Benutzeranleitung / Produktwartung JDF-4S des Produzenten Bunn
Zur Seite of 28
INST ALLA TION & OPERA TING MANUAL BUNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 T o obtain the Illustrated Parts Catalog, visit the Bunn-O-Matic website, at www.bunn.com.
2 BUNN-O-MA TIC COMMERCIAL PRODUCT W ARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor . 2) Electronic circuit and/or control boards: parts and labor for 3 years.
3 USER NOTICES Carefully read and follow all notices on the equipment and in this manual. They were written for your protec- tion. All notices are to be kept in good condition. Replace any unreadable or damaged labels. 27442.0000 00986.0002 33461.0001 JDF-2S CHARGE T ype R134A, Amount 9 oz (255 gm) Design Pressures: High 255 psi (15.
4 PLUMBING REQUIREMENTS This dispenser must be connected to a COLD WA TER system with operating pressure between 20 and 100 psi (138 and 690 kPa). This water source must be capable of producing a minimum flow rate of 3 fluid ounces (88.7 milliliters) per second.
5 DOOR COVER INST ALLA TION 1. Install door cover by first plugging the door harness connector into the machine harness connector located at the bottom of the machine door .
6 INITIAL FILL CAUTION: The dispenser must be disconnected from the power source throughout the initial fill except when specified in the instructions. 1. Remove drip tray assembly and splash panel from the dispenser . Replace the drip tray . 2. Connect the water source to the back of the dispenser .
7 FIG 5 Initial Fill Connection - JDF-2S P3582 7. T urn ON the refrigeration switch at the back of the dispenser . This will start the water bath pump circula- tion. 8. Check water level in the overflow tube and top off the tank if necessary (Step 5).
8 LOADING Frozen Concentrates 1. Thaw the frozen concentrate in a refrigerated 35-40 degrees F (1.6-4.4 degrees C) environment for 36 to 48 hours before use. 2. Thoroughly mix the thawed concentrate by vigorously shaking the product container . 3. Open the dispenser door .
9 OPERA TING CONTROLS FIG 7 Refrigeration Switch - JDF-2S FIG 9 Product Dispense Switches - JDF-2S DISPENSER USE Press and Hold Dispensing: 1. Place a cup on the drip tray beneath the desired dispensing nozzle. 2. Press and hold the “Product Dispense” switch until the beverage reaches the desired level, then release.
10 OPERA TING CONTROLS (Continued) Portion Control Option The dispenser is also equipped with a portion control option. The following steps will guide you through the set up process for this option. Portion control can be set on one or all dispense heads as needed.
11 P3585 FIG 12 T emperature LEDs JDF-2S FIG 13 T emperature LEDs JDF-4S Procedure to return all dispense heads back to Push and Hold mode: 1. Unplug dispenser from power source. 2. Place Dispense Lockout switch in the OFF position. 3. Remove drip tray and splash panel from the front of the machine then replace the drip tray .
12 CLEANING & PREVENTIVE MAINTENANCE Daily: Rinse Procedure T ools required: 32 oz. (946 ml) minimum empty container 1. Open refrigerated compartment door and remove product containers. 2. Fill a clean container with warm water and place the container into the cabinet and press it firmly into the bottle adapter opening.
13 39992 042007 CLEANING (cont) Monthly: Clean Condenser Coils 1. Use a soft bristle brush to clean the build up of dirt in the condenser . NOTE: Some models include a removable filter that can be cleaned in warm soapy water . Annually: Replace Pump T ubing 1.
14 6. Repeat steps 1 through 5 as necessary until the correct water flow rate is achieved. 7. Repeat steps 1 through 5 for the remaining dispense positions. 8. Place the Dispense Lockout switch back into the ON position. Pump Speed Adjustment 1. Disconnect the dispenser from the power source.
15 T otal Dispense Ratio Set Up Procedure 1. Adjust water flow as described in W ater Flow T esting and Adjustment . Record water output setting for later reference on each dispense head.
