DE
Gude logo
Offizielle Bedienungsanleitung

Gude Leaf Vacuum (GBLS 7500-26.1)

98 Seiten·1.6 MB·Garten & Rasen·PDF·ENJA
Gude Leaf Vacuum (GBLS 7500-26.1)
Inhaltsverzeichnis 24 Abschnitte --------------- DE Originalbetriebsanleitung · GBLS 7500-26.1 94399 · WSKAZÓWKI BEZPIECZEŃSTWA | KONSERWACJA | GWARANCJA| SERWIS __________________ 77 · INSTRUCCIONES SEGURIDAD | MANTENIMIENTO | GARANTÍA | SERVICIO __________________ 86 · … AnzeigenAusblenden
Page 1 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — GBLS 7500-26.1 94399
Seite 1 · Zum Vergrößern klicken
Seite 1

DE Originalbetriebsanleitung

EN Translation of the original instructions

FR Traduction du mode d’emploi d’origine

IT Traduzione del Manuale d’Uso originale

NL Vertaling van de originele gebruiksaanwijzing

CZ Překlad originálního návodu k provozu

SK Preklad originálneho návodu na prevádzku

HU Az eredeti használati utasítás fordítása

PL Tłumaczenie oryginalnej instrukcji obsługi

ES Traducción del manual de instrucciones original

Gude Leaf Vacuum (GBLS 7500-26.1) — --------------- DE Originalbetriebsanleitung diagram (page 1)
Abb. 1 · --------------- DE Originalbetriebsanleitung

GBLS 7500-26.1 94399

Page 2 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — --------------- DE Originalbetriebsanleitung
Seite 2 · Zum Vergrößern klicken
Seite 2

DEUTSCH Bitte lesen Sie die Gebrauchsanweisung vor Inbetriebnahme sorgfältig durch.

ENGLISH Please read the instructions carefully before starting the machine.

FRANÇAIS Veuillez lire avec soin le mode d‘emploi avant la mise en service

ITALIANO Leggere attentamente le istruzioni per l‘uso prima di mettere in funzione l‘elettroutensile.

NEDERLANDS Graag instructies zorgvuldig doorlezen vóórdat u de machine in gebruik neemt.

SLOVENSKY Pred prvým použitím prístroja si pozorne prečítajte návod na obsluhu.

CESKY Před spuštěnám stroje si pečlivě pročtěte návod k používání.

MAGYAR Kérjük alaposan olvassa el a tájékoztatót mielőtt a gépet használja.

POLSKI Przed przystąpieniem do uruchomienia prosimy o dokładne zapoznanie się z instrukcją obsługi.

ESPAÑOL Por favor, lea detenidamente estas instrucciones de uso antes de la puesta en marcha.

Page 3 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — INSTRUCCIONES SEGURIDAD | MANTENIMIENTO | GARANTÍA | SERVICIO __________________ 86
Seite 3 · Zum Vergrößern klicken
Seite 3

IINBETRIEBNAHME STARTING-UP THE MACHINE MISE EN SERVICE MESSA IN FUNZIONE INBEDRIJFSTELLING UVEDENÍ DO PROVOZU UVEDENIE DO PREVÁDZKY ÜZEMBE HELYEZÉS UVEDBA V POGON PUŠTANJE U RAD ПУСКАНЕ В ДЕЙСТВИЕ PUNEREA ÎN FUNCŢIUNE PUŠTANJE U RAD 7

