1 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 Models: 550TRSI-AUF 550TRSILP-AUF Owner ’ s Manual Installation and Operation SAI Global Ref No GSCS20163 AS4553:2008 • DO NOT USE OR STORE FLAMMABLE MA TERIALS NEAR THIS APPLIANCE.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 2 M O D E L S: 5 50 T RS I -A UF , 55 0T RS IL P- AU F ARE SAI GLOBAL APPROVED FOR NA TU RAL GAS, PRO P ANE OR BUT ANE AS A BALANCED FLUE HEA TER. Refer to the appliance data plates for gas consumptions and pressures.
3 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: _____.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 4 FOR YOUR SAFETY This appliance is designed to operate on LPG IF YOU SMELL GAS: • T urn off as supply at bottle • Exti.
5 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 6 = Contains updated information. L. Install V ertical T ermination Cap . . . . . . . . . . . . . . . . . . . . 51 1 1 Gas Information A. Gas Pressure Requirements . . . .
7 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 C. Limited Lifetime W arranty AUSTRALIAN W ARRANTY INFORMA TION W arranty information in the attached manual is for international markets, not Australia. For Australian warranty information, please see below .
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 8 W arranty Period Heat & Glo Manufactured Appliances and V enting Components Covered Parts Labor Gas Wood Pellet EP A .
9 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 • Non Heat & Glo venting components, hearth components or other accessories used in conjunction with the appliance. • Any part of a pre-existing replace system in which an insert or a decorative gas appliance is installed.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 10 A. Appliance Certication 1 Listing and C ode Approv al s MODELS: 550TRSI-AUF , 550TRSILP-AUF LABORA TORY : SAI Global TYPE: Gas Space Heating Appliance ST ANDARD: AS4553-2008 C.
1 1 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate replace before read - ingand understandingoperating instructions.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 12 D. Clear Space W ARNING! DO NOT place combustible objects in front of the replace or block louvers. High temperatures may start a re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth.
13 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 I. Lighting Instructions (IPI) 1. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand. 2. Wait ve (5) minu tes to cle ar out any gas.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 14 Not e: If t he module is in LOCK- OUT mode, reset ting the cir cuit br eaker to the app lianc e will al so reset t he mod ule.
15 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 K. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the replace off and allow it to completely cool.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 16 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle xed glass assembly with care.
17 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 B. Maintenance T asks-Qualied Service T echnician The following tasks must be performed by a qualied ser- vice technician.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 18 A. T ypical Appliance System NOTICE: Illustrations and photos reect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale.
19 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to op - erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside of the building.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 20 5 F raming and C learances A. Selecting Appliance Location Whe n sel ect ing a loca tio n for th e app lia nce it is imp ort an t to con sid er the r equ ire d c lea ra nce s t o w all s (se e F igu re 5.
21 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 22 * MINIMUM FRAMING DIMENSIONS Models A B C D E F G H I J DVP Pipe SLP Pipe Rough Opening (Height) **DVP Pipe SLP Pipe Rou.
23 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 D. Mantel and W all Projections W AR NI NG! R isk o f F ir e! Co mp ly w it h al l m in imu m cle ar - an ces a s spe ci ed.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 24 A. V ent T ermination Minimum Clearances Figure 6.1 Minimum Height From Roo f T o Lowest Discharge Opening 6 T er mination Locations Fire Risk. Maintain vent clearance to combustibles as specied.
25 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 Figure 6.3 Minimum Clearances for T ermination NOTES: 1. All distances are measured vertically or horizontally along the wall to a point in line with the nearest part of the terminal.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 26 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP and SLP venting systems. Refer to Section 16.B for vent component information.