16 ADJUSTMENT & OPTIONAL SETTINGS (cont) Dispenser Lockout Dispense functions of the dispenser can be turned-off to prevent unauthorized use of the dispenser , while keeping the refrigeration system running. 1. Locate the Dispense Lockout switch at the bottom front of the dispenser behind the drip tray .
17 Circuit Board LED Indicators - JDF-2S LED # LED Color Illuminates: 1 Green When the compressor should be ON. 2 Cabinet Red When the cabinet temperature is above 50 degrees F . Flashes slowly when cabinet temperature exceeds 50 degrees F for 4 hours.
18 39992 042007 FIG 16 JDF-4S FUNCTION LIST (Continued) Circuit Board LED Indicators - JDF-4S LED # LED Color Illuminates: 1 Bath Red When bath temperature is above 34 degrees F . Flashes slowly when compressor is in a 6 minute delay period. Open bath thermistor circuit will flash #4 and #5 LED’ s 1 time ever y 3 seconds.
19 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T echnical Ser vice Department.
20 TROUBLESHOOTING (cont.) Check for "ON" position or no con- tinuity - replace switch. Clean filter and fins or replace con- denser filter . (Filter not supplied on some machines). A) Check for 120V or 230V AC. Re- place fan motor or check fan blades for obstructions.
21 TROUBLESHOOTING (cont.) Dispense station not working All stations dispense concentrate only 1. Dispense Lockout switch set to OFF position. 2. Dispense switch failed Main water supply Frozen bath Inlet water valve failed Place switch in ON position.
22 TROUBLESHOOTING (cont.) Dispense station concentrate only Dispense station water only Replace solenoid (24vdc) or check wire connection between water valve and main control board. Replace refill concentrate container or BIB Check for proper counter clockwise rotation of pump rollers.
23 TROUBLESHOOTING (cont.) Water leak filling drip tray or around dispense deck area Water leaking beneath machine Erratic spray during dispense Dispense nozzle dripping water 1. Initial fill/setup 2. Dispense deck 3. W ater pressure greater than 100psi 1.
24 TROUBLESHOOTING (cont.) Unit is not working Difficulty brixing and/or weak bev- erage Difficulty brixing and/or weak bev- erage Difficulty brixing bag-in-box 1. Step-down transformer . 2. Main control board. 1. Product viscosity or too cold. 2. Low water pressure.
25 COOLANT SCHEMA TIC DIAGRAM CONDENSER SUCTION ACCUMULA TOR COMPRESSOR EV APORA TOR PROCESS TUBE FIL TER DRYER 39992 042007.
26 39992 042007 J6-1 J6-3 C O N T R O L P C B O A R D J5-1 J5-4 J2-1 J2-6 GRN LIMIT THERMOST A T K2 K2 COMP . COMPRESSOR ASSEMBL Y WHI/ORN LEFT DISPENSE RIGHT DISPENSE LEFT DISPENSE RIGHT DISPENSE YEL YEL W H I / VI O RECIR.
27 39992 042007 J6-1 J6-3 C O N T R O L P C B O A R D J5-1 J5-4 J2-1 J2-6 GRN LIMIT THERMOST AT K2 K2 COMP . COMPRESSOR ASSEMBL Y WHI/ORN ST ATION 1 DISPENSE ST ATION 2 DISPENSE ST ATION 1 DISPENSE ST ATION 2 DISPENSE YEL YEL W HI /V I O RECIR.
28 1. Install door cover by first plugging the door harness connector into the machine harness connector located at the bottom of the machine door . 2. Install door cover . 3. Secure the door cover using 5 screws provided. 4. Place refrigeration switch in the OFF po- sition.
Ein wichtiger Punkt beim Kauf des Geräts Bunn JDF-4S (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bunn JDF-4S noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bunn JDF-4S - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bunn JDF-4S reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bunn JDF-4S erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bunn JDF-4S besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bunn JDF-4S verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bunn JDF-4S. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bunn JDF-4S gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.