Deutsch TECHNISCHE DATEN | BESTIMMUNGSGEMÄSSE VERWENDUNG | GERÄTEBESCHREIBUNG | RESTRISIKEN | VERHALTEN IM NOTFALL | ANFORDERUNGEN AN DEN BEDIENER | SYMBOLE | SICHERHEITSHINWEISE | WARTUNG | GEWÄHRLEISTUNG | SERVICE 16 English TECHNICAL DATA | SPECIFIED CONDITIONS OF USE | POWER TOOL DESCRIPTION | EMERGENCY PROCEDURE | RESIDUAL RISKS | EMERGENCY PROCEDURE | REQUIREMENTS FOR OPERATING STAFF | SYMBOLS | SAFETY INSTRUCTIONS | MAINTENANCE | GUARANTEE | SERVICE 24 Français CARACTÉRISTIQUES TECHNIQUES | SPECIFIED CONDITIONS OF USE | DESCRIPTION DE LA MACHINE | RISQUES RÉSIDUELS | CONDUITE EN CAS D’URGENCE | OPÉRATEUR | SYMBOLES | CONSIGNES DE SÉCURITÉ | ENTRETIEN | GARANTIE | SERVICE 31 Italiano DATI TECNICI | USO IN CONFORMITÀ ALLA DESTINAZIONE | DESCRIZIONE DELL’ELETTROUTENSILE | PERICOLI RESIDUALI | COMPORTAMENTO IN CASO D’EMERGENZA | REQUISITI ALL’OPERATORE | SIMBOLI | ISTRUZIONI | DI SICUREZZA | MANUTENZIONE | GARANZIA | ASSISTENZA 39 Nederlands TECHNISCHE GEGEVENS | VOORGESCHREVEN GEBRUIK VAN HET SYSTEEM | BESCHRIJVING VAN HET APPARAAT | RESTRISICO’S | HANDELSWIJZE IN NOODGEVAL | EISEN AAN DE BEDIENENDE PERSOON | SYMBOLEN | VEILIGHEIDSADVIEZEN | ONDERHOUD | GARANTIE | SERVICE 47 Cesky TECHNICKÉ ÚDAJE | POUŽITÍ V SOULADU S URČENÍM | POPIS PŘÍSTROJE | ZBYTKOVÁ NEBEZPEČÍ | CHOVÁNÍ V PŘÍPADĚ NOUZE | POŽADAVKY NA OBSLUHU | SYMBOLY | BEZPEČNOSTNÍ POKYNY | ÚDRŽBA | ZÁRUKA | SERVIS 55 Slovensky TECHNICKÉ ÚDAJE | POUŽITIE PODĽA PREDPISOV | POPIS PRÍSTROJA | SEKUNDARNE NEVARNOSTI | SPRÁVANIE V PRÍPADE NÚDZE | POŽIADAVKY NA OBSLUHU | SYMBOLY | BEZPEČNOTNÉ POKYNY | ÚDRZBA | ZÁRUKA | SERVIS 62 Magyar MŰSZAKI ADATOK | RENDELTETÉS SZERINTI HASZNÁLAT | A KÉSZÜLÉK LEÍRÁSA | MARADÉKVESZÉLYEK | VISELKEDÉS KÉNYSZERHELYZETBEN | KÖVETELMÉNYEK A GÉP KEZELŐJÉRE | SZIMBÓLUMOK | BIZTONSÁGI UTASÍTÁSOK | KARBANTARTÁS | JÓTÁLLÁS | SZERVIZ 69

Polski DANE TECHNICZNE | ZASTOSOWANIE ZGODNE Z PRZEZNACZENIEM | OPIS URZĄDZENIA | RYZYKO RESZTKOWE | POSTĘPOWANIE W NAGŁYM PRZYPADKU | WYMAGANIA STAWIANE UŻYTKOWNI- KOWI| SYMBOLE |

WSKAZÓWKI BEZPIECZEŃSTWA | KONSERWACJA | GWARANCJA| SERWIS 77

Español DATOS TÉCNICOS | USO PREVISTO | DESCRIPCIÓN DEL DISPOSITIVO | RIESGOS RESIDUALES | COMPORTAMIENTO EN CASO DE EMERGENCIA | REQUISITOS DEL OPERARIO | SÍMBOLOS |

INSTRUCCIONES SEGURIDAD | MANTENIMIENTO | GARANTÍA | SERVICIO 86

Originalkonformitätserklärung | Original Declaration of Conformity | L‘original de la déclaration de conformité | L‘originale della dichiarazione di conformità | Originele conformiteitverklaring | Originál prohlášení o shodě | Originál vyhlásenia o zhode | Megfelelőségi nyilatkozat eredeti példánya | Original izjave o skladnosti | Original izjave o istvojetnosti | Оригинал на декларацията за съответствие | Originalul Declarației de conformitate | Original izjave o istvojetnosti 96

Page 4 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — WSKAZÓWKI BEZPIECZEŃSTWA | KONSERWACJA | GWARANCJA| SERWIS __________________ 77
Seite 4 · Zum Vergrößern klicken
Seite 4

LIEFERUMFANG | DELIVERED ITEMS | ARTICLES DÉLIVRÉS | VOLUME DELLA FORNITURA | LEVERINGSOMVANG | OBJEM DODÁVKY | ROZSAH DODÁVKY | SZÁLLÍTÁSI TERJEDELEM | ZAKRES DOSTAWY | VOLUMEN DE SUMINISTRO

Gude Leaf Vacuum (GBLS 7500-26.1) — WSKAZÓWKI BEZPIECZEŃSTWA | KONSERWACJA | GWARANCJA| SERWIS __________________ 77 diagram (page 4)
Abb. 2
Page 5 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — WSKAZÓWKI BEZPIECZEŃSTWA | KONSERWACJA | GWARANCJA| SERWIS __________________ 77
Seite 5 · Zum Vergrößern klicken
Seite 5

DE Montage EN Assembly FR Montage IT Montaggio NL Montage CZ Montáž SK Montáž HU Szerelés

PL Montaż ES Montaje

DE Betrieb EN Operation FR Fonctionnement IT Esercizio NL Gebruik CZ Provoz SK Prevádzka HU Üzemeltetés

PL Eksploatacja ES Funcionamiento

DE Transport / Lagerung EN Transport / storage FR Transport / Stockage IT Trasporto / Stoccaggio NL Transport / Bewaring CZ Přeprava / Uložení SK Transport / Uloženie HU Szállítás / Tárolás

