Benutzeranleitung / Produktwartung 78-10588-03 des Produzenten Cisco Systems
Zur Seite of 30
CHAPTER 3-1 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 3 Installing the Chassis This chapter describes ho w to install and test the Cisco Metro 1500 series system chassis. The equipment is installed during normal working hours. It is usually connected to acti ve CPU channels or control units after working hours.
Chapter 3 Installing the Chassis Before Installing 3-2 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Caution Use extreme care when remo ving or installing connectors so you do not damage the connector housing or scratch the end-face surface of the f iber .
3-3 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Chapter 3 Installing the Chassis Before Installing Upon receipt, inspect the equipment as follows: Step 1 T ake in ventory . Compare the equipment inside with the packing slip and the equipment list provided by customer service.
Chapter 3 Installing the Chassis Installing the System 3-4 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Caution Because of rack mounting, the plugs of the power cables on the rear side of the unit might not be accessible. Please provide a po wer circuit breaker to allo w front po wer access.
3-5 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Chapter 3 Installing the Chassis Installing the System Step 10 Change default passwords. See Appendix E, “Unit Maintenance and Netw ork Record. ” Step 11 Log in as root and def ine network settings.
Chapter 3 Installing the Chassis Installing the System 3-6 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Step 4 Insert the NEMI module carefully into the chassis slot while guiding the upper and lower edges of the module in the tracks until its connectors come into contact with the backplane connectors.
3-7 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Chapter 3 Installing the Chassis Installing the System Installing the DEMI Module T o install a DEMI module, follo w these steps: Step 1 Remov e the acrylic front cov er from the unit in which the module should be added.
Chapter 3 Installing the Chassis Connecting Power 3-8 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Step 5 Hold the module in position after making full contact and use the two scre ws on the front panel of the module to secure it in the housing.
3-9 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Chapter 3 Installing the Chassis Connecting Power Connecting AC Power T o connect A C power , follow these steps: Step 1 Connect the po wer supply cords to po wer 1 and po wer 2 on the rear panel of the unit.
Chapter 3 Installing the Chassis Connecting Power 3-10 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Figur e 3-4 Fr ont P anel of the Cisco Metro 1500 The keyswitch is secured against rotation. The k e y can be remov ed in either the ( 0 ) or ( | ) position.
3-11 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Chapter 3 Installing the Chassis Connecting Power Connecting DC Power The system is equipped with two PSMs and two DC po wer cables. There are tw o DC powered v ersions of the Cisco Metro 1500 Series.
Chapter 3 Installing the Chassis Connecting Power 3-12 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Figur e 3-5 Rear P anel of the PSM (US V ersion) Caution Do not use damaged terminal blocks.
3-13 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Chapter 3 Installing the Chassis Connecting Power Figur e 3-6 Connecting Wir es Step 4 Connect the three wires on the other end to the corresponding high current connectors of the power distrib ution unit.
Chapter 3 Installing the Chassis Connecting Power 3-14 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 The chassis powers up as soon as the corresponding po wer switch of the PDU is turned on.
3-15 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Chapter 3 Installing the Chassis Connecting Power Caution T ighten the scre w of the plug to a void loss of connection.
Chapter 3 Installing the Chassis Connecting Power 3-16 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Figur e 3-9 48 VDC Application P o wer Cable Caution Make sure that the three wires on the po wer cables are correctly f ixed at the terminal clamps of the unit and at the connectors of the PDU.
3-17 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Chapter 3 Installing the Chassis Connecting Power Step 5 T urn the power on using the corresponding power switch of the PDU. The chassis powers up as soon as the corresponding po wer switch of the PDU is turned on.
Chapter 3 Installing the Chassis Cleaning the System 3-18 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 T able 3-1 lists the po wer requirements in dif ferent countries. Grounding the Chassis Connecting the power cords to the chassis provides basic grounding.
3-19 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Chapter 3 Installing the Chassis Cleaning the System Cleaning the Chassis Be very careful with the air f low system when you clean the chassis. If the cleaning process has to be done while the system is on, be aw are that the airf low system is in operation.
Chapter 3 Installing the Chassis Cleaning the System 3-20 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Before installing any type of cable or connector , use a lint-free alcohol pad from a cleaning kit to clean the ferrule, the protectiv e white tube around the f iber , and the end-face surface of the f iber .
3-21 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Chapter 3 Installing the Chassis Removing the Power Supply Module • Cov er the connector adapters to av oid soiling or contaminating the inside of the adapters while cleaning the chassis.
Chapter 3 Installing the Chassis Removing the Power Supply Module 3-22 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 The display on the front panel of the chassis indicates whether the power is on or off. Y ou can also monitor power status from the NEMI.
3-23 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Chapter 3 Installing the Chassis Removing the Power Supply Module Determining Power Supply Status If the LED on a power supply is o.
Chapter 3 Installing the Chassis Removing the Power Supply Module 3-24 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Figur e 3-1 1 Rear View of P ower Supply Module All PSMs are hot-swappable and can be replaced while the system is in service.
3-25 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Chapter 3 Installing the Chassis Running Online Tests Running Online Tests Note The power le vels cannot be checked without special measurement equipment because of the automatic laser shutdo wn (ALS).
Chapter 3 Installing the Chassis Running Online Tests 3-26 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Measuring Channel Outputs and Channel Budgets Channel module outputs, measure.
3-27 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Chapter 3 Installing the Chassis Running Online Tests Step 3 Use the ocmstate command to switch on the local loop. No w you can measure the output po wer at point F . Afterwards, switch of f the local loop.
Chapter 3 Installing the Chassis Troubleshooting 3-28 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Troubleshooting If trouble occurs during installation, check T able 3-2 for a list of troubleshooting tips. If the solution is not in the table, contact your Cisco service representativ e.
3-29 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03 Chapter 3 Installing the Chassis Troubleshooting Not receiving remote data Fiber-optic connectors are loose. Check and reseat connectors. Tx-Rx connectors are not matched. Switch Tx-Rx connectors.
Chapter 3 Installing the Chassis Troubleshooting 3-30 Cisco Metro 1500 Series Hardware Installation Guide 78-10588-03.
Ein wichtiger Punkt beim Kauf des Geräts Cisco Systems 78-10588-03 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Cisco Systems 78-10588-03 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Cisco Systems 78-10588-03 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Cisco Systems 78-10588-03 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Cisco Systems 78-10588-03 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Cisco Systems 78-10588-03 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Cisco Systems 78-10588-03 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Cisco Systems 78-10588-03. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Cisco Systems 78-10588-03 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.