Instal la tio n Instructio ns T6- - P AC , T6- - PHP , T6 - - NAC, T6 - - NHP PREF ERR ED t SER IES AC / HP TH ERMOS T A T A07045 A07044 Pr ogr amma bl e Con trol Non - - - P rog ra mmab le C ont rol NOTE : Read the en tire in structio n manu al b efo re starting the in stallatio n.
2 T ABLE OF CONTEN TS P AGE SAFETY CONSIDERA TIONS 2 .................................... INTRODUCTI ON 3 .............................................. INST ALLA TION CONSID ERA TIONS 4 .............................. INST ALLA TION 7 ................
3 INTRO DUCTIO N Brya nt’ s 7- -day , 5/ 2 - - day , 1 - - day pr ogra mmabl e and non- -progra mmabl e Preferred t Ser ies Ther mosta t Control i s a wal l - -mounte d, low- -volta ge cont rol whic h combi nes te mpe rat ure a nd humidi ty cont rol in ei the r a si ngle unit or a two - - piece u n it.
4 INST ALLA TION CONSIDERA TIONS Power This cont rol i s powe red by 24V AC onl y . It r equi res 24V AC ( Rh a nd/or Rc a nd C te rmi nals ) of the low- -volt age t ra nsfor mer t o be connec te d to it f or prope r oper at ion. I t wil l not oper at e without t hes e 2 conne cti ons.
5 A07052 Fig. 1 - - PCB Bre akout Jumper Mod els Ther e ar e progra mmabl e and non - -progra mmabl e model s for al l appl ic ati ons. They ca n be conf igur ed for AC or H P ins ta lla tions , all owing i t to be use d in pla ce of a ll Brya nt ther most ats .
6 dedi ca ted s ens or wir es ma y be used f or its c onnect ion. De ta il s a re pr ovide d in se nsor i nstr ucti ons. Remote Ind oor T e mperature S ensor A rem ote te mper atur e se nsor may be us.
7 INST ALLA TION Car ton conta ins t he fol lowi ng compone nts . See Fi g. 2 for progr amma ble mode ls or Fig. 3 for non- -progra mmabl e model s. A07756 Fig. 2 - - T6 - - P AC / T6- - PHP Carton Content s 1. Dis pla y Module 2. Sta nd - -off f or Equipme nt Control M odule 3.
8 A07757 Fig. 3 - - T6 - - NAC / T6 - - NHP Ca rt on Conte nts 1. Dis pla y Module 2. Sta nd - -off f or Equipme nt Control M odule 3. S crews and p ig tail 4. Equipme nt Contr ol Module AC /HP Cont ro l Location AC/ HP Contr ol shoul d be mount ed: S Approxi mat el y 5 ft (1.
9 AC/ HP Contr ol shoul d NOT be mount ed: S Clos e t o a w indow , on a n outsi de wa ll, or ne xt to a door l ea ding t o the outs ide . S Expose d to dire ct l ight or hea t fr om a la mp, sun, fi re pl ace, or o th er temp eratu re- - rad iatin g o bjects w h ich co uld cause a false read ing .
10 UNIT DAMAGE HAZARD Failu re to follo w this cautio n may resu lt in equ ipm en t d amag e or im prope r oper ati on. Imp rop er wiring o r in stallation m ay damag e AC/HP Co ntro l. Ch eck to mak e su re wirin g is co rrect befo re pro ceed in g with ins ta ll at ion or t urni ng on power .
11 ENVIRONMENT AL HAZARD Failu re to follow th is cautio n may resu lt in env iron men tal dam age. Mercu ry i s a hazar dous was te . Fede ral r egula ti ons requi re tha t Me rcur y be di spos ed of prope rl y .
12 A07225 Fig. 4 - - Pr es s T abs to Rem ove Backpl ate A07226 Fig. 5 - - T ake Apart.
13 2. Route wi re s thr ough la r ge hole in mounti ng base . Leve l mounti ng bas e aga ins t wal l (for a es thet ic va lue onl y—Dis pla y Modul e need not be lev- el ed f or prope r ope ra ti on) a nd mar k wal l t hrough 2 mount ing hole s. See Fig.
14 6. Match an d co nn ect equ ip men t wires to pro per termin als of each c onne ct or bloc k bei ng ca re ful not to over ti ghte n the s cre ws. Corre ct polar ity m ust be obse rve d when conne ct ing the t wo wir es fr om the Equi pment Contr ol Modul e to the t herm osta t mounti ng bas e.
15 A07166 Fig . 8 - - S ecu r e Wir es to T erm in al S trip A07167 Fig. 9 - - Connec t Pigt ail W ir es to Di splay M odule.
