DE
Dometic logo
Offizielle Bedienungsanleitung

Dometic LPG Combi Heater (CH4000)

148 Seiten·5.4 MB·Heizgerät·PDF·EN
Dometic LPG Combi Heater (CH4000)
Inhaltsverzeichnis 32 Abschnitte Explanation of symbols · Safety instructions · Handling the device · Handling electrical cables · … AnzeigenAusblenden
Page 1 of the Dometic LPG Combi Heater (CH4000) user manual — HU
Seite 1 · Zum Vergrößern klicken
Seite 1

HEATING LPG COMBI HEATERS

Dometic LPG Combi Heater (CH4000) — HEATING LPG COMBI HEATERS diagram (page 1)
Abb. 1

CH4000, CH4000E, CH6000, CH6000E

LPG Combi Heater Installation and Service Manual 9

LPG kombinirani grijač Upute za montažu i servisni priručnik 92

HR

LPG-Kombi-Heizgerät Montage- und Servicehandbuch 14

LPG Kombi Isıtıcı Kurulum ve Servis Kılavuzu 97

DE

TR

Chauffage combiné GPL Instructions de montage et de service 20

Kombinirani grelnik na utekočinjen naftni plin Navodila za montažo in servisiranje 102

FR

SL

Calentador combinado de GLP Manual de servicio y montaje 26

Încălzitor combinat GPL Manual de instalare şi service 107

ES

RO

Aquecedor combinado de GPL Montagem e manual de instruções 32

Комбиниран газов нагревател Ръководство за инсталация и сервиз 113

PT

BG

Riscaldatore combinato a GPL Manuale di installazione e manutenzione 38

LPG kombikütteseade Paigaldus- ja hooldusjuhend 119

IT

ET

Lpg-combiverwarming Montage- en servicehandleiding 44

Συνδυαστικός θερμαντήρας LPG Εγχειρίδιο τοποθέτησης και σέρβις 124

NL

EL

LPG-kombinationsvarmer Monterings- og servicevejledning 50

LPG kombinuotasis šildytuvas Montavimo ir priežiūros instrukcija 130

DA

LT

LPG Combi-värmare Monterings- och skötselanvisning 55

SV

Sašķidrinātas naftas gāzes (LPG) kombinētais sildītājs Uzstādīšanas un servisa rokasgrāmata 135

LPG-kombivarmer Monterings- og serviceanvisning 60

NO

Hitarasamstæða með fljótandi jarðolíugasi Uppsetningar- og þjónustuhandbók 140

IS

Nestekaasutoiminen yhdistelmälämmitin Asennus- ja huolto-ohje 65

FI

Łączony ogrzewacz gazowy Instrukcja montażu i serwisowa 70

PL

Kombinovaný LPG ohrievač Návod na montáž a servisná príručka 76

SK

Kombinovaný ohřívač na LPG Návod k montáži a servisu 81

CS

Folyékony PB gáz kombinált fűtőberendezés Telepítési és szerviz útmutató 86

HU

Page 2 of the Dometic LPG Combi Heater (CH4000) user manual
Seite 2 · Zum Vergrößern klicken
Seite 2

© 2021 Dometic Group. The visual appearance of the contents of this manual is protected by copyright and design law. The underlying technical design and the products contained herein may be protected by design, patent or be patent pending. The trademarks mentioned in this manual belong to Dometic Sweden AB. All rights are reserved.

Page 3 of the Dometic LPG Combi Heater (CH4000) user manual — 4445103144 3
Seite 3 · Zum Vergrößern klicken
Seite 3
Dometic LPG Combi Heater (CH4000) diagram (page 3)
Abb. 2

4445103144 3

Page 4 of the Dometic LPG Combi Heater (CH4000) user manual — 4 4445103144
Seite 4 · Zum Vergrößern klicken
Seite 4
Dometic LPG Combi Heater (CH4000) diagram (page 4)
Abb. 3

2 x 3 m 1 x 1.5 m : min

2 x 6 m 2 x 3 m : max

4 4445103144

Page 5 of the Dometic LPG Combi Heater (CH4000) user manual — 4445103144 5
Seite 5 · Zum Vergrößern klicken
Seite 5
Dometic LPG Combi Heater (CH4000) diagram (page 5)
Abb. 4

4445103144 5

Page 6 of the Dometic LPG Combi Heater (CH4000) user manual — 6 4445103144
Seite 6 · Zum Vergrößern klicken
Seite 6
Dometic LPG Combi Heater (CH4000) diagram (page 6)
Abb. 5

6 4445103144

Page 7 of the Dometic LPG Combi Heater (CH4000) user manual — 4445103144 7
Seite 7 · Zum Vergrößern klicken
Seite 7
Dometic LPG Combi Heater (CH4000) diagram (page 7)
Abb. 6

4445103144 7

Page 8 of the Dometic LPG Combi Heater (CH4000) user manual — 8 4445103144
Seite 8 · Zum Vergrößern klicken
Seite 8
Dometic LPG Combi Heater (CH4000) diagram (page 8)
Abb. 7

8 4445103144

Page 9 of the Dometic LPG Combi Heater (CH4000) user manual — Intended use
Seite 9 · Zum Vergrößern klicken
Seite 9

Original Instructions

Handling electrical cables !

