1. Preface

* In order to provide our customers with quality, reliability and versatility, this product has been made to strict producing standards. This manual includes all necessary information about installation, debugging, discharging and maintenance. Please read this manual carefully before you open or maintain the unit. The manufacturer of this product will not be held

responsible if someone is injured or the uinit is damaged, as a result of improper installation, debugging or unnecessary maintenanc. It is vital that the instructions within this manual are adhere at all times. Only qualified person could install the unit.

* A qualified installer, centre, personnel or an authorized dealer, can only repair the unit.

* Maintenance and operation must be carried out according to the recommended time and frequency, as stated in this manual.

* Use genuine standard spare parts only. Failure to comply with these recommendations will void warranty.

* The swimming pool heat pump unit heats the swimming pool water and keeps the temperature constant.

Our heat pump has following characteristics:

Durable

The heating exchanger is made of PVC & Titanium tube, which can withstand prolonged exposure ot swimming pool water.

Easy operation The unit is very easy to operate: switch it on and set the desired pool water temperatue.

Quiet operation

The unit comprises an efficient rotary compressor and a low-noise fan motor, which guarantees its quiet operation. The unit can heat your swimming pool water when the air temperature is 10.C or higher.

Low cost The operational cost is very low due to its high performance

Page 3 of the Interline Heat Pump Compact (59695325) user manual — 2. Specifications
Seite 3 · Zum Vergrößern klicken
Seite 3

2. Specifications

2.1 Parameter of Swimming Pool Heat Pump Unit

Interline Heat Pump Compact (59695325) — 2. Specifications diagram (page 3)
Abb. 1 · 2. Specifications

Heating Capacity in A15/W26℃ Heating Capacity in A15/W26℃

Page 4 of the Interline Heat Pump Compact (59695325) user manual — 2.2 Dimension of swimming pool heat pump unit
Seite 4 · Zum Vergrößern klicken
Seite 4

2.2 Dimension of swimming pool heat pump unit

Interline Heat Pump Compact (59695325) — 2.2 Dimension of swimming pool heat pump unit diagram (page 4)
Abb. 2 · 2.2 Dimension of swimming pool heat pump unit
Interline Heat Pump Compact (59695325) — 2.2 Dimension of swimming pool heat pump unit diagram (page 4)
Abb. 3 · 2.2 Dimension of swimming pool heat pump unit
Interline Heat Pump Compact (59695325) — 2.2 Dimension of swimming pool heat pump unit diagram (page 4)
Abb. 4 · 2.2 Dimension of swimming pool heat pump unit
Page 5 of the Interline Heat Pump Compact (59695325) user manual — 3.2 How to close to the pool
Seite 5 · Zum Vergrößern klicken
Seite 5

3.Installation

The factory only provides the heat pump unit; the other items including an eventual bypass, in

the illustration are necessary parts for the water system, provided by users or the installers.

Please follow these steps when installing the heat pump:

1. All feeding of chemicals to the pool water has to be done downstream of the heat pump.
2. Install a bypass when the flow of the pool pump is more than 20% above the rated flow of the

heat exchanger of the heat pump.

3. Install the heat pump above the level of the pool water.
4. Install the heat pump on a solid foundation and use the damping rubbers to eliminate vibrations and noise.
5. Always keep the unit straight up. If the unit has been tilted or put on his side, allow 24h before starting the unit.

3.1 Heat pump location

The unit may be installed virtually anywhere outdoors. For indoor pools please consult your suppliers.

DO NOT put the unit in an enclosed area with a limited air volume where the unit discharge air will be re-

circulated. DO NOT put the unit next to shrubs, which can block the air inlet, Such locations deny a continuous

source of fresh air, which reduce its efficiency and may prevent adequate heat delivery.

The picture below give the minimum required distances from each side of the heat pump.

Interline Heat Pump Compact (59695325) — 3.1 Heat pump location diagram (page 5)
Abb. 5 · 3.1 Heat pump location
Interline Heat Pump Compact (59695325) — 3.1 Heat pump location diagram (page 5)
Abb. 6 · 3.1 Heat pump location

3.2 How to close to the pool

Install the heat pump as close to the swimming pool as possible to minimize the loss of heat through the piping. Put it on

a solid base and place the rubber blocks under the heat pump to eliminate vibrations.

