Inhaltsverzeichnis 34 Abschnitte Table of contents · 1 Please Read Immediately · 1.1 Important Information: · 1.2 Legal Regulations and Directives · … AnzeigenAusblenden
Page 1 of the Dimplex LIK 8MER user manual — Reversible Luft/WasserWärmepumpe für Innenaufstellung
Seite 1 · Zum Vergrößern klicken
Seite 1

LIK 8MER

Montageund GebrauchsanweisungDeutsch Installation and Operating InstructionsEnglish Instructions d’installation et d’utilisationFrançais
Dimplex LIK 8MER — LIK 8MER diagram (page 1)
Abb. 1
Dimplex LIK 8MER — LIK 8MER diagram (page 1)
Abb. 2
Dimplex LIK 8MER — LIK 8MER diagram (page 1)
Abb. 3
Dimplex LIK 8MER — LIK 8MER diagram (page 1)
Abb. 4

Reversible Luft/WasserWärmepumpe für Innenaufstellung

Reversible Air-to-Water Heat Pump for Indoor Installation

Pompe à chaleur air-eau réversible pour installation intérieure

Bestell-Nr. / Order no. / No de commande : 452160.66.23 FD 8611

Page 3 of the Dimplex LIK 8MER user manual — 1.3 Energy-Efficient Use of the Heat Pump
Seite 3 · Zum Vergrößern klicken
Seite 3

1 Please Read Immediately

1.2 Legal Regulations and Directives

The construction and design of the heat pump complies with all relevant EU directives, DIN/VDE regulations (see CE declaration of conformity).

1.1 Important Information:

When connecting the heat pump to the power supply, the rele- vant VDE, EN and IEC standards are to be fulfilled. Any further connection requirements stipulated by local utility companies must also be observed.

When connecting the heating and/or cooling system, all applica- ble regulations must also be adhered to.

Persons, especially children, who are not capable of operating the device safely due to their physical, sensory or mental abilities or their inexperience or lack of knowledge, must not operate this device without supervision or instruction by the person in charge.

Children must be supervised to ensure that they do not play with the device.

1.3 Energy-Efficient Use of the Heat Pump

With the purchase of this heat pump you are helping to protect the environment. A prerequisite for energy-efficient operation is the correct design of the heat source system and heating (radia- tors and circulation pump) or cooling system.

It is particularly important for the efficiency of a heat pump to keep the temperature difference between heating water and heat source as small as possible. For this reason, it is advisable to de- sign the heat source and heating system very carefully. A tem- perature difference of approx. one Kelvin (1 °C) increases the power consumption by around 2.5 %. When designing the heating system, it should be borne in mind that special consum- ers such as e.g. hot water preparation should also be considered and dimensioned for low temperatures. Underfloor heating systems (panel heating) are optimally suited for heat pump use on account of the low flow temperatures (30 °C to 40 °C).

It is important to ensure that the heat exchangers are not con- taminated during operation because this increases the tempera- ture difference, in turn reducing the COP.

Correct adjustment of the heat pump controller is also important for energy-efficient use of the heat pump. Further information can be found in the heat pump controller's operating instructions.

The heat pump is equipped with an overflow mechanism to pre- vent very low flow rates in the heat pump.

The installed buffer tank increases the amount of water in the heating circuit and guarantees reliable defrosting.

Page 4 of the Dimplex LIK 8MER user manual — Cooling
Seite 4 · Zum Vergrößern klicken
Seite 4

2 Purpose of the Heat Pump

3 Scope of Delivery

3.1 Basic Device

2.1 Application

The compact heat pump is supplied complete with all of the im- portant components of the heating circulation system:

The air-to-water heat pump is designed for use in existing or newly built heating systems.

„ Heat circulating pump

It is designed exclusively for heating and cooling heating water!

„ Overflow valve and safety components (pressure relief

In heating operation, the heat pump is suitable for mono energy and bivalent operation down to an external temperature of - 20 °C.

R404A is used as the refrigerant.

Dimplex LIK 8MER — 2 Purpose of the Heat Pump diagram (page 4)
Abb. 5 · 2 Purpose of the Heat Pump

Proper defrosting of the evaporator is guaranteed by maintaining a heating water return flow temperature of more than 18 °C dur- ing continuous operation.

The heat pump is not designed for the increased heat consump- tion required when a building is being dried out. The additional heat consumption should be met using special devices provided by the customer. If a building is to be dried out in autumn or win- ter, we recommend installing an additional heating element (available as an accessory).

