HARDWIRED CONTROL P ANELS USER GUIDE.
2 496679 9752 Hardwired Control Panel User Guide. © Cooper Security Ltd. 2002 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Cooper Security Limited accept any liability for loss or damage caused or alleged to be caused directly or indirectly by this book.
496679 3 1. Introduction The Alarm System The 9752 alarm system comprises a control unit, one or more keypads, and various detectors. The control unit is a box that houses the main controller, power supply, stand-by battery, and any remote communicator.
4 496679 Figure 1. 9930 LCD Remote Keypad. On the 9930 keypad the display shows the state of detector zones, the anti- tamper wiring, and other information as necessary. Glows steadily if the connected telephone line is not working correctly. Glows steadily if the system needs attention from an Engineer or Installer.
496679 5 Omit individual zones or act as an Escape key when entering com- mands. Enter programming and setting/unsetting commands. The 725r Telecommand (Remote Setting Device) If your alarm system has a 9955 radio expander connected to it then you will be able to use a 725r telecommand (also called a remote setting device).
6 496679 2. Everyday Operation There are several different ways of setting the system. For all methods (except using a keyswitch or telecommand ) you must enter your access code at the keypad. The keyswitch method uses a key in a special switch fitted to your premises.
496679 7 2. Key in your access code at the keypad. 3. Press the appropriate Level key. Note: If you press at this point the system sets at Level A. The exit time starts when you press or the Level key. During the exit time the keypads give a continuous exit tone to warn you that the timer is running.
8 496679 The keypad starts the continuous exit tone. 4. Leave via the designated exit route and close the final door. The system sets seven seconds after you close the door and gives a double "beep". The keypad display shows which Level is set.
496679 9 To part set: 1. Close doors and windows in the protected area. 2. Key in your access code at the keypad. 3. Press B (or C or D). The keypad starts the quiet Part Set exit tone (see "Instant Set"). Note: Some Levels on your system may be programmed for Silent Set .
10 496679 Setting From a 725r If your system is fitted with a radio expander and your installer has enabled the appropriate option, you can use a 725r telecommand to set the system. To full set the system: 1. Close all doors and windows. 2. Press . 3.
496679 11 1. Press . The keypad display shows: 2. Carry on and set the system as normal. If you still cannot set the system then call the Installer. What To Do When and Glow If you hear an intermittent tone from the keypad, and both the and lamps glow then your system may have experienced a temporary communi- cation fault.
12 496679 get to the keypad and unset the system. The entry time starts when you open the designated entry door. During the entry time the keypads give a "galloping" entry tone to warn you that the timer is running. 1. Enter through the designated entry door and go to the keypad.
496679 13 T o start a Panic Alarm: On a keypad press 1 & 3 together . Or , on a 725r press and together . T o start a Medical Assistance Alarm: On a keypad press 4 & 6 together . T o start a Fire Alarm: On a keypad press 7 & 9 together . Duress Code There may be a time when an intruder forces you to unset your alarm sys- tem.
14 496679 3. After an Alarm When your system raises an alarm you must disarm it in order to switch off the sounders and strobes. The system keeps a record of which zone(s) triggered the alarms, and shows the zone number(s) on the keypad display. Once you have disarmed the system, you must reset the system before you can start using it again.
496679 15 • If the lamp glows after an alarm and your system is connected to an ARC then your system may use Remote Reset . Your alarm company will give you instructions over the phone and a special code so that you can reset the system from the keypad.
16 496679 4. Special Functions Introduction You can perform a number of other functions from the keypad, apart from setting and unsetting the system. These functions are: [Access code] + A (B, C or D) + Omit zone while setting. [Access code] + Omitting 24 hour zones.
496679 17 The system carries on to set as normal. The system will not raise an alarm if the omitted zone is triggered. Note: The next time you set the system the zone will operate as normal; omission only lasts for one setting/unsetting cycle.
18 496679 User 02 default access code is " 002", User 03 is " 003" and so on up to User 16 ( 016). However, the default access codes for these users cannot set or unset the system, or use any of its special functions. Note: 9850 systems can use four- or six- digit access codes, ask your Installer for more information.
496679 19 edly until the display shows the letter you want. You may already be familiar with typing out short messages on a mobile phone using the same sort of system. Figure 4 shows which letters are assigned to each key. Press C to move the cursor to the next space for a new letter.
20 496679 3. Press to toggle the display between the time and date of the event and the log report. Press 1 to see earlier events in the log. Press 3 to see more recent events. 4. Press to stop using the log. Table 1. Log Event Codes Message Meaning EEProm Fail Internal error, contact Installer.
496679 21 Tel Line Fault Communications (telephone line) fault detected. Tel Line Rstr Communications restored. Comms Fail The communicator failed to report. AC Fail Mains failed. AC Restore Mains restored. Low Battery Standby battery is low. Low Batt Rstr Standby battery restored.
22 496679 6. Key in two digits for the hour followed by . (Use the 24 hour clock.) 7. Key in two digits for the minutes, followed by . The display shows the new time and date: Turning the Chime On/Off Your system may be programmed so that a chime tone sounds whenever certain doors are opened while the system is unset.
496679 23 As you trigger a detector the keypad and internal sounder give a short tone. The display shows the zone number of any detector(s) that you have triggered. If there is more than one detector triggered then the display show the number of each detector in turn.
24 496679 Issue 1 ZONE DESCRIPTION WHOLE SYSTEM (A) PA R T SET B PA R T SET D PA R T SET C OMIT ALLO WED CHIME 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Be.
Ein wichtiger Punkt beim Kauf des Geräts Cooper Bussmann 9752 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Cooper Bussmann 9752 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Cooper Bussmann 9752 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Cooper Bussmann 9752 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Cooper Bussmann 9752 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Cooper Bussmann 9752 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Cooper Bussmann 9752 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Cooper Bussmann 9752. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Cooper Bussmann 9752 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.