
OWNERS MANUAL FOR
CRAFTSMAN TANK MOUNTED AIR COMPRESSOR
Model No. 919.728000
Record in the spaces provided. (1) The Model Number can be found on the maintenance label on top of the motor shroud or on the bar code label on the rear of air tank. (2) The Date Code Number can be found on the bar code label on the rear of the air tank. (3) The Serial Number can be found on the bar code label on the rear of the tank. (4) The Tank Registration Number is located on the metal data plate which is welded onto the backside of the air tank. (This data plate is painted the same color as the tank.)
Retain these numbers for future reference.
IMPORTANT: Read the Safety Guidelines and All Instructions Carefully Before Operating
Sold by Sears Canada, Inc., Toronto, Ont. M5B 2B8
D21245 Rev. 4 7/18/01


IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT.
IT IS NORMAL FOR ELECTRICAL CONTACTS WITHIN THE MOTOR AND PRESSURE SWITCH TO SPARK.
ALWAYS OPERATE THE COMPRESSOR IN A WELL VENTI- LATED AREA FREE OF COMBUSTIBLE MATERIALS, GASOLINE OR SOLVENT VAPORS.
IF SPRAYING FLAMMABLE MATERIALS, LOCATE COMPRES- SOR AT LEAST 20 FEET AWAY FROM SPRAY AREA. AN ADDITIONAL LENGTH OF HOSE MAY BE REQUIRED.
IF ELECTRICAL SPARKS FROM COMPRESSOR COME INTO CONTACT WITH FLAMMABLE VAPORS, THEY MAY IGNITE, CAUSING FIRE OR EXPLOSION.
STORE FLAMMABLE MATERIALS IN A SECURE LOCATION AWAY FROM COMPRESSOR.
RESTRICTING ANY OF THE COMPRESSOR VENTILATION OPENINGS WILL CAUSE SERIOUS OVERHEATING AND COULD CAUSE FIRE.
NEVER PLACE OBJECTS AGAINST OR ON TOP OF COM- PRESSOR. OPERATE COMPRESSOR IN AN OPEN AREA AT LEAST 12 INCHES AWAY FROM ANY WALL OR OBSTRUC- TION THAT WOULD RESTRICT THE FLOW OF FRESH AIR TO THE VENTILATION OPENINGS.
OPERATE COMPRESSOR IN A CLEAN, DRY, WELL VENTI- LATED AREA. DO NOT OPERATE UNIT INDOORS OR IN ANY CONFINED AREA.
UNATTENDED OPERATION OF THIS PRODUCT COULD RESULT IN PERSONAL INJURY OR PROPERTY DAMAGE.
ALWAYS REMAIN IN ATTENDANCE WITH THE PRODUCT WHEN IT IS OPERATING.


MOVING PARTS SUCH AS THE PULLEY, FLYWHEEL AND BELT CAN CAUSE SERIOUS INJURY IF THEY COME INTO CONTACT WITH YOU OR YOUR CLOTHING.
NEVER OPERATE THE COMPRESSOR WITH GUARDS OR COVERS WHICH ARE DAMAGED OR REMOVED.
ATTEMPTING TO OPERATE COMPRESSOR WITH DAMAGED OR MISSING PARTS OR ATTEMPTING TO REPAIR COM- PRESSOR WITH PROTECTIVE SHROUDS REMOVED CAN EXPOSE YOU TO MOVING PARTS AND CAN RESULT IN SERIOUS INJURY.
ANY REPAIRS REQUIRED ON THIS PRODUCT SHOULD BE PERFORMED BY AUTHORIZED SERVICE CENTER PERSON- NEL.

