Model 5081-P-FF/FI F OUNDA TION ® Fieldbus T wo-Wire pH/ORP T ransmitter Instruction Sheet PN 51A-5081P-FF-FI/rev .E January 201 1 ESSENTIAL INSTRUCTIONS READ THIS P AGE BEFORE PROCEEDING! Y our purchase from Rosemount Analytical, Inc. has resulted in one of the finest instruments available for your particular application.
MODEL 5081-P-FF/FI SPECIFICA TIONS SPECIFICA TIONS - GENERAL Housing: Cast aluminum with epoxy coating. NEMA 4X (IP65) and NEM A 7B. Neoprene O-ring cover seals. Dimensions: 6.3 in. x 6.9 in. x 6.4 in. (160 mm x 175 mm x 161 mm); diameter 6.1 in (155 mm) Conduit Openings: 3/4 in.
3 MODEL 5081-P-FF/FI WIRING SENSOR WIRING AND SET -UP Wire sensor per Figure 1. Refer to the sensor instruction manual for more details. If your sensor has an integral preamplifier or you are using a remote preamplifier , you will need to change the pream- plifier location in the program menu.
4 MODEL 5081-P-FF/FI WIRING FIGURE 2. Exploded View of Model 5081-P-FF/FI FIGURE 3. Wiring Diagram — Sensor with Preamplifier DWG . NO. REV . 45081P30 A.
5 WIRING THROUGH A JUNCTION BOX WITH REMOTE PREAMPLIFIER MODEL 5081-P-FF/FI WIRING FIGURE 4. Wiring diagram — sensor Model 381+ with preamplifier Wire sensor as shown in Figure 5. Refer to the sensor instruction manual for more details. FIGURE 5. Wiring Through a Junction Box with Remote Preamplifier DWG .
MODEL 5081-P-FF/FI INST ALLA TION 6 INST ALLA TION UNP ACKING AND INSPECTION Inspect the shipping container . If it is damaged, contact the shipper immediately for instructions. Save the box. If there is no apparent damage, unp ack the container . Be sure all items shown on the packing list are present.
7 FIGURE 8. FM Intrinsically Safe Inst allation Label.
8 FIGURE 7. FMRC Explosion-Proof Inst allation MODEL 5081-P-FF/FI HAZARDOUS AREA INST ALLA TION HAZARDOUS AREA INST ALLA TION.
9 FIGURE 9. FM Intrinsically Safe Inst allation (1 of 2).
10 FIGURE 9. FM Intrinsically Safe Inst allation (2 of 2).
11 FIGURE 10. CSA Intrinsically Safe Inst allation Label.
12 FIGURE 1 1. CSA Intrinsically Safe Inst allation (1 of 2).
FIGURE 1 1. CSA Intrinsically Safe Inst allation (2 of 2) 13.
FIGURE 12. A TEX Intrinsically Safe Inst allation Label 14.
FIGURE 13. A TEX Intrinsically Safe Inst allation (1 of 2) 15.
FIGURE 14. A TEX Intrinsically Safe Inst allation (2 of 2) 16.
17 W/O AGENCY APPROVAL REVISIO NS NO T PE RMIT TED REV REV REV REV REV REV CERTIFIED BY THIS DOCUMENT IS °C Tamb= 70 FM A 5/6/04 J. FLOCK 5/6/04 J. FLOCK .140 .125 1.30 ±. 0 2 2X.650 ±.0 1 5 2.56 ±. 0 2 2.180 .120 ±. 01 5 Ø .125 R .25 OR SUITABIL ITY FOR DIV.
18 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN I NCHES REMOVE B URRS & SHA RP EDGES .020 MAX MACHINED FI LLET RADII .020 MAX FINISH MATERIAL PROJEC T ENGR A P VD SIZE DWG NO. REV TITLE SCALE TYPE CHECKED DRAWN THIS DWG CREATE D IN DATE DESCRIPTION BILL OF M ATERIAL QTY ITEM PART NO.
B FM ANY FM APPROVED ASSOCIATED APPARATUS ANY FM APPROVED ASSOCIATED APPARATUS ANY FM APPROVED ASSOCIATED APPARATUS ANY FM APPROVED TERMINATOR ANY FM APPROVED INTRINSICALLY SAFE APPARATUS ANY FM APPRO.
