Manufacturer reserves the right to disco ntinue, or change at any time, specifications or de signs without notice and without inc urring obligations. Catalog No .
2 Table 2 — Accessory Pac kage Content s Choose a space that can support the weight of the cooler and economizer with service clearances and area for refrigera nt piping. Field-supplied piping must be limited to less than 50 lineal ft (15.25 m) or 75 equivalent ft (22 m) in length.
3 ECONOMIZER S UCTION S ERVICE VA LV E 3 0X A REMOTE COOLER IND OO R L OC AT I O N ECONOMIZER S UCTION S ERVICE VA LV E REMOTE COOLER 3 0XA IND OO R L OC AT I O N 15 FT MAX ECONOMIZER S UCTION S E R VICE V A L VE REMOTE COOLER 3 0X A INDOOR LOCA TION 15 FT MAX Fig.
4 INST ALLA TION 1. Inspect package contents for missing or damaged parts. File a claim with the shipping agency if parts are damaged and notify your loca l Carrier representative if any item is missing.
5 Table 4A — Refrigeration Line Sizes (English) Table 4B — Refrigeration Line Sizes (SI) Table 5 — Cooler and Economizer Weights 30XA UNIT SIZE SUCTION LINE DOUBLE SUCTION RISERS COOLER LIQUID LINE CONDENSER LIQUID LINE ECONOMIZER LINE Circuit A Circuit B Circuit A (in.
6 S IDE VIEW BOTT OM VIEW 1 3 /16 (20) 1/2 (1 3 ) 10-2 3 / 3 2 (272) 11 8 -1 3 /16 ( 3 017) 52-1/4 (1 3 27) 52-1/4 (1 3 27) 2 3 -1/ 3 2 (5 8 5) 15-5/16 ( 38 9) 64 (1625) 15-5/16 ( 38 9) 45-1/4 (1149) 15-5/16 ( 38 9) 19-21/ 3 2 (499) DET AIL A S CALE 2:1 TYP 6 PLACE S S EE DET AIL A Fig.
7 S IDE VIEW BOTT OM VIEW 1/2 (1 3 ) 1 3 /16 (20) 11- 3 /16 (2 8 4) 119-9/ 3 2 ( 3 0 3 0) 52-1/4 (1 3 27) 25-1/16 (6 3 6) 52-1/4 (1 3 27) 1 8 - 3 / 8 (466) 57 (144 8 ) 1 8 - 3 / 8 (466) 52-1/4 (1 3 27.
8 S IDE VIEW END VIEW T OP VIEW 3 0- 3 / 8 (770) 22-7/ 8 (5 8 1) 2 3 -1/2 (59 8 ) 7-7/ 8 (200) 2 x Ø 7/16 (11) 29- 3 / 8 (746) 6-1/2 (166) 7/16 (12) 5/ 8 (17) 7/16 (11) 7/ 8 (21) 7/16 (11) 7/ 8 (21) .
9 Fig. 6 — Typical Cooler Piping-Cool er Side View ( 30XA140, 160 Shown) NO TES: 1. Circuit A uses steel suction piping. 2. Circuit B uses copper suction piping.
10 Remote Cooler and Economizers Installa- tion — Install the cooler an d economizers in a remote location by following this procedure: NOTE: Throughout the Remote Cooler and Economizers Installation steps, the two acces sory package part no. (00EFN900003000A, 00EFN900003100A) have been short- ened to 3000A and 3100A.
11 12. Using the accessory-supp lied M6 screws (3000A or 3100A: Item 6), install the accessory-supplied junction box (3000A or 3100A: Item 5) at the desired location where the entering and leaving water thermistor cables can be conveniently spliced. One or two knockouts can be used.
12 Table 6 — Materials Required for Ste el Piping Flange Connections LEGEND *Copper connection. UNIT SIZE COOLER PIPE FLANGE CONNECTION FL EX CONNECT OR FLANGE CONNECTION Circuit A Circuit B Circuit A Circuit B 140 Field supplied: ASME B16.9 Stub End 4 in.
13 Table 6 — Materials Required for Steel Pip ing Flange Connect ions (cont) LEGEND Table 7 — Additional Refr igerant Charges Requir ed UNIT SIZE COOLER PIPE FLANGE CONNECTION FLEX CONNECT OR FLANGE C ONNECTION Circuit A Circuit B Circuit A Circuit B 280 Field supplied: ASME B16.
14 TO 30X A B RED . TEE 90 DEGREE STR ELLS FROM COOLER 45 DEGREE STR ELLS A 3 0XA PRE SS URE RELIEF VA LV E S (FIELD- S UPPLIED) ECONOMIZER LINE LIQUID LINE ( 3 0XA TO ECONOMIZER) MANUAL S HUTOFF V AL.
15 A S ME B16.9 S TEEL S TUB END (FIELD- S UPPLIED) PIPE FLANGE (ACCE SS OR Y - S UPPLIED , S EE T ABLE 6) MOUNTING BRACKET EXI S TING FLANGE ON FLEX CONNECT OR A T 3 0XA BA S E UNIT 8 HOLE S 1 (25) EQU ALL Y S P ACED 1 EXTRA HOLE M16 7-7/ 8 (200) 22.
Manufacturer reserves the right to disco ntinue, or change at any time, specificatio ns or designs without notice and without inc urring obligations. Catalog No .
Ein wichtiger Punkt beim Kauf des Geräts Carrier 00EFN900003000A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Carrier 00EFN900003000A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Carrier 00EFN900003000A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Carrier 00EFN900003000A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Carrier 00EFN900003000A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Carrier 00EFN900003000A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Carrier 00EFN900003000A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Carrier 00EFN900003000A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Carrier 00EFN900003000A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.