In cooling operation the heat pump is suitable for temperatures ranging from +15 °C to +40 °C.

It can be used for silent and dynamic cooling. The minimum water temperature is +7 °C.

2.2 Operating Principle

Heating

Outside air is drawn in by the ventilator and fed via the evapora- tor (heat exchanger). The evaporator cools the air, i.e. it extracts heat from it. This extracted heat is then transferred to the working medium (refrigerant) in the evaporator.

The heat is “pumped” to a higher temperature level by increasing its pressure with the aid of an electrically driven compressor. It is then transferred to the heating water using the liquifier (heat ex- changer).

1. Evaporator (heating operation)
2. Ventilator
3. 24 l expansion vessel

Electrical energy is used to raise the temperature of the heat in the environment to a higher level. Because the energy extracted from the air is transferred to the heating water, this type of device is called an air-to-water heat pump.

4. Switch box
5. Liquifier (heating operation)
6. Compressor

The air-to-water heat pump consists of the main components evaporator, ventilator and expansion valve, as well as the low- noise compressor, liquifier and electrical control system.

7. Overflow valve
8. Heat circulating pump
9. Buffer tank

At low ambient temperatures, humidity accumulates on the evap- orator in the form of frost reducing the transfer of heat. The evap- orator is defrosted automatically by the heat pump as required. Steam may be emitted from the air outlet depending on the at- mospheric conditions.

10. Filter dryer
11. Inspection window
12. Expansion valve

Cooling

The functions of the evaporator and the liquifier are reversed in the “Cooling” operating mode.

The heating water transfers its heat to the refrigerant via the liq- uifier which is now functioning as an evaporator. The compressor raises the temperature level of the refrigerant and the heat is passed on to the surrounding air via the liquifier (functioning as an evaporator in heating operation).

„ Expansion vessel · valve, pressure gauge) ·

Page 5 of the Dimplex LIK 8MER user manual — Contents:
Seite 5 · Zum Vergrößern klicken
Seite 5

4 Transport

3.2 Switch Box

The switch box is located in the heat pump. It can be accessed by removing the lower front cover.

The switch box contains the supply connection terminals, as well the power contactors, the soft starter unit and the heat pump manager.

Use a wooden pallet for transporting the heat pump to the final in- stallation location. The basic device can be transported with a lift truck, hand truck or by means of 3/4" pipes fed through the holes in the base plate or frame.

The heat pump manager is a convenient electronic regulation and control device. It controls and monitors the entire heating or cooling system on the basis of the external temperature, includ- ing hot water preparation and safety systems.

Dimplex LIK 8MER — 4 Transport diagram (page 5)
Abb. 6 · 4 Transport

The customer must install the external temperature sensor, which is included in the scope of supply of the heat pump control- ler together with the necessary fixing accessories.

The enclosed operating instructions describe the function and use of the heat pump manager.

3.3 Accessories Pack

Contents:

2 Sealing rings for duct connection

3 1" connecting hoses 3 1" double nipples 6 1" flat gaskets 1 1" sealing plug 1 Hose nozzle for filling and drain cock

2 Fixing brackets 2 10-mm dowels 2 8 x 80 screws 4 M4 x 8 screws

1 External sensor 1 6-mm dowels 1 4.5 x 50 screws

Before using the holes in the frame, it is advisable to remove each of the side panel assemblies. This is done by loosening each of the two screws at the base and then withdrawing the panels by unhooking them from above. Rehang the panels by gently pushing them in an upwards direction.

Dimplex LIK 8MER — Contents: diagram (page 5)
Abb. 7 · Contents:
Dimplex LIK 8MER — Contents: diagram (page 5)
Abb. 8 · Contents:

Opening the cover Closing the cover

Page 6 of the Dimplex LIK 8MER user manual — 5.3 Sound
Seite 6 · Zum Vergrößern klicken
Seite 6

5 Set-UP

6 Installation

5.1 General Information

6.1 General Information

The heat pump is designed for installation in a corner. Other in- stallation locations are also possible in combination with an air duct (available as an accessory) on the air outlet side.

The following connections need to be established on the heat pump:

„ Fresh and exhaust air

The unit must be installed indoors on a level, smooth and hori- zontal surface. The entire base of the frame should lie directly on the floor to ensure a good soundproof seal. If this is not the case, additional sound insulation measures may be necessary.

