Benutzeranleitung / Produktwartung LEGACY 569J des Produzenten Bryant
Zur Seite of 60
569J 60Hz AIR COOLED CONDENSING UNIT PURON r (R - - 410A) REFRIGERANT 6 T O 20 NOMINAL T ONS Pr oduct Data C09310 569J*07- - 14 shown the environmentally sound refrigerant Bryant’ s air-cooled ai r .
2 FEA TURES AND BENEFITS (cont.) Factory-installed options (FIOPs ) Certifi ed and pre - - enginee red fac tory-install ed options (FI OPs) allo w units to be ins talled in less time, ther eby reduci ng installe d cost.
3 FEA TURES AND BENEFITS (cont.) Coil flexibility Model 524J dire ct- e xpansion coi ls have galvani zed ste el casings; inl et and outle t c onnecti ons are on t he sa me end. The c oils are de signed for use with Puron (R - - 410A) refrigera nt and have 3 / 8 -in.
4 MODEL NUMBER NOMENCLA T URE 123456789 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 5 6 9 J E 1 4 A 0 0 0 G 0 0 A 0 A _____________ Model T ype 569J = B ryant C onden sing Unit Puron r R - - - 410A Refrigeran t V.
5 AHRI* CAP ACIT Y RA TI NGS UNI T C OOLING CIR CUITS CO MPR ESSORS NOM. CAP ACI TY (TON S) NET COOLING CAP ACI TY (MBH ) TOT AL POWE R (kW) EER IEER 569J* 07A/524J *07 116 71.0 6.2 11.5 12.2 569J* 08A/524J *08 1 1 7.5 92.0 8.2 11.2 11.8 569J* 12A/524J *12 1 1 10 117.
6 PHYS ICAL DA T A Sing le Circuit Models with NOVA TION - - - All Aluminum Coil Design 569J*07A 569J*08A 569J*12A 569J*14A 569J*16A Refrigeration Sy stem # Circuits / # Comp. / T ype 1/1/S c r o l l 1/1/S c r o l l 1/1/S c r o l l 1/1/S c r o l l 1/2/ S c r o l l R - - - 410A ch arge A /B (lbs) 4.
7 PHYS ICAL DA T A (CONT .) Dual C ircuit Models with NOV ATION - - - All Aluminum Coil Design 569J*12D 569J*14D 569J* 16D Refrigeration Sy stem # Circuits / # Comp. / T ype 2/2/ S c r o l l 2/2/ S c r o l l 2/2/ S c r o l l R - - - 410A ch arge A /B (lbs) 3.
8 DIMENSIONS C101212A 569J.
9 DIMENSIONS (cont .) C101213 569J.
10 DIMENSIONS (cont .) UNIT ELECTRICAL CHARACTERISTICS STD. UNIT WT. CORNER A CORNER B CORNER C CORNER D CENTER OF GRAVITY UNIT HEIGHT LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. X Y Z H 569JA25 (RTPF) 208/230-3-60,460-3-60,575-3-60 978 444 360 163 188 85 147 67 283 128 38 [965.
11 OPTIONS AND ACCESSORIES 569J* OPTI ONS AND ACCE SSO RIES ITE M OPTION* ACCESSORY† Di sco nnect Swi tch (no n-fuse d) } X Special - - - coated Coil Protection X Conven ience Outlet (115-v)** X Low.
12 OPTIONS AND ACCESSORIES (con t.) LOW AMBIENT CONTROL (F ACTORY -INST ALLED OR FIELD-INST ALLED) F ACTORY -INST ALLED CONVENIENCE OUTLE (powered and non-powered) T F ACTORY -INST ALLED DISCONNECT SW.
13 OPTIONS AND ACCESSORIES (con t.) Ove r head suspe nsio n packa ge includes neces sary bracke ts to support uni ts in hori zontal i nstalla tions. CO 2 sensors ca n be us e d in conjunction wit h the economizer access ory to he lp meet indoor ai r quality requirem ents.
14 OPTIONS AND ACCESSORIES (con t.) ECONOMIZER UV -C GERMICIDAL LAMPS DISCHARGE PLENUM RETURN-AIR GRILLE SUBBASE FA N COIL UNIT F AN COIL UNIT HOT W A TER OR STEAM COIL 524J WITH DISCHARGE PLENUM RETU.
15 SELECTION P ROCEDURE Combinat ion rati ngs for 569J* units matche d with 524J Series air handle rs a re in this book. If uni t is used with an air hand ler , use th e Bryan t Electron ic Catalog A HU (Air-H a ndling Unit) select ion program to obtai n combine d ratings.
