARTS REFERENCE Before assembling your product, please take a few minutes to check the contents and become familiar with all the parts.
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 5 REF. NO. DESCRIPTION QTY. SPARE PART NO.
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 6 The strainer grid prevents large objects from jamming and/or damaging the filter pump. If your pool has an inflatable top ring, install the strainer, nozzle and plunger valve before inflating the pool liner top ring.
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 7 POOL INLET - NOZZLE & PLUNGER VALVE SETUP (optional) 1. In a counter-clockwise motion unscrew plunger valve union from the threaded strainer connector (26) (see drawing 5).
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 8 PRODUCT SPECIFICATIONS SETUP INSTRUCTIONS NOTE: NOT SUITABLE FOR USE WITH KCP-LOW -SALT AUTOMATIC SALTWATER SYSTEM (MODEL 6110/6220) The sand filter removes suspended particles but does not sanitize your pool.
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 9 4. In a clockwise motion screw filter housing nut (17) onto the motor water inlet (See drawings 12.1 & 12.2) . 5. Replace the basket (16) and leaf trap cover (14) back to the pre-filter housing (See drawings 13.
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 10 SETUP INSTRUCTIONS (continued) Sand loading: IMPORTANT: Use No. 20 silica sand or glass sand with particle size range 0.45 to 0.85 mm (0.
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 11 6-way valve installation: 1. Lower the 6-way valve over the tank slowly, and ensure the bypass pipe protruding underneath the 6-way valve fits securely into the center pipe hub (7) top opening (see drawing 19) .
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 12 SAND FILTER PUMP HOSE CONNECTION SETUP The 6-way valve has three hose connection ports. 1. Connect one hose (12) end to the pre-filter inlet and the other end of the hose to the lower plunger valve with the strainer.
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 13 SAND FILTER PUMP HOSE CONNECTION SETUP (continued) For INTEX pool size 16' and below: 1. In a counter-clockwise motion unscrew plunger valve union from the threaded strainer connector (26) .
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 14 OPERATING INSTRUCTIONS Valve Position Function Water Flow Direction FILTER (see.
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 15 Initial startup and operation: Before operating, be sure that: • All the hoses have been connected and tightened securely, and correct amount of filter sand have been loaded.
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 16 OPERATING INSTRUCTIONS (continued) 5.
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 17 INTEX POOLS OPERATING TIME TABLE (WITHOUT INTEX SALTWATER SYSTEM) Pool Size Wat.
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 18 NON-INTEX POOLS OPERATING TIME TABLE Water Capacity Sand filter pump operating .
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 19 MOTOR PRE-FILTER CLEANING AND MAINTENANCE 1. Make sure the filter pump is switched off, then disconnect the power cord from the electrical outlet.
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 20 1. Before emptying your pool for long term storage, or relocation, be sure the water is directed towards an acceptable drain water receptacle away from the house.
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 21 TROUBLESHOOTING GUIDE TROUBLE CAUSE SOLUTION • Line cord must be plugged into a 3 wire outlet that is protected by a Class A Ground Fault Circuit Interrupter, or RCD.
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 22 COMMON POOL PROBLEMS PROBLEM DESCRIPTION CAUSE SOLUTION ALGAE COLORED WATER FLOATING MATTER IN WATER CHRONIC LOW WATER LEVEL SEDIMENT ON POOL BOTTOM SURFACE DEBRIS • Chlorine and pH levels need adjustment.
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 23 GENERAL AQUATIC SAFETY Water recreation is both fun and therapeutic.
195 PO SAVE THESE INSTRUCTIONS (195PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English Page 24 PARTS LIST LIMITED WARRANTY Your Sand Filter Pump has been manufactured using the highest quality materials and workmanship. All Intex products have been inspected and found free of defects prior to leaving the factory.
Ein wichtiger Punkt beim Kauf des Geräts Intex 28645EG (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Intex 28645EG noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Intex 28645EG - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Intex 28645EG reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Intex 28645EG erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Intex 28645EG besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Intex 28645EG verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Intex 28645EG. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Intex 28645EG gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.