You have purchased an air compressor unit consisting of an aluminum 2 cylinder, single-stage air compressor pump (with cast iron sleeves), an air tank, wheels, handle, associated controls and instruments.
An air line filter is usually required for removal of moisture and oil vapor in compressed air when a paint spray gun is used.
An in-line lubricator is usually required for air tools to prolong tool life.
Your air compressor can be used for operating paint spray guns, air tools, caulking guns, grease guns, air brushes, sandblasters, inflating tires and plastic toys, spraying weed killers, insecticides, etc. An air pres- sure regulator is required for most of these applica- tions.
Separate air transformers which combine the functions of air regulation and/or moisture and dirt removal should be used where applicable.
CFM: Cubic Feet per Minute.
Cut-Out Pressure: When you turn on your air com- pressor and it begins to run, air pressure in the air tank begins to build. It builds to a certain high pressure before the motor automatically shuts off - protecting your air tank from pressure higher than its capacity. The high pressure at which the motor shuts off is called “cut-out pressure.”
SCFM: Standard Cubic Feet per Minute; a unit of measure of air delivery.
PSI: Pounds per Square Inch; a unit of measure of pressure.
ASME: American Society of Mechanical Engineers; made, tested, inspected and registered to meet the standards of the ASME.
CSA: Electrical products sold in Canada are required to be certified to the applicable CSA standard (s). Canadian Standards Association (CSA) is a standards writing and safety testing organization. Products that are CSA certified have been evaluated and tested and found to meet or exceed the applicable CSA standard (s) for safety and electrical performance.
Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accessory. When the tank pressure drops to a certain low level and the pressure switch lever is in "Auto", the motor will restart automatically. The low pressure at which the motor automatically restarts is called “cut-in pressure.”
Model No.
919.728000 2 3/8" 1.35" 120/240 15 amps Time Delay
Bore Stroke Voltage - Single Phase Minimum Branch Circuit Requirement Fuse Type Amperage at Maximum Pressure Air Tank/Capacity Approximate Cut-in Pressure Approximate Cut-out Pressure SCFM @ 40 psi SCFM @ 90 psi
15.0 ASME/30 gal. (U.S.)
100 125 7.2 5.6

Air Compressor Pump: To compress air, the piston moves up and down in the cylinder. On the downstroke, air is drawn in through the air intake valves. The exhaust valves remain closed. On the upstroke of the piston, air is compressed. The intake valves close and compressed air is forced out through the exhaust valves, through the outlet tube, through the check valve and into the air tank.
Regulator: The air pressure coming from the air tank is controlled by the regulator. The regulator control knob is a vibration proof design. Lift the regulator knob to en- gage and depress the knob to lock. Turn the regulator knob clockwise to increase pressure and counter-clock- wise to decrease pressure. To avoid minor readjustment after making a change in pressure setting, always ap- proach the desired pressure from a lower pressure. When reducing from a higher to a lower setting, first reduce to some pressure less than that desired, then bring up to the desired pressure. Depending on the air requirements of each particular accessory, the outlet regulated air pres- sure may have to be adjusted while operating the acces- sory.
Check Valve: When the air compressor is operating, the check valve is “open”, allowing compressed air to enter the air tank. When the air compressor reaches “cut-out” pressure, the check valve “closes”, allowing air pres- sure to remain inside the air tank.
Pressure Switch: The pressure switch is fitted with a small lever. It is labeled "Auto/O" for automatic run or off. In the "O" position, the motor will not run. In the "Auto" position, it automatically starts the motor when the air tank pressure drops below the factory set “cut-in” pres- sure. It stops the motor when the air tank pressure reaches the factory set “cut-out” pressure.
Regulator Gauge: The outlet pressure gauge indicates the air pressure available at the outlet side of the regula- tor. This pressure is controlled by the regulator and is always less than or equal to the tank pressure. See “Op- erating Procedures”.
Tank Pressure Gauge: The tank pressure gauge indi- cates the reserve air pressure in the tank.
Pressure Release Valve: The pressure release valve lo- cated on the side of the pressure switch is designed to automatically release compressed air trapped within the compressor head and outlet tube. This short release of air will occur when the air compressor reaches "cut-out" pressure or the unit is shut off. If the air is not released, the motor will not be able to start when next required.
Air Intake Filter: This filter is designed to clean air coming into the pump. This filter must always be clean and ventila- tion openings free from obstructions. See "Maintenance".
Drain Valve: This valve is located at the bottom of the tank. To drain accumulated moisture from the tank, pull on the safety valve until tank pressure is 15 PSI. Un- screw the drain valve and allow the water to drain.
Flow Valve: The flow valve allows air to flow from the head as the motor is getting “up to speed”. Once the motor reaches normal operating speed, the flow valve closes and the pump begins to compress air, thus re- quiring less amp draw on initial start.
Safety Valve: If the pressure switch does not shut off the air compressor at its cut-out pressure setting, the safety valve will protect the tank against high pressure by “pop- ping out” at its factory set pressure (slightly higher than the pressure switch cut-out setting).

