DE
Bresser logo
Offizielle Bedienungsanleitung

Bresser Electric Background System (BR-EBS-2)

12 Seiten·824 KB·Fotografie·PDF·ENFRITJA
Bresser Electric Background System (BR-EBS-2)
Inhaltsverzeichnis 32 Abschnitte BR-EBS-2/3/4/6 · Electric background system Elektrisch achtergrondsysteem Elektr. Hintergrund-System · M - 5 6 · M - 5 · … AnzeigenAusblenden
Page 1 of the Bresser Electric Background System (BR-EBS-2) user manual — GB INSTRUCTION MANUAL
Seite 1 · Zum Vergrößern klicken
Seite 1

BR-EBS-2/3/4/6

Electric background system Elektrisch achtergrondsysteem Elektr. Hintergrund-System

Art. No. F004516 - F004517 - F004518 - F004519

Bresser Electric Background System (BR-EBS-2) — Electric background system Elektrisch achtergrondsysteem Elektr. Hintergrund-System diagram (page 1)
Abb. 1 · Electric background system Elektrisch achtergrondsys…
Bresser Electric Background System (BR-EBS-2) — Electric background system Elektrisch achtergrondsysteem Elektr. Hintergrund-System diagram (page 1)
Abb. 2 · Electric background system Elektrisch achtergrondsys…

M - 5 6

Bresser Electric Background System (BR-EBS-2) — M - 5 6 diagram (page 1)
Abb. 3

M - 5

M - 5 4

M - 5 3

M - 5 2

M - 5 1

DC 24V

Bresser Electric Background System (BR-EBS-2) — M - 5 diagram (page 1)
Abb. 4
Bresser Electric Background System (BR-EBS-2) — M - 5 diagram (page 1)
Abb. 5

GB INSTRUCTION MANUAL

NL HANDLEIDING

DE BEDIENUNGSANLEITUNG

DC input

Page 2 of the Bresser Electric Background System (BR-EBS-2) user manual — PARTS OVERVIEW (Fig. 1
Seite 2 · Zum Vergrößern klicken
Seite 2

BR-EBS-2/3/4/6

Electric background system with remote control

GB INSTRUCTION MANUAL

Art. No. F004516 - F004517 - F004518 - F004519

GENERAL WARNINGS

PARTS OVERVIEW AND SCOPE OF DELIVERY

Bresser Electric Background System (BR-EBS-2) — GENERAL WARNINGS diagram (page 2)
Abb. 6

RISK OF MATERIAL DAMAGE! Make sure that no one can trip over or get caught in connection cables of the background system! Components could break off and fall to the ground.

The manufacturer accepts no liability for damage to property caused by improper or insufficiently safe installation!

Only use the recommended power supply for the power adapter!

The manufacturer accepts no liability for voltage damage caused by the use of an unsuitable power adapter!

Never bend, squeeze or pull power cables, connecting cables, extensions or connectors. Protect cables from sharp edges and heat. Check this device, cables and connections for damage before use. Never attempt to operate a damaged device, or a device with damaged electrical parts! Damaged parts must be replaced immediately by an authorized service agent.

Operate the device only in a completely dry environment and do not touch the device with wet or damp body parts.

FIRE/EXPLOSION HAZARD! Mount the individual components so that they cannot be pulled down or can fall to the ground.

Do not expose the device to high temperatures. Do not short-circuit the device or dispose of in fire! Excessive heat and improper handling can cause short circuits, fires and even explosions!

  • Only use the recommended power supply*!

SCOPE OF DELIVERY (Fig. 1)

A Motor panel (1x) B Control box ( 1x) C Remote control (1x) D Hook unit1 (2x ) E Power supply unit(1x) F Power cable (1x) G Roll holder2 H Motor2 / Instruction manual

Additionally required Aluminium rod4 (diam.: 165mm long Paper roll + 10 cm), weighting rod for paper roll (e.g. art. no. F004394)

Disconnect the power supply by pulling the mains plug when the appliance is not in use, in case of a longer interruption of operation and before any maintenance and cleaning work.

Mount your device so that it can be disconnected from the power supply at any time. The power outlet should always be near your appliance and should be easily accessible, as the plug of the power cord serves as a disconnect device from the mains supply. To disconnect the unit from the mains, always pull the mains plug and never pull the cable!

PARTS OVERVIEW (Fig. 1

Motor connection socket2 Function light Power connection socket Connecting cable Wall mount Display [M] button sbutton tbutton Function light [M] button tbutton sbutton Battery compartment C12 connection socket Function light Hollow plug (power cable) C12 plug Power plug Hook Roll holder spreader Knurled screw Hollow plug (motor cable)

Do not subject the device to excessive vibrations.

