Benutzeranleitung / Produktwartung (V)KC42PE des Produzenten Desa
Zur Seite of 40
For more information, visit www .desatech.com W ARNING: If the information in this manual is not fol- .
www .desatech.com 1 16240-01E 2 SAFETY INFORMA TION T ABLE OF CONTENTS Safety Information ............................................... 2 Product Identication ........................................... 4 Local Codes..............................
www .desatech.com 1 16240-01E 3 This replace must be installed by a qualied (cer - tied or licensed) service person. It has a sealed gas combustion chamber that uses a coaxial pipe (pipe within a pipe and having the same center) venting system.
www .desatech.com 1 16240-01E 4 2. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrica l switch; do not use any phone in your building • immediately call your gas supplier from a neighbor ’ s phone.
www .desatech.com 1 16240-01E 5 PRODUCT FEA TURES These are a few facts that can help you understand and enjoy your direct-vent replace: • The venting system may be routed to the out - side of your home in several ways. It may vent through the roof (vertical) or it may vent to an outside/exterior wall (horizontal).
www .desatech.com 1 16240-01E 6 • Y our replace is designed to be used in zero clea ranc e install atio ns. W all or fram ing mater ial can be placed directly against any exterior sur - face on the back, sides or top of your replace, except where standoff spacers are integrally atta ched .
www .desatech.com 1 16240-01E 7 A B E F G H D C Nailing T abs Figure 4 - Framing Clearances for Installation Against an Exterior Wall 40 1 / 8 " 48 1 / 4 " 23" Horizontal V ent 26 1 / 2.
www .desatech.com 1 16240-01E 8 Figure 7 - Minimum Clearances for T ermination Cap LOCA TION OF TERMINA TION CAP Fixed Closed Op en ab le Fixed Closed V V V V V V V V X X V X G G J F B B K N H I A N E.
www .desatech.com 1 16240-01E 9 VENT ING INST ALLA TION INSTRUCTIONS NOTICE: Read these instruc- .
www .desatech.com 1 16240-01E 10 INST ALLA TION PLANNING There are two basic types of direct-vent in - stallation: • Horizontal T ermination • V ertical T ermination Horizontal T ermination Installation IMPORTANT : Horizontal square terminations require only inner portion of wall restop.
www .desatech.com 1 16240-01E 1 1 VENTING INST ALLA TION INSTRUCTIONS Continued W ARNING: Do not recess 6.
www .desatech.com 1 16240-01E 12 VENTING INST ALLA TION INSTRUCTIONS Continued Figure 13 - T ypical Horizontal T ermination Cap Mounting with Additional Siding Standoff Installed Siding Standoff Screw.
www .desatech.com 1 16240-01E 13 CORNER INST ALLA TION Recommended Applications: • Corner ground oor installation • G ro un d o or in st a ll at io n w he re pi p e ve nt s ho ri zo n - ta .
www .desatech.com 1 16240-01E 14 VENTING INST ALLA TION INSTRUCTIONS Continued Horizontal (H 1 Horizontal (H 1 Horizontal (H 2 5' min.
www .desatech.com 1 16240-01E 15 INST ALLA TION FOR VERTICAL TERMINA TION Note: V ertical restrictor must be installed in all vertical installations. 1.
www .desatech.com 1 16240-01E 16 5. Pla ce th e as hing ov er th e pip e sec tion( s) extendin g through the roof. Secure the base of the ashing to the roof and framing with roof - ing nails. Be sure roo ng materia l over laps the top edge of the ashing as shown in Figure 19, page 15.
www .desatech.com 1 16240-01E 17 VENTING INST ALLA TION INSTRUCTIONS Continued Note : Install restrictor into inner collar of replace as shown. V ertical (V 1 5' min.
www .desatech.com 1 16240-01E 18 AND COMPONENTS .
www .desatech.com 1 16240-01E 19 FIREPLACE INST ALLA TION Us e pro per ga s typ e for the r ep la ce un it yo u are in st al li ng . If you hav e co n ic ti ng gas typ es , do not in st al l re plac e.
www .desatech.com 1 16240-01E 20 CA UTI ON: Nev er to uc h th e 9. Ch ec k to mak e sure th at the pow er cor d is com - pl et el y cl ea r of t he b lo we r wh ee l an d t hat t he re ar e no oth er for ei gn obj ect s in bl ow er whe el.