„ Flow and return flow of the heating system

„ Outflow for the pressure relief valve

The heat pump must be installed so that maintenance work can be carried out without being hindered. This can be ensured by maintaining a clearance of 1 m in front and to the left of the heat pump. The side panel assemblies must not be covered by connecting pipes.

6.2 Air Connection

The air intake opening of the device is solely designed for direct connection to a wall opening. The wall opening can be provided with air duct and sealing collar for this purpose. See the illustra- tion in the appendix under Installation Dimensions.

P

The glass fibre reinforced concrete air ducts offered as accesso- ries are moisture-resistant and diffusion-free.

The sealing collar is used to seal the air ducts on the heat pump. The air ducts are not screwed directly onto the heat pump. Only the rubber seal comes into direct contact with the heat pump when the system is installed correctly. This guarantees easy as- sembly and disassembly of the heat pump and also ensures that solid-borne sound is well insulated.

P

Never install the device in rooms subject to high humidity. Con- densation can form on the heat pump and air circuit if the humid- ity exceeds 50 % and the external temperature is below 0 °C.

If the heat pump is installed on an upper storey, the load-bearing capacity of the ceiling should be checked. On account of the acoustics, measures for isolating possible vibrations should also be very carefully planned in advance as well. Installation on a wooden floor is not recommended.

5.2 Condensed Water Pipe

Condensed water that forms during operation must be drained off frost-free. The heat pump must be mounted on a level plane to guarantee proper drainage. The condensed water pipe must have a minimum diameter of 50 mm and should be fed frost-free into a sewer. Condensate should not be discharged directly into clearing tanks and cesspits because the aggressive vapours could destroy the evaporator.

It must also be ensured that the interior side of the wall opening is lined with thermal insulation to prevent the wall from becoming cold and to prevent moisture from penetrating the wall. The en- closed fixing accessories can be used for attachment to the wall.

5.3 Sound

To prevent solid-borne sound from being transmitted to the heat- ing system, a vibration-damped connection should be used for connecting the heat pump with the heating system (install the supplied hose connections free of strain).

Installed air ducts should be sound-isolated from the heat pump to prevent the transmission of solid-borne sound to the ducts.

If both air openings are connected directly to a wall opening, the ventilator terminals can be reversed from a delta to a star con- nection (see information in the ventilator terminal box).

„ Condensate outflow · „ Power supply

Page 7 of the Dimplex LIK 8MER user manual — 6.3 Heating System Connection
Seite 7 · Zum Vergrößern klicken
Seite 7
Dimplex LIK 8MER — 6.3 Heating System Connection diagram (page 7)
Abb. 9 · 6.3 Heating System Connection

An overflow valve is installed in the device for systems in which the heating water flow can be shut off via the radiator or thermo- stat valves. This ensures a minimum heating water flow rate through the heat pump and helps to avoid faults.

Once the heating system has been installed, it must be filled, de- aerated and pressure-tested.

The integrated expansion vessel has a volume of 24 litres. This volume is suitable for buildings with a living space area to be heated of maximum 200 m².

The volume should be checked by the heating system engineer. If necessary, an additional expansion vessel must be installed (according to DIN 4751, Part 1). The tables listed in the manufac- turers' catalogues simplify dimensioning the system on the basis of the water content. Allow for a buffer tank volume of 80 litres when making the calculation.

The air outlet can be optionally mounted directly to a wall open- ing or to a longer duct (available as an accessory). Use the same mounting procedure as for the air inlet.

Antifreeze

If a flange-mounted air duct is used on the air outlet side, it is se- cured with 4 M8 x 16 hexagon bolts in the threaded holes pro- vided. When doing this, ensure that the air duct stubs only touch the insulation. There should be no contact with the external sheeting.

A method of manual drainage (see illustration) should be pro- vided for heat pumps which are exposed to frost. The antifreeze function of the heat pump controller is active whenever the con- troller and the heat circulating pumps are ready for operation. If the heat pump is taken out of service or in the event of a power failure, the system has to be drained. The heating circuit should be operated with a suitable antifreeze if heat pump systems are implemented in buildings where a power failure can not be de- tected (holiday home).

Dimplex LIK 8MER — Antifreeze diagram (page 7)
Abb. 10 · Antifreeze
Dimplex LIK 8MER — Antifreeze diagram (page 7)
Abb. 11 · Antifreeze

6.4 Electrical Connection

The power supply and control voltage are supplied using stand- ard cables (load: 3-core, control: 3-core).

Observe the external and internal dimensions as specified in the figure. Also ensure that the vibration and duct isolation are ade- quate.

