Benutzeranleitung / Produktwartung TIARAI-CES des Produzenten Hearth and Home Technologies
Zur Seite of 60
August 1, 2008 TIARA I-B TIARA II-B DIRECT VENT ROOM HEA TER O-T O - T L T ested and Listed by Portland Oregon USA OMNI-T est Laboratories, Inc. C US TIARAI-BK-B TIARAI-BR-B TIARAI-CTO TIARAI-CES Mode.
Page 2 Heat & Glo · T iara I B & T iara II B · 7010-149M August 1, 2008 Rea d this man ual bef ore instal ling or op erating th is appl iance.
Page 3 Heat & Glo · T iara I B & T iara II B · 7010-149M - T ABLE OF CONTENTS - August 1, 2008 Section 1: Listing and Code Approvals A. Appliance Certi fi cations ...................... 4 B. Glass Speci fi cations .........................
Page 4 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M 1 Listing and Code Approvals The product is listed to ANSI standards for “V ented Gas Appliance Heaters” and appli.
August 1, 2008 Page 5 Heat & Glo · T iara I B & T iara II B · 7010-149M NOTE: The following requirements reference various Massachusetts and national codes not contained in this document.
Page 6 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M 2 Getting Started Check building codes prior to installation. • Installation MUST comply with local, regional, state and national codes and regulations.
August 1, 2008 Page 7 Heat & Glo · T iara I B & T iara II B · 7010-149M 3 Appliance Location and Clearances A. Selecting Appliance Location NOTE: · Illustrations re fl ect typical installations and are FOR DESIGN PURPOSES ONL Y . · Illustrations/diagrams are not drawn to scale.
Page 8 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M Figure 3.1 A G A A B F E A "A" measurement is from appliance top, not side G H D C C 90˚ off top up and out.
August 1, 2008 Page 9 Heat & Glo · T iara I B & T iara II B · 7010-149M 4 T ermination Locations A. V ent T ermination Minimum Clearances Gas T ermination Wood & Fuel Oil T ermination Comments A 6 in. 20 in. min. Horizontal distance between terminations B 20 in.
Page 10 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M Figure 4.4 CAUTION: IF EXTERIOR W ALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THA T A VINYL PROTECTOR KIT BE INST ALLED. V = VENT TERMINAL X = AIR SUPP L Y INLET = ARE A WHERE TERMINA L IS NOT PERMITTED A = 12 inche s .
August 1, 2008 Page 1 1 Heat & Glo · T iara I B & T iara II B · 7010-149M 5 V ent Information A. V enting Components B. Use of Elbows In order to comply with applicable codes and product war.
Page 12 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M D. How to Use the V ent Graph E. V enting Guidelines 1 . Measure the distance from the top of appliance to the center of the 90° elbow.
August 1, 2008 Page 13 Heat & Glo · T iara I B & T iara II B · 7010-149M Step 1. Determine the desired location of the appliance. Check to ensure that wall studs or roof rafters are not in the way when the venting system is being planned. If this is the case, you may want to adjust the location of the appliance.
Page 14 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M NOTE: (1) Installation requires a minimum of 6 in. (152mm) horizontal run of vent with a 1/4 in. (6mm) rise run towards the termination. Each 1 ft. (305mm) of horizontal venting must include a 1/4 in.
August 1, 2008 Page 15 Heat & Glo · T iara I B & T iara II B · 7010-149M Step 5. Place the wall thimble cover over the pipe assembly and slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into the vent termination cap assembly .
Page 16 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M Step 1. Check the installation instructions for required 1 in. (25mm) clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces.
August 1, 2008 Page 17 Heat & Glo · T iara I B & T iara II B · 7010-149M Step 4. Assemble the desired lengths of pipe and elbows necessary to reach from the appliance up through the round support box. Ensure that all pipe and elbow connections are in their fully twist-locked position.
Page 18 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M Ceiling Firestop Nails Minimum 1 in. (24mm) Clearance Minimum 1 in. (24mm) Clearance Minimum 1 in. (24mm) Clearance Minimum 1 in. (24mm) Clearance Figure 5.16 Fire Risk.
August 1, 2008 Page 19 Heat & Glo · T iara I B & T iara II B · 7010-149M 2. Cathedral Ceiling Level Cathedral Ceiling Support Box 2 in. (51mm) Min. below finished ceiling Cut hole 1/8 in. (3mm) greater in size than pattern of support box as it is projected onto roof line Figure 5.
Page 20 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M 3. Class A Metal Chimney Figure 5.20 TERMINA TION CAP EXISTING MET AL CHIMNEY SYSTEM TOP ADAPTOR FLASHING 4 in. (102mm) FLEX PIPE RETRO CONNECTOR DIRECT VENT PIPE T op Adapter Sheet Metal Screws Flex Pipe Figure 5.
