UNVENTED (VENT -FREE) GAS COMP A CT CLASSIC HEARTH ® DU AL BURNER FIREPLA CE OWNER’S OPERA TION AND INST ALLA TION MANU AL Sav e this manual for future reference.
www .desatech.com 1 1 1244-01E 2 W ARNING: Improper installation, adjustment, altera- tion, service, or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer , service agency , or the gas supplier .
www .desatech.com 1 1 1244-01E 3 W ARNI NG: D o not allow fa ns to bl ow d ire ctl y into t he fire pla ce. Avo id any d raf ts that alter bu rner flam e pa tte rns . Ce ili ng f ans ca n cre ate dra fts th at a lte r b urne r flam e patt ern s. Alt ere d burn er pat ter ns c an cau se s oot ing .
www .desatech.com 1 1 1244-01E 4 PRODUCT IDENTIFICA TION Ignitor Button Screen Fireplace Cabinet Log Control Knob Figure 1 - V ent-Free Compact Dual Flame Fireplace O F F P I L O T O N H I L O Hood Fireplace Cabinet Logs Ignitor Button Remote Control (Optional) Control Knob Hood SAFETY INFORMA TION Continued 1.
www .desatech.com 1 1 1244-01E 5 OPTIONAL REMO TE CONTROL A CCESSORIES (For Remote-Ready Models Only) There are four optional remote controls that can be purchased separately for Remote-Ready Models only: • wall switch • hand-held ON/OFF remote • wall thermostat • ha nd -h el d th erm osta t r emo te See Accessories, page 44.
www .desatech.com 1 1 1244-01E 6 HOOD ASSEMBL Y WA R N I N G : A l wa y s h a v e screen in place before operat ing fireplace. This prevents exces- sive temperatures on fireplace surfaces.
www .desatech.com 1 1 1244-01E 7 PROVIDING ADEQUA TE VENTILA TION The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFP A 54, Section 5.3, Air for Combustion and V entilation. All spaces in homes fall into one of the three fol - lowing ventilation classifications: 1.
www .desatech.com 1 1 1244-01E 8 AIR FOR COMB USTION AND VENTILA TION Continued 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
www .desatech.com 1 1 1244-01E 9 CAUT ION: This firep lace c re- ates warm air currents. These currents move heat to wall sur- faces next to fir eplace.
www .desatech.com 1 1 1244-01E 10 INST ALLA TION ITEMS Before installing fireplace, make sure you have the items listed below . • external regulator (supplied by installer, for propane/LP units onl.
www .desatech.com 1 1 1244-01E 1 1 INST ALLA TION Continued Figure 9 - Rough Opening for Installing in Corner Figure 8 - Rough Opening for Installing in Wall 43 5 / 16 " 30 5 / 8 " 61 1 / 4 .
www .desatech.com 1 1 1244-01E 12 15" 18" 21" 23" 2 1 / 2 " 6" 8" 10" Note: A ll vertical measurements are from top of fireplace opening to bottom of mantel shelf.
www .desatech.com 1 1 1244-01E 13 INST ALLA TION Continued 9. Use two 3" wood screws provided and attach base of fireplace to wooden mantel base (see Figure 13). 10. Remove perimeter trim kit and mantel. Be careful not to damage wall or mantel. 1 1.
www .desatech.com 1 1 1244-01E 14 INST ALLA TION Continued Installing Blower Accessory CAUTION: Label all wires prior to disconnection when serv icin g c ontro ls. Wiri ng e rror s can ca use imp roper a nd dang er - ous operation. CAUTION: V erify proper op- eration after servicing.
www .desatech.com 1 1 1244-01E 15 INST ALLA TION Continued For Built-In Installation W ARNING: A licensed elec- trician must connect the wiring harness to electrical supply followi ng all local codes . Elect ri- cian mus t p rovid e a clamp on th e box cover to secure the wiring.
www .desatech.com 1 1 1244-01E 16 Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 21). IMPORT ANT : Install equipment shutoff valve in an accessible location.
www .desatech.com 1 1 1244-01E 17 INST ALLA TION Continued W e recommend that you install a sediment trap in supply line as shown in Figure 21, page 16. Locate sedime nt trap where it is within reach for cleaning. Install in piping system between fuel supply and heater .
www .desatech.com 1 1 1244-01E 18 INST ALLA TION Continued CAUTION: Make sure exter- nal regulator has been installed betwe en pro pane/LP supply and fireplace. See guidelines under Connecting to Gas Supply , page 16. PR ES SU RE T ES TIN G GA S S UPP LY P IPIN G SY ST EM T est Pressures In Excess Of 1/2 PSIG (3.