Page 6 of the Interline Heat Pump Compact (59695325) user manual — 3.3 Distance from the pool
Seite 6 · Zum Vergrößern klicken
Seite 6

3.3 Distance from the pool

Normally, the pool heat pump is installed within a 7.5 meter radius of the pool. The greater the distance from the

pool, the greater the heat loss from the piping. Since the piping is buried for the most part, heat loss is minimal

for distances of up to 30 meters (15 meters to and from the pump= 30 meters total),unless the soil is wet or the water

level is high. Heat loss per 30 meters could roughly be estimated at 0.6kw-hour (2000 BTU) for every 5 ℃temperature

difference between the pool water and the soil surrounding the pipe,which translates to an operation time increase of

3-5%.

Interline Heat Pump Compact (59695325) — 3.3 Distance from the pool diagram (page 6)
Abb. 7 · 3.3 Distance from the pool
Page 7 of the Interline Heat Pump Compact (59695325) user manual — VALVE2–
Seite 7 · Zum Vergrößern klicken
Seite 7

3. 4 Pool system set up

Interline Heat Pump Compact (59695325) — 3. 4 Pool system set up diagram (page 7)
Abb. 8 · 3. 4 Pool system set up

3. 5 Connecting the by - pass (option)

Interline Heat Pump Compact (59695325) — 3. 5 Connecting the by - pass (option) diagram (page 7)
Abb. 9 · 3. 5 Connecting the by - pass (option)

VALVE1–

Slightly closed( water pressure increased

with just 100 to 200gr)

VALVE2–

VALVE3–

Setting the valve of the by-pass:

-Set all 3 valves entirely open

-Slightly close valve 1 ( see also 3.6)

-Close valve 3 about half way to adjust the refrigerant pressure

Completely open · Half way open

Page 8 of the Interline Heat Pump Compact (59695325) user manual — 3.7 Initial start-up
Seite 8 · Zum Vergrößern klicken
Seite 8

3.6 Electrical wiring

a separate circuit breaker(slow type-D curve)for the heat pump together with the proper wiring characteristics

(see table below). The current to the heat pump should only be applied when the filter pump is running. For

example a relay controlled by the filter pump could be used to activate the current to the heat pump. Further

connect the electrical supply to the junction box inside the unit. All PRO heat pumps require single-phase

connection.

Grounding the heat pump is required to protect you against electrical shock caused by an eventual short

circuit inside the unit.

The heat pump is not equipped with a flow switch or any other kind of water flow detection. Therefore, the

heat pump has to be wired electrically together with the filter pump to ensure water flow while the heat pump

is running.

3.7 Initial start-up

Start up procedure- after the installation is completed, you should follow these steps:

1. Turn on the filter pump, check for leaks and verify flow to and from the pool. 2. Turn on the electrical power supply to the unit, then press the ON/ OFF key on the electronic control panel. The unit should start when the time delay period has lapsed . 3. When the unit has been running for a couple of minutes, check if the air leaving the unit is cooler. 4. Check the performance of the flow switch as follows: with the unit running, turn the filter pump off. The unit should also switch off automatically. If not, the flow switch must be readjusted. 5. All the unit and filter pump to run 24 hours a day until the desired pool water temperature is reached.

When the set temperature is reached, the unit switches itself off. The unit will now automatically restart (as long as your filter pump is running) when the temperature of the pool water experiences a drop of more than 1℃ below set temperature. Depending on the starting temperature of the pool water and the air temperature, it can take several days for the water to reach the desired temperature. Covering the pool can drastically reduced this period.

Water flow switch—the unit is equipped with a flow switch that is switched on when enough water has flowed through the unit and that is switched off when the water flow becomes too low. (e.g. when

). the filter pump is switched off

Time delay—the unit is equipped with a built-in 3-minute start delay included to protect electrical

. components and contacts

After this time delay, the unit will automatically be restarted. Even a brief interruption of the power supply will activate the start delay and prevent the unit from starting immediately. Additional interruptions of the power supply during the delay period will have no effect on the 3- minute countdown.