16 NOTE : The 2- - wir e pigta il is not i nte nded to suppor t the we ight of the Us er Interface. D o no t h ang the U ser In terface from the eq u ipm en t C o nt rol M odule screw termin als. S Red is V+ S Black is V g 7. P ush an y ex cess wire into wall and ag ain st mou n ting b ase.
17 10. Find s uita ble indoor mounti ng loc at ion f or Equi pment Cont rol Modul e, ei the r nea r or on equipm ent. Se e Fig. 1 1. IM POR T ANT NOTE: Equipment C ontr ol Modul e should not be mount ed to duct wor k or below any othe r contr ols or equipm ent (i .
18 A07227 Fig. 12 - - Standoff 12 . Match an d con n ect equ ipm en t wires to prop er termin als of each c onne ct or bloc k bei ng ca re ful not to over ti ghte n the s cre ws. Corre ct polar ity m ust be obse rve d when conne ct ing the t wo wir es fr om the Equi pment Contr ol Modul e to the t herm osta t mounti ng bas e.
19 A07218 Fig. 13 - - Cover on Equipme nt Contr ol Module 14. T urn on powe r t o equipm ent . On powe r up, a ll displ ay s egme nts wil l li ght for 5 sec . For the next 5 se c a 2 - -digit c ode appea rs on lar ge di spla y whic h ide nti fie s AC/ HP Control c onfi gura ti on.
20 wa ll ( for ae st het ic val ue onl y - - Equipme nt Contr ol Modul e need not be le vel ed f or pr oper ope ra tion) and m ark wa ll thr ough 2 mounti ng hole s. 2. Drill tw o 3 /16 - - in . mo un tin g h o les in w all wh ere mark ed . Th ermo stat may be m ounted t o a st anda rd junc tion box i f desi re d.
21 5. Match an d co nn ect equ ip men t wires to pro per termin als of each c onne ct or bloc k. 6. Push a ny exc ess wi re i nto wa ll and aga ins t Equi pment C ontr ol Module . Seal h o le in w all to p rev ent air leak s. L eak s can affect op eratio n and cau se inco rrect tem peratu re an d/ or h u mid ity measu remen t.
22 9. T urn on powe r t o equipm ent . On powe r up, a ll displ ay s egme nts wil l li ght for 5 sec . For the next 5 se c a 2 - -digit c ode appea rs on lar ge di spla y whic h ide nti fie s AC/ HP Control c onfi gura ti on. Ref er to Opt ion 33. a. AC — 1 - - st age a ir c ondit ione r , AC, HP b.
23 Opti on 07 — Zoning Op tio n 08 — A ux iliary Heat Lo c kout T empe rat ure Se ttin g (o nly ava il abl e whe n hea t pump is used a nd when outdoor a ir te mper at ure se nsor i s pres ent ) O.
24 Opti on 31* — Dayli ght Savings T ime Conf igura tion (pr ogra mma ble mode ls only) Op tio n 3 2 — F urn ace Heat Stag ing Op tio n 3 3 — Sin g le or T w o - - P iece Installatio n Op tio n 99 — R eset to Factory D efaults TO ENTER CONFI GURA TION MODE Pre ss a nd hold F AN butt on for a pproxi mate ly 10 se c.
25 AC model — Ra nge: AC, H , C. HP — opera te s a s ingl e- -spe ed hea t pump wi th a fa n coi l. AC — oper ate s a si ngle- -spe ed AC. H — ope ra te s a heat- - only sys te m. Furna ce or fa n coil onl y; no outdoor unit . C — oper at es a c ool only- -syst em.
26 select OF F . S om e au xiliary h eaters req ui re separate G sig nal to tu rn o n blow er . In this case, select On . Defau lt is OF (o ff). Opt ion 05 — Room Air T em per atur e Sensi ng (pr ogrammabl e model s only) This s el ec ti on det er mines w hich s ens or the contr ol wil l use for me as uri ng room ai r te mpe rat ure .
27 OF (off) - - fu nctio n is d isab led. Au x iliary h eat is allow ed to o p erate when ever sufficient d eman d for h eat is av ailable. 5- -5 5 _ F - - Outdoor t empe ra tur e above w hich the a ux iliary h eat is no t allow ed to op erate (u nless M OD E is set to E mergen cy Heat).
28 progr amme d. Not ava ila ble wi th non - - progra mmabl e the rm ost at s or when the rmos tat i s conf igur ed as non- - progr amma ble . De fa ult is 90.
29 6 — The hea ti ng and c ooli ng output s wil l be ene rgi ze d no mor e t han 6 ti mes per hour . Whe n an out put i s e ner giz ed, i t wil l not be e ner giz ed a gain f or 10 mi nute s. Def ault is 4. Op tion 1 7 — Time Between E q uip men t Sta g es This s el ec ti on is only ava il able f or hea t pump sys te ms .
