PRODUCT DA T A ® U.S. Registered Trademark Copyright © 1997 Honeywell Inc. • All Rights Reserved D896 Automatic V ent Damper GENERAL D896 Automatic V ent Dampers are used with atmospheric type, gas-fired equipment to reduce home heating losses b y closing off the vent betw een heat cycles.
D896 A UT OMA TIC VENT D AMPER 68-0186 2 ORDERING INFORMA TION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distr ibutor , ref er to the TRADELINE® Catalog or price sheets for complete ordering number .
D896 A UT OMA TIC VENT D AMPER 68-0186 3 NO TE: A minimum of a 30 V A transf or mer must be used when D896 is installed with S86/S8600/S8610/ S8620. Electrical Connections: F our-wire plug receptacle. Thermostat Anticipator Setting: 0.13A. Operating Times: Appro ximate Damper Opening Time: 30 seconds.
D896 A UT OMA TIC VENT D AMPER 68-0186 4 IMPORT ANT 1. The atmospheric draft hood outlet area must be smaller or equal to the inlet area of the damper assembly . 2. If a second gas valv e needs to be installed, refer to the gas valv e manufacturer instructions f or the procedure.
D896 A UT OMA TIC VENT D AMPER 68-0186 5 Fig. 3. Installing D896 V ent Damper . IMPORT ANT Ne ver mount the vent damper with the motor actuator abov e or below the vent. Do not install the damper blade plug if the v ent damper is installed on a system with a continuous or standing pilot.
D896 A UT OMA TIC VENT D AMPER 68-0186 6 Fig. 5. D896 with co ver off. Honeywell D892/D896 Wires Honeywell D80B Wires Johnson Q35 Wires EFFIKAL RVG Wires Yellow Orange Green 1 Orange Blue and Red Whit.
D896 A UT OMA TIC VENT D AMPER 68-0186 7 MV MV/PV PV GND (BURNER) 24V GND 24V SPARK S8600F, H, M; S8610F,H POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. REMOVE PLUG ONLY IF USING VENT DAMPER. FUSE BLOWS ON STARTUP WHEN PLUG IS REMOVED; THEN MODULE OPERATES ONLY WHEN VENT DAMPER IS CONNECTED.
D896 A UT OMA TIC VENT D AMPER 68-0186 8 Fig. 10. Snap-Tite™ Bo x Connector release. Checkout Heating 1. Tu rn on the po wer supply . 2. If using a thermostat, set the heat anticipator at 0.13A. 3. Set the thermostat or controller to 10 ° F (6 ° C) above the room temperature to call f or heat.
D896 A UT OMA TIC VENT D AMPER 68-0186 9 Thermostat Setting Symptom Possible Cause Action Set thermostat 10°F above room temperature to call for heat. No response from D896. Incorrect wiring or blown fuse. • Check the circuit breaker or fuse and, if necessary, reset or replace.
D896 A UT OMA TIC VENT D AMPER 68-0186 10 ANSI ST ANDARDS EXHIBIT A Procedure For Saf ety Inspection of an Existing Appliance Installation The f ollowing procedure is intended as a guide to aid in determining that an appliance is proper ly installed and is in a safe condition f or continuing use.
D896 A UT OMA TIC VENT D AMPER 68-0186 11 EXHIBIT B Procedure f or Installing Electrically Operated Automatic Vent Damper De vices on Existing Appliances This procedure is intended as a guide to aid in safely installing an electrically operated or mechanically actuated automatic vent damper de vice on an existing appliance .
D896 A UT OMA TIC VENT D AMPER 68-0186 12 Honeywell Europe S.A. 3 Avenue du Bourget B-1140 Brussels Belgium Honeywell Asia Pacific Inc. Room 3213-3225 Sun Hung Kai Centre No.
Ein wichtiger Punkt beim Kauf des Geräts Honeywell D896 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Honeywell D896 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Honeywell D896 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Honeywell D896 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Honeywell D896 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Honeywell D896 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Honeywell D896 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Honeywell D896. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Honeywell D896 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.