Art. No. F004516 - F004517 - F004518 - F004519



M - 5 4
M - 5 3
M - 5 2
M - 5 1
DC 24V


NL HANDLEIDING
DE BEDIENUNGSANLEITUNG
DC input

GB INSTRUCTION MANUAL
Art. No. F004516 - F004517 - F004518 - F004519
PARTS OVERVIEW AND SCOPE OF DELIVERY

RISK OF MATERIAL DAMAGE! Make sure that no one can trip over or get caught in connection cables of the background system! Components could break off and fall to the ground.
The manufacturer accepts no liability for damage to property caused by improper or insufficiently safe installation!
Only use the recommended power supply for the power adapter!
The manufacturer accepts no liability for voltage damage caused by the use of an unsuitable power adapter!
Never bend, squeeze or pull power cables, connecting cables, extensions or connectors. Protect cables from sharp edges and heat. Check this device, cables and connections for damage before use. Never attempt to operate a damaged device, or a device with damaged electrical parts! Damaged parts must be replaced immediately by an authorized service agent.
Operate the device only in a completely dry environment and do not touch the device with wet or damp body parts.
FIRE/EXPLOSION HAZARD! Mount the individual components so that they cannot be pulled down or can fall to the ground.
Do not expose the device to high temperatures. Do not short-circuit the device or dispose of in fire! Excessive heat and improper handling can cause short circuits, fires and even explosions!
A Motor panel (1x) B Control box ( 1x) C Remote control (1x) D Hook unit1 (2x ) E Power supply unit(1x) F Power cable (1x) G Roll holder2 H Motor2 / Instruction manual
Additionally required Aluminium rod4 (diam.: 165mm long Paper roll + 10 cm), weighting rod for paper roll (e.g. art. no. F004394)
Disconnect the power supply by pulling the mains plug when the appliance is not in use, in case of a longer interruption of operation and before any maintenance and cleaning work.
Mount your device so that it can be disconnected from the power supply at any time. The power outlet should always be near your appliance and should be easily accessible, as the plug of the power cord serves as a disconnect device from the mains supply. To disconnect the unit from the mains, always pull the mains plug and never pull the cable!
Motor connection socket2 Function light Power connection socket Connecting cable Wall mount Display [M] button sbutton tbutton Function light [M] button tbutton sbutton Battery compartment C12 connection socket Function light Hollow plug (power cable) C12 plug Power plug Hook Roll holder spreader Knurled screw Hollow plug (motor cable)
Do not subject the device to excessive vibrations.
1depending on model with 2, 3, 4 or 6 hooks / 2depending on model 2, 3, 4 or 6 pieces included / 3not included / 4available in hardware stores; use recommended for safety reasons


and right into the paper tubes or aluminium tubes3,4 of the background rolls. 2. Fix the roll holders in the tube/aluminium pipe with the knurled screws (22). IMPORTANT: For background rolls wound on cardboard tubes, the cardboard tube should be replacedby an aluminium tube3,4 to prevent sagging or kinking!
M-5
M-4
M-3
M
M-2
DC
(A) near the motors using suitable screws and, if necessary, dowels. 2. Insert the hollow plugs of the motor cable (23) into the desired motor connection sockets (1) of the motor panel (A).
M-5
M-4
M-3
M-2
M-1
DC
MOTORS & PANEL 1. Insert the hollow plug of the power supply cable (16) into the power connection socket (3) of the motor panel (A). 2. Insert the C12 plug (18) into the C12 connection socket (15) on. 3. Insert the Euro plug into the mains power socket. The function light (16) lights up. The power supply is established.
REMOTE CONTROL 1. Open the battery compartment (14). 2. Insert the batteries according to the indicated pole orientation (+/-). 3. Close the battery compartment (14) again.
1depending on model with 2, 3, 4 or 6 hooks / 2depending on model 2, 3, 4 or 6 pieces included / 3not included / 4available in hardware stores; use recommended for safety reasons

TECHNICAL DATA
PER CONTROL BOX 1. Press the [M] button (7) to set the desired motor (M1-M6). The display (6) shows the number of the selected motor (1-6). 2. Press the s(8) or t(9) button to wind or unwind the background roll attached to the selected motor.
Voltage input: AC110-240V, 50~60Hz Voltage output: DC24V/2.7A Controller: Manually via control box or via remote control Power: 50W per motor Load capacity per level: maximum 20 kg
SET UP REMOTE CONTROL IMPORTANT: Before using the remote control for the first time, it must be set up. Proceed as follows: 1. Establish the power supply for the remote control and the motor panel with the motors connected. 2. Press and hold the [M] button on the remote control for 3-5 seconds until a red dot flashes on the display (6) of the control box. 3. Press and hold the [M] button again for 3-5 seconds until the green function light (10) on the remote control flashes. The setup is complete.
REMOTE CONTROL Number of controllable motors: up to 6 motors Power supply: 2 pcs. of 1.5V batteries, type AAA/LR03 Transmission frequency 2.4GHz ISM band
USE REMOTE CONTROL Once set up is finished, the remote control can be used as follows: 1. Press the [M] button (11) to set the desired motor (M1-M6). The display (6) of the control box shows the number of the selected motor (1-6). 2. Press the t(12) or s(13) button to wind or unwind the background roll attached to the selected motor.
1depending on model with 2, 3, 4 or 6 hooks / 2depending on model 2, 3, 4 or 6 pieces included / 3not included / 4available in hardware stores; use recommended for safety reasons
In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.