It may be necessary to brace or support one end of the outfit when attaching the wheels because the air compressor will have a tendency to tip.
A. Are both tabs inside the handle (Step #1)?
B. Does each clip pass through both the saddle and handle (Step #2)?
2. The leg bracket on the underside of the air compres- sor tank has 2 holes on each side for mounting the wheels. Place one shoulder bolt through the hole in a wheel. On models with 10" wheels, push the bolt through the TOP hole of the leg bracket. For models with 8" wheels, push the bolt through the BOTTOM hole of the leg bracket. Screw on one hex locking nut. The special locking nut does not turn freely. Tighten the nut firmly until it contacts the tank leg. The outfit will sit level if the wheels are properly installed.


The side of the wheel, that the hub protrudes out past the wheel edge, should be bolted to the compressor leg.
FIG. 1


THE WHEELS AND HANDLE DO NOT PRO- VIDE ADEQUATE CLEARANCE, STABILITY OR SUPPORT FOR PULLING THE UNIT UP AND DOWN STAIRS OR STEPS. THE UNIT MUST BE LIFTED OR PUSHED UP A RAMP. DO NOT LIFT THE UNIT BY THE MANIFOLD ASSEMBLY. THE UNIT CAN BE DAMAGED.
FIG. 4
1. Insert the open end of the handle under the saddle (Fig. 1). Before attaching handle, you may have to pull the open ends of the handle apart so they fit tightly against the side of the saddle. Looking in from the open end of the saddle, position the handle toward the two bent tabs, on the inside walls of the saddle. Slowly push the open ends of the handle onto both tabs at the same time (Fig. 2). Continue pushing the handle into the saddle until the holes on the side of the saddle and handle are in line.
Installing Handle

been installed and grounded in accordance with all local codes and ordinances. The outlet must have the same configuration as the plug. DO NOT USE AN ADAPTER.
Operate the air compressor in a clean, dry and well ventilated area. The fan bladed flywheel must be kept clear of obstructions that could interfere with the flow of air through the air intake filter. The pump crankcase and head are designed with fins to provide proper cooling.
Inspect the plug and cord before each use. Do not use if there are signs of damage.
If humidity is high, an air filter can be installed on the air outlet adapter to remove excessive moisture. Closely follow the instructions packaged with the filter for proper installation. It must be installed as close as possible to the accessory.Do not place the air compressor where heat is excessive.
IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK.
Do not modify the plug that has been provided. If it does not fit the available outlet, the correct outlet should be installed by a qualified technician.
When locating the compressor outside, make sure there is a mimum of 12 inches on each side of the compres- sor. There must be fresh air flow for proper cooling. DO NOT ALLOW THE COMPRESSOR TO GET WET.
If repairing or replacing cord or plug, the grounding wire must be kept separate from the current-carrying wires. Never connect the grounding wire to a flat blade plug terminal. The grounding wire has insulation with an outer surface that is green with or without yellow stripes.
If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.
Compressors are shipped without oil. Do not attempt to operate this air compressor without first adding oil to the crankcase. Serious damage can result from even limited operation unless filled with oil and broken in correctly. Make sure to closely follow initial start-up procedures.