16 TYPICAL WIRING SCHEMA TI C C09624 T ypical 569J*16 Single Circuit 569J.
17 TYPICAL WIRING SCHEMA TI C (cont .) C09627 T yp ical 569J*16 Dual Circuit 569J.
18 PERFORMANCE DA T A 569J*07A CONDENSE R ONL Y RA TINGS SST ( _ F) AIR TEM PERATU RE ENTERING C ONDENS ER ( _ F) 80 85 95 100 105 115 20 TC 46.7 45.1 41.7 39.8 37.9 33.9 kW 4.04 4.27 4.77 5.04 5.32 5.93 SDT 91.6 96.4 105.9 110.6 115.3 124.7 25 TC 51.
19 PERFORMANCE DA T A (cont .) 569J*12A CONDENSE R ONL Y RA TINGS SST ( _ F) AIR TEM PERATU RE ENTERING C ONDENS ER ( _ F) 80 85 95 100 105 115 20 TC 78.0 75.4 70.1 67.3 64.6 58.9 kW 6.03 6.44 7.31 7.76 8.23 9.21 SDT 94.0 98.7 108.2 113.0 117.7 127.2 25 TC 86.
20 PERFORMANCE DA T A (cont .) 569J*14A CONDENSE R ONL Y RA TINGS SST ( _ F) AIR TEM PERATU RE ENTERING C ONDENS ER ( _ F) 80 85 95 100 105 115 20 TC 100.8 97.4 90.3 86.6 83.0 75.5 kW 8.48 8.97 10.00 10.53 11.07 12.19 SDT 98.0 102.6 111.8 116.4 120.9 130.
21 PERFORMANCE DA T A (cont .) 569J*16A CONDENSE R ONL Y RA TINGS SST ( _ F) AIR TEM PERATU RE ENTERING C ONDENS ER ( _ F) 80 85 95 105 115 125 20 TC 125.5 121.8 114.2 106.6 99.7 79.7 kW 10.5 11.2 12.6 14.2 16.0 17.5 SDT 98.6 103.4 113.0 122.7 134.9 136.
22 PERFORMANCE DA T A (cont .) 569J*25A CONDENSE R ONL Y RA TINGS SST ( _ F) AIR TEM PERATU RE ENTERING C ONDENS ER ( _ F) 80 85 95 105 115 125 20 TC 159.2 154.5 144.5 133.9 122.5 110.2 kW 13.0 13.7 15.3 17.1 19.2 21.5 SDT 97.3 101.8 110.6 119.3 127.9 136.
23 PERFORMANCE DA T A (cont .) 569J*07A - - 524J*07 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (d b) EA (d b) EA (d b) EA ( db) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 1800 Cfm EA (w b) 58 THC 65.8 65.8 74.1 63.4 63.
24 PERFORMANCE DA T A (cont .) 569J*07A - - 524J*08 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (db ) EA (db ) EA (d b) EA (db ) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 2250 Cfm EA (w b) 58 THC 71.6 71.6 80.7 69.1 69.
25 PERFORMANCE DA T A (cont .) 569J*08A - - 524J*08 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA ( db) EA ( db) EA (d b) EA (d b) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 2250 Cfm EA (w b) 58 THC 84.6 84.6 95.4 81.7 81.
26 PERFORMANCE DA T A (cont .) 569J*08A - - 524J*12 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (db ) EA (db ) EA (d b) EA (db ) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 3000 Cfm EA (w b) 58 THC 93.7 93.7 105.5 90.3 90.
27 PERFORMANCE DA T A (cont .) 569J*12A - - 524J*12 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (db ) EA (d b) EA (db ) EA (db ) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 3000 Cfm EA (w b) 58 THC 110.5 110.5 121.5 106.
28 PERFORMANCE DA T A (cont .) 569J*12 A- - 524J*14 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (db ) EA (db ) EA (d b) EA (db ) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 3750 Cfm EA (w b) 58 THC 119.7 119.7 132.9 115.
29 PERFORMANCE DA T A (cont .) 569J*12D - - 524J*12 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (d b) EA (db ) EA (d b) EA (d b) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 3000 Cfm EA (w b) 58 THC 111.6 111.6 125.3 107.
30 PERFORMANCE DA T A (cont .) 569J*12D - - 524J*14 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (db ) EA (db ) EA (d b) EA (db ) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 3750 Cfm EA (w b) 58 THC 118.1 118.1 133.1 113.
31 PERFORMANCE DA T A (cont .) 569J*14A - - 524J*14 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (db ) EA (d b) EA (db ) EA (db ) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 3750 Cfm EA (w b) 58 THC 138.4 138.4 152.4 133.
32 PERFORMANCE DA T A (cont .) 569J*14A - - 524J*16 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (db ) EA (db ) EA (d b) EA (db ) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 4500 Cfm EA (w b) 58 THC 149.9 149.9 166.0 144.