PL Transport / przechowywanie ES Transporte/almacenamiento

Page 6 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — WSKAZÓWKI BEZPIECZEŃSTWA | KONSERWACJA | GWARANCJA| SERWIS __________________ 77
Seite 6 · Zum Vergrößern klicken
Seite 6
Gude Leaf Vacuum (GBLS 7500-26.1) — WSKAZÓWKI BEZPIECZEŃSTWA | KONSERWACJA | GWARANCJA| SERWIS __________________ 77 diagram (page 6)
Abb. 3
Gude Leaf Vacuum (GBLS 7500-26.1) — WSKAZÓWKI BEZPIECZEŃSTWA | KONSERWACJA | GWARANCJA| SERWIS __________________ 77 diagram (page 6)
Abb. 4
Gude Leaf Vacuum (GBLS 7500-26.1) — WSKAZÓWKI BEZPIECZEŃSTWA | KONSERWACJA | GWARANCJA| SERWIS __________________ 77 diagram (page 6)
Abb. 5
Gude Leaf Vacuum (GBLS 7500-26.1) — WSKAZÓWKI BEZPIECZEŃSTWA | KONSERWACJA | GWARANCJA| SERWIS __________________ 77 diagram (page 6)
Abb. 6
Gude Leaf Vacuum (GBLS 7500-26.1) — WSKAZÓWKI BEZPIECZEŃSTWA | KONSERWACJA | GWARANCJA| SERWIS __________________ 77 diagram (page 6)
Abb. 7
Gude Leaf Vacuum (GBLS 7500-26.1) — WSKAZÓWKI BEZPIECZEŃSTWA | KONSERWACJA | GWARANCJA| SERWIS __________________ 77 diagram (page 6)
Abb. 8
Page 7 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — 4+5
Seite 7 · Zum Vergrößern klicken
Seite 7
Gude Leaf Vacuum (GBLS 7500-26.1) — 4+5 diagram (page 7)
Abb. 9
DE Montage EN Assembly FR Montage IT Montaggio NL Montage CZ Montáž SK MontážPL Montaż OPEREASTIOMNontaje RUČNÁ OBSLUH BETRIEB VYSAVAČ ZAPNUT SERVICE RUČNÍ OPERAZIONE RUČNI POGON1 HU Szerelés

DE - Beim Saugbetrieb muss immer der Fangsack und der Winkel montiert sein! EN - When suction of the collection bag and the angle must always be mounted! FR - Lorsque l‘aspiration de la poche de recueil et l‘angle doit toujours être monté! IT - Quando aspirazione della sacca di raccolta e l‘angolo deve essere sempre montate! NL - Wanneer zuigkracht van de opvangzak en de hoek altijd moet worden gemonteerd!

CZ - Pokud musí být vždy namontován sací pytle sběru a úhlu! SK - Ak musí byť vždy namontovaný sacie vrecia zberu a uhla! HU - Amikor a szívó a gyűjtőzsák és az a szög mindig PL - Worek i kątownik muszą być zawsze zamontowane podczas trybu ssania! ES - ¡La bolsa colectora y el ángulo deben estar siempre montados durante la aspiración!

A

Gude Leaf Vacuum (GBLS 7500-26.1) — A diagram (page 7)
Abb. 10

B

Gude Leaf Vacuum (GBLS 7500-26.1) — B diagram (page 7)
Abb. 11

B

B

Gude Leaf Vacuum (GBLS 7500-26.1) — B diagram (page 7)
Abb. 12

B

Gude Leaf Vacuum (GBLS 7500-26.1) — B diagram (page 7)
Abb. 13

4+5

Page 8 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — 4+5
Seite 8 · Zum Vergrößern klicken
Seite 8
OPER 1 BETR SERV OPERDE Montage/Funktion PL Montaż AETNIONAssembly RUČNÁ OBSLUHES Montaj IEFBR Montage VYSAVAČ ZAPNUT ICITE Montaggio RUČNÍ NL Montage AZIONE RUČNI POGON CZ Montáž SK Montáže HU Szerelés
Gude Leaf Vacuum (GBLS 7500-26.1) — 4+5 diagram (page 8)
Abb. 14
Gude Leaf Vacuum (GBLS 7500-26.1) — 4+5 diagram (page 8)
Abb. 15
Gude Leaf Vacuum (GBLS 7500-26.1) — 4+5 diagram (page 8)
Abb. 16
Gude Leaf Vacuum (GBLS 7500-26.1) — 4+5 diagram (page 8)
Abb. 17

IT - Il micro-switch deve essere azionato dal coperchio sia il tubo di aspirazione o nella modalità „bolle“ di funzionamento. NL - De micro-schakelaar moet worden bediend door het deksel ofwel de zuigleiding of in de modus „bubbels“. CZ - Mikro-spínač musí být ovládány krytu buď sací potrubí nebo v provozním režimu „bublin“. SK - Mikro-spínač musí byť ovládané krytu buď sacie potrubie alebo v prevádzkovom režime „bublín“. HU - A mikro-kapcsolót működtetni kell a fedelét vagy a szívócső vagy üzemmód „buborékok“. PL - Mikroprzełącznik musi być uruchomiony przez rurę ssącą lub pokrywę w trybie pracy „Dmuchanie”. ES - El microinterruptor debe accionarse desde el tubo de aspiración o, en el modo “soplado”, desde la cubierta.