27 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 Example: DVP pipe 3 ft. (1 m) min. vertical = 1 1 ft. (3.35 m) max. horizontal SLP pipe 7 ft. (2.13 m) min. vertical = 1 1 ft. (3.35 m) max. horizontal Figure 7.4 T op V ent - Horizontal T ermination Fire Risk.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 28 T op V ent - Horizontal T ermination - (continued) Figure 7.5 T wo Elbows INST ALLED HORIZONT ALL Y H 1 H 2 V 1 V 1 Minimum H 1 + H 2 Maximum Elbow only Not allowed 6 in. 152 mm 1 ft.
29 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 Figure 7.6 Three Elbows H 2 H 1 V 2 V 1 Note: A 6 in. (152 mm) section of straight ue must be atta ched to the heate r before a 90° elbow . USE SLP SERIES COMPONENTS ONL Y V 1 Min.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 30 T op V ent - V ertical T ermination This model is approved to use DVP-Series ue pipe com - ponents. A DVP-TVHW vertical Termination Cap must be used to terminate ue systems in a vertical position.
31 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 MODEL 550TRSI-AUF 550TRSILP-AUF FLUE TERMINA TION APPROV ALS DVP-TRAP2 HORIZONT AL TERMINA TION CAP DVP-FBHT HORIZONT AL.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 32 Figure 7.10 H 1 V 1 V 2 USE SLP SERIES COMPONENTS ONL Y T wo Elbows T op V ent - V ertical T ermination - (continued) V 1 H 1 Maximum V 2 V 1 + V 2 Min. Elbow only Not allowed * * * 6 in.
33 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 Figure 7.1 1 T op V ent - V ertical T ermination - (continued) Three Elbows IN ST ALL ED HO RI ZONTALL Y H 1 H 2 V 1 V 2 USE SLP SERIES COMPONENTS ONL Y V 1 H 1 + H 2 V 2 V 1 + V 2 Minimum H 1 + H 2 Maximum Elbow only 1 ft.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 34 Rear V ent - Horizontal T ermination Figure 7.13 No Elbow One 45º Elbow H 1 Do not use a 45º elbow in corner installations. Use two 90º elbows instead. Figure 7.12 USE DVP SERIES COMPONENTS ONL Y USE DVP SERIES COMPONENTS ONL Y H 1 Minimum H 1 Maximum 6-1/2 in.
35 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 Rear V ent - Horizontal T ermination - (continued) T wo Elbows Figure 7.14 Figure 7.15 Three Elbows H 1 H 2 V 1 INSTALLED HORIZONTALLY H 3 H 1 H 2 V 1 USE DVP SERIES COMPONENTS ONL Y USE DVP SERIES COMPONENTS ONL Y H 1 Maximum V 1 Minimum H 2 H 1 + H 2 Maximum 6 in.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 36 Rear V ent - V ertical T ermination One Elbow Figure 7.16 T wo Elbows Figure 7.17 V 1 H 1 IN ST AL LED HO RI ZO NT AL L Y H 1 H 2 V 1 USE DVP SERIES COMPONENTS ONL Y USE DVP SERIES COMPONENTS ONL Y V 1 Minimum H 1 Maximum 1 ft.
37 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 Rear V ent - V ertical T ermination - (continued) Three Elbows Figure 7.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 38 A. Pipe Clearances to Combustibles W ARNING!Risk ofFire! Maintain air space clearance to vent.
39 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 C. Install the Ceiling Firestop A ceiling restop MUST be used between oors and attics. • DVP pipe only - Frame an opening 10 in. x 1 0 i n. (2 54 mm b y 2 54 mm ) w he nev er th e vent penetrates a ceiling/oor (see Figure 8.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 40 Figure 8.5 Attic Insulation Shield Figure 8.6 Heat Zone ® Knockout E. In sta ll ing t he Opt ion al Hea t-Z on e ® - 24 0V Kit • Remove the knockout from the replace and discard it (see Figure 8.
41 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 42 B. Rear V ent NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. N OT ICE : Onc e the sea l cap has be en remo ved it CAN NO T be reattached.
