72 Battery Operated 4-Wire Operation Millivolt Compatible Digital Display DC V oltage Comp atible S tage: 1-Heat, 1-Cool Easy Slide Switch Operation USERS INFORMA TION MANUAL MODEL TST ATBBNQ001 NON-PROGRAMMABLE DIGIT AL THERMOST AT NOTE TO INST ALLER: This manual must be left with the equipment user .
P age 1 Ta ble Of Content s LOCA TION OF CONTROLS DISPLAY NORMAL OPERA TION PREP ARA TION REMOVE OLD THERMOSTA T WIRE CONNECTIONS JUMPER CONFIGURA TION TEST OPERA TION TROUBLESHOOTING W ARRANTY 2 4 5 .
TST A TBBNQ001 Safety W arnings P age 2 CAUTION Follow Installation Instructions carefully . DISCONNECT POWER T O THE HEA TER - AIR CONDITIONER BEFORE REMOVING THE OLD THERMOST A T AND INST ALLING THE NEW THERMOST A T . W ARNING The 2 Alkaline “AA” batteries must be replaced at least every 12 months to assure proper operation.
Location of Controls P age 3 MODE SWITCH Heat, Cool or Off On or Auto FAN SWIT CH UP & DOWN BUTTONS 72.
Display P age 4 Current room temperature. If the Up or Down arrow buttons are pressed the thermostat will show the desired Set T emp temperature indicator . Once this screen is reached you may use the Up or Down arrow buttons to adjust the desired room temperature.
P age 5 Normal Operation Manual Operation Select heat or cool with the mode switch. Normally leave the fan switched to auto. In fan auto, the fan will turn on only with a heat or cool demand. When Fan On is selected, the fan will run continuously , even when the mode switch is set to Off .
Step #1 Prep aration P age 6 These tools will be required: Flat Blade Screwdriver Wire cutter & S tripper Make sure your Heater/Air Conditioner is working properly before beginning installation of the thermost at. Carefully unpack the thermost at.
P age 7 Step #2 Remove & Replace Old Thermost at Remove the cover of the old thermostat. If it does not come off easily check for screws. Loosen the screws holding the thermostat base or subbase to the wall, and lift away . Disconnect the wires from the old thermostat.
P age 8 The top of the thermostat housing has two (2) screw- driver slots to assist when seperating. Repeat the procedure in the other screw driver slot. Separate the housing halves by pulling the top forward until the pins release, and then lift the bottom out.
P age 9 Battery Replacement REPLACE WITH A LKALINE BA TTERIES A T LEAST ONCE EVER Y YEAR, OR WHEN THE “LOW BA TTER Y” ICON APPEARS (pages 2,8). USE “ AA ” SIZE ALKALINE BA TTERIES USE “ AA .
72 Heat Off Cool Fan On FanA uto If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below , or the wiring diagrams that follow . Wire from the old thermostat terminal marked Function Install on the new thermostat connector marked Y1 or Y Cooling Y Power Rh, R, M, V r , A R B B Rev .
Sample Wiring Diagrams FA N COOLING POWER W G R Y W Y B O G R 4 Wire, 1 St age Cooling, 1 Stage Gas Heat Residential Gas or Electric Heat * , Electric Cool, split systems & package units P age 11 GAS OR ELECTRIC HEA T 4 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment.
P age 12 Sample Wiring Diagrams 4 Wire, 1 St age Cooling, 1 Stage Heat-Heat Pump with O reversing valve*. Residential Heat Pumps, split systems & package units, with no auxiliary heat. FA N POWER G R COMPRESSOR Y W Y B O G R REVERSING V AL VE O * For Heat Pump or Electric Heat applications see page 17 or 18 for Jumper configuration.
P age 13 Sample Wiring Diagrams 4 Wire, 1 St age Cooling, 1 Stage Heat-Heat Pump with B reversing valve*. Residential Heat Pumps, split systems & package units, with no auxiliary heat. FA N POWER G R COMPRESSOR Y W Y B O G R REVERSING V AL VE B * For Heat Pump or Electric Heat applications see page 17 or 18 for Jumper configuration.
P age 14 Sample Wiring Diagrams FA N POWER G R W W Y B O G R 3 Wire, 1 St age Heat Residential Gas or Electric Heat units with a separately controlled fan. GAS OR ELECTRIC HEA T 3 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment.
P age 15 Sample Wiring Diagrams POWER W R W Y B O G R 2 Wire, 1 St age Gas Heat Residential Gas or Millivolt units. GAS OR ELECTRIC HEA T 2 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment.
P age 16 Sample Wiring Diagrams FA N COOLING POWER G R Y W Y B O G R 3 Wire, 1 St age Cooling Residential Electric Cool units 3 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment.
P age 17 Step #5 Jumper Configuration FAN W/ HEA T HEA T PUMP 1 2 3 1 2 3 J1 J2 Jumper and Jumper are shown in the factory default positions for typical gas furnace heating with electric cooling.
P age 18 Step #5 Jumper Configuration FAN W/ HEA T HEA T PUMP 1 2 3 1 2 3 J1 J2 Jumper is used to select Fan On (G) with Heat (W). Jumper shown in the factory default position.
P age 19 Step #5 Jumper Configuration FAN W/ HEA T HEA T PUMP 1 2 3 1 2 3 J1 J2 Jumper and Jumper are used to select heat pump operation. Note: Thermost at Does Not Have Auxiliary Heat / Emergency Heat Capability . Leave jumpers in original factory default positions (figure-A) for non heat pump applications.
P age 20 Step #5 T est Operation Adjust the Slide Switch until it is located under the word HEA T on the thermostat. Press the Up or Down buttons until the set temperature is 10 degrees above room temperature. The HV AC unit should energize in the heating mode (pages 4-5).
P age 21 T roubleshooting SYMPTOM: The slide switches on the thermostat are very difficult to move. CAUSE: The backplate of the thermost at is deformed by being screwed tightly into a wall that is not perfectly flat. REMEDY : Loosen the screws holding the thermostat into the wall.
P age 22 T roubleshooting 4Z95 72 Heat Off Cool Fan On FanA uto C c F FOR HOME OR OFFICE USE T ested to Comply with FCC S tandards Battery S tat TST A TBBNQ001 SYMPTOM: The heating does not attempt to turn on. CAUSE: The heating setpoint is set too low or the Mode Switch is not set for Heat, or the batteries are too weak.
THIS WARRANTY DOES NOT INCL UDE LABOR OR OTHER COSTS incurred for diagnosing, repairing, removing, installing, shipping , servicing or handling of either defective parts or replacement parts. Such costs may be covered by a separate warranty provided by the installer .
Ein wichtiger Punkt beim Kauf des Geräts Bryant TSTATBBNQ001 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bryant TSTATBBNQ001 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bryant TSTATBBNQ001 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bryant TSTATBBNQ001 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bryant TSTATBBNQ001 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bryant TSTATBBNQ001 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bryant TSTATBBNQ001 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bryant TSTATBBNQ001. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bryant TSTATBBNQ001 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.