DE - Der Mikroschalter muss entweder vom Saugrohr oder bei der Betriebsart „Blasen“ von der Abdeckung betätigt werden. EN - The micro-switch must be actuated by the cover either the suction pipe or in the operating mode „bubbles“. FR - Le micro-interrupteur doit être actionné par le couvercle soit le tuyau d‘aspiration ou dans le mode mode „bulles“.zione o nella modalità „bolle“ di funzionamento.

Page 9 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — 4+5
Seite 9 · Zum Vergrößern klicken
Seite 9
DE Tanken EN Fuel tank filling FR Ravitaillement IT Rabbocco NL Tanken CZ Tankování SK TankovaniePL Tankowanie OPEREASTIOLlNenado RUČNÁ OBSLUH BETRIEB VYSAVAČ ZAPNUT SERVICE RUČNÍ OPERAZIONE RUČNI POGON2 HU Tankolás
Gude Leaf Vacuum (GBLS 7500-26.1) — 4+5 diagram (page 9)
Abb. 18
Gude Leaf Vacuum (GBLS 7500-26.1) — 4+5 diagram (page 9)
Abb. 19
Page 10 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — START
Seite 10 · Zum Vergrößern klicken
Seite 10

DE Betrieb EN Operation FR Fonctionnement IT Esercizio NL Gebruik CZ Provoz SK Prevádzka HU Üzemeltetés

PL Eksploatacja ES Funcionamiento

Gude Leaf Vacuum (GBLS 7500-26.1) — 3 ON ON diagram (page 10)
Abb. 20
Gude Leaf Vacuum (GBLS 7500-26.1) — 3 ON ON diagram (page 10)
Abb. 21

3 ON ON

Gude Leaf Vacuum (GBLS 7500-26.1) — 3 ON ON diagram (page 10)
Abb. 22

START

DE Betrieb

Page 11 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — RUN
Seite 11 · Zum Vergrößern klicken
Seite 11
Gude Leaf Vacuum (GBLS 7500-26.1) — RUN diagram (page 11)
Abb. 23

DE Betrieb EN Operation FR Fonctionnement IT Esercizio NL Gebruik CZ Provoz SK Prevádzka HU Üzemeltetés

Gude Leaf Vacuum (GBLS 7500-26.1) — RUN diagram (page 11)
Abb. 24

DE Anwerfseil ca. 3-4x kräftig ziehen bis erste hörbare Zündung erfolgt. EN Pull firmly the starting rope approx. 3-4 times till the first noise of running is evident. FR DTirez fermement 3-4x sur le câble de démarrage, jusqu’au premier allumage audible. IT Tirare fortemente cca 3-4 volte la funicella d’avviamento, finché non avviene la prima accensione udibile. NL Aan het startkoord ca. 3-4x krachtig trekken, tot de eerste hoorbare ontsteking plaatsvindt. CZ Za nahazovací lanko zatáhněte silně cca 3-4x, dokud nedojde k prvnímu slyšitelnému zapálení. SK Za štartovacie lanko zatiahnite silno cca 3 – 4×, pokým nedôjde k prvému počuteľnému zapáleniu

HU A startoló zsinórt 3-4X erősen rántsa meg, addig, mig hallhatóan be nem kapcsolódik. PL Pociągnąć mocno ok. 3-4 razy za linkę rozruchową aż do pierwszego słyszalnego zapłonu. ES Tirar de la cuerda del motor aprox. 3-4 veces hasta que se produzca el primer encendido audible.

Gude Leaf Vacuum (GBLS 7500-26.1) — RUN diagram (page 11)
Abb. 25
Gude Leaf Vacuum (GBLS 7500-26.1) — RUN diagram (page 11)
Abb. 26
Gude Leaf Vacuum (GBLS 7500-26.1) — RUN diagram (page 11)
Abb. 27

RUN

Page 12 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — RUN
Seite 12 · Zum Vergrößern klicken
Seite 12
Gude Leaf Vacuum (GBLS 7500-26.1) — RUN diagram (page 12)
Abb. 28

DE Betrieb EN Operation FR Fonctionnement IT Esercizio NL Gebruik CZ Provoz SK Prevádzka HU Üzemeltetés