30 val ue be twee n 0 and 60 wil l be shown in t he m inute s dis play . Se e Ope rat iona l Info rm ation an d Wiring D iagram s fo r further exp lan ation o f d ry co ntact conf igur at ion a nd use.
31 Opt ion 21 — Keypad Loc kout (non- -pr ogrammabl e mode ls only) Th is selectio n allo ws th e in staller to limit access to th e k ey pad . S election s are O F (off), 1, 2 . OF (off) — T he u ser h as fu ll access to the k ey pad . 1 — Th e u ser has access t o ch an ge th e setp o int s.
32 4 — Peri ods W AKE, DA Y , EVE, and SLEEP are a vail abl e. Def ault is 4. Op tion 2 6 — Minim um C oo ling S etp oin t Th is selectio n allo ws th e in staller to co nfig u re the m in imu m co o ling setpo in t that the us er i s al lowe d to se t.
33 OF (off) — Th e H um idifier P ad Rem ind er is d isabled and w ill n ever be dis pla yed. 1- - 24 — The number of mont hs aft er whi ch the H umidif ier Pad Remi nder ic on wil l be displ ayed, “CHECK HUM P AD”.
34 Day ligh t Sav in gs Time by setting th e day o f th e week by selecting the appr opri at e tr ia ngle i con next t o the days of t he wee k, the mont h of t he year wi ll be se t in the cl ock hours l oca ti on (r ange 1- - 12) and the we ek of the mont h will be se t in the cl ock minut es loc at ion.
35 Op tion 9 9 — Reset to Fa cto ry Defa ults Use th is capab ility to reset the stat to “out o f the box” cond i tions . BEW ARE! All conf igur at ion s ett ings, progr am s ett ings, cl ock, a.
36 SYS TE M ST AR T - - UP AND CH ECK OUT Th e AC/ HP C on tro l is desig n ed with a b u ilt - - in in staller test cap ab ility. It allow s ea sy oper ati on of equi pment wi thout del ays or s etpoi nt adj ust ment s to forc e hea ti ng or c ooli ng.
37 TO TEST F AN Fan b u tton sw itches F A N icon b etween AU TO and On. Wh ile On is disp layed , G output wi ll be ene rgi ze d, tur ning fan on. Al low up to 10 sec a fte r button i s pre ss ed f or fa n t o tur n on a nd off . On s ome fa n coil s, fan c onti nues to oper at e for 90 sec a ft er G signa l is re moved.
38 If fixed temp eratures are desired, use SC HE DU LE b u tton to tu rn o n arro w ico n nex t to H OL D. T h is will main tain setpo in ts, n ot allow in g th em to ch an ge with progr amme d sc hedule . The F AN button ma y be use d to se le ct be twe en AUT O ( fan on only wi th equi pment ) and O n (f an on c ontinuous ly) f an mode s.
39 V acati on (pr ogrammable model s only) A vacatio n selection is availab le specifically fo r times wh ere the ho me w ill no t be oc cupi ed for an e xte nded pe riod. V ac at ion mode ha s a n aut omat ic hold, mean in g that setpo in ts are n ot affected by the p ro gram med sch ed ule.
40 Cy cle Timer Bas ed on t he se le ct ion of 2, 4, or 6 cyc le s per hour, t his t ime r is s et t o 30, 15, or 10 minute s. Thi s much tim e mus t el aps e from the st art of one cyc le be for e anot her c ycl e ca n sta rt . It ser ves t o im pose t he c ycle s per hour l im it s.
41 Th r ee- - Min u te Minim um o n Time In norm al ope ra tion, whe n a st age tur ns on, it wi ll not tur n of f for a mi nimum of 3 m inu tes. If th e setpo in t is chan g ed, th is tim er is can celed , allow in g th e equi pment to t urn of f i mmedi ate ly whe n the dema nd is re moved.
42 Pr ogramm able Fan (pr ogrammabl e model s only) The f an out put ca n be progra mme d bas ed on per iod of the da y . Whe n pro g ramm in g for each day an d p erio d the fan can be set to On or AU TO. Dry Contac t On the progr amma ble mode ls , the dr y cont act t hat c an be use d for c ontr ol of a n aux iliary d evice.
43 TROUBLESHOOTIN G If t he displ ay module doe sn’ t power up af ter power i s appl ie d, che ck the Rc/ Rh and C te rmi nal s for 24V AC. I f 24V AC is pres ent , chec k the volta ge betwe en Vg and V+. Thi s volt age wi ll be appr oxima tel y 12 - -20VDC.
