Benutzeranleitung / Produktwartung 708 des Produzenten Emerson
Zur Seite of 44
www .rosemount.com Reference Manual 00809-0100- 4708, Rev AD September 20 12 Rosemount 708 Wireless Acoustic T ransmitter.
.
Reference Manual 00809-0100-47 08, Rev AD September 2012 Rosemount 708 Rosemount 708 Wireless Acoustic T ransmitter Rosemount 708 Hardware Revision HART ® Device Revision Field Communi cator Fi eld Device Revision 1 1 Dev v1, DD v1 NOTICE Read this manual before working with t he produ ct.
Reference Manual 00809-0100-4 708, Rev AD September 2012 Rosemount 708 Explosions could result in death or serious injury: Installation of this transmitter in an explos ive environment must be in accordance with the appropriate local, national, and international standards, cod es, and practices.
Reference Manual 00809-0100- 4708, Rev AD September 20 12 TOC -1 Rosemount 708 SECTION 1 Overview Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Warnings . . . . . . . . . . . . . . . . . . . . . . .
Reference Manual 00809-0100- 4708, Rev AD September 20 12 TOC -2 Rosemount 708 APPENDIX A Specifications and Reference Data Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Functional Specifications .
Reference Manual 00809-0100- 4708, Rev AD September 20 12 1- 1 Rosemount 708 Section 1 Overview Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1- 1 Overview . . . . . . . . . . . . . . . . . . . . . . . .
Reference Manual 00809-0100-47 08, Rev AD September 2012 Rosemount 708 1-2 OVERVIEW 708 T ransmitter Benefits of the Rosemoun t 708 include: • Improved energy efficiency and environmental com plianc.
Reference Manual 00809-0100- 4708, Rev AD September 20 12 1-3 Rosemount 708 Wireless Considerations Power Up Sequence The Smart Wireless Gateway (Gatew ay) should be installed and fun ctioning properly before any wir eless devices are powered.
Reference Manual 00809-0100-47 08, Rev AD September 2012 Rosemount 708 1-4 Field Communicator Connections The Power Module needs to be inst alled in the device for the Field Communicator to interface with the 708. This transmitter uses the Green Power Module; please or der model numbe r 701PGNKF .
Reference Manual 00809-0100- 4708, Rev AD September 20 12 1-5 Rosemount 708 Heat from the process is transfe rred to the tra nsmitter hou sing. If the process temperature is high, the am bient temperature will need to be lower to account for heat tr ansferred to the transm itter housing.
Reference Manual 00809-0100-47 08, Rev AD September 2012 Rosemount 708 1-6 PRODUCT RECYCLING/DISPOSAL Recycling of equipment and packaging sho uld be taken into consideration. The product and p ackaging should be disposed of in accordance with local and national legislation.
Reference Manual 00809-0100- 4708, Rev AD September 20 12 2-1 Rosemount 708 Section 2 Configuration Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p age 2-1 Device Configuration . . . . . . . . . . . . . . . . . . . .
Reference Manual 00809-0100-47 08, Rev AD September 2012 Rosemount 708 2-2 AMS ® Wireless Configurator AMS Wireless Configurator is cap able of connecting to de vices directly , using a HAR T modem, or rem otely using the Gateway .
Reference Manual 00809-0100- 4708, Rev AD September 20 12 2-3 Rosemount 708 Fast Key Sequence T able 2-1 lists the fast key sequenc e for common transmitter functions. T able 2-1. 708 Fast Key Sequence REMOVE POWER MODULE After the sensor and network have been configured, remove the p ower module and repl ace the po wer module cover .
Reference Manual 00809-0100-47 08, Rev AD September 2012 Rosemount 708 2-4 HART MENU T REE Figure 2-2. Field Communica tor Menu T ree.
Reference Manual 00809-0100- 4708, Rev AD September 20 12 3-1 Rosemount 708 Section 3 Mounting Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p age 3-1 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference Manual 00809-0100-47 08, Rev AD September 2012 Rosemount 708 3-2 Figure 3-1. T ransmitter Alignment Figure 3-2. T ransmitter Alignment T op View Figure 3-3. Power Module Installation NOTE: Wireless devices should be powered up in order of proximity fro m the Gateway , beginning wit h the closest dev ice to the Gateway .
Reference Manual 00809-0100- 4708, Rev AD September 20 12 3-3 Rosemount 708 Mounting Considerations 1. Mounting bands should be inspe cte d periodically and retightened if necessary . Some loosening may occur after initial inst allation due to thermal expa nsion/contraction.
Reference Manual 00809-0100-47 08, Rev AD September 2012 Rosemount 708 3-4.
Reference Manual 00809-0100- 4708, Rev AD September 20 12 4-1 Rosemount 708 Section 4 Commissioning Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p age 4-1 V erify Operation . . . . . . . . . . . . . . . . . . . . .
Reference Manual 00809-0100-47 08, Rev AD September 2012 Rosemount 708 4-2 Field Communicator For HART Wireless transmitter communica tion, a 708 DD is required. T o obtain the l atest DD, visit th e Emerson Process Management Easy Upgrad e site at: http://www2.
Reference Manual 00809-0100- 4708, Rev AD September 20 12 4-3 Rosemount 708 NOTE S teamLogic sof tware is provided for viewing steam trap st atus. Refer to the manual on the CD for more information.
