* In order to provide our customers with quality, reliability and versatility, this product has been made to strict producing standards. This manual includes all necessary information about installation, debugging, discharging and maintenance. Please read this manual carefully before you open or maintain the unit. The manufacturer of this product will not be held
responsible if someone is injured or the uinit is damaged, as a result of improper installation, debugging or unnecessary maintenanc. It is vital that the instructions within this manual are adhere at all times. Only qualified person could install the unit.
* A qualified installer, centre, personnel or an authorized dealer, can only repair the unit.
* Maintenance and operation must be carried out according to the recommended time and frequency, as stated in this manual.
* Use genuine standard spare parts only. Failure to comply with these recommendations will void warranty.
* The swimming pool heat pump unit heats the swimming pool water and keeps the temperature constant.
Durable
The heating exchanger is made of PVC & Titanium tube, which can withstand prolonged exposure ot swimming pool water.
Easy operation The unit is very easy to operate: switch it on and set the desired pool water temperatue.
The unit comprises an efficient rotary compressor and a low-noise fan motor, which guarantees its quiet operation. The unit can heat your swimming pool water when the air temperature is 10.C or higher.
Low cost The operational cost is very low due to its high performance

2.1 Parameter of Swimming Pool Heat Pump Unit

Heating Capacity in A15/W26℃ Heating Capacity in A15/W26℃





The factory only provides the heat pump unit; the other items including an eventual bypass, in
the illustration are necessary parts for the water system, provided by users or the installers.
Please follow these steps when installing the heat pump:
heat exchanger of the heat pump.
The unit may be installed virtually anywhere outdoors. For indoor pools please consult your suppliers.
DO NOT put the unit in an enclosed area with a limited air volume where the unit discharge air will be re-
circulated. DO NOT put the unit next to shrubs, which can block the air inlet, Such locations deny a continuous
source of fresh air, which reduce its efficiency and may prevent adequate heat delivery.
The picture below give the minimum required distances from each side of the heat pump.


Install the heat pump as close to the swimming pool as possible to minimize the loss of heat through the piping. Put it on
a solid base and place the rubber blocks under the heat pump to eliminate vibrations.

Normally, the pool heat pump is installed within a 7.5 meter radius of the pool. The greater the distance from the
pool, the greater the heat loss from the piping. Since the piping is buried for the most part, heat loss is minimal
for distances of up to 30 meters (15 meters to and from the pump= 30 meters total),unless the soil is wet or the water
level is high. Heat loss per 30 meters could roughly be estimated at 0.6kw-hour (2000 BTU) for every 5 ℃temperature
difference between the pool water and the soil surrounding the pipe,which translates to an operation time increase of
3-5%.




Slightly closed( water pressure increased
with just 100 to 200gr)
VALVE3–
Setting the valve of the by-pass:
-Set all 3 valves entirely open
-Slightly close valve 1 ( see also 3.6)
-Close valve 3 about half way to adjust the refrigerant pressure
Completely open · Half way open

