Benutzeranleitung / Produktwartung 68-1021-01 des Produzenten Extron electronic
Zur Seite of 36
Extron Electronics, USA 1230 South Lewis Street Anaheim, CA 92805 USA 714.491.1500 F ax 714.491.1517 Extron Electronics, Europe Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 F ax +31.33.453.4050 Extron Electronics, Asia 135 Joo Seng R oad, #04-01 PM Industrial Building Singapore 368363 +65.
Precautions This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock.
IPL M PDP-ES • Quick Start Guide QS-1 T o install and set up the IPL M PDP-ES interface card, follow these steps: Step 1 T urn all of the equipment off and disconnect it from the power source. Step 2 Remove the preinstalled Pioneer communication ES card fr om the Pioneer plasma.
IPL M PDP-ES • Quick Start Guide Quick Start Guide — IPL M PDP-ES, cont’d i IPL M PDP-ES • Table of Contents Chapter 1 • Introduction .......................................................... 1-1 About this Manual ..........................
ii IPL M PDP-ES • Table of Contents T able of Contents, cont’d IPL M PDP-ES 1 Chapter One Intr oduction About this Manual About the IPL M PDP-ES Interface Card Features 68-1021-01 Rev A 11 04 All trademarks mentioned in this manual are the properties of their r espective owners.
IPL M PDP-ES • Introduction Intr oduction IPL M PDP-ES • Introduction • Email Alerts — Email reminders can be sent to a specified mailbox automatically when certain conditions are tr ue. When a scheduled or monitored event occurs (such as the number of usage hours on the plasma) maintenance personnel can be notified via an email message.
IPL M PDP-ES • Introduction Introduction, cont’d IPL M PDP-ES 2 Chapter T wo Installation and Operation Installation Overview Installation of the IPL M PDP-ES Interface Card Panel Features and Cab.
IPL M PDP-ES • Installation and Operation IPL M PDP-ES • Installation and Operation Installation and Operation 2-3 T o remove the Pioneer communication ES card, do the following: 1 . Ensure that the Pioneer plasma is turned off and disconnected from the power sour ce.
IPL M PDP-ES • Installation and Operation IPL M PDP-ES • Installation and Operation Installation and Operation, cont’d 2-5 Panel Features and Cabling See figure 2-6 below for detailed information about connections, LEDs, and power .
IPL M PDP-ES • Installation and Operation IPL M PDP-ES • Installation and Operation Installation and Operation, cont’d 2-7 Resetting the unit There are five reset modes available by using the Reset button ( 5 ) on the front panel. The Reset button is r ecessed, so use of a pointed stylus, ballpoint pen, or Extron T weeker is suggested.
IPL M PDP-ES • Installation and Operation Installation and Operation, cont’d IPL M PDP-ES 3 Chapter Thr ee Connection and Configuration Connecting the Hardware Configuring the Hardware 2-8 • If events are curr ently running following the momentary (<1 second) press, the Power LED flashes thr ee times, indicating the stopping of events.
IPL M PDP-ES • Connection and Configuration IPL M PDP-ES • Connection and Configuration Connection and Configuration 3-3 3. Ensure that your PC is connected to the network switch, hub, or router . RS-232 port The IPL M PDP-ES can be connected to a controller device or a local PC through its RS-232 port.
IPL M PDP-ES • Connection and Configuration IPL M PDP-ES • Connection and Configuration Connection and Configuration, cont’d 3-5 Enter the desired new IP address and the MAC addr ess (located on the face panel) for the interface card. For example: arp –s 10.
IPL M PDP-ES • Connection and Configuration IPL M PDP-ES • Connection and Configuration Connection and Configuration, cont’d 3-7 IP addr ess: 192.168.254.253 Subnet mask: 255.255.0.0 8. Save the changes and exit the Network setup. Reboot the PC, if required, for the changes to become effective.
IPL M PDP-ES • Connection and Configuration Connection and Configuration, cont’d IPL M PDP-ES 4 Chapter Four Communication and Contro l Communication with the Interface Card Programmer’s Guide f.
IPL M PDP-ES • Communication and Control IPL M PDP-ES • Communication and Control Communication and Contr ol Communication with the Interface Card The on-board W eb server has a set of built in, default W eb pages, which can be accessed via a W eb browser .
IPL M PDP-ES • Communication and Control Communication and Contr ol IPL M PDP-ES • Communication and Control Gateway IP address The Gateway IP Address field identifies the address of the gateway to the mail server to be used if the interface card and the mail server are not on the same subnet.
IPL M PDP-ES • Communication and Control IPL M PDP-ES • Communication and Control Communication and Control, cont’d Figure 4-4 — Web server Passwords screen After you press the Submit button, the passwor d window should appear (figure 4-5). Figure 4-5 — Web server password window 5.
