A. Power adapter B. Power adapter plug C. Power adapter socket D. Rotational speed regulator/rotational direction regulator E. Rotational speed indicator F. Foot pedal LED G. Hand piece holder H. Foot pedal connection I. Hand piece connection J. Hand piece K. Collet chuck L. Clamping device M. Unlocking device N. Power plug O. Foot pedal on/off function (optional accessory)
O

DESCRIPTION OF THE UNIT Please keep this user manual in a safe place!
Please read the user manual thoroughly before using the appliance for the first time. Many thanks for purchasing the Promed 1030 manicure device. This device was especially designed and manufactured to ensure the quality of treatment and may be used by both qualified personnel and private individuals after reading these instructions. This device is only suitable for manicure use (e.g. cuticle care, nail care, etc.). The device is also suitable for working in the field of nail technique and nail design as well as handling all materials used in this field such as gel and acrylic.
We, as the manufacturer, cannot be made liable in any way for injury or damages to people or objects that arise from failure to comply with this warning.
We wish you a lot of enjoyment with your new Promed 1030 unit. We would like to familiarize you with the unit in the following sections. Please read the user manual thoroughly before using the unit for the first time.

The rotational speed must be reduced to zero before changing the abrasive wheel. The device switches itself off in the event of non-compliance (SAFETY STOP).
Changing the abrasive wheel 1. Turn the clamping device (L) to the left. It must audibly click / snap into place two (2) times. The collet opens. 2. The abrasive wheel can be changed. 3. Afterwards, turn the clamping device (L) to the right. It must audibly click / snap into place two (2) times. The collet closes and thereby secures the abrasive wheel. Start the device again for operation.
2-3 mm

Please pay attention to the following before first time operation: Never place the unit in direct contact with fire, gas, oxygen or hot objects such as hot plates.
in any other way. G. If problems do arise with the handpiece, take it immediately to get it repaired. H. Do not lubricate or wash the handpiece. I. Do not switch the unit on while the chuck is opened. J. Place the test grinding head in the chuck when storing the handpiece. K. For indoor use only. L. Scrupulous supervision is required when the device is being used in the vicinity of children. M. Never extend the hand piece or foot pedal cable. N. The device may only be used with the power adapter supplied.


Scope of delivery: 1x Device 1030 (item 201001) 1x Handpiece MR10 (item 201004) 1x Power adapter (item 290426) 1x Instructions
Optional accessories: A foot pedal (Product No. 290004) with an ON/OFF function is available as an accessory.
Before you switch the unit on, you must set the rotating speed (rotary knob (D)) to zero.
A. Insert the power adapter (A) into the power socket and the power adapter plug (B), on the
back of the device, into the provided power adapter socket (C). B. Insert the plug of the handpiece into the socket (I) on the right side of the device. C. Select a suitable grinding head. Insert the abrasive wheel in the front on the hand piece
into the abrasive wheel mount (K) and lock the collet.Never use force to remove or insert a grinding head! Grinding heads with a shaft diameter of 2.332 mm to 2.350 mm (0.091 to 0.093 inches) fit exactly into the grinding head holder without you having to use excessive force. To remove a grinding head, switch off the device with the rotation switch (D) (middle position), making sure that the rotation switch (D) clearly locks into place. Now remove the abrasive wheel after opening the collet. D. Control of the rotation direction and speed: 1. Selection of the rotation direction: You make this selection by turning the rotation switch (D) to the left or right. Counterclockwise: The abrasive wheel turns to the left. Clockwise: The abrasive wheel turns to the right. 2. Choice of rotational speed: The speed is regulated by turning the rotation switch (D) to the left or to the right. The more you turn, the higher the rotationspeed.

3. Rotational speed indicator: The rotational speed indicator (E) is on the left next to the rotational speed regulator/ rotational direction regulator (D). This indicates the selected rotational speed by means of 5 LEDs. The device functions with maximum rotational speed when all LEDs light up. E. Before the first use, make sure that you let the handpiece run for about 30 minutes at approx. 16.000 rpm (2 LED lights of the speed indicator (E) should flash). This is necessary to bed in the carbon brushes of the motor. F. Use of foot pedal (optional accessory):
Set the rotational speed regulator (D) on “zero” (middle position). Connect the foot pedal (O) to the socket (H). The foot pedal LED (F) lights up yellow if the foot pedal is correctly connected. The running direction and rotational speed are set by turning the rotational speed regulator/rotational direction regulator (D). The device is now in standby mode. Turn the device on by pressing the foot pedal. The abrasive wheel starts to rotate in the direction and rotational speed you selected. You switch into the standby mode by pressing the foot pedal again.

ASC (Automatic Speed Control) = digital load compensation control: The electronic system registers the pressure on the abrasive wheel when grinding and compensates the loss of rotational speed. Maximum power is always available to you.
All-in-One control knob: Select running direction and rotational speed with one regulator at the same time through the simplest operation.
Safety Stop: If the device develops excessive speed and pressure during grinding, the electronics will respond by switching off the device. In this case, you must set the rotation switch (D) of the device to zero (middle position) and start the device again.
To ensure that the safety, reliability and performance of the unit are not adversely affected, enhancements, readjustments, alterations or repairs are not permitted aside from those performed by Promed authorized persons.
A. Keep the inner parts of the handpiece as free as possible from dust and grinding residue. B. Remove dirt from the outer surface of the handpiece with a cloth moistened with alcohol.
Prevent moisture from entering the unit. C. Only use grinding heads with a dental standard size of 2.332 - 2.350 mm (0.091 - 0.093
inches) and avoid using rusted or damaged grinding heads. Their false usage may lead to excessive wear and tear in the ball bearings. Adhere to the safe speed and the safety measures stipulated by the manufacturer. D. Do not expose the handpiece to strong knocks as this may damage the ball bearings. If the
handpiece should fall down, check whether the grinding head is bent. Pay closer attention to noise and/or heat generation. Send the handpiece immediately in for repair should it be damaged. E. Before cleaning the unit, make sure that it is turned off and disconnected from the electricity. F. Do not use any aggressive substances such as scouring agents or other detergents as they
may corrode the surface. G. Never immerse the device in a liquid and keep it away from liquids containing solvent or
acetone.

Your customers will definitely be expecting you to deliver a professional result. This is only possible with an appliance that is neither defect nor damaged. Therefore, take advantage of our service and have your appliance regularly examined by our specialists. Send in your appliance to Customer Service every 12 months at the latest. We can give you an estimate of the cost (total cost: 19.00 € net) that will be accounted for during the service of the device (total cost: 29.00 € net + material costs).
Power tools, accessories, and packaging should be recycled in an environmentally suitable manner. Only for EU countries: Do not dispose of power tools with the domestic waste! In accordance with the European Directive 2012/19/EU on waste electrical and electronic equipment and its implementation into national law, nonfunctioning power tools must be collected separately and recycled in an environmentally suitable manner. This symbol indicates that disposal of this product in the domestic waste is not permitted within the EU. Waste devices contain valuable recyclable material that should be recycled. Recycling also prevents uncontrolled waste disposal from damaging the environment and human health. Therefore, please dispose of all waste devices in the appropriate collection systems or send the device to the place where you bought the device for disposal. They will then recycle the device.


In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.