1depending on model with 2, 3, 4 or 6 hooks / 2depending on model 2, 3, 4 or 6 pieces included / 3not included / 4available in hardware stores; use recommended for safety reasons

Page 3 of the Bresser Electric Background System (BR-EBS-2) user manual — M-6
Seite 3 · Zum Vergrößern klicken
Seite 3

GENERAL ASSEMBLY INSTRUCTIONS

  • Before assembly, remove all accessories from the package and lay them out on a level surface.
  • Only use screws and, if necessary, dowels that provide a sufficiently high load-bearing capacity (minimum 25 kg per roll incl. all attachments) .
  • Only connect the individual electronic components with the connection/power cables supplied. ATTENTION: Do not install defective cables and/or electronic parts and do not put them into operation!

MOUNTING (Fig. 2-5)

Bresser Electric Background System (BR-EBS-2) — MOUNTING (Fig. 2-5) diagram (page 3)
Abb. 7 · MOUNTING (Fig. 2-5)
1. 1. Push one roll holder 2 (G) with and one without motor (H) left
2. 1. Measure the length of the background roll incl. mounted roll holder and motor connection. 2. Mount the hook units1 (D) to the left and right of the wall or ceiling using suitable screws and, if necessary, dowels. IMPORTANT: Precise vertical and horizontal alignment must be ensured!

and right into the paper tubes or aluminium tubes3,4 of the background rolls. 2. Fix the roll holders in the tube/aluminium pipe with the knurled screws (22). IMPORTANT: For background rolls wound on cardboard tubes, the cardboard tube should be replacedby an aluminium tube3,4 to prevent sagging or kinking!

POWER SUPPLY 6) Fig. 4

M-6

M-5

M-4

M-3

M

M-2

3. Hook the background rolls, which are preassembled with roll holders and motor, into the hooks (20) on the left and right at the desired levels. IMPORTANT: It is strongly recommended to lift the background rolls only with two persons and to hook them into the hooks due to the high weight!

M-1

DC

4. 1. Mount the motor panel

A

(A) near the motors using suitable screws and, if necessary, dowels. 2. Insert the hollow plugs of the motor cable (23) into the desired motor connection sockets (1) of the motor panel (A).

M-6

M-5

M-4

M-3

M-2

M-1

DC

MOTORS & PANEL 1. Insert the hollow plug of the power supply cable (16) into the power connection socket (3) of the motor panel (A). 2. Insert the C12 plug (18) into the C12 connection socket (15) on. 3. Insert the Euro plug into the mains power socket. The function light (16) lights up. The power supply is established.

REMOTE CONTROL 1. Open the battery compartment (14). 2. Insert the batteries according to the indicated pole orientation (+/-). 3. Close the battery compartment (14) again.

1depending on model with 2, 3, 4 or 6 hooks / 2depending on model 2, 3, 4 or 6 pieces included / 3not included / 4available in hardware stores; use recommended for safety reasons

Page 4 of the Bresser Electric Background System (BR-EBS-2) user manual — WARRANTY
Seite 4 · Zum Vergrößern klicken
Seite 4

ENGINE CONTROL

TECHNICAL DATA

PER CONTROL BOX 1. Press the [M] button (7) to set the desired motor (M1-M6). The display (6) shows the number of the selected motor (1-6). 2. Press the s(8) or t(9) button to wind or unwind the background roll attached to the selected motor.

MOTOR PANEL/CONTROL BOX Number of connectable motors: up to 6 motors 2

Voltage input: AC110-240V, 50~60Hz Voltage output: DC24V/2.7A Controller: Manually via control box or via remote control Power: 50W per motor Load capacity per level: maximum 20 kg

BY REMOTE CONTROL

SET UP REMOTE CONTROL IMPORTANT: Before using the remote control for the first time, it must be set up. Proceed as follows: 1. Establish the power supply for the remote control and the motor panel with the motors connected. 2. Press and hold the [M] button on the remote control for 3-5 seconds until a red dot flashes on the display (6) of the control box. 3. Press and hold the [M] button again for 3-5 seconds until the green function light (10) on the remote control flashes. The setup is complete.

REMOTE CONTROL Number of controllable motors: up to 6 motors Power supply: 2 pcs. of 1.5V batteries, type AAA/LR03 Transmission frequency 2.4GHz ISM band

USE REMOTE CONTROL Once set up is finished, the remote control can be used as follows: 1. Press the [M] button (11) to set the desired motor (M1-M6). The display (6) of the control box shows the number of the selected motor (1-6). 2. Press the t(12) or s(13) button to wind or unwind the background roll attached to the selected motor.

WARRANTY

www.bresser.de/warranty_terms

1depending on model with 2, 3, 4 or 6 hooks / 2depending on model 2, 3, 4 or 6 pieces included / 3not included / 4available in hardware stores; use recommended for safety reasons

Quellen

Referenzen & Links

In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.

Frage zu Bresser Electric Background System (BR-EBS-2) stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Bresser Electric Background System (BR-EBS-2)

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Bresser Electric Background System (BR-EBS-2) PDF-Anleitung

12 Seiten·824 KB·Fotografie·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…