43 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 Figure 9.16 Proper Positioning and Securing of an Appliance NAILING TABS (BOTH SIDES) PILOT HOLES Figure 9.14 Non-combustible Board C. Installing the Non-combustible Board The fac tor y suppl ied non -co mbu sti ble boa rd must be used.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 44 Natural Gas Propane Butane 550TRSI-AUF 1 1.13 mm N/A N/A 550TRSILP-AUF N/A Full Open Full Open Figure 9.17 Fixed Glass Assembly GLASS ASSEMBL Y LA TCHES (BOTH BOTTOM AND TOP) E.
45 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 1 0 Installing V ent Pipe ( D V P and SL P P ipe ) A. Assemble V ent Sections (DVP Pipe Only) Attach V ent to the Firebox Assembly Not e: T he end of the pi pe sec tio ns with the la nced tabs w ill fac e toward th e applia nce.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 46 B. Assemble V ent Sections (SLP Pipe Only) T o attach the rst vent component to the starting collars of the appliance: • Lock the vent components into place by sliding the pipe section onto the collar .
47 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 120º Figure 10.8 Securing V ertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections E. Di sa ss emb le V e nt S ect io ns • Rotate either section (see Figure 10.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 48 10 in. (254 mm) 12 in. (305 mm) INTERIOR WALL SHIELD Figure 10.13 Flue Pipe & Firestop Figure 10.14 Hole and New Framing Members For V ertical Runs - One restop is REQUIRED at the hole in each ceiling through which the ue passes.
49 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 Figure 10.15 Ceiling Firestop (Ceiling Side) Figure 10.16 Attic Firestop CEILING CEILING FIRESTOP RAFTER NAILS (4 REQUIR.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 50 J. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.19) to determine the length of pipe to extend through the roof. • Slide the roof ashing over the pipe sections extending through the roof as shown in Figure 10.
51 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 CAULK K. Assemble and Install Storm Collar CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 52 1 1 Gas Informat ion A. Gas Pressure Requirements W ARNING! Risk of Explosion! An in-line regulator MUST be installed if the gas pressure exceeds 3.7 kPa. Failure to install a regulator could damage valve.
53 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 Figure 1 1.1 The gas is introduced to the appliance on the left hand side. See Figure 1 1.1. After the gas pipe installation is complete, check carefully all ga s conn ect ions for lea ks wit h a comm erci all y-av aila ble , noncorrosive leak check solution.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 54 1 2 Elec tr ical Information A. Wiring Requirements NOTICE: This appliance must be installed by a qualied electrician in accordance with the relevant national and local regulations.
55 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 BLUE BROWN GREEN/ YELLOW Figure 12.2 D. Blower These heaters have a factory installed fan and electrical junction cord. These components are located behind the lower door .
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 56 Hearth & Home T echnologies disclaims any responsibility for , and the warranty will be voided by , the following actions: • Installation and use of any damaged system component.
57 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 5. Close the housing door . See Figure 12.7. 4. Pla ce rem ote co ntr ol in sid e h ous ing .
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 58 Figure 12.7 Mounting Remote Control Housing AUX300CE Module Installation • In ser t t he 4 h ol e h ar nes s f ro m t he AUX 30 0CE mod ul e i nt o the 4 pin pl ug on th e c ont rol mo du le.
59 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 FIREPLACE ST A TUS THERMOST A T THERMOST A T DESIRED TEMP SETTING FLAME HEIGHT F AN SPEED ADJUST ABLE AUXILIARY ADJUST A.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 60 About ON Mode • All functions can be accessed when the remote control is in the ON mode. • Only active functions will be displayed when the remote control is in the ON mode.
61 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 Adjusting Thermostat • Press the MENU button to activate the menu. • Using the UP and DOWN arrows highlight the THERMO icon and press SELECT . • Use the UP and DOWN arrows to turn the THERMO ON or OFF , then press SELECT (the SET TEMP will start blinking).