Place unit on a level surface. Remove oil fill plug and slowly add a special compressor oil such as Sears 9-16426 or SAE 20-20W SF motor oil until it is even with the top of the oil fill hole. (It must not be allowed to be lower than 3/8" -- 6 threads down -- from the top at any time.) When filling the crankcase, the oil flows very slowly. If the oil is added too quickly, it will overflow and appear to be full. Crankcase oil capacity is 16 fluid ounces. Under winter-type conditions use SAE 10W oil. Multi-viscosity oil, 10W 30, will leave carbon deposits on critical components, reducing perfor- mance and compressor life. Replace oil fill plug.
Refer to your Specification Chart (page 6) for voltage and circuit protection requirements of your compressor. Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on. If the compressor is connected to a circuit protected by fuses, use only dual element time delay fuses.
RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded.
This portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be used with an outlet that has

can gather and freeze. Apply pressure before under- ground lines are covered to make sure all pipe joints are free of leaks.
Certain air compressors can be converted from 120V to 240V operation. When converting an air compressor to 240V operation, the attached three-prong 120V cord assembly must be replaced with a three-pronged 240V cord assembly that can be purchased through a Sears Service Center. Some models have a dual voltage motor, 120 and 240 volt. They are wired for 120 volt but can be converted to 240 volt operation. Instructions for connecting the motor for operation at 240 volt can be found printed on the label attached to the side of the motor.
Connect the piping to the 3/8" NPT air outlet opening at the end of the air tank.
Since the air tank pressure is usually greater than that which is needed, a separate regulator is employed to control the air pressure ahead of any individual air driven device.
Separate air transformers which combine the function of air regulation, moisture and dirt removal should be used where applicable.
Certain air compressor models can be operated on a 15 amp circuit if:
Serious damage may result if the following break-in instructions are not closely fol- lowed. This procedure is required only once, before the air com- pressor is put into service.
Extension Cords To avoid voltage drop and power loss to the motor, and to prevent overheating, use extra air hose instead of an extension cord.
1. Set the pressure switch "AUTO/O" lever in the "O" position for "Off". 2. Plug the power cord into the correct branch circuit receptacle. 3. Do not attach hose to outlet. Leave the outlet open to the atmosphere. 4. Turn the regulator clockwise, opening it fully, to prevent air pressure build-up in the tank. 5. Move the "AUTO/O" lever to "AUTO". The com- pressor will start. 6. RUN THE COMPRESSOR FOR 30 MINUTES. Make sure the regulator is open and there is no tank pressure build-up. 7. After 30 minutes, close the regulator by turning it counterclockwise. The air tank will fill to cut-out pressure and then the motor will stop.
If an extension cord must be used:
Plastic or PVC pipe is not designed for use with compressed air. Regardless of its indicated pressure rating, plastic pipe can burst from air pressure. Use only metal pipe for air distribution lines.
If a pipe line is necessary, use pipe that is the same size as the air tank outlet. Piping that is too small will restrict the flow of air. If piping is over 100 feet long, use the next larger size. Bury underground lines below the frost line and avoid pockets where condensation

WHEN YOU ARE FINISHED: 12. Set the “AUTO/O” lever to “O”.
TOO MUCH AIR PRESSURE CREATES A HAZARDOUS RISK OF BURSTING. CARE- FULLY FOLLOW STEPS 3 AND 5 BELOW EACH TIME THE COMPRESSOR IS USED.
WATER WILL CONDENSE IN THE AIR TANK. IF NOT DRAINED, WATER WILL CORRODE AND WEAKEN THE AIR TANK CAUSING A RISK OF AIR TANK RUPTURE.
Compressed air from the outfit may contain water condensation. Do not spray unfiltered air at an item that could be damaged. Some air operated tools or devices may require filtered air. Read the instructions for the air tool or device.
If drain cock valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.