3.3.8 9 Condensation When the swimming pool water is being heated by the heat pump, the incoming air is cooled down quite a bit, which can cause condensation on the fins of the evaporator. Condensed volumes can attain severa l litres per hour underhigh atmospheric humidity. Sometimes, this is wrongfully interpreted as a water leak.

Page 9 of the Interline Heat Pump Compact (59695325) user manual — 4.3 Spring startup
Seite 9 · Zum Vergrößern klicken
Seite 9

4. Guidelines

4.1 Water chemistry

Special attention should be paid to the chemical balance of the pool water. The pool water values should always stay within the following limits:

Important: failure to comply with these limits will invalidate the warranty. Note: exceeding one or several limits can damage the heat pump beyond repair. Always install water treatment equipment past the heat pump's water outlet, especially if the chemicals are automatically added to the water. A check-valve should also be installed between the outlet of the heat pump and this equipment in order to prevent products from flowing back into the heat pump if the filter pump stops.

4.2 Winterizing

The heat pump, filter pump, filter and conduits must be protected in areas where the temperature can drop below the freezing point, Evacuate all water from the heat pump as follows:

1. Turn off the electrical power supply to the heat pump 2. Close the water supply to the heat pump: completely close valves 2 and 3 of the by-pass 3. Disconnect the water inlet and outlet coupler fittings of the heat pump and let the water drain out of the unit

4.3 Spring startup

If your heat pump has been winterized, perform the following steps when starting the system in the spring:

1. Inspect the system for any debris or structural poroblems.
2. Connect the water inlet and outlet unions firmly.
3. Turn on the filter pump to supply water to the heat pump. Adjust the by-pass to allow water flow

through the heat pump.

4. Turn on the electrical power to the heat pump at the main breaker panel.
Show 6 more labels / short text on this page
Max · Min · pH · Free chlorine(mg/1) · TAC(mg/1) · Salt(g/1)
Page 10 of the Interline Heat Pump Compact (59695325) user manual — 4.4 Owner inspection
Seite 10 · Zum Vergrößern klicken
Seite 10

4.4 Owner inspection

The heat pumps are designed and constructed to provide long performance life when installed and operated properly under normal conditions. Periodic inspection are important to keep your heat pump running safe and efficiently all the years.

The following basic guidelines are suggested for your inspection:

1. Make sure the front of the unit is accessible for future service.
2. Keep the surrounding areas of the heat pump clear of all debris.
3. Keep all plants and shrubs trimmed and away from the heat pump.
4. Keep lawn sprinkler heads from spraying on the heat pump to prevent corrosion and damage.
5. If the unit is installed under a very sharp roof pitch or under a roof without a gutter, a gutter or diverter

should be fitted to prevent excessive water from pouring down onto the unit.

6. Do not use the heat pump if any parts has been under water. Immediately call a qualified professional

technician to inspect the heat pump and replace any part of the control system, which has be submerged.

The heat pump will produce condensation(water) while in operation. The heat pump base is designed to

allow the condensation to exit through the bottom drain port. The condensation will increase as the outdoor

air humidity level increase. Check the following at regular intervals to ensure proper condensate drainage:

1. Visually inspect and clear the bottom drain port of any debris that could clog the port.
2. Keep the air intake area and discharge area clear of debris so the airflow through the heat pump is

not restricted. The cooler discharge air should not accumulate and be drawn into the side air intake

coils.

During normal operation, the heat pump produces ten to twenty liters of condensate per hour. If condensate

drainage is above this range during operation or if water continues to drain from the base when the heat

pump is not in operation for more than an hour, a leak in the internal plumbing may have occurred. Call a

qualified heat pump technician to investigate the problem.

shut off the unit and keep the pool pump running. If the water stops running out of the base pan, it is

condensation water.

AN EVEN QUICKER WAY TEST THE DRAIN WATER FOR CHLORINE--if there is no chlorine

present, then it’s condensation.

Page 11 of the Interline Heat Pump Compact (59695325) user manual — 1 . Standby status :
Seite 11 · Zum Vergrößern klicken
Seite 11

5.1 Setting step

1 . Standby status :

Press M 10 seconds, get a sound “B” ,LCD display will show “0" “27”.

Press M again “1” “27”. Press , to enter heating temperature setting, press or

to alter heating temperature Press . again to confirm.