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 62 Frequently Asked Questions/T roubleshooting Symptom Possible Cause Corrective Action Remote control will not transmit Batteries V erify batteries are functional and installed correctly .
63 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 1 3 Finis hing A. Mantel and W all Projections W AR NI NG! R isk o f Fir e! C om ply w ith a ll m in imu m cl ea r - an ces as sp ec ie d.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 64 A. Remove Fixed Glass Assembly See Section 9.E. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the rebox.
65 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 E. Log Placement Instructions Log Assembly: LOGS-550TRSAUD CAUTION: Logs are fragile! Carefully remove the logs from the packaging.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 66 LOG #4 (SR V278-705): Position log #4 between log #1 and the locating tab on the fourth grate tine.
67 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 LOG #7 (SRV484-703): Place log #7 on the groove in log #2 with its rear top on log #1 and front top resting on log #5. LOG #8 (SRV347-701): Hook log #8 on the right hand corner grate tine and rest its rear on log #1 as shown.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 68 1 5 T roublesho oting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
69 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 T roubleshooting (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot ame has been lit, ame rectication has not occurred.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 70 1 6 Reference Materials A. Appliance Dimension Diagram Di men si on s a re a ct ua l a pp li anc e di men si on s. Us e for r ef ere nc e onl y . F or fr am in g d im en sio ns a nd cl ea ran ce s ref er t o S ec ti on 5.
71 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 B. Maintenance T asks Inspect Maintenance T asks Doors 1. Inspect for scratches, dents or other damage and repair as necessary . 2. V erify no obstructions to airow . 3.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 72 C. V ent Components Diagrams Figure 16.3 DVP vent components Pipe Effective Length Inches Millimeters DVP4 4 102 DVP6 6 .
73 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 C. V ent Components Diagrams ( continued ) Figure 16.4 DVP vent components DVP-TRAP2 DVP-TRAP2 Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 74 DVP-TRAPFL Flashing DVP-HRC-SS DVP-HRC-ZC-SS Horizontal T ermination Cap Fire Risk. • When using DVP-HRC-SS and DVP-HRC-ZC- SS termination caps on top vented fireplaces, a 6 inch (152 mm) minimum vert ical vent section is require d before installing first elbo w .
75 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 B. V ent Components Diagrams (continued) Figure 16.6 SLP Series V ent Components 8-3/4 in. 222 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 6 in. 152 mm 6-1/2 in. 165 mm 6-5/8 in.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 76 B. V ent Components Diagrams (continued) Figure 16.7 SLP Series V ent Components SLP-SNKD Snorkel T ermination Cap SLP-T.
77 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 D. Service Parts Beginning M anufacturing Date: July 2010 Ending M anufacturing Date: ______ 550TRSI-AUF , 550TRSILP-AUF Log Set Assembly IMPORT ANT : THIS IS DA TED INFORMA TION.
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 78 Service Parts Beginning M anufacturing Date: July 2010 Ending M anufacturing Date: ______ 550TRSI-AUF , 550TRSILP-AUF #19 V alve Assembly IMPORT ANT : THIS IS DA TED INFORMA TION.
79 Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 Service Parts List 550TRSI-AUF , 550TRSILP-AUF IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • 550TRSI-AUF , 550TRSILP-AUF • 2079-980 Rev . N • 5/12 80 E. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer , please visit www .
Ein wichtiger Punkt beim Kauf des Geräts Heat & Glo LifeStyle 550TRSI-AUF (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Heat & Glo LifeStyle 550TRSI-AUF noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Heat & Glo LifeStyle 550TRSI-AUF - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Heat & Glo LifeStyle 550TRSI-AUF reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Heat & Glo LifeStyle 550TRSI-AUF erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Heat & Glo LifeStyle 550TRSI-AUF besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Heat & Glo LifeStyle 550TRSI-AUF verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Heat & Glo LifeStyle 550TRSI-AUF. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Heat & Glo LifeStyle 550TRSI-AUF gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.