DCM4010FLEX

EN

Read First !

Safety Information !

To ensure safe operation and service of the meter, follow these instructions. Failure to observe warnings can result in severe Injury.

Warning !

Identify hazardous conditions and actions that could cause

BODILY HARM or DEATH

- Individual protective equipment should be used if HAZARDOUS LIVE parts in the installation where measurement is to be carried out could Be ACCESSIBLE. - If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. - To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. - Verify the Meter operation by measuring a known Current. If in doubt, have the Meter serviced. - Do not apply more than the rated voltage/Current, as marked on Meter. - To avoid false readings that can lead to electric shock and injury, replace battery as soon as low battery indicator. - Do not use Meter around explosive gas or vapor.

Flexible AC current probe

Do not touch the area above the LCD during measurement

- Do not use a flexible current sensor if the inner copper wire of the flexible cord is visible. - De-energize the installation under test or wear suitable protective clothing during fitting a removal of the Flexible Current Probe. - Do not apply around or remove from UNINSU LATED HAZARDOUS LIVE conductors, which may render electric shock, electric burn, or arc flash.

Caution !

Identify conditions and actions that could cause DAMAGE the meter or equipment under test. Do not expose Meter to extremes in tempera- ture of high humidity.

Page 3 of the KPS Flexible Current Probe Meter (DCM4010FLEX) user manual — Symbols as marked on the meter and Instruction card
Seite 3 · Zum Vergrößern klicken
Seite 3
KPS Flexible Current Probe Meter (DCM4010FLEX) — Symbols as marked on the meter and Instruction card diagram (page 3)
Abb. 2 · Symbols as marked on the meter and Instruction card

Symbols as marked on the meter and Instruction card

Do not apply to or remove from HAZARDOUS LIVE conductors.

The meter automatically turns the power off after powering up and no operation for 20 minutes ± 30 seconds.

Do not attempt to repair this Clamp Meter. It contains no user-serviceable parts. Repair or servicing should only be performed by qualified personnel.

Periodically wipe the case with a dry cloth and detergent. Do not use abrasives or solvents.

Press “Power” button, and during the LCD shows battery capacity, press “backlight” button until the LCD shows “AoFF” to disable Auto Power Off Function.

Page 4 of the KPS Flexible Current Probe Meter (DCM4010FLEX) user manual — Caution
Seite 4 · Zum Vergrößern klicken
Seite 4

DCM4010FLEX

EN

Backlight Environmental Specifications Indoor Use. Pollution Degree : 2 Maximum operating altitude : 2000m (6562 ft) Operating temperature & Relative Humidity : 0°C - 30°C, ≦80%RH 30°C - 40°C, ≦75%RH 40°C - 50°C, ≦45%RH Storage temperature : -20°C - 60°C, 0 to 80% RH (no batteries). Temperature coefficient : 0.2 x (Specified accuracy) / °C, < 18°C, > 28°C Shock vibration : Sinusoidal vibration MIL-PRF-28800F (5-55 Hz, 3g max.) Drop Protection : 4 feet drop to hardwood on concrete Floor

Data Hold Electrical Specifications Accuracy is given as ±(% of reading + counts of least significant digit) at 23°C ± 5°C, with relative humidity Less than 80% R.H. Accuracy is specified for a period of one year after calibration.

Position Error of Clamp : Accuracy and position error assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.

sFlex-10Error Distance from Optimum (mm)15±2.0% 25±2.5% 35±3.0%

Replacing Batteries AC Current

RangeOL ReadingResolutionAccuracy (45Hz~500Hz) 30.00A33.00A0.01A±(3.0% + 5D) 300.0A330.0A0.1A±(3.0% + 5D) 3000A3300A1A±(3.0% + 5D)

LCD displays 0 counts when the reading < 10 counts. Frequency Response : 45 - 500Hz (Sine Wave)

AC Function ACA specifications are ac coupled, true R.M.S. For non-sinusoidal waveforms, Additional Accuracy by Crest Factor (C.F.): Add 3.0% for C.F. 1.0 - 2.0. Add 5.0% for C.F. 2.0 - 2.5. Add 7.0% for C.F. 2.5 - 3.0.

Caution

Remove Meter from conductor and turn off power before opening the battery cover.

Page 5 of the KPS Flexible Current Probe Meter (DCM4010FLEX) user manual — EN61010-1, EN61010-2-032, EN61326-1
Seite 5 · Zum Vergrößern klicken
Seite 5

EN DCM4010FLEX

General Specifications

Display : 3000 counts.

Over range Display"OL"

Dimensions (W x H x D) :

10" coilApprox. 120mm x 280mm x 25mm

Weight(without Battery) :

10" coil170g
Power RequirementsAAA Size Battery x 2
Battery Life200 hours ALKALINE Battery

Low Batteries Indication :

Voltage drops below operating voltage,

will flash.

Maximum Conductor Sizecoil size

Safety Standard :

EN61010-1, EN61010-2-032, EN61326-1

CAT IV 600V, CAT III 1000V

Conversion Rate4 times/second

Frage zu KPS Flexible Current Probe Meter (DCM4010FLEX) stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu KPS Flexible Current Probe Meter (DCM4010FLEX)

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

KPS Flexible Current Probe Meter (DCM4010FLEX) PDF-Anleitung

22 Seiten·5.7 MB·Messwerkzeug·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…