1 Please read immediately

1.2 Legal Regulations and Directives

The construction and design of the heat pump complies with all relevant EU directives, DIN/VDE regulations (see CE declaration of conformity).

1.1 Important information:

When connecting the heat pump to the power supply, the rele- vant VDE, EN and IEC standards are to be fulfilled. Any further connection requirements stipulated by local utility companies must also be observed.

When connecting the heating system, all applicable regulations must also be adhered to.

1.3 Energy-Efficient Use of the Heat Pump

With the purchase of this heat pump you are helping to protect the environment. A prerequisite for energy-efficient operation is the correct design of the heat source system and heating system (radiators and circulation pump).

It is particularly important for the efficiency of a heat pump to keep the temperature difference between heating water and heat source as small as possible. For this reason, it is advisable to de- sign the heat source and heating system very carefully. A tem- perature difference of approx. one Kelvin increases the power consumption by around 2.5 %. When designing the heating system, it should be borne in mind that special consum- ers such as e.g. hot water preparation should also be considered and dimensioned for low temperatures. Underfloor heating systems (panel heating) are optimally suited for heat pump use on account of the low flow temperatures (30 °C to 40 °C).

It is important to ensure that the heat exchangers are not con- taminated during operation because this increases the tempera- ture difference, in turn reducing the COP.

Correct adjustment of the heat pump controller is also important for energy-efficient use of the heat pump. Further information can be found in the heat pump controller's operating instructions.

Page 2 of the Dimplex LI 11MS user manual —
Seite 2 · Zum Vergrößern klicken
Seite 2

2 Purpose of the Heat Pump

3 Scope of delivery

3.1 Basic Device

2.1 Application

The compact heat pump is supplied complete with all the compo- nents listed below.

The air-to-water heat pump is designed for use in existing or newly built heating systems.

R404A is used as the refrigerant.

It is designed exclusively for heating domestic and heating water!

The heat pump is suitable for mono energy and bivalent opera- tion down to an external air temperature of -20 °C.

Dimplex LI 11MS —    diagram (page 2)
Abb. 1

Proper defrosting of the evaporator is guaranteed by maintaining a heating water return flow temperature of more than 18 °C or 20 °C (see Appendix Operating Range) during continuous oper- ation.

The heat pump is not designed for the increased heat consump- tion required when a building is being dried out. The additional heat consumption should be met using special devices provided by the customer. If a building is to be dried out in autumn or win- ter, we recommend installing an additional heating element (available as an accessory).

2.2 Operating Principle

Outside air is drawn in by the ventilator and fed via the evapora- tor (heat exchanger). The evaporator cools the air, i.e. it extracts heat from it. This extracted heat is then transferred to the working medium (refrigerant) in the evaporator.

The heat is “pumped” to a higher temperature level by increasing its pressure with the aid of an electrically driven compressor. It is then transferred to the heating water using the liquifier (heat ex- changer).

Electrical energy is used to raise the temperature of the heat in the environment to a higher level. Because the energy extracted from the air is transferred to the heating water, this type of device is called an air-to-water heat pump.

1. Evaporator
2. Check valve
3. Ventilator

The air-to-water heat pump consists of the main components evaporator, ventilator and expansion valve, as well as the low- noise compressor, liquifier and electrical control system.

4. Switch Box
5. Controllers
6. Filter dryer

At low ambient temperatures, humidity accumulates on the evap- orator in the form of frost reducing the transfer of heat. The evap- orator is defrosted automatically by the heat pump as required. Steam may be emitted from the air outlet depending on the at- mospheric conditions.

7. Liquifier
8. Expansion valve
9. Compressor
Page 3 of the Dimplex LI 11MS user manual — 3.3 Heat pump controller
Seite 3 · Zum Vergrößern klicken
Seite 3

4 Transport

3.2 Switch Box

The switch box is located in the heat pump. It can be swung out after removing the lower front cover and loosening the fastening screw located in the upper right-hand corner.