44 T able 3 – Equipme nt Conf igur ation O utput s EQUIPMENT- CONFIGURA TION OPTION #1 HARDW ARE CONFIGURA TION COOL ST AGE 1 COOL ST AGE 2 HEA T ST AGE 1 HEA T ST AGE 2 HEA T ST AGE 3 EM HEA T ST A.
45 WIRING DIAG RAMS Display module Display module wall mount Equipment Control Module Fan Coil Heat Pump V+ V+ Vg Vg O O V+ V+ RVS/Heat Stage 2 O/B W 2 W3 W2 Vg Vg Heat Stage 1 W/W 1 W2 Compressor Y/Y.
46 Therm ostat Fan Coil Heat Pump OO RVS/Heat Stage 2 O/B W 2 W 3 W 2 Heat Stage 1 W /W 1 W 2 Compressor Y/Y 2 Y Y Not Used Y1 Fan G G 24VAC Hot Heating Rh R R 24VAC Hot Cooling R c Dry Contact 1 D1 D.
47 Therm ostat Fan Coil O RVS/Heat Stage 2 O/B W 2 W3 Heat Stage 1 W /W 1 W 2 Compressor Y/Y 2 Not Used Y1 Fan G G 24VAC Hot Heating Rh R 24VAC Hot Cooling Rc Dry Contact 1 D1 Dry Contact 2 D2 Aux.
48 Therm ostat Fan Coil Air Conditioner O RVS/Heat Stage 2 O/B W 2 W 3 Heat Stage 1 W /W 1 W 2 Compressor Y/Y 2 Y Y Not Used Y1 Fan G G 24VAC Hot Heating Rh R R 24VAC Hot Cooling R c Dry Contact 1 D1 .
49 Therm ostat Fan Coil O RVS/Heat Stage 2 O/B W 2 W 3 Heat Stage 1 W /W 1 W 2 Compressor Y/Y 2 Not Used Y1 Fan G G 24VAC Hot Heating Rh R 24VAC Hot Cooling Rc Dry Contact 1 D1 Dry Contact 2 D2 Aux.
50 Therm ostat Furnac e Air Conditioner Heat Stage 1 W /W 1 W Compressor Y/Y 2 Y Y Not Used Y1 Fan G G 24VAC Hot Heating Rh R R 24VAC Hot Cooling R c Dry Contact 1 D1 Dry Contact 2 D2 24VAC Common C COM COM Outdoor Ai r Temp OAT Remote Room Sensor RRS OAT/RRS Com OAT/RRS Outdoor Sensor * Remote Room Sensor * A07085 Fig.
51 Ther mosta t RVS/Heat Stage 2 O/B W 2 Heat Stage 1 W /W 1 Compressor Y/Y 2 Not Used Y1 Fan G G 24VAC Hot Heating Rh R 24VAC Hot Cooling Rc Dry Contact 1 D1 Dry Contact 2 D2 24VAC Comm on C C Humidify HUM Outdoor Air Tem p OAT Remote Room Sensor RRS OAT/RRS Com OAT/RRS A07086 Fig.
52 Therm ostat Furnace Air Conditioner W2 RVS/Heat Stage 2 O/B W 2 Heat Stage 1 W /W 1 W 1 Compressor Y/Y 2 Y Y Not Used Y1 Fan G G 24VAC Hot Heating Rh R R 24VAC Hot Cooling R c Dry Contact 1 D1 Dry .
53 Single-Stage Single-Stage Thermostat Furnace Air Conditioner RVS/Heat Stage 2 O/B W2 Heat Stage 1 W/W 1 W Compressor Low Y1 Compressor High Y/Y2 Y Y Fan G G 24VAC Hot Heating Rh R 24VAC Hot Cooling.
54 THE RMOS T A T CO NFIGURA TI ON RECO RD In staller _________________________ Model Number ______________________________ Date _________________________ A.
55 E Configur ation Opti ons Opt ion 01 _____ Equi pment Type Opt ion 02 _____ Cl ean Fi lt er T im er Adj ust ment Opt ion 03* _____ Fahr enheit / Cent igr ade Sel ect i on Opt ion 04 _____ Fan ( G) .
56 E Configura tion Options (c ont) Opt ion 21* _____ Keypad Lock out Opt ion 24* _____ Pr ogramm able/ Non - - Pr ogramm able ( progr ammabl e model s onl y) Opt ion 25* _____ Number of P rogr ammabl.
Ein wichtiger Punkt beim Kauf des Geräts Bryant T6--NAC (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bryant T6--NAC noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bryant T6--NAC - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bryant T6--NAC reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bryant T6--NAC erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bryant T6--NAC besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bryant T6--NAC verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bryant T6--NAC. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bryant T6--NAC gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.