www .desatech.com 1 16240-01E 21 7. Che ck to ma ke su re t ha t th e po we r co rd is c om - pl ete ly c lea r of th e b low er w he el a nd t ha t th ere a re no ot he r f or ei gn o bj ec ts i n b lo we r wh ee l .
www .desatech.com 1 16240-01E 22 Figure 30 - External Regulator with V ent Pointing Down (Propane/LP Only) Propane/LP Supply T ank External Regulator V ent Pointing Down CAUTION: Use only new , .
www .desatech.com 1 16240-01E 23 FIREPLACE INST ALLA TION Continued .
www .desatech.com 1 16240-01E 24 PRESSURE TESTING FIREPLACE GAS CONNECTIONS 1. Open equipment shutof f valve (see Figure 33, page 23). 2. O pe n p ro p a ne / L P s u p pl y t an k v al v e f o r propane/LP fireplace or main gas valve located on or near gas meter for natural gas replace.
www .desatech.com 1 16240-01E 25 4. Remount the new frame at the hinge with ve new s crew s bef ore c losin g do or . Th is wi ll ensure seating of the gasket. 5. Cl os e g la ss d oo r fr am e. L oc k l at che s by p la ci ng th e ba r u nd er t he ta b on do or a nd p us hi ng do wn an d bac k on la t ch ( se e Fi gu re 37, p age 24).
www .desatech.com 1 16240-01E 26 7. Remove three screws from deector shield on the inside top of rebox. Set shield and screws aside. 8. Install rear brick panel rst. Rest bottom edge of panel on back edge of burner assembly (see Figure 39). 9.
www .desatech.com 1 16240-01E 27 EV2 EV1 ORANGE IGNITOR LEAD GREEN PILOT TRANSFORMER IS1070B SYNETEK CONTROLS INC 24V AC E4 E2 E3 E6 RED E8 E12 BLUE 120V AC GROUND BLACK WHITE WIRING DIAGRAM.
www .desatech.com 1 16240-01E 28 6. W ait ve (5)minutes toclear outany gas. Then smell for gas, including near the oor . Ifyousmell gas,STOP!Follow“B”inthe safet y inform ation in column 1.
www .desatech.com 1 16240-01E 29 Figure 45 - T ypical Flame Pattern OPTIONAL REMOTE OPERA TION Not e: The WRC receiver and hand-held r e - motecontr olkitmust bepurchased separately (see Accessories , page 35).
www .desatech.com 1 16240-01E 30 C L E A N IN G AN D M A I N T EN AN C E .
www .desatech.com 1 16240-01E 31 VENTING SYSTEM Conduct annual inspection of the venting system following these guidelines: 1. Ch ec k are as of ve nt in g sys tem th at ar e ex po se d to th e we at her fo r co rro si on (r ust spo ts or st re ak s an d, i n extr eme c as es , ho le s) .
www .desatech.com 1 16240-01E 32 Pilot will not stay lit No gas to burner , although wall switch and valve are set to the ON position Frequent pilot outage Fir epla ce produ ces a clicki ng/t ick - ing noise just after burner is lit or shut off Slight smoke or odor during initial operation REMEDY 1 .
www .desatech.com 1 16240-01E 33 TROUBLESHOO TING Continued .
www .desatech.com 1 16240-01E 34 REPLACEMENT P ARTS Note : Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty .
www .desatech.com 1 16240-01E 35 - Black - Brushed Brass - Platinu.
www .desatech.com 1 16240-01E 36 ILL USTRA TED P ARTS BREAKDOWN .
www .desatech.com 1 16240-01E 37 P ARTS LIST This list contains replaceable parts used in your replace.
www .desatech.com 1 16240-01E 38 ILL USTRA TED P ARTS BREAKDOWN .
www .desatech.com 1 16240-01E 39 P ARTS LIST This list contains replaceable parts used in your replace.
2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com NOT A UPC 1 16240-01 Rev . E 03/06 WARRANTY INFORMA TION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory .
Ein wichtiger Punkt beim Kauf des Geräts Desa (V)KC42PE (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Desa (V)KC42PE noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Desa (V)KC42PE - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Desa (V)KC42PE reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Desa (V)KC42PE erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Desa (V)KC42PE besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Desa (V)KC42PE verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Desa (V)KC42PE. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Desa (V)KC42PE gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.