A disconnecting device with a contact gap of at least 3 mm (e.g. utility blocking contactor or power contactor) as well as a 1-pole circuit breaker must be installed in the power supply by the cus- tomer (tripping current in compliance with the Device Informa- tion).

6.3 Heating System Connection

To enable connection to the heating system, flexible hose con- nection pieces and double nipples with a 1" external thread are included with the heat pump. These allow the optional use of a threaded or flat gasket connection to the heating system. If the heat pump is not intended to be used to heat up the hot wa- ter, the hot water output must be permanently sealed using the supplied sealing plug.

The control voltage must be protected by a 10 A fuse. See Ap- pendix Circuit Diagrams for detailed information.

Before connecting the heating water system to the heat pump, the heating system must be flushed to remove any impurities, residue from sealants, etc. Any accumulation of deposits in the liquifier could cause the heat pump to completely break down.

Page 8 of the Dimplex LIK 8MER user manual — 7.3 Start-Up Procedure
Seite 8 · Zum Vergrößern klicken
Seite 8

7 Start-UP

Heat source temperatureMax. temperature spread between heating flow and return flow FromTo -20 °C-15 °C4 K -14 °C-10 °C5 K -9 °C-5 °C6 K -4 °C0 °C7 K 1 °C5 °C8 K 6 °C10 °C9 K 11 °C15 °C10 K 16 °C20 °C11 K 21 °C25 °C12 K 26 °C30 °C13 K 31 °C35 °C14 K

7.1 General Information

To ensure that start-up is performed correctly, it should only be carried out by an after-sales service technician authorised by the manufacturer. This may be a condition for extending the guaran- tee (see Warranty Service). Start-up should be carried out in heating operation.

7.2 Preparation

The following items need to be checked prior to start-up:

„ All of the heat pump connections must be established as de-

scribed in Chapter 6.

„ All valves that could impair the proper flow of the heating

Any faults occurring during operation are also displayed on the heat pump controller and can be corrected as described in the operating instructions of the heat pump controller.

water in the heating circuit must be open.

„ The air intake and air outlet paths must be clear.

„ The ventilator must turn in the direction indicated by the ar-

For external temperatures below 10 °C and heating water tem- peratures below 16 °C, the buffer tank should be heated up with the 2nd heat generator to at least 25 °C.

row.

„ The heat pump controller must be adapted to the heating

system in accordance with the controller's operating instruc- tions.

Observe the following procedure to implement a smooth start-up:

1. Close all of the heating circuits.

„ Ensure the condensate outflow functions.

2. Fully open the overflow valve.

„ The outflow from the heating water pressure relief valve

3. Use the controller to select the automatic operating mode.

must also function correctly.

4. Wait until the buffer tank has reached a temperature of at least 25 °C.

„ De-aeration of the heating system:

Ensure that all heating circuits are open and the heat circu- lating pump is operating (level III). Connect the voltage to the heat pump controller. Select the heat generator 2 operating mode and de-aerate the system at its highest point. Top up with water if required (maintain static minimum pressure).

5. Now slowly reopen the heating circuit valves in succession so that the heating water throughput is constantly raised by slightly opening the respective heating circuit. The heating water temperature in the buffer tank must not be allowed to drop below 20 °C during this process. This ensures that the heat pump can be defrosted at any time.
6. Set the minimum volume flow quantity on the overflow valve and heat circulating pump when all heating circuits are fully open and a heating water temperature in the buffer tank of approx. 20 °C is maintained.

7.3 Start-Up Procedure

The heat pump is started up via the heat pump controller. Adjust- ments should be made in compliance with the instructions.

The performance level of the circulating pump must be adapted to the respective heating system.

7. New buildings have an increased heat consumption on account of the energy required to dry them out. This increased heat consumption means that marginally dimensioned heating systems can not always achieve the desired room temperature. In such cases, we recommend keeping a 2nd heat generator on standby during the first heating period. The limit temperature on the heat pump controller should also be turned up to 15 °C.

The overflow valve must be adjusted to the requirements of the respective heating system. Incorrect adjustment can lead to faulty operation and increased energy consumption. We recom- mend carrying out the following procedure to correctly adjust the overflow valve:

Close all of the heating circuits that may also be closed during operation (depending on the type of heat pump usage) so that the most unfavourable operating state - with respect to the water flow rate - is achieved. This normally means the heating circuits of the rooms on the south and west sides of the building. At least one heating circuit must remain open (e.g. bathroom).

