Benutzeranleitung / Produktwartung LTR20121002 des Produzenten Cal Spas
Zur Seite of 40
L TR20121002, Rev . A 12/30/11.
Preparing for Your New Inground Spa Inground Spa Installation Checklist ....... 4 Planning the Best Location For Your Spa ... 4 Planning the Best Place for the Outdoor Equipment Pack ....................... 5 Inground Spa Site Preparation ........... 5 Spa Shell Dimensions and Side Views .
Inground Spas L TR20121002, Rev . A Read This First! w ww . c a l s p a s . c o m 3 When installing and using this electrical equipment, always follow basic safety precautions. Following these instructions will help make your rst spa ses - sion a pleasurable one.
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 4 Most cities and counties require permits for exterior construction and electrical circuits.
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 5 The Designer Spa series requires an external equip- ment pack. When locating the outdoor equipment pack, you will want to consider the f ollowing: The equipment pack must be located within a • maximum of 15 feet from the spa.
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 6 Spa Shell Dimensions and Side Views IG-401.
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 7 IG-402.
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 8 IG-403.
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 9 IG-404.
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 10 IG-405.
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 11 IG-406.
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 12 IG-407.
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 13 All 240V spas must be permanently connected (hard wired) to the power supply . These instructions de - scribe the only acceptable electrical wiring procedure.
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 14 GFCI Wiring Diagram.
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 15 All 230V spas must be permanently connected (hard wired) to the power supply . These instructions de - scribe the only acceptable electrical wiring procedure.
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 16 RCD Wiring Diagram .
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 17 Installing the Inground Shell.
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 18 Equipment Pack Plumbing Connections Equipment Pack Specications All Inground spas except IGJ-407: Equipment pack weight = 250 lbs. IGJ-407: Equipment pack weight = 300 lbs.
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 19 Gate/Slice Valves The use of gate valves is recommended on all plumb- ing lines (both suction and return lines). These valves are used to contain the spa’ s water in either the equip- ment or the spa.
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 20 Remote Equipment Topside Control Panel The next few steps to complete the installation should be performed along wi th installation of the tempera- ture sensor and 12V spa light wiring (if applicable).
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 21 Inground Spa Light Installation In- structions On spas ordered with inground lights, the factory installs the light niche for you. The next steps of installation should be performed by a qualied licensed electrician.
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 22.
Inground Spas L TR20121002, Rev . A Pr eparing for Y our New Ingr ound Spa w ww . c a l s p a s . c o m 23 Pouring the Deck It is recommended that all electrical hook ups and all plumbing be completed before pouring the concrete.
Inground Spas L TR20121002, Rev . A Operating Y our Spa w ww . c a l s p a s . c o m 24 9800 Electronic Control Operation Initial Start-up When rst powered up, your spa will perf orm a self -diagnostic check and then automatical ly go into priming mode.
Inground Spas L TR20121002, Rev . A Operating Y our Spa w ww . c a l s p a s . c o m 25 on, the equipment will automatically turn off after 15 minutes. Light Press the “LIGHT” button to turn the spa light on and off and to shi ft between dim and bright settings if your light is dimmable.
Inground Spas L TR20121002, Rev . A Operating Y our Spa w ww . c a l s p a s . c o m 26 Y our new Cal Spa comes equipped with an electric heater . Following the directions listed below will ensure the most efcient operation: NOTE: This method is only f or spa usage under two hours a week.
Inground Spas L TR20121002, Rev . A Operating Y our Spa w ww . c a l s p a s . c o m 27 Diagnostic Messages Message Meaning Action Required No message on display 1) Spa temperature is unknown. 1) After pump has been running f or 2 minutes tempera - ture will be displayed.
Inground Spas L TR20121002, Rev . A Operating Y our Spa w ww . c a l s p a s . c o m 28 Message Meaning Action Required HH OHH Overheat protection (spa is shut - down). One sensor has detected 118˚F (48˚C) at the heater . DO NOT ENTER THE W A TER! Remo ve the spa cover and allow spa to cool below 107˚F (42˚C).
Inground Spas L TR20121002, Rev . A Operating Y our Spa w ww . c a l s p a s . c o m 29 Adjustable Jets Almost all of the jets in your spa are adjustable. Rotating the face of an adjustable jet to the left (counter-clockwise) will decrease the amount of water ow through the jet.
Inground Spas L TR20121002, Rev . A Clear W ater Plan w ww . c a l s p a s . c o m 30 Clear Water Plan This section is intended for new spa owners with no experience with water chemistry . Everyone’s ex- perience with maintaining water quality is diff erent, but there are some general concepts you need to know .
Inground Spas L TR20121002, Rev . A Clear W ater Plan w ww . c a l s p a s . c o m 31 Testing and Adjusting Spa Water Y ou have two types of testing methods to choose f rom: The • reagent test kit is a method which provides a high lev el of accur acy .
Inground Spas L TR20121002, Rev . A Clear W ater Plan w ww . c a l s p a s . c o m 32 Using Chlorine as a Sanitizer If you choose to use chlorine as a sanitizer , only use granulated chlorine, not liquid chlorine. Once a week, check the chlorine level using either a test strip or a reagent kit.
Inground Spas L TR20121002, Rev . A Clear W ater Plan w ww . c a l s p a s . c o m 33 Shocking the Water In addition to using a chemical sani tizer , you will periodically need to shock the w ater .
Inground Spas L TR20121002, Rev . A Clear W ater Plan w ww . c a l s p a s . c o m 34 “Bather Load” is the term used to describe the num- ber of people using a spa, combined with the length of usage, and the frequency of usage. All these fac- tors have a great effect on the spa w ater .
Inground Spas L TR20121002, Rev . A Clear W ater Plan w ww . c a l s p a s . c o m 35 Maintenance Schedule Each time you rell the spa Follow the section “Starting the Spa with Fr esh W ater” . Prior to each use T est the spa water using either test strips a r eagent test kit.
Inground Spas L TR20121002, Rev . A Cleaning and Maintenance w ww . c a l s p a s . c o m 36 Removing and Reseating the Pillows Y ou can remov e the pillows for cleaning and maintenance quickly and easily . This method works for all types of pillows. Grab the lower edge of the pillow with both hands rmly and pull up.
Inground Spas L TR20121002, Rev . A Cleaning and Maintenance w ww . c a l s p a s . c o m 37 Draining Your Spa Y our spa should be drained every four to six months, and relled with fresh tap water . The following is the recommended method for dr aining your spa.
Inground Spas L TR20121002, Rev . A Cleaning and Maintenance w ww . c a l s p a s . c o m 38 Cleaning Your Spa Spa Cover and Pillows Due to the constant punishment your spa cover and pillows receive, you should protect them by applying a vinyl and leather cleaner as part of your monthly maintenance plan.
Inground Spas L TR20121002, Rev . A Appendix w ww . c a l s p a s . c o m 39 Appendix Replacement Parts Jets ELE 2” Euro No Eyeball PLU282050W mfc 3” Directional PLU283050W PSR 5” Rim PLU285052W.
L TR20121002, Rev . A 12/30/11 LMS Customer Service Department 1462 East Ninth Street Pomona, CA 91766 T oll Free: 1-800-CAL-SP AS Fax: 1-909-629-3890 www .
Ein wichtiger Punkt beim Kauf des Geräts Cal Spas LTR20121002 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Cal Spas LTR20121002 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Cal Spas LTR20121002 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Cal Spas LTR20121002 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Cal Spas LTR20121002 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Cal Spas LTR20121002 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Cal Spas LTR20121002 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Cal Spas LTR20121002. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Cal Spas LTR20121002 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.