UNIT CYCLES AUTOMATICALLY WHEN POWER IS ON. WHEN DOING MAINTENANCE, YOU MAY BE EXPOSED TO VOLTAGE SOURCES, COMPRESSED AIR OR MOVING PARTS. PERSONAL INJURIES CAN OCCUR. BEFORE PERFORMING ANY MAINTENANCE OR REPAIR, UNPLUG THE COMPRESSOR AND BLEED OFF ALL AIR PRES- SURE.
ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE DONE BY A QUALIFIED SERVICE TECHNICIAN.
the old filter. Push in the new air filter. Other models require removal of the belt guard and/or filter retainer. Check Valve Cleaning - Replacement
Daily:
Every 40 Hours of Operation:
1. Release all air pressure from air tank and unplug outfit. 2. Remove shroud. 3. Loosen the top and bottom nuts and remove the outlet tube. 4. Remove the pressure release tube, fitting, and connector. 5. Unscrew the check valve (turn counterclockwise) using a socket wrench. 6. Check that the valve disc moves freely inside the check valve and that the spring holds the disc in the upper, closed position. The check valve may be cleaned with a solvent, such as paint and varnish remover. 7. Apply a Teflon based pipe sealant to the check valve threads. Reinstall the check valve (turn clockwise). 8. Replace the pressure release tube and fitting. 9. Replace the outlet tube and tighten top and bottom nuts. 10. Replace the shroud.
Every 100 Hours of Operation:
Every 160 Hours of Operation:
Each Year of Operation or if a Problem
is Suspected:
Check condition of air compressor pump intake and exhaust valves. Replace if damaged or worn out.
Safety Valve - Inspection
Hot surfaces. Risk of burn. Compressor heads are exposed when filter cover is removed. Allow compressor to cool prior to servicing.
If the safety valve does not work properly, over-pressurization may occur, causing air tank rupture or an explosion. Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.
A dirty air filter will not allow the compressor to operate at full capacity. Before you use the compres- sor, check the air filter to be sure it is clean.
If it is dirty, replace it with a new filter. On some models, the filter may be removed by using a pair of needle nosed pliers or a screwdriver. Pull or pry out

If the overload protector shuts the motor off frequently, check for a possible voltage problem. Low voltage can also be sus- pected when:
SERIOUS INJURY OR DAMAGE MAY OCCUR IF PARTS OF THE BODY OR LOOSE ITEMS GET CAUGHT IN MOVING PARTS. NEVER OPERATE THE OUTFIT WITH THE BELT GUARD RE- MOVED. THE BELT GUARD SHOULD BE REMOVED ONLY WHEN THE COMPRESSOR IS UNPLUGGED. Belt Guard - Removal and Installation
Pulley and Flywheel - Alignment The compressor flywheel and motor pulley grooves must be in-line within 1/32" to assure belt alignment within sheave grooves. To check alignment, unplug compressor and remove the beltguard. Place a straight edge against the outside of the flywheel and measure the distance from it to the nearest groove. Alignment is achieved when the other end of the straight edge is within 1/32" of the measured dimension at the pulley grooves. Servicing Intake and Exhaust Valves The intake and exhaust valves as well as the valve plates and cylinder head will, over a period of time, accumulate a residue of carbon-like material on their surfaces. The material will decrease the efficiency of the compressor. These components should be in- spected whenever a problem is suspected and cleaned or replaced with new parts. Refer to "Outfit PartsListing", if required. Use the following procedure to inspect the parts. 1. Unplug compressor and relieve all air pressure from the air tank. 2. Disconnect the pressure release and outlet lines from the air compressor. 3. Remove the hardware securing the cylinder head and remove the cylinder head and valve plate.
Adjust belt tension by tightening the wing nut until it makes contact with the washer, plus one additional turn. Pressure Switch - Replacement
MANY SOLVENTS ARE HIGHLY FLAMMABLE AND A HEALTH HAZARD IF INHALED. ALWAYS OBSERVE THE SOLVENT MANUFACTURER'S SAFETY INSTRUCTIONS AND WARNINGS.
PRESSURE LOADS BEYOND DESIGN LIMITS MAY CAUSE TANK RUPTURE OR EXPLOSION. PRESSURE SWITCH OPERATION IS RELATED TO MOTOR HP, TANK RATING AND SAFETY VALVE SETTING. DO NOT ATTEMPT TO AD- JUST, REMOVE OR DEFEAT THE PRESSURE SWITCH, OR CHANGE AND MODIFY ANY PRESSURE CONTROL RELATED DEVICE. IF REPLACEMENT IS NECESSARY, THE SAME RATED SWITCH MUST BE USED. CONTACT A SEARS SERVICE CENTER FOR REPLACEMENT. Motor Overload Protector - Reset
The motor has a manual thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. Turn the unit off. To restart, depress the red reset button located on the end of the motor and turn ON/AUTO-OFF switch to the ON position.