Press M again “8” “1”.Press , to enter Mode setting, press or to alter. Press

again to confirm.

Press M again “9” “0” Press , to enter water pump setting, press or to alter.

Press again to confirm.

Press M again “A”,“40” Press to enter return water temperature setting, press or

to alter. Press again to confirm.

Press M again “B” “5” Press , to enter Overheat protection (heating mode) setting,

press or to alter. Press again to confirm.

Press M again “B” “35” Press , to enter Electronic expansion valve setting, press

or to alter. Press again to confirm.

Press M again “E” “40” Press , to enter Max. temperature setting, press or to

alter Press . again to confirm.

Press M again “G” “8” Press , to enter Ambient temperature protection setting, press

or to alter. Press again to confirm.

Page 12 of the Interline Heat Pump Compact (59695325) user manual — AUX
Seite 12 · Zum Vergrößern klicken
Seite 12

5.2 The functions of controller display

Stand by status The LCD display shows the

room temperature and the

current mode.

IN SET VALVE OUT ROOM NO.

ROOM

MIN TEMP

h MIN

h

HUM

%

%

C F C F

FAN

AUTO

ON

OFF

Press to turn on and turn off the units.

Press button to change modes press 10S to set operation parameter under stand by status,or check the operation parameter under running or stand by status.

M Press button 5S to set clock.

SET Press 5S to set Timer ON/OFF

Setting operation parameter

Under standby status,press M button 10s to enter Operation Parameter setting interface;

Press M again to start setting (parameter from 00-D,see the Operation Parameter Table);

Under parameter setting,press or to set data;

Please note no motion on the display for 10s,the LCD will display water-in/water out temp.(under running)or

ambient temp.(under standby status)

Under running status,you can press M 10 to check current parameter,but can not change data of parameter!

Remarks:Standby status means the unit is connected with electricity but not running.

NO.

NO.

VALVE NO.

NO.

Parameter 08 Mode1(cooling&heating) 2auxiliary elec heating (cooling+heating) 3(heating only)

Parameter 01 to set inlet water temp.under heating mode (15-40 )default setting:40

0 long time working for water pump 1 water pump turns off after the whole unit power off for 30s initialization 0

AUX

" ".

Show 8 more labels / short text on this page
Initialisation · " " · " " · " ” · s · " " · ℃ ℃ · " "
Page 13 of the Interline Heat Pump Compact (59695325) user manual — How to know the current status
Seite 13 · Zum Vergrößern klicken
Seite 13

How to know the current status

Interline Heat Pump Compact (59695325) — How to know the current status diagram (page 13)
Abb. 10 · How to know the current status
Interline Heat Pump Compact (59695325) — How to know the current status diagram (page 13)
Abb. 11 · How to know the current status

Under running status ,press “M” 10 seconds to check the current status of the unit!You can check water-in/water out temp,condenser temp and ambient temp,please note no

motion on the display for 10s,the LCD w1il5l display water-in/water out temp/(under running)or ambient temp.(unit stops)

Page 14 of the Interline Heat Pump Compact (59695325) user manual — E
Seite 14 · Zum Vergrößern klicken
Seite 14

5.3 Operation data setting table:

Electronic expansion valve mode 0(Manul)/1(AUTO)

Automatic restarting after power off

Water pump keep running or stop

after compressor stop for 30s

A

Electronic expansion valve manual steps 10~50

E

Maximum temperature setting 30-70℃ 40℃

F DeltaT setting 1-20℃ 2℃

G Ambient temp. protection(Min.) -15℃-15℃ 8℃

Show 6 more labels / short text on this page
1(record) · 3(hot water) 0-3 · 0(keep running) · /1(stop) · 8-60℃ · 40℃
Page 15 of the Interline Heat Pump Compact (59695325) user manual — EE 05
Seite 15 · Zum Vergrößern klicken
Seite 15

6. Maintenance and Inspection

6.1 Maintenance

To check the water supply device and the releaser often. You should avoid the condition of no water or air enter into system, or that will influence unit's performance and reliability. You should clear the water filter regularly to avoid unit's damage by filter's jam.

There should be dry, sanitary and ventilation around the units. To clean the side heating exchanger regularly for keeping good heating exchanging and saving energy.