The overflow valve should be opened far enough to produce the maximum temperature spread between the heating flow and re- turn flow listed in the following table for the current heat source temperature. The temperature spread should be measured as close as possible to the heat pump. The heating element of mono energy systems should be disconnected.

Page 9 of the Dimplex LIK 8MER user manual — 10 Decommissioning/ Disposal
Seite 9 · Zum Vergrößern klicken
Seite 9

8 Maintenance / Cleaning

8.3 Cleaning the Air System

Air ducts, evaporator, ventilator and condensate outflow should be cleaned of contamination (leaves, twigs, etc.) before the heat- ing period. Do this by opening the left and front sides of the heat pump. The bottom should be opened first followed by the top.

8.1 Maintenance

To protect the paintwork, avoid leaning or putting objects on the device. External heat pump parts can be wiped with a damp cloth and domestic cleaner.

Remove and rehang the side panel assemblies as described in Chapter 4.

To prevent faults due to sediment in the heat exchanger of the heat pump, ensure that the heat exchanger in the heating system can not be contaminated. We recommend protecting the evapo- rator by installing a bird guard in the inlet duct. At least 80 % of the cross section of the grating should be open. In the event that operating malfunctions due to contamination still occur, the sys- tem should be cleaned as described below.

To prevent the evaporator and the condensate tray from being damaged, do not use hard or sharp objects for cleaning.

9 Faults / TroubleShooting

8.2 Cleaning the Heating System

This heat pump is a quality product and is designed for trouble- free and maintenance-free operation. In the event that a fault should occur, it will be shown on the heat pump manager display. Simply consult the Faults and Trouble-shooting page in the oper- ating instructions of the heat pump manager. If you cannot cor- rect the fault yourself, please contact your after-sales service technician.

The ingress of oxygen into the heating water circuit may result in the formation of oxidation products (rust), particularly if steel components are used. These products enter the heating system via the valves, the circulating pumps and/or plastic pipes. It is therefore essential - in particular with respect to the piping of un- derfloor heating systems - that only diffusion-proof materials are used.

10 Decommissioning/ Disposal

Residue from lubricants and sealants may also contaminate the heating water.

In the case of severe contamination leading to a reduction in the performance of the liquifier in the heat pump, the system must be cleaned by a heating technician.

Before removing the heat pump, disconnect it from the power source and close all valves. Observe all environmentally-relevant requirements regarding the recovery, recycling and disposal of materials and components in accordance with all applicable standards. Particular attention should be paid to the proper dis- posal of refrigerants and refrigeration oils.

According to today's state of knowledge, we recommend using a 5 % phosphoric acid solution for cleaning purposes. However, if cleaning needs to be performed more frequently, a 5 % formic acid solution should be used.

In either case, the cleaning fluid should be at room temperature. We recommend flushing the heat exchanger in the direction op- posite to the normal flow direction.

To prevent acidic cleaning agents from entering the heating sys- tem circuit, we recommend connecting the flushing device di- rectly to the flow and return flow of the liquifier of the heat pump.

It is important that the system be thoroughly flushed using appro- priate neutralising agents to prevent any damage from being caused by cleaning agent residue remaining in the system.

Acids must be used with great care and all relevant regulations of the employers' liability insurance associations must be adhered to.

If in doubt, contact the manufacturer of the chemicals!

The buffer tank is drained using the filling and drain cocks on the lower left of the device. Also open the ball valve on the pressure expansion vessel to vent the buffer tank.

Page 10 of the Dimplex LIK 8MER user manual — 11 Device Information
Seite 10 · Zum Vergrößern klicken
Seite 10