PERFORMING REPAIRS MAY EXPOSE VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED AIR SOURCES. PERSONAL INJURY MAY OCCUR. PRIOR TO ATTEMPTING ANY REPAIRS, UNPLUG THE COMPRESSOR AND BLEED OFF TANK AIR PRESSURE.
Excessive tank pressure - safety valve pops off.
Pressure switch does not shut off motor when compressor reaches cut-out pressure.
Move the pressure switch lever to the “O” position. If the compressor doesn’t shut off, disconnect from the electrical outlet source and return to a Sears Service Center to re- place the pressure switch.
Pressure switch cut-out too high.
Return the compressor to Sears Service Center to check and adjust, or replace switch.
Air leaks at fittings or hose.
Tube or hose fittings are not tight enough.
Tighten fittings using teflon tape where air can be heard escaping. Check fittings with soapy water solution. DO NOT OVER- TIGHTEN.
Air leaks at pressure switch release valve.
Defective pressure switch release valve.
Return to Sears Service Center for replace- ment of pressure switch.
Check to see if the pin in the bottom of the pressure release valve is stuck. If it does not move freely, return to the Service Center for replacement of pressure switch.
Defective or dirty check valve.
A defective check valve results in a constant air leak at the pressure release valve when there is pressure in the tank and the com- pressor is shut off. Remove and clean or re- place check valve. DO NOT OVERTIGHTEN.
Air leaks in air tank or at air tank welds.
Defective air tank.
Air tank must be replaced. Do not repair the leak. Return compressor to Sears Service Center.
DO NOT DRILL INTO, WELD OR OTHER- WISE MODIFY AIR TANK OR IT WILL WEAKEN. THE TANK CAN RUPTURE OR EXPLODE.
Air leaks between head and valve plate.
Leaking seal.
Torque head screws to 7-10 ft. lbs. If this does not stop leak, replace seal.

Pressure reading on the regu- lated pressure gauge drops when an accessory is used.
It is normal for some pressure drop to occur.
If there is an excessive amount of pressure drop when the accessory is used, adjust the regulator.
Adjust the regulated pressure under flow con- ditions (while accessory is being used).
Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced .
Air leak from safety valve.
Possible defect in safety valve.
Defective check valve. Loose pulley.
Remove and clean or replace.
Torque pulley set screw.
Low oil level.
Maintain prescribed oil level. Add oil.
Loose flywheel.
Torque screw 15-20 ft. lbs.
Loose compressor mounting screws.
Check screws. Torque as required (15-20 ft.-lbs.)
Loose belt.
Tighten wing nut until it contacts the washer, plus one more turn.
Belt too tight.
Adjust belt tension (see "Belt Replace- ment".)
Carbon build-up.
Remove the head and valve plate. Clean the valve plate and top of the piston. (Be sure carbon does not fall into the cylinder.) Reassemble to 25-30 ft. lbs. using new gasket and torque screws.
Air leaks at or inside check valve.
Defective or dirty check valve. A defective check valve results in a constant air leak at the pressure release valve when there is pressure in the tank and the compressor is shut off. Remove and clean or replace check valve. DO NOT OVER-TIGHTEN.
Excessive belt wear.
Belt is too loose or tight.
Adjust tension instructions. (See "Belt Asjustment or Replacement" section in this manual.
Loose pulley.
Check for worn keyway or pulley bore. Also check for bent motor shaft. Replace parts if necessary. Motor pulley and flywheel must be in line within 1/32". (See "Pulley and Flywheel - Alignment" section in this manual.)
Pulley misalignment.
Squealing sound.
Loose belt.
Adjust belt tension. (See "Belt Replacement" section in this manual.)
Add oil to top of fill hole in base.
There is no oil in the compressor.
Knocking noise

