Benutzeranleitung / Produktwartung 6100PLUS des Produzenten Heat & Glo LifeStyle
Zur Seite of 40
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 1 Owner ’ s Manual Installation and Operation Models: 6100PLUS Fresh Air Fireplace Installation and service of this appliance should be performed by qualified personnel.
2 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 Read this manual before installing or operating this appliance. Please retain this owner ’ s manual for future reference. Congratulations on selecting a Heat & Glo gas appliance—an elegant and clean alternative to wood burning appliances.
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 3 T able of Contents 1 Listing and Code Approvals 4 A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. BTU Specifi cations . . . . . . . . . . .
4 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 1 Listing and Code Appro v als A. Appliance Certifi cation Do NOT use this appliance if any part has been under water .
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 5 A. Design and Installation Considerations Heat & Glo vented gas appliances are designed to operate with all exhaust gases expelled to the outside of the build- ing. Check building codes prior to installation.
6 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 Note: • Illustrations refl ect typical installations and are FOR DESIGN PURPOSES ONL Y . • Illustrations/diagrams are not drawn to scale. • Actual installation may vary due to individual design preference.
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 7 B. Construct the Appliance Chase A chase is a vertical boxlike structure built to enclose the gas appliance and/or its vent system. V ertical vents that run on the outside of a building may be, but are not required to be, installed inside a chase.
8 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 C. Clearances 1 in. (25 mm) min. to perpendicular wall A 3-1/2 in. (89 mm) min. from fireplace opening to perpendicular wall B 48 in. (1219 mm) max. Mantel Leg or Perpendicular W all T op of Appliance Drywall A B Figure 3.
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 9 A. V ent T ermination Minimum Clearances Fire Risk Explosion Risk • Do not pack air space with insulation or other materials. Maintain vent clearance to combustibles as specifi ed.
10 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 5 5 V ent Informat ion and Diagrams Note: Refer to the HRV20 0PLUS installation manual for additional installat ion and ven ting instr uctions. Fire Risk Fumes Risk This unit MUST be vented with the HRV200PLUS.
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 1 1 6 Appliance P reparation Do NOT notch into the framing around the appliance spacers.
12 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 A. Fuel Conversion Before making gas connections ensure appliance being in- stalled is compatible with the available gas type.
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 13 • A small amount of air will be in the gas supply lines. When fi rst lighting appliance it will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally .
14 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 A. Recommendation for Wire • Requires 1 10 V AC to be wired to the junction box for proper operation of the appliance. Batter y po lar i t y mu st be c o r rec t or m o dul e d ama ge wi ll occur .
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 15 C. System Wiring Note: The 6100 PL US must be elect ricall y wired and grounded in ac cordanc e with loc al codes or , in the absenc e of local codes, with National E lec tr ic Cod e ANS I /N FP A 70 - lat est ed iti on or the Cana dian Elec tri c Cod e, CSA C22.
16 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 HRV200PLUS Control W iring The 6100PLUS is designed to operate as a system with the HRV200PLUS. Six low-voltage wires are required to electrically connect the two appliances.
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 17 Figure 8.3 Appliance Circuit Board Wiring.
18 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 D. W all Switch This appliance comes with a triple-gang wall switch which controls the following functions: • Flame - On/Off T urns the appliance burner operation on and off.
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 19 Figure 8.6 Junction Box WHT WHT BLK BLK GRN wire inside box Copper ground attached to GRN screw with GRN wire 14/2WG Cover Plate outside firebox Romex Connector Figure 8.5 Junction Box Detail F .
20 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 A. Mantel Projections Figure 9.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance.
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 21 A. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. Shock Risk Fire Risk Use ONL Y optional accessories approved for this appliance.
22 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 Placing the Rock Wool • Place a small amount of 1/2 in. diameter pieces (dime-size) of rock wool on the burner pan so the rock wool touches but does not cover the holes in the burner pan.
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 23 D. Grate and Log Assembly Place the Grate • Place the grate around the burner . Push back the grate until the left middle piece of the grate comes in contact with the burner assembly .
24 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 Fire Risk Burn Risk HOT! DO NOT TOUCH. SEVERE BURNS MA Y RESUL T . CLOTHING IGNITION MA Y RESUL T Glass and other surfaces are hot during operation and cool down. W ARNING • Keep children away .
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 25 Note: The H RV200 PL US can use indoor air instead of t he gas appliance for defrost if t he op tional defrost kit (par t # HRV 99DEFKI T) is in sta ll ed . HRV200PLUS Defrost Mode • The HRV200PLUS demands gas appliance operation for defrost.
26 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 B. Lighting the Appliance.
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 27 C. After the Appliance is Lit Initial Break-in Procedure When you light the appliance, you may notice that it pro- duces heat which does have an associated odor or smell.
28 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 With proper installation, operation and maintenance your gas appliance will provide years of trouble-free service.
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 29 Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualifi ed service technician should perform an appliance check-up at the beginning of each heating season.
30 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 This page intentionally left blank..
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 31 A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only . For framing dimensions and clearances refer to Sec- tion 3. Figure 14.1 Appliance Dimensions 1 4 14 Ref erenc e M ater ia ls 38 in.
32 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 B. Service Parts List Exploded Parts Diagram Service Parts 6100PLUS Beginning Manufacturing Date: 02/04 Ending Manufacturin.
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 33 Service Parts List Service Parts 6100PLUS Beginning Manufacturing Date: 02/04 Ending Manufacturing Date: Active 1 Grate 370-361A 370-361A 1 2 Burner Assembly 4041-006 4041-006 1 3 V alve Assembly - Natural Gas 4041-003 4041-01 1 1 4 Light Film 4041-101 4041-101 2 5 36-in.
34 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 Exploded Parts Diagram Service Parts 6100PLUS Beginning Manufacturing Date: 02/04 Ending Manufacturing Date: Active.
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 35 Service Parts List Service Parts 6100PLUS Beginning Manufacturing Date: 02/04 Ending Manufacturing Date: Active # Description of Part 6100PLUS 6100PLUS-LP Qty .
36 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 C. Optional Components Exploded Parts Diagram Optional Components Service Parts 6100PLUS Beginning Manufacturing Date: 02/0.
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 37 Optional Components Service Parts 6100PLUS Beginning Manufacturing Date: 02/04 Ending Manufacturing Date: Active # Optional Components 6100PLUS 6100PLUS-LP Qty .
38 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 This page intentionally left blank..
Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 39 D. Limited Lifetime W arranty 6100PLUS Gas Appliance Limited W arranty Hearth & Home T echnologies Inc. (“HHT”) extends the following warranty for Heat-N-Glo® 6100PLUS (“Appliance”) products installed in homes in the United States of America and Canada.
40 Hearth & Home T echnologies • 6100PLUS • 4041-127 Rev D • 09/05 E. Contact Information Hearth & Home T echnologies Inc. 800 W . Jef ferson Lake City , MN 55041 Please contact your Heat & Glo dealer with any questions or concerns. For the number of your nearest Heat & Glo dealer , place call 1-888-427-3973.
Ein wichtiger Punkt beim Kauf des Geräts Heat & Glo LifeStyle 6100PLUS (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Heat & Glo LifeStyle 6100PLUS noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Heat & Glo LifeStyle 6100PLUS - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Heat & Glo LifeStyle 6100PLUS reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Heat & Glo LifeStyle 6100PLUS erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Heat & Glo LifeStyle 6100PLUS besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Heat & Glo LifeStyle 6100PLUS verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Heat & Glo LifeStyle 6100PLUS. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Heat & Glo LifeStyle 6100PLUS gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.