IPL M PDP-ES • Communication and Control IPL M PDP-ES • Communication and Control Communication and Control, cont’d notification indicating the number of operation hours remaining). The scheduled notification is sent to the appr opriate mailbox.
IPL M PDP-ES • Communication and Control IPL M PDP-ES • Communication and Control Communication and Control, cont’d Update the firmware as follows: 1 . V isit the Extron web site at www .extron.com. 2 . Select the IPL product category fr om the “Product Shortcut” drop-down box, and select the latest firmware file for download.
IPL M PDP-ES • Communication and Control IPL M PDP-ES • Communication and Control Communication and Control, cont’d If you wish to delete all files, click the Delete All button from the root directory . The file count reverts to 0, and all subsequent pages will be deleted.
IPL M PDP-ES • Communication and Control IPL M PDP-ES • Communication and Control Communication and Control, cont’d Control for Input 3 , Input 4 , and Input 5 is available only with use of the Expansion Solution video slots for the PDA-5003 or PDA-5004 interface card.
IPL M PDP-ES • Communication and Control IPL M PDP-ES • Communication and Control Communication and Control, cont’d Energy Save When an energy save function is selected, power consumption is reduced compared to the normal operating mode. When set to Auto, this sensor measur es the level of light inside the viewing room.
IPL M PDP-ES • Communication and Control Communication and Control, cont’d IPL M PDP-ES • Communication and Control example of each command in ASCII (T elnet) and URL Encoded (W eb). Upper and lower case text can be used interchangeably except where noted.
IPL M PDP-ES • Communication and Control IPL M PDP-ES • Communication and Control Communication and Contr ol There is a 7 character limit for full file names. It is advised that you use numeric titles (e.g., 1.eml, 24.eml). Numeric titles reduce the characters of the file name, and assist in keeping the alert files organized.
IPL M PDP-ES • Communication and Control IPL M PDP-ES • Communication and Control Communication and Contr ol command contains invalid parameters, it returns an erro r response to the host.
IPL M PDP-ES • Communication and Control IPL M PDP-ES • Communication and Control Communication and Control, cont’d 4-25 Command ASCII ( T elnet) URL Encoded (Web) Response IP Setup Commands Set.
IPL M PDP-ES • Communication and Control IPL M PDP-ES • Communication and Control Communication and Control, cont’d 4-27 4-26 Command ASCII ( T elnet URL Encoded (Web) Response Directories Chang.
IPL M PDP-ES • Communication and Control IPL M PDP-ES • Communication and Control Communication and Control, cont’d 4-29 4-28 Command ASCII ( T elnet) URL Encoded (Web) Response Ethernet Data Po.
IPL M PDP-ES • Communication and Control IPL M PDP-ES • Communication and Control Communication and Control, cont’d 4-31 . 4-30 3. At the < to > prompt, enter the IP address of the IPL M PDP-ES. (The default IP address is 192.168.254.254, but it may have been changed in the setup or configuration process.
IPL M PDP-ES • Communication and Control Communication and Control, cont’d IPL M PDP-ES A Appendix A Specifications, Part Numbers, and Accessories Specifications Parts 4-32 3.
IPL M PDP-ES • Specifications, Part Numbers, Accessories IPL M PDP-ES • Specifications, Part Numbers, Accessories Specifications, Part Numbers, and Accessories Parts Included parts Included parts .
IPL T S Series • Specifications, Part Numbers, and Accessories Specifications, Part Numbers, Accessories, cont’d IPL M PDP-ES B Appendix B Glossary A-4.
IPL M PDP-ES • Glossary IPL M PDP-ES • Glossary Glossary B-3 devices you have and your current list of IP addresses. W ith this information, GVC creates a GV for your specific devices. The GVC also compiles the event scripts and loads the GV and event scripts onto the box.
IPL M PDP-ES • Glossary IPL M PDP-ES • Glossary Glossary , cont’d B-5 B-4 Port number is a preassigned address within a server that pr ovides a direct route fr om the application to the T ransport layer , or from the T ransport layer to the application, of a TCP/IP system.
IPL M PDP-ES • Glossary Glossary , cont’d B-6.
Ein wichtiger Punkt beim Kauf des Geräts Extron electronic 68-1021-01 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Extron electronic 68-1021-01 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Extron electronic 68-1021-01 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Extron electronic 68-1021-01 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Extron electronic 68-1021-01 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Extron electronic 68-1021-01 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Extron electronic 68-1021-01 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Extron electronic 68-1021-01. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Extron electronic 68-1021-01 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.