20 IIC/ A,B,C,D,E,F,G IIB/ C,D,E,F ,G GROUPS 360 17.5 5 5081-P-FI 10 2.52 380 17.5 5 5081-P-FI FISCO PARAMETERS 5081-P-FI TABLE III MODEL NO. 10 5.32 Vmax (Vdc) Li (uH) Ci (nF) Pmax (W) Imax (mA) SUPPLY / SIGNAL TERM INALS TB 1-15, 16 La, Lt OR Lo; OR Lc/Rc (La/Ra OR Lo/Ro) AND Li/Ri (La/Ra OR L o/Ro) GROUPS GAS OUTPUT PA RAMETERS 25 21.
21 CLASS I, DIV. 2, GRPS A,B,C & D MODEL SA R LR34186 ROSEMO UNT ANALYT ICAL R WARNING-EXPLOSION H AZARD-DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON- HAZARDOUS. WARNING-EXPLOSION HAZARD-SUBSTITU- TION OF COMPONENTS M AY IMPAIR SUITABILITY FOR CLASS I, DIV 2.
22 Rosemount Analytical, Uniloc Division 2400 Ba rranca P kwy Irvine, CA 92606 UNLESS OTHERWISE SPECI FIED DIME NSIO NS AR E IN IN CHES REMOVE BUR RS & SHARP E DGES .020 M AX MACHINED FILLET RADII .020 MAX FINI SH MATE RIAL PROJE CT ENGR A PVD SIZE DWG NO.
23 9241502-01/ A DIMENSIONS ARE IN INCHES REMOVE BURRS & SHA RP EDGES .020 MAX MACHIN ED FILLET RADII .0 20 MAX - ITEM PART NO DESCRIPTION QT Y SCALE SIZE REV DW G NO BILL OF M ATERIAL MATERIAL FI.
24 Rosemount Analytical, Uniloc Division 2400 B arran ca Pkw y Irvin e, C A 92606 UN LESS OTH ERW ISE SPEC IFIE D DIMENSIONS ARE IN INCHES REMOVE BURR S & SHARP EDGES .020 M AX MACHINED FIL LET RADII .020 MAX FINISH MATE RIAL PROJECT ENGR AP VD SIZE DWG NO.
25 MODEL 5081-P-FF/FI INFRARED REMOTE CONTROLLER INFRARED REMOTE CONTROLLER (IRC) - KEY FUNCTIONS The infrared remote controller is used to calibrate and program the transmitter and to display diagnostic mes- sages. See figure below for a description of the function of the keys.
26 MODEL 5081-P-FF/FI ST ART -UP - pH ST ART -UP CONFIGURA TION AND CALIBRA TION — pH T o perform a two-point buffer calibration, follow these step s: 1. Place the pH sensor in the first buffer solution. 2. On the remote, press CAL, ENTER, ENTER. 3.
27 MODEL 5081-P-FF/FI ST ART -UP - ORP ST ART -UP CONFIGURA TION AND CALIBRA TION — ORP T o perform a one point standardization, follow these step s. 1. Place the ORP sensor in the ORP buffer solution. 2. On the Remote press CAL, ENTER, ENTER 3. Use the arrow buttons to adjust the value.
MODEL 5081-P-FF/FI MENU MNEMONICS 5081-P DISPLA Y MANUAL TEXT MEANING DBMJcsBuF CALIbrAtE Calibration menu Tue S td S tandardize sensor cG2! 0! cG3 bF1 / bF2 Buffer 1 / Buf fer 2 TMPQF SLOPE Sensor sl.
Ein wichtiger Punkt beim Kauf des Geräts Emerson 5081-P-FF/FI (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Emerson 5081-P-FF/FI noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Emerson 5081-P-FF/FI - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Emerson 5081-P-FF/FI reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Emerson 5081-P-FF/FI erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Emerson 5081-P-FF/FI besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Emerson 5081-P-FF/FI verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Emerson 5081-P-FF/FI. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Emerson 5081-P-FF/FI gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.