33 PERFORMANCE DA T A (cont .) 569J*14D - - 524J*14 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (d b) EA (db ) EA (d b) EA (d b) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 3750 Cfm EA (w b) 58 THC 137.2 137.2 152.7 132.
34 PERFORMANCE DA T A (cont .) 569J*14D - - 524J*16 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (db ) EA (db ) EA (d b) EA (db ) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 4500 Cfm EA (w b) 58 THC 145.6 145.6 164.1 140.
35 PERFORMANCE DA T A (cont .) 569J*16A - - 524J*16 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (d b) EA (db ) EA (d b) EA (d b) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 4500 Cfm EA (w b) 58 THC 169.9 169.9 190.5 164.
36 PERFORMANCE DA T A (cont .) 569J*16A - - 524J*25 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (db ) EA (db ) EA (d b) EA (db ) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 6000 Cfm EA (w b) 58 THC 188.1 188.1 211.9 181.
37 PERFORMANCE DA T A (cont .) 569J*16D- - 524J*16 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (d b) EA (db ) EA (d b) EA (d b) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 4500 Cfm EA (w b) 58 THC 168.2 168.2 185.7 161.9 161.
38 PERFORMANCE DA T A (cont .) 569J*16D - - 524J*25 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (db ) EA (db ) EA (d b) EA (db ) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 6000 Cfm EA (w b) 58 THC 189.5 189.5 213.0 182.
39 PERFORMANCE DA T A (cont .) 569J*25A - - 524J*25 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (d b) EA (db ) EA (d b) EA (d b) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 6000 Cfm EA (w b) 58 THC 221.5 221.5 248.3 213.
40 PERFORMANCE DA T A (cont .) 569J*25A- - 524J*28 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (db ) EA (d b) EA (db ) EA (db ) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 7500 Cfm EA (w b) 58 THC 236.2 236.2 266.2 228.0 228.
41 PERFORMANCE DA T A (cont .) 569J*25D- - 524J*25 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (d b) EA (db ) EA (d b) EA (d b) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 6000 Cfm EA (w b) 58 THC 220.0 220.0 247.0 212.1 212.
42 PERFORMANCE DA T A (cont .) 569J*25D- - 524J*28 COMBINA TION RA TINGS AMBI ENT TEMPERA TURE 85 95 105 115 125 EA (d b) EA (d b) EA ( db ) EA (db ) EA ( db) 75 80 85 75 80 85 75 80 85 75 80 85 75 80 85 7500 Cfm EA (w b) 58 THC 237.5 237.5 261.6 228.
43 ELECTRICAL DA T A 569J*07A COOLING WIT HOUT POWER ED C ONVEN IENC E OUTLET V --- P h --- H z VOL TAGE RAN GE COMP 1 OFM (ea) POWER SUPPL Y MIN MAX RLA LRA WAT T S FLA MCA Fu se 208/230 - - - 3 - - - 60 187 253 19 123 325 1.5 26.8 45 4 6 0 --- 3 --- 6 0 414 506 9.
44 ELECTRICAL DA T A (cont .) 569J*12A COOLING WIT HOUT POWER ED C ONVEN IENC E OUTLET V --- P h --- H z VOL TAGE RAN GE COMP 1 OFM (ea) POWER SUPPL Y MIN MAX RLA LRA WAT T S FLA MCA Fu se 208/230 - - - 3 - - - 60 187 253 30.1 225 325 1.5 40.6 60 4 6 0 --- 3 --- 6 0 414 506 16.
45 ELECTRICAL DA T A (cont .) 569J*14A COOLING WIT HOUT POWER ED C ONVEN IENC E OUTLET V --- P h --- H z VOL TAGE RAN GE COMP 1 OFM (ea) POWER SUPPL Y MIN MAX RLA LRA WAT T S FLA MCA Fu se 208/230 - - - 3 - - - 60 187 253 48.1 245 325 1.5 63.1 80 4 6 0 --- 3 --- 6 0 414 506 18.
46 ELECTRICAL DA T A (cont .) 569J*16A COOLING WIT HOUT POWER ED C ONVEN IENC E OUTLET V --- P h --- H z VOL TAGE RAN GE COMP 1 COMP 2 OFM (ea) POWE R SUPPL Y MIN MAX RLA LRA RLA LRA WAT T S FLA MCA Fu se 208/230 - - - 3 - - - 60 187 253 25 164 25 164 325 1.
47 ELECTRICAL DA T A (cont .) 569J*25A COOLING WIT HOUT POWER ED C ONVEN IENC E OUTLET V --- P h --- H z VOL TAGE RAN GE COMP 1 COMP 2 OFM (ea) POWE R SUPPL Y MIN MAX RLA LRA RLA LRA WAT T S FLA MCA Fu se 208/230 - - - 3 - - - 60 187 253 30.1 225 30.1 225 325 1.