CORRECTION
Compressor is not supply- ing enough air to operate accessories.
Compressor is not large enough for air requirement.
Check the accessory air requirement. If it is higher than the SCFM or pressure supplied by your air compressor, you need a larger compressor.
Restricted air intake filter.
Clean or replace air intake filter. Do not operate the air compressor in any paint spray or drywall sanding area.
Check and replace if required. Hole in hose.
Check valve restricted.
Remove and clean, or replace.
Air leaks.
Tighten fittings.
Loose belt. Adjust belt tension.
Restricted or defective check valve. Remove and clean or replace.
Motor will not run or restart. Present tank pressure exceeds
Motor will start automatically when tank pressure drops below "cut-in" pressure of pressure switch.
pressure switch "cut-in" pressure.
Fuse blown, circuit breaker tripped.
Motor overload protection switch has tripped.
Let motor cool off and overload switch will auto- matically reset.
Possible defective motor or capactior.
Return to Sears Service Center for inspection or replacement, if necessary.
Paint spray on internal motor parts.
Have compressor checked at Sears Service Center. Do not operate the compressor in the paint spray area. See flammable vapor warning.
Check valve stuck open, putting pressure on head.
Remove and clean, or replace the check valve.
Pressure release valve on pressure switch has not unloaded head pressure.
Bleed the line by pushing the lever on the pressure switch to the "O" position; if the valve does not open, replace it.
Dirty or damaged regulator internal parts. Regulator knob continuous air leak. Regulator will not shut off at air outlet.
Replace regulator.