The switch box contains the supply connection terminals as well the power contactors and the soft starter unit.

Use a wooden pallet for transporting the heat pump to the final in- stallation location. The basic device can be transported with a lift truck, hand truck or by means of 3/4" pipes fed through the holes in the base plate or frame.

The power supply cable and control line are installed ready for use.

3.3 Heat pump controller

Dimplex LI 11MS — 3.3 Heat pump controller diagram (page 3)
Abb. 2 · 3.3 Heat pump controller

The heat pump controller is a convenient electronic regulation and control device. It controls and monitors the entire heating system on the basis of the external temperature, including hot water preparation and safety systems.

The customer must install the external temperature sensor, which is included in the scope of supply of the heat pump control- ler together with the necessary fixing accessories.

The enclosed operating instructions describe the function and use of the heat pump controller.

Before using the transport holes in the frame, it is necessary to remove the lower side panel assemblies. This is done by loosen- ing each of the two screws at the base and then withdrawing the panels by unhooking them from above. Rehang the panels by gently pushing them in an upwards direction.

Be careful not to damage any components when inserting the pipes through the frame.

Dimplex LI 11MS — 3.3 Heat pump controller diagram (page 3)
Abb. 3 · 3.3 Heat pump controller

Opening the cover Closing the cover

Show 5 more labels / short text on this page
· · · ·
Page 4 of the Dimplex LI 11MS user manual — 5.3 Sound
Seite 4 · Zum Vergrößern klicken
Seite 4

5 Installation

6 Installation

5.1 General Information

6.1 General Information

The unit must be installed indoors on a level, smooth and hori- zontal surface. The entire base of the frame should lie directly on the floor to ensure a good soundproof seal. If this is not the case, additional sound insulation measures may be necessary. If the device is installed on top of a built-under buffer tank, a surface that fully supports the base is required. The heat pump must be installed so that maintenance work can be carried out without being hindered. This can be ensured by maintaining a clearance of 1 m in front and to the left and right of the heat pump.

The following connections need to be established on the heat pump:

„ Fresh and exhaust air

„ Flow and return flow of the heating system

„ Control line to the heat pump controller

6.2 Air Connection

P

P

P

The glass fibre reinforced concrete air ducts offered as accesso- ries are moisture-resistant and diffusion-free.

The sealing collar is used to seal the air ducts on the heat pump. The air ducts are not screwed directly onto the heat pump. Only the rubber seal comes into direct contact with the heat pump when the system is installed correctly. This guarantees easy as- sembly and disassembly of the heat pump and also ensures that solid-borne sound is well insulated.

P

Never install the device in rooms subject to high humidity. Con- densation can form on the heat pump and air circuit if the humid- ity exceeds 50 % and the external temperature is below O °C.

If the heat pump is installed on an upper storey, the load-bearing capacity of the ceiling should be checked. On account of the acoustics, measures for isolating possible vibrations should also be very carefully planned in advance as well. Installation on a wooden floor is not recommended.

5.2 Condensed Water Pipe

Condensed water that forms during operation must be drained off frost free. The heat pump must be mounted on a level plane to guarantee proper drainage. The condensed water pipe must have a minimum diameter of 50 mm and should be fed frost-free into a sewer. Condensate should not be discharged directly into clearing tanks and cesspits because the aggressive vapours could destroy the evaporator.

If another type of air duct is used, observe the external and inter- nal dimensions as specified in the figure. Also ensure that the vi- bration and duct insulation are adequate.

5.3 Sound

If flange-mounted air ducts are used, connecting stubs are se- cured on the air inlet and air outlet sides of the evaporator with 4 M8 x 16 hexagon bolts in the threaded holes provided. When doing this, ensure that both air duct stubs only touch the insula- tion. There should be no contact with the external sheeting.

To prevent solid-borne sound from being transmitted to the heat- ing system, we recommend connecting the heat pump to the heating system using a flexible hose.

Installed air ducts should be sound-isolated from the heat pump to prevent the transmission of solid-borne sound to the ducts.