Gude Leaf Vacuum (GBLS 7500-26.1) — RUN diagram (page 12)
Abb. 29
Gude Leaf Vacuum (GBLS 7500-26.1) — RUN diagram (page 12)
Abb. 30
Page 13 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — RUN
Seite 13 · Zum Vergrößern klicken
Seite 13
Gude Leaf Vacuum (GBLS 7500-26.1) — RUN diagram (page 13)
Abb. 31

DE Reinigung / Wartung EN Cleaning / Maintenance FR Nettoyage / Entretien IT Pulizia / Manutenzione NL Schoonmaken / Onderhoud CZ Čištění / Údržba SK Čistenie / Údrzba HU Tisztítás / Karbantartás

Gude Leaf Vacuum (GBLS 7500-26.1) — RUN diagram (page 13)
Abb. 32
Page 14 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — RUN
Seite 14 · Zum Vergrößern klicken
Seite 14
Gude Leaf Vacuum (GBLS 7500-26.1) — RUN diagram (page 14)
Abb. 33

DE Reinigung / Wartung EN Cleaning / Maintenance FR Nettoyage / Entretien IT Pulizia / Manutenzione NL Schoonmaken / Onderhoud CZ Čištění / Údržba SK Čistenie / Údrzba HU Tisztítás / Karbantartás

Gude Leaf Vacuum (GBLS 7500-26.1) — RUN diagram (page 14)
Abb. 34
Page 15 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — RUN
Seite 15 · Zum Vergrößern klicken
Seite 15
Gude Leaf Vacuum (GBLS 7500-26.1) — RUN diagram (page 15)
Abb. 35

DE Reinigung / Wartung EN Cleaning / Maintenance FR Nettoyage / Entretien IT Pulizia / Manutenzione NL Schoonmaken / Onderhoud CZ Čištění / Údržba SK Čistenie / Údrzba HU Tisztítás / Karbantartás

Gude Leaf Vacuum (GBLS 7500-26.1) — RUN diagram (page 15)
Abb. 36
Page 16 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — Specified Conditions Of Use
Seite 16 · Zum Vergrößern klicken
Seite 16

Technical Data Petrol Leaf Blower GBLS 7500-26.1

8 | Spark plug 9 | Choke 10 | Air filter 11 | Fuel tank 12 | Primer pump 13 | Bowden starter 14 | ON/OFF switch 15 | throttle-lever 16 | Screw Protective grille mounting 17 | Microswitch

Art. No 94399

Engine 2-Takt OHV

Motor output 0,75 kW/0,95 PS

bei max. 8000 min-1

Contents 25,4 ccm

Idle speed 2800 min-1

Air velocity ca. 252 km/h

Safety instructions

Leaf bag capacity ca. 40 l

tank capacity/Fuel 0,45 l/40:1

Weight netto 5,4 kg

To operate the leaf vacuum in a safe way, all instructions and information on safety, installation and operation in the Operating Instructions must strictly be followed. All persons operating or servicing the appliance must be familiar with the Operating Instructions and know the potential dangers. It is necessary to prevent access to children, ill and infirm persons. Children must be carefully supervised if near machines. Comply with the applicable regional and local accident prevention regulations. The same applies to all occupational safety and health provisions.

Noise and Vibration Information Sound pressure level Lpa: 98,6 dB(A) Sound power level Lwa: 109,6 dB(A) Uncertainty K: 2,26 dB(A) Guaranteed sound power level Lwa: 112 dB(A) Measured according to 2000/14 EG Vibration emission value ah: 5,428 m/s² Uncertainty K: 1,5 m/s² Measured according to EN 60335

The manufacturer cannot be held liable in case of an unauthorised change on the appliance resulting to damage.

Read and understand the opera- ting instructions before using the appliance. Abide by all the safety measures stated in the service manual. Act responsib- ly toward third parties. In case of any doubts about connection and operati- on refer please to our customer center

1. Pay attention to conditions of the environment you are working in. Once the engine starts running, toxic gases are produced. These gases may be odourless and invisible. Therefore, never work with the appliance in closed or poorly ventilated areas. Ensure adequate lighting when working. Provide a safe posture, especially in wet, snowy, icy conditions, on slopes, on an uneven terrain.

Specified Conditions Of Use

The leaf blower has been designed to blow or vacu- um dry leaves.

Do not use this product in any other way as stated for normal use.Respecting technical data and safety pre- cautions.Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages. Power tool description

2. Do not let any unauthorised persons stay near the machine. Prevent unauthorised persons from contact with the tools.

Keep bystanders and animals in a safe distance from the garden appliance. Thrown-off stones may lead to injuries.

1 | Engine unit 2 | Exhaust tube 3 | Suction tube 4 | Connection angle Leaf collection bag 5 | Leaf collection bag 6 | Mixing bottle 7 | Spark plug wrench

Never blow any dirt/leaves in the direction of persons or animals.