www .desatech.com 1 1 1244-01E 19 OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL ACCESSORIES Remote-Ready Models Only ([C]GHRCB Series & [C]GHRCTB Series) Installing Receiver 1. Disconnect wires from the control valve (see Figure 27) . 2. Locate the battery clip mounted on the back of the receiver (see Figure 28).
www .desatech.com 1 1 1244-01E 20 INST ALLA TION Continued 2. Connect one terminal of 25 ft. wire to the “TH” terminal on the control valve. Connect the other terminal to the “THTP” terminal on the control valve. See Figure 32. 3. Route the 25 ft.
www .desatech.com 1 1 1244-01E 21 IMPORT ANT : The wire may be shortened but must not be lengthened. 4. Connect one bare wire end to each of the terminals of the provided wall switch. 5. Install the wall switch and cover in the wall. INST ALLING LOG SET AND SCREEN (Models with One-Piece Screen Only) 1.
www .desatech.com 1 1 1244-01E 22 LIGHTING INSTRUCTIONS W ARNI NG: Y ou must o pera te this fireplace with the screen in place . Make sure firepla ce screen is installed before run- ning fireplace. NOTICE: Durin g initial op era- tion of new fireplace, burning logs will give off a paper-burn- ing smell.
www .desatech.com 1 1 1244-01E 23 Figure 40 - Control Knob In The OFF Position Ignitor Button Control Knob 6. With control kn ob pressed in, p r ess a nd release ignitor button. This will light pilot. The pilot is attached to the fr ont burner . If needed, keep pressing ignitor button until pilot lights.
www .desatech.com 1 1 1244-01E 24 OPERA TING FIREPLACE Continued Note: It is safe to operate fireplace with blower tur ned off. Howe ver , the blower hel ps distri bute heated air fr om the fireplace.
www .desatech.com 1 1 1244-01E 25 OPERA TING FIREPLACE Continued 6. With control kn ob pressed in, p r ess a nd release ignitor button. This will light pilot. The pilot is attached to the fr ont burner . If needed, keep pressing ignitor button until pilot lights.
www .desatech.com 1 1 1244-01E 26 REMOTE OFF ON H I LO IN OUT OPERA TING FIREPLACE Continued Note: The burner may light if hand-held remote was on when selector switch was last turned off. Y ou can now turn the burner on and off with the hand-held remote contr ol unit.
www .desatech.com 1 1 1244-01E 27 OPERA TING FIREPLACE Continued 2. The receiver continuously receives signals from the hand-held remote to control the roo m tempera ture . If the hand-he ld rem ote is misplaced, obstructed, or for any reason cannot transmit to the rece iver , the receiv er will shut off the fireplace after 8 minutes.
www .desatech.com 1 1 1244-01E 28 BURNER FLAME P A TTERN Figure 53 shows a correct burner flame pattern. Figure 54 shows an incorrect burner flame pattern. The incorr ect burner flame pattern shows sporad ic, irregular flame tipping. The flame should not be dark or have an orange/reddish tinge.
www .desatech.com 1 1 1244-01E 29 Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot as - sembly . There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figures 56 or 57 depend- ing on model).
www .desatech.com 1 1 1244-01E 30 TROUBLESHOO TING WA RNI NG : T ur n of f and un pl ug fir ep la ce an d let c oo l b ef or e s er v ic in g . On ly a qua lifi ed se rvi ce pe r so n s ho ul d s er vic e and re pa ir fire pl ace . CA UTI ON : N ev er us e a w ire , nee dl e, or si mi lar ob je ct to cl ea n O DS / pi lot .
www .desatech.com 1 1 1244-01E 31 POSSIBLE CAUSE 1 . Control knob not fully pressed in 2. Control knob not pressed in long enough 3. Safety interlock system has been triggered 4. Equipment shutoff valve not fully open 5. Pilot flame not touching ther - mocouple, which allows ther - mocouple to cool, causing pilot flame to go out.
www .desatech.com 1 1 1244-01E 32 TROUBLESHOO TING Continued POSSIBLE CAUSE 1. Residues from manufacturing processes and log curing 2. Not enough air 3. Gas regulator defective 1. Turning control knob to HI position when burner is cold 2. Air in gas line 3.
www .desatech.com 1 1 1244-01E 33 TROUBLESHOO TING Continued W ARN IN G: If yo u s mel l gas • S hu t off g as sup pl y. • D o no t t ry to li gh t a ny ap pli anc e. • Do not to uch any ele ct ric al sw it ch ; do not us e an y ph on e in you r bu ild in g.
www .desatech.com 1 1 1244-01E 34 SPECIFICA TIONS Thermostat Models: CDCFTP A, VDCFTP , FDCFTP CDCFTNA, VDCFTN, FDCFTN Btu/Hr 17/26,000 17/26,000 T ype Gas Propane/LP Gas Only Natural Gas Only Ignition Piezo Piezo Manifold Pressure 8" W .C. 3.5" W .