To check the operation of every process in the u nit, the operation pressure of the refrigerant system. You should maintain or change it in time.

To check the power supply and cable connection often, there is abnormal action or bad smell about the electrical component. If there is, please maintain or change it in time.

Please discharge all water in the water pump and water system lest freeze the water pump or water system. You should discharge the water at the bottom of water pump if the units will stop for long time. And you should check the units thoroughly and fill the system with water fully before power on the units again.

6.2 Trouble shooting guide

Water in temp. Sensor failure

The sensor is open or short circuit

Check or replace a new sensor

PP 01

Water out temp. Sensor failure

The sensor is open or short circuit

Check or replace a new sensor

PP 02

The sensor is open or short circuit Check or replace a new sensor

Coil1 sensor failure(Heating mode)

PP 03

Gas return sensor failure The sensor is open or short circuit Check or replace the sensor

PP 04

Ambient sensor failure The sensor is open or short circuit

PP 05

Check or replace the sensor

Temp. is too much different between water-in and water-out

PP 06

Water volume isn’t enough

Check pressure gauge,increase the

EE 01

Refrigerant system pressure is high

Refrigerant system pressure is low

Check pressure gauge,refeed refrigerant

E E02

EE 03

No water/little water in water system.

Check the water flow volume, water pump is failure or not

3times display PP06 (

Temp. is too much different between water-in&out)

Water flow volume not enough, water pressure difference is too low

Check the water flow volume, or water system is jammed or not

EE 05

EE 08

Wire controller and The PCB connection failure Check the wire connection

Show 10 more labels / short text on this page
malfunction Controller display · Reason · resolution · Increase water volume · High pressure protection · water volume · Low pressure protection · Flow switch failure · in 30minutes · Communication failure
Page 16 of the Interline Heat Pump Compact (59695325) user manual — 7. Wiring diagram
Seite 16 · Zum Vergrößern klicken
Seite 16

7. Wiring diagram

Interline Heat Pump Compact (59695325) — 7. Wiring diagram diagram (page 16)
Abb. 12 · 7. Wiring diagram
Page 17 of the Interline Heat Pump Compact (59695325) user manual — CAUTION
Seite 17 · Zum Vergrößern klicken
Seite 17
Interline Heat Pump Compact (59695325) — Meanings of symbols displayed on heat pump unit diagram (page 17)
Abb. 13 · Meanings of symbols displayed on heat pump unit

Meanings of symbols displayed on heat pump unit

This unit uses a flammable refrigerant (R32). If refrigerant leaks and comes in contact with fire or heating part, it will create harmful gas and there is risk of fire.

WARNING

Read the OPERATING INSTRUCTIONS carefully before operation.

Service personnel are reguired to carefully read the OPERATING INSTRUCTIONS and INSTALLATION MANUAL before operation.

Further information is available in the OPERATING INSTRUCTIONS, INSTALLATION MANUAL, and the like.

  • Since rotating parts and parts which could cause an electric shock are used

in this product, be sure to read these “Safety Precautions” before use.

  • Since the cautionary items shown here are important for safety, be sure to observe them.
  • After reading this manual, keep it together with the installation manual in a

handy place for easy reference.

  • Be sure to receive a guarantee card from your dealer and check that the

purchased data and shop name, etc. are entered correctly.

Marks and their meanings

Incorrect handling could cause serious hazard, such as death, serious injury, etc. with a high probability.

WARNING

Incorrect handling could cause serious hazard depending on the conditions.

CAUTION

Meanings of symbols used in this manual

: Be sure not to do.

: Be sure to follow the instruction.

: Never insert your finger or stick, etc.

: Never step onto the indoor/outdoor unit and do not put anything on them.

: Danger of electric shock. Be careful.

: Be sure to disconnect the power supply plug from the power outlet.

: Be sure to shut off the power.

: Risk of fire.

Page 18 of the Interline Heat Pump Compact (59695325) user manual — Meanings of symbols displayed on heat pump unit
Seite 18 · Zum Vergrößern klicken
Seite 18

Do not connect the power cord to an intermediate point, use an extension cord, or connect multiple devices to heat pump.