„ Condensate outflow · „ Power supply

Page 5 of the Dimplex LI 11MS user manual — Minimum heating water flow rate
Seite 5 · Zum Vergrößern klicken
Seite 5
Dimplex LI 11MS — 6.3 Heating System Connection diagram (page 5)
Abb. 4 · 6.3 Heating System Connection

Antifreeze (frost protection)

A method of manual drainage (see illustration) should be pro- vided for heat pumps which are exposed to frost. The antifreeze function of the heat pump controller is active whenever the con- troller and the heat circulating pump are ready for operation. If the heat pump is taken out of service or in the event of a power failure, the system has to be drained. The heating circuit should be operated with a suitable antifreeze if heat pump systems are implemented in buildings where a power failure can not be de- tected (holiday home).

Dimplex LI 11MS — Antifreeze (frost protection) diagram (page 5)
Abb. 5 · Antifreeze (frost protection)

6.3 Heating System Connection

The heating system connections on the heat pump have a 1" external thread. Use a spanner to firmly grip the transitions when connecting the heat pump.

6.4 Electrical Connection

Before connecting the heating water system to the heat pump, the heating system must be flushed to remove any impurities, residue from sealants, etc. Any accumulation of deposits in the liquifier could cause the heat pump to completely break down. For systems in which the heating water flow can be shut off via the radiator or thermostat valves, an overflow valve must be in- stalled in a heating bypass behind the heat pump by the cus- tomer. This ensures a minimum heating water flow rate through the heat pump and helps to avoid faults.

It is not necessary to open the device to establish the electrical connection.

The heat pump is connected to the power supply using the ap- prox. 5 m long preinstalled mains cable.

A disconnecting device with a contact gap of at least 3 mm (e.g. utility blocking contactor or power contactor) as well as a 1-pole circuit breaker must be installed in the heat pump power supply by the customer (tripping current in compliance with the Device Information).

Once the heating system has been installed, it must be filled, de- aerated and pressure-tested.

The control voltage is supplied via the control line and the heat pump controller.

Minimum heating water flow rate

The heat pump controller has a 230 V AC-50 Hz power supply. Connect the controller in compliance with its own operating in- structions (16 A fuse).

The minimum heating water flow rate through the heat pump must be assured in all operating states of the heating system. This can be accomplished, for example, by installing either a manifold without differential pressure or an overflow valve. The procedure for adjusting an overflow valve is described in the Chapter Start-Up.

The preinstalled, 7-m long control line is connected to the heat pump controller using both rectangular plug connectors and sin- gle-core wires (integral return flow sensor). The heat pump con- troller is a mandatory part of the control system. More detailed in- formation can be found in the operating instructions of the heat pump controller.

See Appendix Circuit Diagrams for detailed information.

Page 6 of the Dimplex LI 11MS user manual — Heat source temperature
Seite 6 · Zum Vergrößern klicken
Seite 6

7 Start-up

Any faults occurring during operation are also displayed on the heat pump controller and can be corrected as described in the operating instructions of the heat pump controller.

7.1 General Information

For external temperatures below 10 °C and heating water tem- peratures below 16 °C, the buffer tank should be heated up with the 2nd heat generator to at least 25 °C.

To ensure that start-up is performed correctly, it should only be carried out by an after-sales service technician authorized by the manufacturer. This may be a condition for extending the guaran- tee (see Warranty Service).

Observe the following procedure to implement a smooth start-up:

1. Close all of the heating circuits.
2. Fully open the overflow valve.

7.2 Preparation

3. Use the controller to select the automatic operating mode.
4. Wait until the buffer tank has reached a temperature of at least 25 °C.

The following items need to be checked prior to start-up:

„ All of the heat pump connections must be established as de-

5. Now slowly reopen the heating circuit valves in succession so that the heating water throughput is constantly raised by slightly opening the respective heating circuit. The heating water temperature in the buffer tank must not be allowed to drop below 20 °C during this process. This ensures that the heat pump can be defrosted at any time.

scribed in Chapter 6.