11 Device Information

1 Type and order codeLIK 8MER 2 Design 2.1 ModelCompact 2.2 Degree of protection according to EN 60 529 for compact devices and heating componentsIP 20 2.3 Installation locationIndoors 3 Performance data 3.1 Operating temperature limits: Heating water flow/return flow °C / °CUp to 58 / above 18 Cooling, flow °C+7 to +20 Air (heating) °C-25 to +35 Air (cooling) °C+15 to +40 3.2 Temperature spread of heating water at A7 / W3510.05.0 3.3 Heat output / COP at A-7 / W35 1 kW / ---5.8 / 2.75.5 / 2.6 at A-7 / W45 1 kW / ---5.4 / 2.1 at A2 / W35 1 kW / ---7.5 / 3.37.4 / 3..2 at A7 / W35 1 kW / ---9.3 / 3,99.2 / 3.8 at A7 / W45 1 kW / ---8.8 / 3.2 at A10 / W35 1 kW / ---9.8 / 4.19.7 / 4.0 3.4 Temperature spread of cooling water at A35 / W77.55.0 3.5 Cooling capacity / COP at A27 / W7 kW / ---7.9 / 2.77.9 / 2.6 at A27 / W18 kW / ---9.6 / 3.29.6 / 3.2 at A35 / W7 kW / ---7.0 / 2.06.9 / 2.0 at A35 / W18 kW / ---8.5 / 2.48.5 / 2.4 3.6 Sound power level device / outdoors dB(A)53 / 60 3.7 Sound pressure level at a distance of 1 m (indoors) dB(A)48.0 3.8 Heating water flow with an internal pressure differential of 2 m³/h / Pa0.8 / 27001.6 / 11900 3.9 Free pressure, heating circulating pump (heating, max. stage)Pa4500027000 3.10 Cooling water flow with an internal pressure differential of m³/h / Pa0.8 / 27001.2 / 6500 3.11 Free pressure, circulating pump (cooling, max. stage) Pa4500037000 3.12 Air flow rate with an external static pressure differential of m³/h / Pa2500 / 20 3.13 Refrigerant; total filling weight type / kgR404A / 3.3 3.14 Output of electric heating element (second heat generator)kW2.0 4 Dimensions, connections and weight 4.1 Device dimensions H x W x L cm190 x 75 x 68 4.2 Device connections to heating system InchG 1'' external 4.3 Air duct inlet and outlet (min. internal dimensions) L x W cm44 x 44 4.4 Weight of the transportable unit(s) incl. packing kg250 4.5 Buffer tank volume l50 4.6 Buffer tank pressure rating bar6 5 Electrical Connection 5.1 Nominal voltage; fuse protection V / A230 / 20 5.2 Nominal power consumption 1 A2 W35 kW2.272.33 5.3 Starting current with soft starter A30 5.4 Nominal current A2 W35 / cos ϕ A / ---12.3 / 0.812.7 / 0.8 6 Complies with the European safety regulations3 7 Additional model features 7.1 DefrostingAutomatic Type of defrostingReverse cycle Defrosting tray includedYes (heated) 7.2 Heating water in device protected against freezing 4Yes 7.3 Performance levels1 7.4 Controller internal/externalInternal
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: External temperature 2 °C and heating water flow temperature 55 °C.
2. The heat circulating pump is integrated.
3. See CE declaration of conformity
4. The heat circulating pump and the heat pump controller must always be ready for operation.
Page 11 of the Dimplex LIK 8MER user manual — www.dimplex.de A-I
Seite 11 · Zum Vergrößern klicken
Seite 11

Anhang / Appendix / Annexes

1 Maßbilder / Dimension Drawings / Schémas cotés A-II

1.1 Wärmepumpe / Heat pump / Pompe à chaleur A-II 1.2 Einbaumaße / Installation Dimensions / Cotes de montage A-III

2 Diagramme / Diagrams / Diagrammes A-IV

2.1 Heizbetrieb / Heating Operation / Mode chauffage A-IV 2.2 Kühlbetrieb / Cooling Operation / Mode refroidissement A-V

3 Stromlaufpläne / Circuit Diagrams / Schémas électriques A-VI

3.1 Steuerung Standardregler / Control of the standard controller / Commande régulateur standard A-VI 3.2 Steuerung Kühlregler / Control of the cooling controller / Commande régulateur standard A-VII 3.3 Last / Load / Charge A-VIII 3.4 Anschlussplan Standardregler / Terminal diagram for the standard controller / Schéma électrique du régulateur standard A-IX 3.5 Anschlussplan Kühlregler / Terminal diagram for the cooling controller / Schéma électrique du régulateur refroidissement A-X 3.6 Legende / Legend / Légende A-XI

4 Hydraulisches Prinzipschema / Hydraulic Plumbing Diagram / Schéma hydraulique A-XIII

Anhang · Appendix · Annexes

4.1 Darstellung / Schematic view / Représentation A-XIII 4.2 Legende / Legend / Légende A-XIV

5 Konformitätserklärung / Declaration of Conformity / Déclaration de conformité A-XV

www.dimplex.de A-I

Frage zu Dimplex LIK 8MER stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Dimplex LIK 8MER

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Dimplex LIK 8MER PDF-Anleitung

26 Seiten·1.7 MB·Wärmepumpe·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…