Heat & Glo • ST -42TVFL-IPI • 455-902 Rev . C • 12/07 Model: ST -42TVFL-IPI 1 Owner ’ s Manual Installation and Operation • Do not store or use gasoline or other flamma- ble vapors and liquids in the vicinity of this or any other appliance.
2 Heat & Glo • ST -42TVFL-IPI • 455-902 Rev . C • 12/07 ! SAFETY AND W ARNING INFORMA TION READ and UNDERST AND all instructions carefully before starting the inst allation. FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty .
3 Heat & Glo • ST -42TVFL-IPI • 455-902 Rev . C • 12/07 T able of Contents Safety and W arning Information .................. 2 Service Parts List ......................................... 4 Section 1: Approvals and Codes ................ 6 Appliance Certification .
4 Heat & Glo • ST -42TVFL-IPI • 455-902 Rev . C • 12/07 4 Log Set Assembly Service Parts Diagram Service Parts ST -42TVFL-IPI Beginning Manufacturing Date: July 2002 Ending Manufacturing Dat.
V alve Assembly Diagram/Parts List Service Parts Beginning Manufacturing Date: July 2002 Ending Manufacturing Date: ______ ST -42TVFL-IPI 5 Heat & Glo • ST -42TVFL-IPI • 455-902 Rev .
Approval Listings and Codes Appliance Certification The Heat & Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories. CERTIFICA TION MODEL LABORA TO RY TYPE S T ANDARD ST -42TVFL-IPI Underwriters B- V ent ANSI Z21.
7 Heat & Glo • ST -42TVFL-IPI • 455-902 Rev . C • 12/07 2 Getting S t arted Introducing the Heat & Glo Gas Fireplaces Heat & Glo B-type vent gas fireplaces are designed to operate with all exhaust gases expelled to the outside of the building.
8 Heat & Glo • ST -42TVFL-IPI • 455-902 Rev . C • 12/07 Figure 1. Diagram of the ST -42TVFL-IPI When planning a fireplace installation, it’s necessary to determine: • Where the unit is to be installed. • The vent system configuration to be used.
Figure 3. Fireplace Locations and Space Requirements Clearance Requirements The top, back, and sides of the fireplace are defined by stand-offs. Minimum Clearances from the Fireplace to Combustible Ma.
Minimum Clearances from the B-T ype V ent Pipe to Combustible Materials is 1 inch (25 mm) all around the pipe. Step 2 Framing the Fireplace Fireplace framing can be built before or after the fireplace is set in place. Framing should be positioned to accommodate wall coverings and fireplace facing material.
11 Heat & Glo • ST -42TVFL-IPI • 455-902 Rev . C • 12/07 Step 3 Negative Pressure Make-up Air Negative Pressure warning : When negative pressure is present, an atmospherically vented fireplace (with a draft hood) may not function properly and it may down draft.
Detailed inst allation instructions for Model AK-TV Outside Air kit are found in the kit. Air Damper Before lighting the burner , open the damper plate by sliding the air damper rod, located by the gas valve, towards you. Figure 5. Make-up Air DUCT COLLAR DAMP ER AS SEM BL Y Heat & Glo • ST -42TVFL-IPI • 455-902 Rev .
13 Heat & Glo • ST -42TVFL-IPI • 455-902 Rev . C • 12/07 Step 4 Inst alling the V ent System A. V ent System Approvals These fireplaces are approved to use 6-inch (152mm) diameter B-type vent. B-type vent must be used when the vent system is within combustible construction.
Figure 6. V ent System Att achment ! WARNING: THIS GAS FIREPLACE MUST NEVER BE VENTED BY CONNECTING TO A CHIMNEY FLUE SERVING A SEP ARA TE SOLID FUEL BURNING APPLIANCE. 4 FT . MINIMUM 17 FT . MAXIMUM MAXIMUM HORI ZON T AL RUN 4 FT MINIMUM 10 FT . MINIMUM Heat & Glo • ST -42TVFL-IPI • 455-902 Rev .
15 Heat & Glo • ST -42TVFL-IPI • 455-902 Rev . C • 12/07 C. Bedroom Installation in Canada This model MUST NOT be vented into a vent system installed exterior to a building. The part of the vent system above the roof line can be exterior to the building.
The diagram below shows how to properly position, level, and secure the fireplace. 1. Place the fireplace into position. 2. Level the fireplace from side to side and from front to back. 3. Shim the fireplace with non-combustible material, such as sheet metal, as necessary .
17 Heat & Glo • ST -42TVFL-IPI • 455-902 Rev . C • 12/07 Step 7 The Gas Supply Line N O T E : Have the gas supply line installed i n accordance with local building codes b y a qualified installer approved and/or licensed as required by the locality .
• At the gas line access hole, use insulation to re- pack the space around the gas pipe. • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing. The gas line should be installed by a qualified service technician.
19 Heat & Glo • ST -42TVFL-IPI • 455-902 Rev . C • 12/07 ! ! Step 9 Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensed electrician. Caution: Disconnect remote controls if you are absent for extended time periods. This will prevent accidental fireplace operation.
Heat & Glo • ST -42TVFL-IPI • 455-902 Rev . C • 12/07 Figure 10. Intermittent Pilot Ignition (IPI) Wiring Diagram For Intermittent Pilot Ignition (IPI) Wiring Appliance Requirements This appliance requires that 1 10-120 V AC be wired to the junction box.
Heat & Glo • ST -42TVFL-IPI • 455-902 Rev . C • 12/07 If the box is being wired to a wall mounted sw i tch for use with a fan (See Figure 1 1): • The power supply for the appliance must be brought into a switch box. • The power can then be supplied from the switch box to the appliance using a minimum of 14-3 with ground wire.
22 Heat & Glo • ST -42TVFL-IPI • 455-902 Rev . C • 12/07 ! Step 10 Finishing The following diagram shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace.
S tep 1 1 Inst alling T rim, Logs, and Ember Material Figure 13. Sealant Material Hearth Extensions A hearth extension may be desirable for aesthetic reasons. However , ANSI or CAN/CGA testing standards do not require hearth extensions for gas fireplace appliances.
Figure 14. Placement of the Ember Material Placing the Ember Material Ember material is shipped with this gas fireplace. The bag labeled Golden Ember (GE-93) is flame colorant material. The bag labeled Glowing Ember (050-721) is standard glowing ember material.
Step 12 Before Lighting the Fireplace Before lighting the fireplace, be sure to do the following: Remove all paperwork and documents from underneath the fireplace. Review safety warnings and cautions • Read the Safety and W arning Information sec- tion at the beginning of this Installers Guide .
4 Maint aining and Servicing Y our Fireplace T ype of Fireplace Maintenance T ask T o Maintenance Frequency B y Be Completed Replacing Once annually , Qualified Brush away loose ember material near Old Ember during the Service the burner .
Heat & Glo, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .heatnglo.com Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer , please visit www .
Ein wichtiger Punkt beim Kauf des Geräts Heat & Glo LifeStyle ST-42TVFL-IPI (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Heat & Glo LifeStyle ST-42TVFL-IPI noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Heat & Glo LifeStyle ST-42TVFL-IPI - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Heat & Glo LifeStyle ST-42TVFL-IPI reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Heat & Glo LifeStyle ST-42TVFL-IPI erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Heat & Glo LifeStyle ST-42TVFL-IPI besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Heat & Glo LifeStyle ST-42TVFL-IPI verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Heat & Glo LifeStyle ST-42TVFL-IPI. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Heat & Glo LifeStyle ST-42TVFL-IPI gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.