„ All valves that could impair the proper flow of the heating

water in the heating circuit must be open.

„ The air intake and air outlet paths must not be blocked in any

way.

„ The ventilator must turn in the direction indicated by the ar-

6. Set the minimum volume flow quantity on the overflow valve and heat circulating pump when all heating circuits are fully open and a heating water temperature in the buffer tank of approx. 20 °C is maintained.

row.

„ The settings of the heat pump controller must be adapted to

the heating system in accordance with the controller’s oper- ating instructions.

7. New buildings have an increased heat consumption on account of the energy required to dry them out. This increased heat consumption means that marginally dimensioned heating systems can not always achieve the desired room temperature. In such cases, we recommend keeping a 2nd heat generator on standby during the first heating period. The limit temperature on the heat pump controller should also be turned up to 15 °C.

„ The condensate outflow must not be impaired.

7.3 Procedure

The heat pump is started up via the heat pump controller. Adjust- ments should be made in compliance with the instructions.

If an overflow valve is fitted to maintain the minimum heating water flow rate, the valve must be adapted to the requirements of the heating system. Incorrect adjustment can lead to faulty oper- ation and increased energy consumption. We recommend carry- ing out the following procedure to correctly adjust the overflow valve:

8 Maintenance and Cleaning

Close all of the heating circuits that may also be closed during operation (depending on the type of heat pump usage) so that the most unfavourable operating state - with respect to the water flow rate - is achieved. This normally means the heating circuits of the rooms on the south and west sides of the building. At least one heating circuit must remain open (e.g. bathroom).

8.1 Maintenance

Avoid leaning or putting objects on the device in order to protect the paintwork. The external parts of the heat pump can be wiped with a damp cloth and domestic cleaner.

The overflow valve should be opened far enough to produce the maximum temperature spread between the heating flow and re- turn flow listed in the following table for the current heat source temperature. The temperature spread should be measured as close as possible to the heat pump. The heating element of mono energy systems should be disconnected.

To prevent faults due to sediment in the heat exchanger of the heat pump, ensure that the heat exchanger in the heating system can not be contaminated. We recommend protecting the evapo- rator by installing a bird guard in the inlet duct. At least 80 % of the cross section of the grating should be open. In the event that operating malfunctions due to contamination occur nevertheless, the system should be cleaned as described below.

Heat source temperature

Max. temperature spread between heating flow and return

flow From To

-20 °C -15 °C 4 K

-14 °C -10 °C 5 K

-9 °C -5 °C 6 K

-4 °C 0 °C 7 K

1 °C 5 °C 8 K

6 °C 10 °C 9 K

11 °C 15 °C 10 K

16 °C 20 °C 11 K

21 °C 25 °C 12 K

26 °C 30 °C 13 K

31 °C 35 °C 14 K

Page 7 of the Dimplex LI 11MS user manual — 8.3 Cleaning the Air System
Seite 7 · Zum Vergrößern klicken
Seite 7

9 Faults and Troubleshooting

8.2 Cleaning the Heating System

The ingress of oxygen into the heating water circuit may result in the formation of oxidation products (rust), particularly if steel components are used. These products enter the heating system via the valves, the circulating pumps and/or plastic pipes. It is therefore essential - in particular with respect to the piping of un- derfloor heating systems - that only diffusion-proof materials are used.

This heat pump is a quality product and is designed for trouble- free and maintenance-free operation. In the event that a fault should occur, it will be shown on the heat pump manager display. Simply consult the Faults and Trouble-shooting page in the oper- ating instructions of the heat pump manager. If you cannot cor- rect the fault yourself, please contact your after-sales service technician.

Residue from lubricants and sealants may also contaminate the heating water.

In the case of severe contamination leading to a reduction in the performance of the liquifier in the heat pump, the system must be cleaned by a heating technician.

10 Decommissioning/ Disposal

According to today's state of knowledge, we recommend using a 5 % phosphoric acid solution for cleaning purposes. However, if cleaning needs to be performed more frequently, a 5 % formic acid solution should be used.