  • This may cause overheating, fire, or electric shock. Make sure the power plug is free of dirt and insert it securely into the outlet.
  • A dirty plug may cause fire or electric shock. Do not bundle, pull, damage, or modify the power cord, and do not apply heat or place heavy objects on it.
  • This may cause fire or electric shock. Do not turn the breaker OFF/ON or disconnect/connect the power plug during operation.
  • This may create sparks, which can cause fire. Do not expose your body directly to cool air for a prolonged length of time.
  • This could be detrimental to your health. The unit should not be installed, relocated, disassembled, altered, or repaired by the user.
  • An improperly handled heat pump may cause fire, electric shock, injury, or water leakage, etc. Consult your dealer.
  • If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent in order to avoid a hazard.
  • When installing, relocating, or servicing the unit, make sure that no substance other than the specified refrigerant (R32) enters the refrigerant circuit.
  • Any presence of foreign substance such as air can cause abnormal pressure rise and may result in explosion or injury.
  • The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction, or unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater). Do not insert your finger, a stick, or other objects into the air inlet or outlet.
  • This may cause injury, since the fan inside rotates at high speeds during operation. In case of an abnormal condition (such as a burning smell), stop the heat pump and disconnect the power plug or turn the breaker OFF.
  • A continued operation in the abnormal state may cause a malfunction, fire, or electric shock. In this case, consult your dealer. When the heat pump does not cool or heat, there is a possibility of refrigerant leakage. If any refrigerant leakage is found, stop operations and ventilate the room well and consult your dealer immediately. If a repair involves recharging the unit with refrigerant, ask the service technician for details.
  • The refrigerant used in the heat pump is not harmful. Normally, it does not leak. However, if refrigerant leaks and comes in contact with fire or heating part of such a fan heater, kerosene heater, or cooking stove, it will create harmful gas and there is risk of fire.
Page 19 of the Interline Heat Pump Compact (59695325) user manual — Meanings of symbols displayed on heat pump unit
Seite 19 · Zum Vergrößern klicken
Seite 19
  • The user should never attempt to wash the inside of the indoor unit. Should the inside of the unit require cleaning, contact your dealer.
  • Unsuitable detergent may cause damage to plastic material inside the unit, which may result in water leakage. Should detergent come in contact with electrical parts or the motor, it will result in a malfunction, smoke, or fire.
  • The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
  • Be aware that refrigerants may not contain an odour.
  • Do not use means to accelerate the defrosting process or to clean the appliance, other than those recommended by the manufacturer.
  • Do not pierce or burn. This unit should be installed outdoor or in rooms which exceed the floor space specified below. GL50 : 2.2 m2 or larger GL60 : 2.3 m2 or larger GL71/80: 3.1 m2 or larger

Do not touch the air inlet or the aluminum fins of the heat pump unit

  • This may cause injury.

Do not use insecticides or flammable sprays on the unit.

  • This may cause a fire or deformation of the unit.

Do not expose pets or houseplants to direct airflow.

  • This may cause injury to the pets or plants.

Do not place other electric appliances or furniture under the heat pump unit.

  • Water may drip down from the unit, which may cause damage or malfunction.

Do not leave the unit on a damaged installation stand.

  • The unit may fall and cause injury.

Do not step on an unstable bench to operate or clean the unit.

  • This may cause injury if you fall down.

Do not pull the power cord.

  • This may cause a portion of the core wire to break, which may cause overheating or fire.

Do not charge or disassemble the batteries, and do not throw them into a fire.

  • This may cause the batteries to leak, or cause a fire or explosion.

Do not use the unit for special purposes, such as storing food,

raising animals, growing plants, or preserving precision devices or art objects.

  • This may cause deterioration of quality, or harm to animals and plants.

Do not expose combustion appliances to direct airflow.

  • This may cause incomplete combustion.

Before cleaning the unit, switch it OFF and disconnect the power

plug or turn the breaker OFF.

  • This may cause injury, since the fan inside rotates at high speeds during operation.

When the unit will be unused for a long time, disconnect the

power plug or turn the breaker OFF.

  • The unit may accumulate dirt, which may cause overheating or fire.

Ensure that the area is well-ventilated when the unit is operated

together with a combustion appliance.

