Introduction Prerequisites Requirements Components Used Conventions EIA/TIA−232 Speed and Distance Limitations Serial Cable CAB−232MT EIA/TIA−232 Serial Cable Assembly EIA/TIA−232 DTE Cable Pinouts Serial Cable CAB−232FC EIA/TIA−232 DCE Cable Pinouts (DB−60 to DB−25) Related Information
This document provides the technical specifications for the EIA/TIA−232 serial cables.
There are no specific requirements for this document.
This document is not restricted to specific software and hardware versions.
The information in this document was created from the devices in a specific lab environment. All of the devices used in this document started with a cleared (default) configuration. If your network is live, make sure that you understand the potential impact of any command.
For more information on document conventions, see the Cisco Technical Tips Conventions.
As with all signaling systems, EIA/TIA−232 signals can travel a limited distance at any given bit rate; generally, the slower the data rate, the greater the distance.
The table below gives the EIA/TIA−232 speed and distance limitations.
Data Rate (Baud) Distance (Feet) Distance (Meters)


This section presents the cable assembly and pinouts for the CAB−232MT serial cable.

The cable gender for this product (part number 72−0793−01) is Male − Male, mode − DTE.
The CAB−232MT cable is used in the Cisco 7000 family, Cisco 4000 series, Cisco 3600 series, Cisco 2500 series, Cisco 1600 series, Cisco access servers, and AccessPro PC cards. This cable has a male DB−60 connector on the Cisco end and a male DB−25 connector on the network end.

The table below shows the EIA/TIA−232 DTE cable pinouts (DB−60 to DB−25).



− 1Any pin not referenced is not connected.
− · − · Shield

This section presents the cable assembly and pinouts for the CAB−232FC serial cable.
The cable gender for this product (part number 72−0794−01) is Male DB−60 to Female DB−25, mode − DCE.

This cable is used in the following systems: the Cisco 7000 family, Cisco 4000 series, Cisco 3600 series, Cisco 2500 series, Cisco 1600 series, Cisco access servers, and AccessPro PC cards. This cable has a male DB−60 connector on the Cisco end and a female DB−25 connector on the network end.
The table below shows the EIA/TIA−232 DCE cable pinouts (DB−60 to DB−25).