www .desatech.com 1 1 1244-01E 35 SERVICE HINTS When Gas Pressure Is T oo Low • pilot will not stay lit • burners will have delayed ignition • fireplace will not produce specified heat • for propane/LP units, propane/LP gas supply may be low Yo u may feel you r gas pres sure is too low.
www .desatech.com 1 1 1244-01E 36 8 8 19 19 19 19 19 19 19 1 9 9 10 10 10 16 17 10 10 14 6 3 1 1 12 13 1 1 15 16 18 16 16 16 16 16 16 2 5 16 16 16 16 7 4 ILL USTRA TED P ARTS BREAKDOWN FIREBOX MODELS .
www .desatech.com 1 1 1244-01E 37 KEY P ART NUMBERS NO. FDCF Models VDCF Models CDCF Models DESCRIPTION QTY . 1 ** ** ** Outer Casing T op 1 2 ** ** ** Baffle 1 3 ** ** ** Outer Casing 1 4 104281-02B.
www .desatech.com 1 1 1244-01E 38 ILL USTRA TED P ARTS BREAKDOWN FIREBOX MODELS CDCFNR, CDCFPR 8 10 8 14 14 14 14 14 14 14 1 9 9 10 10 20 19 22 10 16 17 10 10 6 3 1 1 12 13 23 21 24 1 1 15 16 18 16 16.
www .desatech.com 1 1 1244-01E 39 KEY NO. P ART NUMBER DESCRIPTION QTY . 1 ** Outer Casing T op 1 2 ** Baffle 1 3 ** Outer Casing 1 4 104281-02BR Firebox Hood 1 5 ** Firebox T op 1 6 ** Firebox Wrapper 1 7 1 10339-01CK Outer Base 1 8 102635-02 Front Left and Right Sides 2 9 103209-05 Extruded Louver 2 10 098304-01 Screw , PPH AB 10-16 x .
www .desatech.com 1 1 1244-01E 40 ILL USTRA TED P ARTS BREAKDOWN THERMOST A T MODELS FDCFTP , FDCFTN, VDCFTP , VDCFTN, CDCFTP A AND CDCFTNA 8 7 5 6 6 12 2 4 19 18 15 16 9 9 17 1 1 14 3 13 20 9 1 21 10.
www .desatech.com 1 1 1244-01E 41 P ARTS LIST THERMOST A T MODELS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 35 of this manual. KEY FDCFTP FDCFTN NO.
www .desatech.com 1 1 1244-01E 42 ILL USTRA TED P ARTS BREAKDOWN REMOTE-READY MODELS FDCFRN, FDCFRP , VDCFRN, VDCFRP , CDCFNR, CDCFPR O F F P I L O T O N H I L O 16 15 15 16 12 12 1 1 9 9 9 10 5 17 18.
www .desatech.com 1 1 1244-01E 43 CDCFPR CDCFNR KEY FDCFRP FDCFRN NO. VDCFRP VDCFRN DESCRIPTION QTY . 1 1 1 1069-01 1 1 1069-01 Dual Burner 1 2 099056-29 099056-34 Injector 1 3 103342-04 1 1 1 195-07 .
www .desatech.com 1 1 1244-01E 44 ACCESSORIES NOTICE: All accessories may not be available for all fireplace models. Pu rch as e the se fire pl ac e acc ess or ie s fro m your loca l dea ler. If they can not supply thes e acce sso ries , cal l DESA Heating Pro duct s at 1-8 66-67 2-60 40 for re - fe rra l info rm ati on .
www .desatech.com 1 1 1244-01E 45 CORNER MANTEL WITH FULL HEARTH BASE CMA208F Series - Dark Oak CMA209U Series - Unfinished Birch For all models. Space-saving mantel and hearth base corner design features clean, classic lines. A vailable in french walnut finish or an unfinished hardwood, ready to stain or paint.
www .desatech.com 1 1 1244-01E 46 NO TES _____________________________________________________ _____________________________________________________ ___________________________________________________.
www .desatech.com 1 1 1244-01E 47 NO TES _____________________________________________________ _____________________________________________________ ___________________________________________________.
2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com 1 1 1244-01 Rev . E 08/04 NOT A UPC 111244 01.
Ein wichtiger Punkt beim Kauf des Geräts Desa DCFTNA (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Desa DCFTNA noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Desa DCFTNA - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Desa DCFTNA reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Desa DCFTNA erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Desa DCFTNA besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Desa DCFTNA verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Desa DCFTNA. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Desa DCFTNA gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.