CRAFTSMAN
PERMANENTLY LUBRICATED
TANK MOUNTED AIR COMPRESSOR
MODEL NO. The model number of your Sears Air Compressor can be found on the maintenance label on the top of the shroud or on the bar code label on the rear of the air tank.
CALL 1-800-665-4455* Keep this number handy should you require a service call or
need to order repair parts. If ordering parts make sure you have the name, make and model no. of the merchandise and the name and number of
the part you wish to order.
Regina - 566-5124 Montreal - 333-5740 Toronto - 744-4900 Halifax - 454-2444 Kitchener - 894-7590 Ottawa - 738-4440 Vancouver - 420-8211
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:
All parts listed may be ordered from any Sears Service Center and most Sears stores.
If the parts you need are not stocked locally, your order will be electronically transmitted to a Sears Repair Parts Distribution Center for handling.
Häufige Probleme, wahrscheinliche Ursachen und Lösungen.
| Problem | Mögliche Ursache | Abhilfe | |
|---|---|---|---|
| Excessive tank pressure - safety valve pops off. | Pressure switch does not shut off motor when compressor reaches cut-out pressure. Pressure switch cut-out too high. | Move the pressure switch lever to the “O” position. If the compressor doesn’t shut off, disconnect from the electrical outlet source and return to a Sears Service Center to re- place the pressure switch. Return the compressor to Sears Service Center to check and adjust, or replace switch. | p.14 |
| Air leaks at fittings or hose. | Tube or hose fittings are not tight enough. | Tighten fittings using teflon tape where air can be heard escaping. Check fittings with soapy water solution. DO NOT OVER- TIGHTEN. | p.14 |
| Air leaks at pressure switch release valve. | Defective pressure switch release valve. Defective or dirty check valve. | Return to Sears Service Center for replace- ment of pressure switch. Check to see if the pin in the bottom of the pressure release valve is stuck. If it does not move freely, return to the Service Center for replacement of pressure switch. A defective check valve results in a constant air leak at the pressure release valve when there is pressure in the tank and the com- pressor is shut off. Remove and clean or re- place check valve. DO NOT OVERTIGHTEN. | p.14 |
| Air leaks in air tank or at air tank welds. | Defective air tank. | Air tank must be replaced. Do not repair the leak. Return compressor to Sears Service Center. DO NOT DRILL INTO, WELD OR OTHER- WISE MODIFY AIR TANK OR IT WILL WEAKEN. THE TANK CAN RUPTURE OR EXPLODE. | p.14 |
| Air leaks between head and valve plate. | Leaking seal. | Torque head screws to 7-10 ft. lbs. If this does not stop leak, replace seal. | p.14 |
| Pressure reading on the regu- lated pressure gauge drops when an accessory is used. | It is normal for some pressure drop to occur. | p.15 | |
| Air leak from safety valve. | Possible defect in safety valve. | p.15 | |
| Knocking noise | Defective check valve. Loose pulley. Low oil level. Loose flywheel. Loose compressor mounting screws. Loose belt. Belt too tight. Carbon build-up. | p.15 | |
| Air leaks at or inside check valve. | Defective or dirty check valve. | p.15 | |
| Excessive belt wear. | Belt is too loose or tight. Loose pulley. Pulley misalignment. | Adjust tension instructions. (See "Belt Asjustment or Replacement" section in this manual. Check for worn keyway or pulley bore. Also check for bent motor shaft. Replace parts if necessary. Motor pulley and flywheel must be in line within 1/32". (See "Pulley and Flywheel - Alignment" section in this manual.) | p.15 |
| Squealing sound. | Loose belt. There is no oil in the compressor. | Adjust belt tension. (See "Belt Replacement" section in this manual.) Add oil to top of fill hole in base. | p.15 |
| Compressor is not supply- ing enough air to operate accessories. | Compressor is not large enough for air requirement. Restricted air intake filter. Hole in hose. Check valve restricted. Air leaks. Loose belt. Restricted or defective check valve. | Check the accessory air requirement. If it is higher than the SCFM or pressure supplied by your air compressor, you need a larger compressor. Clean or replace air intake filter. Do not operate the air compressor in any paint spray or drywall sanding area. Check and replace if required. Remove and clean, or replace. Tighten fittings. Adjust belt tension. Remove and clean or replace. | p.16 |
| Motor will not run or restart. | Present tank pressure exceeds pressure switch "cut-in" pressure. Fuse blown, circuit breaker tripped. Motor overload protection switch has tripped. Possible defective motor or capactior. Paint spray on internal motor parts. Check valve stuck open, putting pressure on head. Pressure release valve on pressure switch has not unloaded head pressure. | Motor will start automatically when tank pressure drops below "cut-in" pressure of pressure switch. 1. Check fuse box for blown fuse and replace, if necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit. 2. Check for proper fuse; only Time Delay fuses are acceptable. 3. Check for low voltage conditions and/or proper extension cord. 4. Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit. 5. Check for loose electrical connections. Let motor cool off and overload switch will auto- matically reset. Return to Sears Service Center for inspection or replacement, if necessary. Have compressor checked at Sears Service Center. Do not operate the compressor in the paint spray area. See flammable vapor warning. Remove and clean, or replace the check valve. Bleed the line by pushing the lever on the pressure switch to the "O" position; if the valve does not open, replace it. | p.16 |
| Regulator knob continuous air leak. Regulator will not shut off at air outlet. | Dirty or damaged regulator internal parts. | Replace regulator. | p.16 |
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.