3. Ensure safe storage of the tools. Tools not being used must be stored in a dry place, elevated or otherwise inaccessible if possible.
Page 17 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — Technical Data Petrol Leaf Blower GBLS 7500-26.1
Seite 17 · Zum Vergrößern klicken
Seite 17
4. Use the appropriate tools and appliances for your work at all times. Do not use e.g. any small tools or accessories for works that actually need to be performed with heavy tools/accessories. Use the tools and appliances for purposes for which they have been designed.

vibrations during your work.

11. Time of use and breaks. A longer use of a motor unit can lead to poor circulation of blood in hands due

to vibrations. However, you can extend the time of use with suitable gloves or regular breaks. Please keep in mind that personal susceptibility to poor circulation of blood, low outside temperatures or great clasp forces during work reduce the time of use.

5. Ensure adequate clothing. Clothing must be purposeful and must not prevent from working. Do not wear any scarves, chains or other loosely hanging accessories. Long hair should be tied up.
12. Pay attention to parts if not damaged. Check the appliance before using it. Are any parts damaged? As for slight damage, ask yourself whether the appliance is going to work perfectly and safely. Ensure correct alignment and adjustment of the moving parts. Do party fit correctly into each other? Are any parts damaged? Is everything installed properly? Are all preconditions for perfect working met?
6. Use hearing protection, respiratory protection, sight protection and sturdy shoes. Use personal protective equipment against noise, e.g. hearing protection, dust mask, safety glasses and shoes with a non-slip sole.
7. Transport of leaves from the vacuum. Secure the appliance against turnover, damage and fuel leakage.

Damaged protective equipment must professionally repaired or changed by authorised person, unless otherwise provided in the operating instructions. Defective switches must be changed by authorised personnel. Please contact your local servicing centre for any repair.

8. Remove the socket wrench, etc. All wrenches, etc. must be removed before switching the leaf blower on.
9. Stay concentrated all the time. Pay attention to what you are doing. Use common sense. Do not use any power tools when you are tired. You must not work with the leaf vacuum when you are under the influence of alcohol, drugs or pharmaceuticals that could reduce your ability to respond.
13. Switch off the engine before any adjustment or servicing work. Do so especially when adjusting the suction and blowing function.
14. Use only approved parts. Use only identical spare parts for servicing or repairs. Contact your authorised servicing centre for spare parts.

Petrol is highly flammable

  • Store the fuel only in containers specifically approved for that purpose, in a safe place, away from heat and open fire.
  • Do not smoke when handling fuel.

The appliance may only be used for the intended purpose. Any misuse is regarded an improper use. The user, not the manufacturer in any case, is responsible for any material damage and injury of persons arising from such improper use.

  • Refuel outdoors only - use either the fuel bottle included or a funnel.
  • Add fuel before starting the engine. The fuel tank cap must not be opened or engine fuel filled when the engine is running or is still hot.

The manufacturer cannot be held liable in any case should changes be made on its appliances or should its appliances be used incorrectly, resulting in damage.

  • Do not start the appliance in the place of refuelling as there could be petrol residues or vapours that could cause fire.

Operate the appliance with the attached nozzle only.

10. Engine fuel filling Always turn off the engine before refuelling. Open the fuel tank cap very carefully so that excessive pressure could slowly be eliminated and no fuel squirts out. High temperatures on the housing body are produced when working with the leaf vacuum. Therefore, let the vacuum cool down before refuelling. Otherwise, fuel could get ignited and cause severe burns. When refuelling, make sure you do not refuel too much. If the liquid has leaked outside the tank, it must be immediately removed and the appli- ance cleaned. After refuelling, make sure the screw cap is fitted correctly so that it is not released as a result of

  • Switch the engine off before any adjustment or servicing.
  • Make the Operating Instructions available to all persons who are to work with the appliance.
  • Use the machine only for vacuuming leaves. This machine is not suitable for larger pieces of wood or even larger stones. This can lead to appliance damage and may also be a source of danger for persons and users.
Page 18 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — Emergency procedure
Seite 18 · Zum Vergrößern klicken
Seite 18

ment must be refitted properly after servicing or a repair is finished.

  • It is essential to know the accident prevention regulations applicable in the place of use of the appliance and all other, generally recognised safety regulations.
  • Ensure adequate lighting at all times.
  • Do not use the leaf vacuum near flammable liquids or gases.
  • Ensure solid footing and keep balance during your work.
  • Do not blow and vacuum hot, flammable or explosive materials.
  • Check the appliance for any sign of wear.
  • Do not let children and frail persons get near the appliance when in use.
  • The safety equipment must necessarily be checked before using the appliance. Make sure the parts slightly affected at first sight are working properly.
  • Check the appliance for damage. Do not use an appliance that is defective or damaged.
  • Have the appliance repaired only in an authorised service centre.
  • Check whether all movable parts are working perfectly. Pay particular attention to any damage and fixing parts. All parts must be installed properly and meet all conditions for perfect working.
  • Do not try to execute any repair yourselves. Repairs and replacement of parts may only be performed by an authorised service centre.
  • Unless otherwise provided in these Operating Instructions, damaged parts and safety equipment must be repaired or replaced by an authorised service centre.
  • Be careful of the tripping hazard near the leaf vacuum.
  • The person working with the appliance should not be distracted.
  • Have any defective switches replaced in an authorised service centre.
  • The protective equipment of the appliance must not be demounted or otherwise put out of operation in any case.
  • The appliance complies with all relevant safety regulations. Repairs may only be executed by qualified electricians in an authorised service centre, using original spare parts. Failure to do so may result in injury.
  • Damaged or defective protective equipment must be immediately replaced.
  • When working with the leaf vacuum, do not let yourself be disturbed, act wisely before paying attention to a new situation.

