THERMOSTATS

EMERSON BLUE 2 ” THERMOSTATS

bLUE 2" THERMOSTATS - 2 SQ. IN. DISPLAY Heat Pump or Single Stage Models, easy to see Display Characters Offering a Step up from 70 Series.

Emerson 1F86-0244 — THERMOSTATS diagram (page 1)
Abb. 1

FEATURES

  • Heat Pump or Single Stage models.
  • Programmable, 5/1/1 Day, 24 Hour, 0-Day or Non-Programmable.
  • Gas, Oil, Electric, mV.
  • Cool Savings™ saves energy during peak A/C demand periods.
  • Lighted display for easier low light viewing.
  • Dual power - hardwired and/or battery powered.
  • Fits horizontal junction box.
  • Air filter change indicator option.

1F82-0261

Emerson 1F86-0244 — 1F82-0261 diagram (page 1)
Abb. 2

SPECIFICATIONS

Electrical Rating: Hardwire 20-30 VAC, NEC Class II 50/60Hz Battery Power mV to 30 VAC, NEC Class II, 50/60 Hz or DC Terminal Load 1.0 A per terminal, 1.5 A maximum all terminals combined Setpoint Range 45 to 90°F (7 to 32°C) Rated Differentials, Universal Models: Fast Med. Slow Heat (Single Stage) 0.8°F 1.2°F Cool (Single Stage) 1.2°F 1.7°F Heat Pump 1.2°F 1.7°F Aux./Emer Heat 0.8°F 1.2°F

1F89EZ-0251 (coming soon)

Rated Differentials, Single Stage Models: Fast Med. Slow Heat 0.6°F 0.8°F 1.2°F Cool 1.2°F 1.7°F Heat Pump 0.8°F 1.2°F Operating Ambient 32 to +105°F (0 to +41°C) Operating Humidity 90% non-condensing max. Shipping Temperature Range -4 to +150°F (-20 to +65°C) Dimension 33/4”H x 43/4”W x 11/2”D

Emerson 1F86-0244 — 1F89EZ-0251 (coming soon) diagram (page 1)
Abb. 3 · 1F89EZ-0251 (coming soon)

PARTS AND ACCESSORIES See end of this section for additional parts and accessories

  • F61-2634 — Wallplate 6½ ” W X 5 ” H, for use with or without horizontal junction box
  • F61-2648 — Wallplate (6 pack of F61-2634 above)
  • Thermostat Guards — see pages 24-25 for quick selection

1F86-0244

Emerson 1F86-0244 — 1F86-0244 diagram (page 1)
Abb. 4

1F86EZ-0251 (coming soon)

www.white-rodgers.com 14

Page 2 of the Emerson 1F86-0244 user manual — SINGLE STAGE THERMOSTATS – EMERSON BLUE 2 ” THERMOSTATS
Seite 2 · Zum Vergrößern klicken
Seite 2

EMERSON BLUE 2 ”

THERMOSTATS

THERMOSTATS

HEAT PUMP THERMOSTATS – EMERSON BLUE 2 ” THERMOSTATS

Emerson 1F86-0244 — THERMOSTATS diagram (page 2)
Abb. 5
Single StageMultiStageHeat PumpProgramsModelApplicationsThermostat Power Source*Selectable Performance FeaturesComfort and Convenience FeaturesTerminals Stages Heat/Cool by SystemProgram OptionsPeriods Per Day OptionsModel NumberGas / Oil / Electric3 Wire Zone ValveMillivolt CompatibleHumidity Control (H)-Humidity / (D)-DehumidifyAuto ChangeoverProgrammable FanEnergy Mgt. RecoveryKeypad Lockout (T)-Total / (P)-PartialSet-Point Temperature Limits Adjustable Max/MinIndoor Remote Sensors Max. Number + Thermostat Average and/or WeightedOutdoor Remote SensorDisplay Size Square inchesLighted DisplayMemory Back-Up (P)-Permanent / (B)-Battery 2/15+1+141F82-026133B, H32.03***PR, C, Y, W2, G, O/B, L 2/1Non-Programmable – Home-Sleep-Away1F89EZ-025133B, H2.03***PR, C, Y, W2, G, O/B, L 2/1ØØ1F89-021133B, H2.03***PR, C, Y, W2, G, O/B, L

SINGLE STAGE THERMOSTATS – EMERSON BLUE 2 ” THERMOSTATS

Emerson 1F86-0244 — SINGLE STAGE THERMOSTATS – EMERSON BLUE 2 ” THERMOSTATS diagram (page 2)
Abb. 6
Single StageMultiStageHeat PumpProgramsModelApplicationsThermostat Power Source*Selectable Performance FeaturesComfort and Convenience FeaturesTerminals Stages Heat/Cool by SystemProgram OptionsPeriods Per Day OptionsModel NumberGas / Oil / Electric3 Wire Zone ValveMillivolt CompatibleHumidity Control (H)-Humidity / (D)-DehumidifyAuto ChangeoverProgrammable FanEnergy Mgt. RecoveryKeypad Lockout (T)-Total / (P)-PartialSet-Point Temperature Limits Adjustable Max/MinIndoor Remote Sensors Max. Number + Thermostat Average and/or WeightedOutdoor Remote SensorDisplay Size Square inchesLighted DisplayMemory Back-Up (P)-Permanent / (B)-Battery 1/11/15+1+141F80-026133B, H32.03***PR, C, Y, W, G, O/B 1/11/124 Hours41F80-022433B, H32.03***PR, C, W, Y, G, O/B 1/11/1Non-Programmable – Home-Sleep-Away1F86EZ-025133B, H2.03***PR, C, Y, W, G, O/B 1/11/1ØØ1F86-024433B, H2.03***PR, C, Y, W, G, O/B

* H = Hardwired (Requires Common) ** Coming Soon B, H = Battery Powered or Hardwired *** Optional Continuous Display Light w/ Hardwire connection B = Battery Powered

Emerson 1F86-0244 — SINGLE STAGE THERMOSTATS – EMERSON BLUE 2 ” THERMOSTATS diagram (page 2)
Abb. 7

1F80-0224 / 1F80-0261 / 1F86-0422 / 1F87-0261. .Wiring Diagrams/Configuration See pages 153-154 1F82-0261 / 1F89-0211.. Wiring Diagrams/Configuration See pages 155-156

www.white-rodgers.com 15

** · **

Quellen

Referenzen & Links

In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.

Frage zu Emerson 1F86-0244 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Emerson 1F86-0244

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Emerson 1F86-0244 PDF-Anleitung

2 Seiten·1.6 MB·Thermostat·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…