Benutzeranleitung / Produktwartung LCC-2 des Produzenten Bunn
Zur Seite of 26
R EG U LA R D EC A FE R EF IL L R EA D Y PO W ER RIN S E C AR AF E ´ H O T W A T ER ST O P ! 2 . P r e ss an d hol d w he n i n m an u al m od e or pre ss an d rel e as e w hen in por tion m od e 1 .
2 39288 050511 BUNN-O-MA TIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor . 2) Electronic circuit and/or control boards: parts and labor for 3 years.
3 Warranty .................................................................................................................................................2 User Notices ................................................................................
4 USER NOTICES Carefully read and follow all notices on the equipment and in this manual. They were written for your protec- tion. All notices are to be kept in good condition. Replace any unreadable or damaged labels. 00986.0002 11646.0002 37881.0000 39288 060711 40054.
5 ELECTRICAL REQUIREMENTS Refer to Data Plate on dispenser , and local/national electrical codes to determine circuit requirements. WARNING - If the power cord is ever damaged, it must be replaced by the manufacturer or its service agent with a special cord available from the manufacturer or its service agent in order to avoid a hazard.
6 INITIAL SET -UP NOTE: The LCC-2 LP weighs approximately 70 lbs. (32 kg). If necessary , use more than one person when lifting or moving the dispenser . 1. Cut the plastic bands and remove the top box. 2. Locate and remove the parts box from top of packaging and set aside.
7 OPERA TING CONTROLS AND INTERF ACE Refer to the photos on the following page for the location of these features. 1. Dispense Switches: Push to dispense product. 2. Stop Switch: Momentary switch stops all dispense functions. 3. Hot Water Switch: Push and Hold switch to dispense hot water from the center dispense tip.
8 14 11 12 13 2 4 1 3 7 8 5 6 9 10 39288 083106.
9 INST ALLING PUMP TUBING INST ALLING THE PUMP TUBING Refer to the T ube Replacement Instruction inside the Cabinet door . 1. Loosen the thumbscrew securing the tubing retainer plate to the pump body and set the retainer plate aside.
10 INITIAL FILL & HEA T 1. Select Normal on the Function Selector Switch and Run on the Mode Selector Switch. 2. Confirm the water supply is on. 3. Connect the dispenser to the power sour ce. The Red POWER LED will illuminate and water will begin flowing into the tank.
11 Rinse Alarm Feature Periodic rinsing of the mix chambers and dispense tips is essential for proper maintenance and optimum performance of the dispenser .
12 PROGRAMMING THE DISPENSER Open the dispenser door to access the digital programming module with LED display . T wo basic modes are available to the operator: Display Mode and Program Mode. T o enter the Display Mode, Set the RUN/NIGHT/PROGRAM Switch to the RUN position.
13 Regular Dispense T otal Displays T otal Regular Coffee Dispensed (XX.X Gal) Decaf Dispense T otal Displays T otal Decaf Coffee Dispensed (XX.X Gal) Displays Software Version # - Exits T o Home View After 3 Seconds.
14 PROGRAMMING THE DISPENSER (Cont.) Program Mode : Used to change or enter new set-up values. T o enter the Program Mode , Set the RUN/NIGHT/PROGRAM Switch to the PROGRAM position, the unit will display “__PPP” to indicate it is in the Program Mode.
15 Right (Decaf) Dispense T otal LCD DISPLA Y PROGRAM MODE DESCRIPTION PROGRAMMING THE DISPENSER (Cont.) Program Mode (Continued) Empty Product Threshold Set Conductance Threshold Default = 600 Range = 100 Min / 900 Max T o check Conductance of Hot Water , view the display while rinsing.
16 PRIMING THE CONCENTRA TE LINES 1. Open the dispenser door . 2. Select Prime on the Function Selector Switch and Run on the Mode Selector Switch. 3. Close the dispenser door . 4. Place a container under the dispense tip. 5. Activate the appropriate dispenser until concentrate flows from the dispense nozzle.
17 OPERA TING THE DISPENSER Set the Function Selector Switch to “Normal” and the Mode Selector Switch to “Run .” 1A. Push and Hold Dispense Mode (Cup at a time). See Programming Functions to set this amount. a. Place cup on the tray beneath the dispensing tip.
18 CLEANING & PREVENT A TIVE MAINTENANCE General Cleaning and Sanitizing Procedures Note: The BUNN ® LCC-2 LP dispenser incorporates a “user selectable” rinse reminder feature, which lights the Rinse LED on the front panel when it is time to rinse.
19 REPLACING THE PUMP TUBING The pumps and tubing used in the dispenser are designed to give maximum performance and long life. However , the tubes are a wear item and must be replaced periodically . How long the tubes last is dependent on usage and properties of the concentrate.
20 Right (Decaf) Water Rate Set PRIME-NORMAL-RINSE switch to RINSE position. Press and hold Decaf Dispense Switch until flow stops (20 sec.) Refer to Field Calibration of the Concentrate Pumps. LCD DISPLA Y CALIBRA TION MODE DESCRIPTION CALIBRA TING THE DISPENSER Left (Regular) Pump Cal.
21 CALIBRA TING THE DISPENSER (Cont.) LCD DISPLA Y CALIBRA TION MODE DESCRIPTION Right (Decaf) Water Rate Enter Liters collected from the 20 sec. test above. Default = 1.08 Range = 0.95 - 1.12 Liters Cooler Control T emperature Delays the Pump turn off after a dispense.
22 LED DISPLA Y ERROR DESCRIPTION/TROUBLESHOOTING TROUBLESHOOTING GUIDE Error Codes When an error has occurred, all Door LED’ s will be flashing. Open the Door to access the LED Display and record the Error Code. Refer to the list of Error Codes below to identify the problem.
23 TROUBLESHOOTING GUIDE (Cont.) Error Codes (Continued) LED DISPLA Y ERROR DESCRIPTION/TROUBLESHOOTING T ank T emp Sensor Failed Sensor Reading Out Of Range (High or Low). Faulty Sensor wiring. Switch Board Failure Unable T o Communicate With The Switch Board In The Door .
24 (Continued Next Page) Field Calibration of the Concentrate Pumps & Dispenser Flow Rates The factory set default values for the Pump & Dispenser Flow Rates are ver y accurate and typically do not need to be field calibrated.
25 Field Calibration of the Concentrate Pumps & Dispenser Flow Rates (Continued) 5. Place a 1500 to 2000 ml graduated container under Left Dispense Tip. 6. Press & Hold the Regular dispense switch. The dispenser will display a 20 second count down timer and then stop dispensing automatically .
26 39288 083106 BLU/BLK-16 RED-22 WHT/BLK-22 WHT/BLU-22 WHT/BLU-22 WHT/BLK-22 TA N-22 M BOARD SWITCH & LED RED/BLK-18 RPM SENSOR RIGHT PUMP M RPM SENSOR LEFT PUMP WHT/RED-18 BRN/WHT-18 BRN/BLK-18 .
Ein wichtiger Punkt beim Kauf des Geräts Bunn LCC-2 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bunn LCC-2 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bunn LCC-2 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bunn LCC-2 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bunn LCC-2 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bunn LCC-2 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bunn LCC-2 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bunn LCC-2. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bunn LCC-2 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.