a separate circuit breaker(slow type-D curve)for the heat pump together with the proper wiring characteristics
(see table below). The current to the heat pump should only be applied when the filter pump is running. For
example a relay controlled by the filter pump could be used to activate the current to the heat pump. Further
connect the electrical supply to the junction box inside the unit. All PRO heat pumps require single-phase
connection.
Grounding the heat pump is required to protect you against electrical shock caused by an eventual short
circuit inside the unit.
The heat pump is not equipped with a flow switch or any other kind of water flow detection. Therefore, the
heat pump has to be wired electrically together with the filter pump to ensure water flow while the heat pump
is running.
Start up procedure- after the installation is completed, you should follow these steps:
1. Turn on the filter pump, check for leaks and verify flow to and from the pool. 2. Turn on the electrical power supply to the unit, then press the ON/ OFF key on the electronic control panel. The unit should start when the time delay period has lapsed . 3. When the unit has been running for a couple of minutes, check if the air leaving the unit is cooler. 4. Check the performance of the flow switch as follows: with the unit running, turn the filter pump off. The unit should also switch off automatically. If not, the flow switch must be readjusted. 5. All the unit and filter pump to run 24 hours a day until the desired pool water temperature is reached.
When the set temperature is reached, the unit switches itself off. The unit will now automatically restart (as long as your filter pump is running) when the temperature of the pool water experiences a drop of more than 1℃ below set temperature. Depending on the starting temperature of the pool water and the air temperature, it can take several days for the water to reach the desired temperature. Covering the pool can drastically reduced this period.
Water flow switch—the unit is equipped with a flow switch that is switched on when enough water has flowed through the unit and that is switched off when the water flow becomes too low. (e.g. when
). the filter pump is switched off
Time delay—the unit is equipped with a built-in 3-minute start delay included to protect electrical
. components and contacts
After this time delay, the unit will automatically be restarted. Even a brief interruption of the power supply will activate the start delay and prevent the unit from starting immediately. Additional interruptions of the power supply during the delay period will have no effect on the 3- minute countdown.
3.3.8 9 Condensation When the swimming pool water is being heated by the heat pump, the incoming air is cooled down quite a bit, which can cause condensation on the fins of the evaporator. Condensed volumes can attain severa l litres per hour underhigh atmospheric humidity. Sometimes, this is wrongfully interpreted as a water leak.

4.1 Water chemistry
Special attention should be paid to the chemical balance of the pool water. The pool water values should always stay within the following limits:
Important: failure to comply with these limits will invalidate the warranty. Note: exceeding one or several limits can damage the heat pump beyond repair. Always install water treatment equipment past the heat pump's water outlet, especially if the chemicals are automatically added to the water. A check-valve should also be installed between the outlet of the heat pump and this equipment in order to prevent products from flowing back into the heat pump if the filter pump stops.
The heat pump, filter pump, filter and conduits must be protected in areas where the temperature can drop below the freezing point, Evacuate all water from the heat pump as follows:
If your heat pump has been winterized, perform the following steps when starting the system in the spring:
through the heat pump.

The heat pumps are designed and constructed to provide long performance life when installed and operated properly under normal conditions. Periodic inspection are important to keep your heat pump running safe and efficiently all the years.
The following basic guidelines are suggested for your inspection:
should be fitted to prevent excessive water from pouring down onto the unit.
technician to inspect the heat pump and replace any part of the control system, which has be submerged.
The heat pump will produce condensation(water) while in operation. The heat pump base is designed to
allow the condensation to exit through the bottom drain port. The condensation will increase as the outdoor
air humidity level increase. Check the following at regular intervals to ensure proper condensate drainage:
not restricted. The cooler discharge air should not accumulate and be drawn into the side air intake
coils.
During normal operation, the heat pump produces ten to twenty liters of condensate per hour. If condensate
drainage is above this range during operation or if water continues to drain from the base when the heat
pump is not in operation for more than an hour, a leak in the internal plumbing may have occurred. Call a
qualified heat pump technician to investigate the problem.
shut off the unit and keep the pool pump running. If the water stops running out of the base pan, it is
condensation water.
AN EVEN QUICKER WAY TEST THE DRAIN WATER FOR CHLORINE--if there is no chlorine
present, then it’s condensation.

Press M 10 seconds, get a sound “B” ,LCD display will show “0" “27”.
Press M again “1” “27”. Press , to enter heating temperature setting, press or
to alter heating temperature Press . again to confirm.
Press M again “8” “1”.Press , to enter Mode setting, press or to alter. Press
again to confirm.
Press M again “9” “0” Press , to enter water pump setting, press or to alter.
Press again to confirm.
Press M again “A”,“40” Press to enter return water temperature setting, press or
to alter. Press again to confirm.
Press M again “B” “5” Press , to enter Overheat protection (heating mode) setting,
press or to alter. Press again to confirm.
Press M again “B” “35” Press , to enter Electronic expansion valve setting, press
or to alter. Press again to confirm.
Press M again “E” “40” Press , to enter Max. temperature setting, press or to
alter Press . again to confirm.
Press M again “G” “8” Press , to enter Ambient temperature protection setting, press
or to alter. Press again to confirm.