Before removing the heat pump, disconnect it from the power source and close all valves. Observe all environmentally-relevant requirements regarding the recovery, recycling and disposal of materials and components in accordance with all applicable standards. Particular attention should be paid to the proper dis- posal of refrigerants and refrigeration oils.

In either case, the cleaning fluid should be at room temperature. We recommend flushing the heat exchanger in the direction op- posite to the normal flow direction.

To prevent acidic cleaning agents from entering the heating sys- tem circuit, we recommend connecting the flushing device di- rectly to the flow and return flow of the liquifier of the heat pump.

It is important that the system be thoroughly flushed using appro- priate neutralising agents to prevent any damage from being caused by cleaning agent residue remaining in the system.

Acids must be used with great care and all relevant regulations of the employers' liability insurance associations must be adhered to.

If in doubt, contact the manufacturer of the chemicals!

8.3 Cleaning the Air System

Air ducts, evaporator, ventilator and condensate outflow should be cleaned of contamination (leaves, twigs, etc.) before the heat- ing period. Do this by opening the front of the heat pump. The bottom should be opened first followed by the top.

Remove and rehang the side panel assemblies as described in Chapter 4.

Avoid using hard or sharp objects while cleaning to prevent the evaporator and the condensate tray from being damaged.

Page 8 of the Dimplex LI 11MS user manual — 7 Additional model features
Seite 8 · Zum Vergrößern klicken
Seite 8

11 Device Information

Device information for air-to-water heat pumps (heating only)

1 Type and order code LI 11MS

2 Design

2.1 Degree of protection according to EN 60 529 for compact devices and heating components IP21

2.2 Installation location Indoors

3 Performance data

3.1 Operating temperature limits:

Heating water flow/return flow 1 °C / °C

Up to 55 / above 18

Air °C -20 to +35

3.2 Temperature spread of heating water at A2 / W35 7.5

3.3 Heat output / COP at A-7 / W35 2 kW / ---

7.6 / 2.9

at A2 / W35 2 kW / --- 9.1 / 3.4

at A2 / W50 2 kW / --- 9.0 / 2.5

at A7 / W35 2 kW / --- 10.9 / 4.1

at A10 / W35 2 kW / --- 12.0 / 4.6

3.4 Sound power level device / outdoors dB(A) 55 / 61

3.5 Heating water flow with an internal pressure differential of m³/h / Pa 1.0 / 3000

3.6 Air flow rate with an external static pressure differential of m³/h / Pa 4200 / 0

m³/h / Pa 2500 / 25

3.7 Refrigerant; total filling weight type / kg R404A / 2.5

4 Dimensions, connections and weight

4.1 Device dimensions H x W x L cm 136 x 75 x 85

4.2 Device connections to heating system Inch G 1'' external

4.3 Air duct inlet and outlet (min. internal dimensions) L x W cm 50 x 50

4.4 Weight of the transportable unit(s) incl. packing kg 200

5 Electrical Connection

5.1 Nominal voltage; fuse protection V / A 230 / 25

5.2 Nominal power consumption 2 A2 W35 kW 2.65

5.3 Starting current with soft starter A 38

5.4 Nominal current A2 W35 / cosϕ A / --- 14.4 / 0.8

6 Complies with the European safety regulations 3

7 Additional model features

7.1 Defrosting Automatic

Type of defrosting Reverse cycle

Defrosting tray included Yes (heated)

7.2 Heating water in device protected against icing 4

7.3 Performance levels 1

7.4 Controller internal/external External

1. See operating limits diagram
2. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: External temperature 2 °C and heating water flow temperature 55 °C.
3. See CE declaration of conformity
4. The heat circulating pump and the heat pump controller must always be ready for operation.

Yes

Frage zu Dimplex LI 11MS stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Dimplex LI 11MS

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Dimplex LI 11MS PDF-Anleitung

44 Seiten·1.9 MB·Wärmepumpe·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…