AVOID EXPOSURE TO NOISE

  • Applicable local regulations regarding the noise level of leaf vacuuming appliances must be complied with and followed.
  • At regular intervals, check whether all screws, nuts and other fasteners are tight firmly.
  • Never place tools or materials above the appliance so that they cannot fall on the appliance.
  • Do not operate the appliance in the day time when other people would be disturbed by unexpected noise (e.g. early in the morning or late at night). Times given in local regulations must be complied with.
  • Do not overload the appliance, otherwise it will run more slowly and overheat.
  • Do not try to take out the leaf bag when the appliance is running. This can only be performed when the appliance is off.
  • To keep the sound pressure level as low as possible, the number of simultaneously working appliances must be limited.
  • The appliance must first be turned off and the spark plug removed before removing any defect.
  • Do not add more gas than it is necessary for the respective work.
  • Adjusting, measurement, cleaning, etc. may only be performed when the machine is off and the spark plug removed.
  • Before use, check the appliance, especially the exhaust muffler, air suction and the air filter.
  • Do not leave the place of your work unattended if the engine is not turned off.

Emergency procedure

Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further

  • If servicing or a repair of the safety and protective equipment is to be performed, such equip-
Page 19 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — Symbols
Seite 19 · Zum Vergrößern klicken
Seite 19

harm and calm them down. For the sake of eventual accident, in accordance with DIN 13164, a workplace has to be fitted with a first-aid kit. It is essential to replace any used material in the first-aid kit immedia- tely after it has been used. If you seek help, state the following pieces of information:: 1. Accident site 2. Accident type 3. Number of injured persons 4. Injury type(s)

Keep children and other persons inclu- ding animals in a safe distance when using the appliance.

Requirements for operating staff

Prohibited smoking and open fire using.

The operating staff must carefully read the Opera- ting Instructions before using the appliance.

Inhaling exhaust gases may be fatal! Toxic exhaust fumes and oil vapors can cause poisoning.

Qualification: : Apart from the detailed instructions by a professional, no special qualification is necessary for appliance using. Minimum age: : Persons over 16 years of age can only work on the appliance. An exception includes youngsters trained in order to reach knowledge under supervision of the trainer during occupational education. Training: : Using the appliance only requires corre- sponding training by a professional or the Operating Instructions. No special training is necessary.

distance from other persons! Make sure there is no person in the area of danger.

Symbols

Read the Operating Instructions

When working with the appliance, always keep Wear eye protective goggles ! Wear ear protectors!

Wear protective gloves !

To be used outdoors only.

Never expose tool to rain.

Prohibited smoking and open fire using. Never use the appliance in a flammable environment.

Show 9 more labels / short text on this page
Protect against humidity · Protect against frost · Strongly · Choke function · throttle-lever · Protect against humidity · Fuel mix ratio · Protect against humidity · This side up
Page 20 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — Operation
Seite 20 · Zum Vergrößern klicken
Seite 20

28 Putting into operation for your safety

2. Blowing function use

With this, you can blow leaves, grass or dirt on a large area to a pile and then dispose them.

Comply with the following, in particular::

  • Functionality of switches
  • Proper installation of the suction or blow tube
  • Smooth running of all switches.
  • Safe fixing of the spark plug connector. A loose connector can cause sparking and ignition of the leaking fuel and air mixture.

Guarantee

Warranty period of 12 months applies to commercial use and 24 months applies to private use and com- mences on the day of purchase of the device. The guarantee solely covers inadequacies caused by material defect or manufacturing defect. Original payment voucher with the sales date needs to be sub- mitted for any claim in the guarantee period. The guarantee does not cover any unauthorised use such as appliance overloading, use of violence, damage as a result of any unauthorised interference or caused by foreign items. Failing to follow the ope- rating and assembly instructions and common wear are also not included in the guarantee.

  • Ensure the handle is clean so that you can guide the leaf vacuum safely.

Before starting the appliance, all safety and protective equipment must be properly installed and in its place.

Assembly

1. The suction or blow tube and the leave collection bag are always installed according to an identical scheme. The tube is inserted in the respective clamping and secured by turning. Further securing using a screw is done for clamping of the blow tube or leaf collection bag.