48 AP PLIC A TION DA T A Operating limits Maximum out door tempe rature 125 _ F ................ Minimum re turn-air t empera ture (524J) 55 _ F .......... Maximum re turn-air t empera ture (524J) 95 _ F .......... Rang e of acceptab le satur ation suctio n temperature 20 to 50 _ F .
49 569J* 07 - 14 P IPIN G RECOMMENDA TIONS (SINGLE- CIRCUIT U NI T) R - - - 410A Equivale nt Length Ft 0 --- 3 8 38 - - - 75 75 - - - 113 113 - - - 150 150 - - - 188 m 0 --- 1 2 12 - - - 23 23 - - - 3.
50 569J 16 - 25 P IPING RECOMMEN DA TIONS (SINGLE- C IRCUIT U NIT) R - 410A Equival ent Leng th Ft 0-38 38-75 75-113 113-150 150-188 m 0-12 12-23 23-34 34-46 46-57 Model Linea r Length Ft 0-25 25-50 5.
51 569J 12 - 14 P IPIN G RECOMMENDA TIONS ( TWO -CIRCUIT UNIT) NOT E: 569J requ ires TWO sets of refrigera tion piping R - - - 410A Equivale nt Length Ft 0 --- 3 8 38 - - - 75 75 - - - 113 113 - - - 1.
52 569J 16 - 25 P IPIN G RECOMMENDA TIONS ( TWO -CIRCUIT UNIT) NOT E : 569J req uires TWO sets of ref rigeration p iping R - 410A Equivalent Le ngth Ft 0-38 38-75 75-113 113-150 150-188 m 0-12 12-23 2.
53 TYPICAL PIPING AND WIRING Roof Installation and a Ceiling- - Mounted Fan Coil WEA THERPROOF FUSED DISCONNECT* PER NEC FIELD- SUPPLIED POWER INSULA TED V APOR LINE POWER WIRES CONTROL WIRES INDOOR T.
54 TYPICAL PIPING AND WIRING (CONT .) Roof Installation and a V ertical Discharge Fan Coil LEGEND *Field supplied. DIA M — Di amet er NEC — National Electr ical Code TXV — Therm ostatic Expansion V alve Piping NO TES: 1. All piping must f ollow standard refrigerant piping techniques.
55 TYPICAL PIPING AND WIRING (CONT .) Gr ound Level I nstallation and V ertical Discharge Fan Coil NO TES: 1. All piping must foll ow st andard refrigerant piping techniques. Ref er to System Design Manual for details. 2. All wiring must comply with the applicab le local and national codes.
56 TYPICAL PIPING AND WIRING (CONT .) Dual Condens ing Units and a Dual Cir cuit Fan RETURN AIR SUBBASE ACCESSORY 15 DIAM MIN 40RMQ024 UNIT ELECTRIC HEA TER ACCESSORY 24 V CONTROL WIRE BULB CAPILLARY .
57 GUI DE SPE CI FI CA T ION S Commer cial Air -Cooled Co ndensing U nits HV AC Guide Specifications Size Range : 6t o2 0T o n s ,N o m i n a l Bryant Model Numbers: 569J*, Single Circuit (07 - 25 Models) 569J*, Dual Circuit (12 - - 25 Models) Part 1 — Gen eral 1.
58 b. Eva porator coi ls shall be l eak te sted to 150 psig, pre ssure tested to 450 psig, and qual ified to UL 1995 burst test at 1775 psig. c. Conde nser coils shall be lea k tested t o 150 psig, pressure te sted to 650 psig, a nd qualifi ed to UL 1995 burst test at 1980 psig.
59 (5.) Reve rse Phase 3 fault c ode indica tion (6.) W el ded Contac tor fault c ode indic ation (7.) Low V oltage fa ult code indi cation (8.) Anti - - short cycle prote ction (9.) Phas e revers al protection 2. Min imum safety d evices w hich are equ ipped w ith automatic res et (after res etting first at thermos tat), shall in- clude : a.
60 Manufacturer reserves the right to discontinue, or change at any time, spe cifications or designs without notice and without incurring obligations. E 2011 Bryan t Heating & Cooling S ystems D 7310 W . Morris St. D In dianapolis, IN 46231 Printed in U .
Ein wichtiger Punkt beim Kauf des Geräts Bryant LEGACY 569J (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Bryant LEGACY 569J noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Bryant LEGACY 569J - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Bryant LEGACY 569J reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Bryant LEGACY 569J erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Bryant LEGACY 569J besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Bryant LEGACY 569J verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Bryant LEGACY 569J. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Bryant LEGACY 569J gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.