August 1, 2008 Page 21 Heat & Glo · T iara I B & T iara II B · 7010-149M 4. Existing Masonry Chimney T ype C - Up & Out Installation T ype D - Hearth Mount Figure 5.24 T ype A & B Co-Axial to Co-Linear Chimney Liner T ermination Cap Co-Axial to Co-Linear Connector 3 in.
Page 22 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M 10 in. x 10 in. (254mm x 254mm) framed opening in wall Studwall Masonry Chimney Retro Connector (4) Masonry Bolts (Not Included) Wall Thimble Cover Cut and bend flashing as needed to fit Sealant adhesive Figure 5.
August 1, 2008 Page 23 Heat & Glo · T iara I B & T iara II B · 7010-149M High Wind T ermination Cap T op Adaptor (3) Sheet Metal Screws Flashing Step 9. Attach the flex to the retro connector. Use three sheet metal screws to attach the flex liner to the connector ( Figure 5.
Page 24 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M 6 Gas Information A. Fuel Conversions Before making gas connections ensure that the appliance being installed is compatible with the available gas type.
August 1, 2008 Page 25 Heat & Glo · T iara I B & T iara II B · 7010-149M MILLIVOT GENERA TOR THERMOCOUPLE PILOT HOOD Figure 6.4 Pull off pilot hood and set aside. NOTE: Do not remove retaining clip from hood. 5/32 in. Allen wrench Figure 6.5 Use a 5/32 in.
Page 26 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M B. Gas Pressures If the pressure is not suf fi cient, ensure: 1) the piping used is large enough. 2) the supply regulator is adequately adjusted. 3) that the total gas load for the residence does not exceed the amount supplied.
August 1, 2008 Page 27 Heat & Glo · T iara I B & T iara II B · 7010-149M NOTE: A listed (and Commonwealth of Massachusetts approved) 1/2 inch (13mm) T -handle manual shut-off valve and fl exible gas connector are connected to the 1/2 inch (13mm) control valve inlet.
Page 28 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M 7 Electrical Information A. Recommendation for Wire C. Standing Pilot Ignition System Wiring See B5 below for recommended maximum lead length (two wire) when using wall thermostat/switch.
August 1, 2008 Page 29 Heat & Glo · T iara I B & T iara II B · 7010-149M Figure 7.1 Shock hazard. • Replace damaged wire with type 105 O C rated wire.
Page 30 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M 8 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. B. T op to Rear V ent Conversion TOOLS REQUIRED: Power drill; #2 Phillips bit; high-temp sealant (optional).
August 1, 2008 Page 31 Heat & Glo · T iara I B & T iara II B · 7010-149M Figure 8.7 Insert inner collar adapter to rear fl ue vent. Figure 8.8 Install vent pipe adapter with gasket or high-temp sealant to rear vent opening. Attach with screws removed in Figure 8.
Page 32 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M D. Shutter Adjustment Figure 8.1 1 The shutter is located on the underside of the appliance, on the right side. To adjust the shutter, loosen the wingnut. Retighten the wingnut after adjustment.
August 1, 2008 Page 33 Heat & Glo · T iara I B & T iara II B · 7010-149M H. Positioning the Logs - Tiara I-B TA B S COMPLETED BRICK INST ALLATION Figure 8.19 Complete brick installation. While breakable, the logs do not become fragile until after the appliance is burned and they have cured.
Page 34 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M #1 Figure 8.23 Place rear log onto the two locating pins located on the rear log shelf in the back of the fi rebox. #1 #2 #3 Figure 8.24 Place left and right logs into recesses cut out for them on the left and right side of the burner .
August 1, 2008 Page 35 Heat & Glo · T iara I B & T iara II B · 7010-149M M. Optional Blower Figure 8.27 From the rear of the appliance, slide the blower into the blower housing with the magnetic strips down. The blower openings should be at the front.
Page 36 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M SPEED CONTROL LOCK NUT AND STEM Figure 8.31 Remove the knob and lock nut from the speed control. Install speed control onto access panel with stem sticking out the pre-punched hole.
August 1, 2008 Page 37 Heat & Glo · T iara I B & T iara II B · 7010-149M N. W arming Shelves Installation TOOLS REQUIRED: Phillips head screwdriver . KIT CONTENTS: (2) W arming shelves, (2) brackets, and (4) 1/4 in. (Phillip head screws. Figure 8.
Page 38 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M 9 Operating Instructions A. Before Lighting Appliance Read this entire manual prior to using the appliance. Failure to follow the instructions may result in property damage, bodily injury, or even death.
August 1, 2008 Page 39 Heat & Glo · T iara I B & T iara II B · 7010-149M C. Lighting Appliance 1. Set the thermostat to lowest setting. 2. T urn off all electric power to the appliance if service is to be performed. 3. Push in gas control knob slightly and turn clockwise to "OFF" position.