Stand by status The LCD display shows the
room temperature and the
current mode.
IN SET VALVE OUT ROOM NO.
MIN TEMP
h MIN
h
HUM
%
%
C F C F
FAN
AUTO
ON
OFF
Press to turn on and turn off the units.
Press button to change modes press 10S to set operation parameter under stand by status,or check the operation parameter under running or stand by status.
M Press button 5S to set clock.
SET Press 5S to set Timer ON/OFF
Setting operation parameter
Under standby status,press M button 10s to enter Operation Parameter setting interface;
Press M again to start setting (parameter from 00-D,see the Operation Parameter Table);
Under parameter setting,press or to set data;
Please note no motion on the display for 10s,the LCD will display water-in/water out temp.(under running)or
ambient temp.(under standby status)
Under running status,you can press M 10 to check current parameter,but can not change data of parameter!
Remarks:Standby status means the unit is connected with electricity but not running.
NO.
NO.
VALVE NO.
NO.
Parameter 01 to set inlet water temp.under heating mode (15-40 )default setting:40
0 long time working for water pump 1 water pump turns off after the whole unit power off for 30s initialization 0
" ".



Under running status ,press “M” 10 seconds to check the current status of the unit!You can check water-in/water out temp,condenser temp and ambient temp,please note no
motion on the display for 10s,the LCD w1il5l display water-in/water out temp/(under running)or ambient temp.(unit stops)

Electronic expansion valve mode 0(Manul)/1(AUTO)
Automatic restarting after power off
Water pump keep running or stop
after compressor stop for 30s
Electronic expansion valve manual steps 10~50
Maximum temperature setting 30-70℃ 40℃
F DeltaT setting 1-20℃ 2℃
G Ambient temp. protection(Min.) -15℃-15℃ 8℃

6.1 Maintenance
To check the water supply device and the releaser often. You should avoid the condition of no water or air enter into system, or that will influence unit's performance and reliability. You should clear the water filter regularly to avoid unit's damage by filter's jam.
There should be dry, sanitary and ventilation around the units. To clean the side heating exchanger regularly for keeping good heating exchanging and saving energy.
To check the operation of every process in the u nit, the operation pressure of the refrigerant system. You should maintain or change it in time.
To check the power supply and cable connection often, there is abnormal action or bad smell about the electrical component. If there is, please maintain or change it in time.
Please discharge all water in the water pump and water system lest freeze the water pump or water system. You should discharge the water at the bottom of water pump if the units will stop for long time. And you should check the units thoroughly and fill the system with water fully before power on the units again.
Water in temp. Sensor failure
The sensor is open or short circuit
Check or replace a new sensor
Water out temp. Sensor failure
The sensor is open or short circuit
Check or replace a new sensor
The sensor is open or short circuit Check or replace a new sensor
Coil1 sensor failure(Heating mode)
Gas return sensor failure The sensor is open or short circuit Check or replace the sensor
Ambient sensor failure The sensor is open or short circuit
Check or replace the sensor
Temp. is too much different between water-in and water-out
Water volume isn’t enough
Check pressure gauge,increase the
Refrigerant system pressure is high
Refrigerant system pressure is low
Check pressure gauge,refeed refrigerant
EE 03
No water/little water in water system.
Check the water flow volume, water pump is failure or not
3times display PP06 (
Temp. is too much different between water-in&out)
Water flow volume not enough, water pressure difference is too low
Check the water flow volume, or water system is jammed or not
EE 08
Wire controller and The PCB connection failure Check the wire connection




This unit uses a flammable refrigerant (R32). If refrigerant leaks and comes in contact with fire or heating part, it will create harmful gas and there is risk of fire.
Read the OPERATING INSTRUCTIONS carefully before operation.
Service personnel are reguired to carefully read the OPERATING INSTRUCTIONS and INSTALLATION MANUAL before operation.
Further information is available in the OPERATING INSTRUCTIONS, INSTALLATION MANUAL, and the like.
in this product, be sure to read these “Safety Precautions” before use.
handy place for easy reference.
purchased data and shop name, etc. are entered correctly.
Incorrect handling could cause serious hazard, such as death, serious injury, etc. with a high probability.
Incorrect handling could cause serious hazard depending on the conditions.
Meanings of symbols used in this manual
: Be sure not to do.
: Be sure to follow the instruction.
: Never insert your finger or stick, etc.
: Never step onto the indoor/outdoor unit and do not put anything on them.
: Danger of electric shock. Be careful.
: Be sure to disconnect the power supply plug from the power outlet.
: Be sure to shut off the power.
: Risk of fire.