Service

Do you have any technical questions? Any claim? Do you need any spare parts or operating instructions? We will quickly help you and without needles bure- aucracy at our web pages at www.guede.com in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. All this data can be found on the type label. Please enter it here for future reference:

2. When installing the suction tube, make sure it is seated properly as the safety switch is controlled by the tube. Otherwise, the appliance will not start.
3. Fix the leaf collection bag using the Velcro around the connection angle tube.

Serial No.:

Operation

Art. No:

When working, always keep the leaf vacuum app. 3 cm above the ground.

Year of production:

The appliance noise level depends on the revolutions! Always use only revolutions that are necessary for the given work.

Tel.: +49 (0) 79 04 / 700-360 Fax: +49 (0) 79 04 / 700-51999 E-Mail: support@ts.guede.com

You have two options of using the appliance:

1. Suction function use

With this, you can suck leaves, grass or dirt to the leaf collection bag.

Page 21 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — Instructions
Seite 21 · Zum Vergrößern klicken
Seite 21

29 product in or after the warranty period must be made in the original packaging.

The package protects the appliance against damage during transport. Packing materials are usually cho- sen depending on their environmental friendliness and disposal method and can therefore be recycled. Returning the package to material circulation saves raw materials and reduces waste disposal costs. Parts of packages (e.g. foils, styropor®) can be dangerous to children. Risk of suffocation! Keep parts of packages away from children and dispose them as soon as possible.

Maintenance/Storage

Keep the leaf blower clean so that it can work properly and safely. This applies to the ventilation slots, in parti- cular. Never spray water on the leaf blower and do not plunge it into water.

Risk of suffocation! Keep parts of the packagings out of reach of children and dispose them as soon as possible.

Keep the garden appliance in a safe and dry place, inaccessible to children.

If the machine has any defect, the repair may only be executed by the customer service. Original accessories and original spare parts to be used only.

Only a regularly maintained and treated appliance can be a satisfactory aid. Insufficient maintenance and treatment may lead to unforeseen accidents and injuries

These instructions apply to normal conditions of use. In difficult conditions, such as severe dust and long daily working house, the intervals must be shortened accordingly.

Check the following before starting to work:

  • throttle-lever
  • Throttle lever
  • ON/OFF switch
  • Safety equipment
  • Strength of all movable parts

Repairs requiring special professional knowledge should be executed by authorised service centres. An unauthorised intervention may damage the appliance or put your safety at risk.

Instructions

The disposal instructions are based on the icons placed on the appliance or on the package. Descrip- tion of the respective meanings can be found in the section „Marking“.

Transport package disposal

Page 22 of the Gude Leaf Vacuum (GBLS 7500-26.1) user manual — Inspection and maintenance plan
Seite 22 · Zum Vergrößern klicken
Seite 22

Failures – causes - removal

The motor does not start

Empty fuel tank Over floated motor

Top-up fully the fuel tank Release the throttle, start a couple of times and remove the spark plug if necessary, clean it and dry it Clean the spark plug, check the plug ther- mal value, possibly change the plug, set the electrodes distance to 0.6-0.7 mm Clean, blow, the carburettor replace Check the short-circuiting button, cable, check or, as appropriate, replace the ignition module, adjust to 0.6-0.7 mm

Spark plug is dirty (carbon residues on elec- trodes), too big gap between electrodes. Dirty carburettor, nozzle Faulty connection of the spark plug, defec- tive cable of the spark plug Missing spark

Idle speed too high Cold engine Slowly heat the engine or, as appropriate, close the choke a little bit

Engine not running at maximum power

Spark plug is dirty (carbon residues on elec- trodes), too big gap between electrodes. Dirty carburettor, nozzle Dirty air filter Exhaust, inlet duct of the cylinder

Clean the spark plug, check the plug ther- mal value, possibly change the plug, set the electrodes distance to 0.6-0.7 mm Clean, blow, the carburettor Clean or replace the air filter Remove and clean the exhaust and remove the carbon residues. replace Replace the cylinder, piston or piston rings, grind off the cylinder overlap and install a bigger fraction of the piston Fill the fuel tank according to the manual Contact gap size of ignition module (0,6-0,7 mm) let adjusted in authorized workshop

Leaking gasket in the crankcase Wrong fuel mixture (too much oil) Bad ignition

Motor can not be switched off

Light grey candle with signs of glowing Carbon residues in the combustion chamber

Install a spark plug with a higher thermal value Clean the cylinder head, piston bottom and cylinder channels

Inspection and maintenance plan

Gude Leaf Vacuum (GBLS 7500-26.1) — Inspection and maintenance plan diagram (page 22)
Abb. 37 · Inspection and maintenance plan

Failures Causes Removal

Quellen

Referenzen & Links

In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.

Frage zu Gude Leaf Vacuum (GBLS 7500-26.1) stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Gude Leaf Vacuum (GBLS 7500-26.1)

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Gude Leaf Vacuum (GBLS 7500-26.1) PDF-Anleitung

98 Seiten·1.6 MB·Garten & Rasen·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…