Reference Manual 00809-0100-47 08, Rev AD September 2012 Rosemount 708 4-4 Field Communicator Use NOTE In order to communi cate with a Field Communicator , power the 70 8 by connecting the Power Module. Fo r more information on the Power Mo dule , refer to the Power Mo du le pr od u ct da ta sheet (Do cu m en t No 00813-0100- 4701).
Reference Manual 00809-0100- 4708, Rev AD September 2012 5-1 Rosemount 708 Section 5 Operation and Maintenance Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p age 5-1 Operation . . . . . . . . . . . . . . . . . . . .
Reference Manual 00809-0100-47 08, Rev AD September 2012 Rosemount 708 5-2 ALERT S The Rosemount 708 can be configured to report alerts based on the a coustic and temperat ure level meas ured. The Rosem ount 708 also re ports diagnostic alerts when there is a device malfunc tion.
Reference Manual 00809-0100- 4708, Rev AD September 2012 5-3 Rosemount 708 Device Alert Configuration Alert Levels The Rosemount 708 provides 4 user configur able alerts. Acoustic High - T riggers when acoustic level exceeds a user configured threshold.
Reference Manual 00809-0100-47 08, Rev AD September 2012 Rosemount 708 5-4 Figure 5-4. Inst all and Learn Alert Setup screen Alert Setup - Guided Use r Alert Setup Guided user alert setup cycles through on-screen p rompts to set the alert levels.
Reference Manual 00809-0100- 4708, Rev AD September 2012 5-5 Rosemount 708 Figure 5-6. Manual Alert Setup screen If a device is installed an d shows an unexpected alert, verify the installation conditions. POWER MODULE REPLACEMENT Expected power module life is ten years at reference conditions.
Reference Manual 00809-0100-47 08, Rev AD September 2012 Rosemount 708 5-6 Shipping Considerations The unit was shipped to you witho ut the power module inst alled. Please remove the power module pr ior to shipping. Each power module contains one “D” size pr imary lithium b attery .
Reference Manual 00809-0100- 4708, Rev AD September 2012 6-1 Rosemount 708 Section 6 T roubleshooting Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6-1 Safety Messages . . . . . . . . . . . . . . . . . . .
Reference Manual 00809-0100-47 08, Rev AD September 2012 Rosemount 708 6-2 T able 6-1. Maintenance and T roubleshooting Suggestions Symptom Corrective Actions Device T roubleshootin g Electronics Failure 1. Reset the device. 2. Reconfirm all configuration items in the device.
Reference Manual 00809-0100-47 08, Rev AD September 2012 A-1 Rosemount 708 Appendix A S pecifications and Reference Dat a Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-1 Dimensional Drawings . . . . . . . .
Reference Manual 00809-0100- 4708, Rev AD September 2012 Rosemount 708 A-2 Weight 708 with power module -0.59 5 kg (1 .3 1 lb) 708 without power mo dule - 0.
Reference Manual 00809-0100-47 08, Rev AD September 2012 A-3 Rosemount 708 DIMENSIONAL DRAWINGS Rosemount 708 Direct Mount Dimensions are in inches (millimeters).
Reference Manual 00809-0100- 4708, Rev AD September 2012 Rosemount 708 A-4 ORDERING INFORMATION T able A-1. Rosemount 708 Acoustic T ransmitter Ordering Information ★ The S tandard offering represents the most common options. The starred options ( ★ ) should be selected for best delivery .
Reference Manual 00809-0100- 4708, Rev AD September 2012 B-1 Rosemount 708 Appendix B Product Certifications Approved Manufacturing Locations . . . . . . . . . . . . . . . . . p age B-1 T elecommunication Compliance . . . . . . . . . . . . . . . . . .
Reference Manual 00809-0100-47 08, Rev AD September 2012 Rosemount 708 B-2 Hazardous Locations Certificates North American Certifications Factory Mutual ( FM) Approvals I5 Intrinsically Safe Intrinsic.
Reference Manual 00809-0100- 4708, Rev AD September 2012 B-3 Rosemount 708 IECEx System Ce rtifications I7 IECEx Intrinsic S afety Certificate No.: IECExBAS 1 1.0091X Ex ia IIC G a (T a = -40 °C T amb 70 °C) IP66/67 For use with SmartPower Solu tio ns, model number 701PGN green power module only .
Reference Manual 00809-0100-47 08, Rev AD September 2012 Rosemount 708 B-4 Figure B-1. Ro semount 70 8 FM Intrins ically Safe Installation Drawing c Master – PRINTED COPIES ARE UNCONTROLLED – Rose.
Reference Manual 00809-0100- 4708, Rev AD September 2012 C-1 Rosemount 708 Appendix C Recommended Practices Effective Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page C-1 All recommended practice s should be followed to ensure highest dat a reliability .
Reference Manual 00809-0100-47 08, Rev AD September 2012 Rosemount 708 C-2.
.
00809-0100-4708 Rev AD, 9/12 The Emerson logo is a trade mark and se rvice mar k of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount In c. PlantWeb is a registered trademark of one of t he Emerson Process Management group of companies.
Ein wichtiger Punkt beim Kauf des Geräts Emerson 708 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Emerson 708 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Emerson 708 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Emerson 708 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Emerson 708 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Emerson 708 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Emerson 708 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Emerson 708. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Emerson 708 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.