Do not connect the power cord to an intermediate point, use an extension cord, or connect multiple devices to heat pump.

Do not touch the air inlet or the aluminum fins of the heat pump unit
Do not use insecticides or flammable sprays on the unit.
Do not expose pets or houseplants to direct airflow.
Do not place other electric appliances or furniture under the heat pump unit.
Do not leave the unit on a damaged installation stand.
Do not step on an unstable bench to operate or clean the unit.
Do not pull the power cord.
Do not charge or disassemble the batteries, and do not throw them into a fire.
Do not use the unit for special purposes, such as storing food,
raising animals, growing plants, or preserving precision devices or art objects.
Do not expose combustion appliances to direct airflow.
Before cleaning the unit, switch it OFF and disconnect the power
plug or turn the breaker OFF.
When the unit will be unused for a long time, disconnect the
power plug or turn the breaker OFF.
Ensure that the area is well-ventilated when the unit is operated
together with a combustion appliance.
After the heat pump is used for several seasons, perform
inspection and maintenance in addition to normal cleaning.
to growth of fungi, such as mold, or clog the drain passage, and
cause water to leak from the indoor unit. Consult your dealer for
inspection and maintenance, which require specialized knowledge and skills.

Do not operate switches with wet hands.
Do not clean the heat pump with water or place an object that
contains water, such as a flower vase, on it.
Do not step on or place any object on the unit.
Dirty filters cause condensation in the heat pump which will contribute
to the growth of fungi such as mold.
It is therefore recommended to filters every 2 weeks.
Consult your dealer for installing the heat pump.
An improperly installed heat pump may cause water leakage, fire, or electric shock.
Provide a dedicated power supply for the heat pump.
Do not install the unit where flammable gas could leak.
Earth the unit correctly.
rod, or a telephone ground wire. Improper earthing may cause electric shock.
Install an earth leakage breaker depending on the installation
location of the heat pump (such as highly humid areas).
Ensure that the drain water is properly drained.
unit, wetting and damaging the furniture.
Please prepare the professional tools for R32 refrigerant heat pump before you do maintenance.

Häufige Probleme, wahrscheinliche Ursachen und Lösungen.
| Problem | Mögliche Ursache | Abhilfe | |
|---|---|---|---|
| Water in temp. Sensor failure | The sensor is open or short circuit | Check or replace a new sensor | p.15 |
| Water out temp. Sensor failure | The sensor is open or short circuit | Check or replace a new sensor | p.15 |
| Coil1 sensor failure(Heating mode) | The sensor is open or short circuit | Check or replace a new sensor | p.15 |
| Gas return sensor failure | The sensor is open or short circuit | Check or replace the sensor | p.15 |
| Ambient sensor failure | The sensor is open or short circuit | Check or replace the sensor | p.15 |
| Temp. is too much different between water-in and water-out | Water volume isn’t enough | Increase water volume | p.15 |
| High pressure protection | Refrigerant system pressure is high | Check pressure gauge,increase the water volume | p.15 |
| Low pressure protection | Refrigerant system pressure is low | Check pressure gauge,refeed refrigerant | p.15 |
| Flow switch failure | No water/little water in water system. | Check the water flow volume, water pump is failure or not | p.15 |
| 3times display PP06 (Temp. is too much different between water-in&out)in 30minutes | Water flow volume not enough, water pressure difference is too low | Check the water flow volume, or water system is jammed or not | p.15 |
| Communication failure | Wire controller and The PCB connection failure | Check the wire connection | p.15 |