  • Inadequate ventilation may cause oxygen starvation.

After the heat pump is used for several seasons, perform

inspection and maintenance in addition to normal cleaning.

  • Dirt or dust in the unit may create an unpleasant odor, contribute

to growth of fungi, such as mold, or clog the drain passage, and

cause water to leak from the indoor unit. Consult your dealer for

inspection and maintenance, which require specialized knowledge and skills.

Page 20 of the Interline Heat Pump Compact (59695325) user manual — Meanings of symbols displayed on heat pump unit
Seite 20 · Zum Vergrößern klicken
Seite 20

Do not operate switches with wet hands.

  • This may cause electric shock.

Do not clean the heat pump with water or place an object that

contains water, such as a flower vase, on it.

  • This may cause fire or electric shock.

Do not step on or place any object on the unit.

  • This may cause injury if you or the object falls down.

Dirty filters cause condensation in the heat pump which will contribute

to the growth of fungi such as mold.

It is therefore recommended to filters every 2 weeks.

Consult your dealer for installing the heat pump.

  • It should not be installed by the user since installation requires specialized knowledge and skills.

An improperly installed heat pump may cause water leakage, fire, or electric shock.

Provide a dedicated power supply for the heat pump.

  • A non-dedicated power supply may cause overheating or fire.

Do not install the unit where flammable gas could leak.

  • If gas leaks and accumulates around the unit, it may cause an explosion.

Earth the unit correctly.

  • Do not connect the earth wire to a gas pipe, water pipe, lightning

rod, or a telephone ground wire. Improper earthing may cause electric shock.

Install an earth leakage breaker depending on the installation

location of the heat pump (such as highly humid areas).

  • If an earth leakage breaker is not installed, it may cause electric shock.

Ensure that the drain water is properly drained.

  • If the drain passage is improper, water may drip down from the

unit, wetting and damaging the furniture.

Please prepare the professional tools for R32 refrigerant heat pump before you do maintenance.

Interline Heat Pump Compact (59695325) — Meanings of symbols displayed on heat pump unit diagram (page 20)
Abb. 14 · Meanings of symbols displayed on heat pump unit
Show 6 more labels / short text on this page
Explosion · Anti- static gloves · R32 leak · -proof vacuum · detector · pump
Display-Codes

Fehlercodes

Was die auf dem Display angezeigten Fehlercodes bedeuten und wie man sie behebt.

CodeBedeutungLösung
GL502.2 m2 or larger p.19
GL602.3 m2 or larger p.19
Reparatur

Fehlerbehebung

Häufige Probleme, wahrscheinliche Ursachen und Lösungen.

ProblemMögliche UrsacheAbhilfe
Water in temp. Sensor failureThe sensor is open or short circuitCheck or replace a new sensor p.15
Water out temp. Sensor failureThe sensor is open or short circuitCheck or replace a new sensor p.15
Coil1 sensor failure(Heating mode)The sensor is open or short circuitCheck or replace a new sensor p.15
Gas return sensor failureThe sensor is open or short circuitCheck or replace the sensor p.15
Ambient sensor failureThe sensor is open or short circuitCheck or replace the sensor p.15
Temp. is too much different between water-in and water-outWater volume isn’t enoughIncrease water volume p.15
High pressure protectionRefrigerant system pressure is highCheck pressure gauge,increase the water volume p.15
Low pressure protectionRefrigerant system pressure is lowCheck pressure gauge,refeed refrigerant p.15
Flow switch failureNo water/little water in water system.Check the water flow volume, water pump is failure or not p.15
3times display PP06 (Temp. is too much different between water-in&out)in 30minutesWater flow volume not enough, water pressure difference is too lowCheck the water flow volume, or water system is jammed or not p.15
Communication failureWire controller and The PCB connection failureCheck the wire connection p.15
This unit should be installed outdoor or in rooms which exceed the floor space specified below. GL50 : 2.2 m2 or larger GL60 : 2.3 m2 or larger GL71/80: 3.1 m2 or larger p.19

Frage zu Interline Heat Pump Compact (59695325) stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Interline Heat Pump Compact (59695325)

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Interline Heat Pump Compact (59695325) PDF-Anleitung

81 Seiten·5.1 MB·Heizgerät·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…