Characteristics:

  • SMD CHIP MONO (white, neutral white, warm white, super warm white, ultra warm white) as well as RGB.
  • Power supply 24 VDC.
  • Homogenous light. No single points visible.
  • Safety class IP54. Suitable for wet room.
  • Operating temperature range -10° C till +45° C.
  • CE compliant with applicable European directives.

Safety indices: Be sure to have a qualified electrician complete installation. The customer is not entitled to claim for any lights installed without observing European safety directives. The manufacturer is then discharged from liability when damage is caused by improper use or installation. For indoor use only. Protection class IP40.

Preinstallation: Please follow the sequence of installation step by step. Non-observance can lead to damage of the flex strip.

1. Switch off the electricity at the mains before commencing installation or lamp change and (if a fuse box is installed) remove the appropriate circuit fuse to avoid accidental switching on of the mains supply. 2. Connect the flex strip to the power supply 24 VDC output (secondary side). 3. Connect connector (primary side) of power supply to mains (220-240VAC). 4. If a dimmer is used, than it must be placed between power supply and the flex strip.
Installation possibilites1. Please keep in mind, that following strain is not allowed:
PROLED Flex Strip Opal Berlin (L6OP004) — L6OPxxx diagram (page 1)
Abb. 1 · L6OPxxx

DO NOT PRESS DO NOT TWIST DO NOT STRETCH

2. Minimum bending diameter at FLEX STRIP OPAL LONDON, LIVERPOOL & MILAN Light output 8mm
PROLED Flex Strip Opal Berlin (L6OP004) — L6OPxxx diagram (page 1)
Abb. 2 · L6OPxxx

NOT ALLOWED

3. Minimum bending diameter at FLEX STRIP OPAL BERLIN, HAMBURG & SIDE VIEW
PROLED Flex Strip Opal Berlin (L6OP004) — NOT ALLOWED diagram (page 1)
Abb. 3

NOT ALLOWED

MBN GmbH, Balthasar-Schaller-Str. 3, 86316 Friedberg - Germany

www.proled.com

Page 2 of the PROLED Flex Strip Opal Berlin (L6OP004) user manual — L6OPxxx
Seite 2 · Zum Vergrößern klicken
Seite 2

Montageanleitung / Installation manual

Installation1. Installation with short profiles
PROLED Flex Strip Opal Berlin (L6OP004) — L6OPxxx diagram (page 2)
Abb. 4 · L6OPxxx

Short fixing profiles must be in level. It is recommended to use at least two short fixing profiles each meter.

2. Procedure during mounting and demounting
PROLED Flex Strip Opal Berlin (L6OP004) — L6OPxxx diagram (page 2)
Abb. 5 · L6OPxxx

Simultaneously install from Installation from one side Min. 2 Persons needed at both ends is not allowed a length of more than 2m.

PROLED Flex Strip Opal Berlin (L6OP004) — L6OPxxx diagram (page 2)
Abb. 6 · L6OPxxx

Please use tools when removing Pulling on strip is not Min. 2 Persons needed at strip out of profile. Do not bend allowed and results a length of more than 2m. more than 15° in strip damages.

3. Preparing of strip
PROLED Flex Strip Opal Berlin (L6OP004) — L6OPxxx diagram (page 2)
Abb. 7 · L6OPxxx

Cut straight, along the cutting marks.

PROLED Flex Strip Opal Berlin (L6OP004) — L6OPxxx diagram (page 2)
Abb. 8 · L6OPxxx

Shorten the strip Expose the soldering pads with a knife Solder power cable to PCB

PROLED Flex Strip Opal Berlin (L6OP004) — L6OPxxx diagram (page 2)
Abb. 9 · L6OPxxx

Put the cable through end cap. Put the end cap on the strip. Put glue on the strip. Fill in 1/3 – 1/2 end cap with glue Laid flat for 2 hours. Place end cap on the strip Laid flat for 2 hours. The glue is dry after 24 hours

MBN GmbH, Balthasar-Schaller-Str. 3, 86316 Friedberg - Germany

www.proled.com

Page 3 of the PROLED Flex Strip Opal Berlin (L6OP004) user manual — L6OPxxx
Seite 3 · Zum Vergrößern klicken
Seite 3

Montageanleitung / Installation manual

Energy efficiency class of the light source:

Products listed in this manual contain a light source of following efficiency class, listed according to the item codes:

Item code Efficiency class of light source

L6OP0xx G L6OP0xx2G F L6OP1xx G L6OP1xx2G F L6OP2xx G L6OP2xx2G F L6OP30x F L6OP326 G L6OP336 G L6OP3xx2G F L6OP4xx G L6OP4xxDx G L6OP4xx2G F L6OP5xx G

ATTENTION: Installation and commissioning may only be performed by qualified persons. National installation regulations must be observed. Luminaires must be disconnected from mains before any work. The product is a “containing product” according to directive (EU) 2019/2020 and (EU) 2019/2015. The light source is an integral part of the containing product. Separating of light source and containing product results in irreversible damage. Exchange of the light source with commonly available tools is not useful for this product. The installed light source can be removed for testing purpose. The replacement of light source is not intended, as the containing product will be destroyed.

PROLED Flex Strip Opal Berlin (L6OP004) — L6OPxxx diagram (page 3)
Abb. 10 · L6OPxxx

03.22 Technical amendments reserved

MBN GmbH, Balthasar-Schaller-Str. 3, 86316 Friedberg - Germany

www.proled.com

Quellen

Referenzen & Links

In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.

Frage zu PROLED Flex Strip Opal Berlin (L6OP004) stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu PROLED Flex Strip Opal Berlin (L6OP004)

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

PROLED Flex Strip Opal Berlin (L6OP004) PDF-Anleitung

6 Seiten·118 KB·Leuchte·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…