Page 40 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M D. After Appliance is Lit When you light your appliance, you may notice that it pro- duces heat which does have an associated odor or smell.
August 1, 2008 Page 41 Heat & Glo · T iara I B & T iara II B · 7010-149M 10 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Page 42 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M Symptom Possible Cause Corrective Action 3. (Continued) c. Defective valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter at the thermopile terminals.
August 1, 2008 Page 43 Heat & Glo · T iara I B & T iara II B · 7010-149M 11 Maintaining and Servicing Appliance Although the frequency of your appliance servicing and maintenance will depend on use and the type of installation, a quali fi ed service technician should perform an appliance check-up at the beginning of each heating season.
Page 44 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M A. Maintenance T asks Inspect Maintenance T asks Doors 1. Inspect for scratches, dents or other damage and repair as necessary . 2. V erify no obstructions to air fl ow .
August 1, 2008 Page 45 Heat & Glo · T iara I B & T iara II B · 7010-149M 12 Reference Materials A. Appliance Dimension Diagram - T iara I-B Dimensions are actual appliance dimensions. Use for reference only . For clearances to combustibles refer to Section 3.
Page 46 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M C L F G C A B Location Inches Millimeter Location Inches Millimeter A 41-3/4 1060 E 22-1/4 565 B 29-1/2 749 F 14-3/4 375 C 9-1/2 240 G 22-1/4 565 D 29-1/4 743 Figure 12.
August 1, 2008 Page 47 Heat & Glo · T iara I B & T iara II B · 7010-149M C. V ent Components Diagram Figure 12.3 SL-D Series V ent Components 4 in. (102 mm) inner pipe 6-5/8 in. (168 mm) outer pipe 9-1/4 in. (235mm) 6-1/2 in. (165mm) 6-5/8 in.
Page 48 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M D. V ent Components List Description HHT SL-P M= Multi Pack (6) Simpson Dura-V ent DirectV ent Pro Selkirk Direct-T e.
August 1, 2008 Page 49 Heat & Glo · T iara I B & T iara II B · 7010-149M 45° Elbow , Swivel, Black - 46DV A-E45B - - SV4EB45 90° Elbow , Galvanized SLP90M See Swivel 4DT -EL905 4D90LS - 90.
Page 50 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M E. Service Parts List TIARA I-B (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 8-03 Ending Manufacturi.
August 1, 2008 Page 51 Heat & Glo · T iara I B & T iara II B · 7010-149M IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealer's VIP site. When ordering, supply serial and model numbers to ensure correct service parts.
Page 52 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M Item # Part Description Alphabetical Order Part # IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealer's VIP site. When ordering, supply serial and model numbers to ensure correct service parts.
August 1, 2008 Page 53 Heat & Glo · T iara I B & T iara II B · 7010-149M IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealer's VIP site. When ordering, supply serial and model numbers to ensure correct service parts.
Page 54 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M G. Service Parts List (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 8-03 Ending Manufacturing Date: T.
August 1, 2008 Page 55 Heat & Glo · T iara I B & T iara II B · 7010-149M IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealer's VIP site. When ordering, supply serial and model numbers to ensure correct service parts.
Page 56 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealer's VIP site. When ordering, supply serial and model numbers to ensure correct service parts.
August 1, 2008 Page 57 Heat & Glo · T iara I B & T iara II B · 7010-149M IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealer's VIP site. When ordering, supply serial and model numbers to ensure correct service parts.
Page 58 August 1, 2008 Heat & Glo · T iara I B & T iara II B · 7010-149M I. W arranty Policy © 2007 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY HEA T & GLO GAS APPLIANCE PRODUCTS 060-981E 10/07 BASIC ONE-YEAR W ARRANTY .
August 1, 2008 Page 59 Heat & Glo · T iara I B & T iara II B · 7010-149M J. Homeowner ’ s Notes.
Page 60 Heat & Glo · T iara I B & T iara II B · 7010-149M August 1, 2008 Heat & Glo, a brand of Hearth & Home T echnologies, Inc. 20802 Kensington Boulevard Lakeville, MN 55044 CONT ACT INFORMA TION : Please contact your Heat & Glo dealer with any questions or concerns.
Ein wichtiger Punkt beim Kauf des Geräts Hearth and Home Technologies TIARAI-CES (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Hearth and Home Technologies TIARAI-CES noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Hearth and Home Technologies TIARAI-CES - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Hearth and Home Technologies TIARAI-CES reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Hearth and Home Technologies TIARAI-CES erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Hearth and Home Technologies TIARAI-CES besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Hearth and Home Technologies TIARAI-CES verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Hearth and Home Technologies TIARAI-CES. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Hearth and Home Technologies TIARAI-CES gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.