Please read these instructions carefully and follow all instructions, guidelines, and warnings included in this product manual in order to ensure that you install, use, and maintain the product properly at all times. These instructions MUST stay with this product. By using the product, you hereby confirm that you have read all instructions, guidelines, and warnings carefully and that you understand and agree to abide by the terms and conditions as set forth herein. You agree to use this product only for the intended purpose and application and in accordance with the instructions, guidelines, and warnings as set forth in this product manual as well as in accordance with all applicable laws and regula- tions. A failure to read and follow the instructions and warnings set forth herein may result in an injury to yourself and others, damage to your product or damage to other property in the vicinity. This product manual, including the instructions, guidelines, and warnings, and related documentation, may be subject to changes and updates. For up-to-date product information, please visit documents.dometic.com.

  • NOTICE!
  • Use cable ducts to lay cables through walls with sharp edges.
  • Do not lay loose or bent cables next to electrically conductive materials (metal).
  • Do not pull on the cables.

Explanation of symbols ! ! A

Target group for this instruction manual

The instructions in this manual are intended for qualified personnel at workshops who are familiar with the guidelines and safety precautions to be applied.

Scope of delivery

See fig. 1, page 3.

Safety instructions

Please observe the prescribed safety instructions and stipula- tions from the vehicle manufacturer and service workshops.

Accessories

No. in fig. 2,

  • Electric shock

1 Control panel (Rotary Controller 1.5", DICM) (mandatory)

  • Fire hazards

2 Side cowl (mandatory)

  • Injury

3 Window switch (optional)

4 Hose clamp 80 mm (for exhaust duct)

Handling the device !

5 Hose clamp 65 mm (for warm air ducts)

  • WARNING!
  • Installation and repair of the device must only be carried out by qualified personnel who are familiar with the risks involved and the relevant regulations. Inadequate repairs may cause serious hazards. For repair service, please contact the manufacturer‘s support (see back page).
  • In the event of a fire only use approved extinguishing agents. Do not use water to extinguish fires. !

Intended use

The heater is designed for use in motor caravans, caravans and other vehicles with habitation compartments only, when the gas system is installed in accordance with EN 1949.

  • CAUTION!
  • The device must be installed securely so that it cannot fall down.
  • Only operate the device if you are certain that the housing and the cables are not damaged.
  • Defective devices must not be used.
  • Do not use the device near flammable fluids.
  • Make sure no combustible objects are stored or installed near the air outlets. A distance of at least 50 cm must be kept.
  • Do not use the device without warm air ducts mounted. A

The device is not suitable for installation in construction machines, agricul- tural machines, utility vehicles, marine craft, houses and apartments, hunt- ing and forestry cabins, weekend homes, awning tents or similar equipment.

The device may only be used to heat drinking water and to heat the inte- rior of the vehicle. Never use it to warm other liquids.

Only use the device with original warm air ducts and side cowl from the manufacturer installed. Never use other warm air ducts or cowls.

The device may only be operated while driving if facilities are installed to prevent uncontrolled leakage of liquid gas in the event of an accident (according to UN-ECE regulation 122).

  • NOTICE!
  • Only use the device as intended.
  • Do not make any alterations or conversions to the device.

Devices not installed according to the manufacturer‘s installation require- ments are not allowed to be used.

If the device is installed in vehicles for commercial use, the national legal and insurance requirements need to be considered by the operator.

This product is only suitable for the intended purpose and application in accordance with these instructions.

page 3 Description

Page 10 of the Dometic LPG Combi Heater (CH4000) user manual — Notes on installation
Seite 10 · Zum Vergrößern klicken
Seite 10

This manual provides information that is necessary for proper installation and/or operation of the product. Poor installation and/or improper oper- ating or maintenance will result in unsatisfactory performance and a possi- ble failure.

  • The installation of the device in vehicles must comply with the technical and administrative regulations of the respective country of use (e.g. EN 1949). The national legislation and regulations (e.g. DVGW Work Sheet G 607 for vehicles in Germany) must be observed.

The manufacturer accepts no liability for any injury or damage to the prod- uct resulting from:

  • Incorrect assembly or connection, including excess voltage

See fig. 3, page 3.

  • Incorrect maintenance or use of spare parts other than original spare parts provided by the manufacturer

Notes on installation location !

  • Alterations to the product without express permission from the manufacturer
  • WARNING! Risk of suffocation The cowl must be positioned in such a way that exhaust gases cannot enter the interior.
  • Never run the exhaust duct outwards on the underside of the vehicle. Always run the exhaust duct to the side using a side cowl.
  • Observe the notes given in fig. 4 , page 3 to fig. 6 , page 3.
  • Use for purposes other than those described in this manual

Dometic reserves the right to change product appearance and product specifications.

The manufacturer accepts no liability for any injury or damage to the prod- uct due to frost caused by the user not following the instructions in the manual.

  • Observe the notes given in fig. 4 , page 3 to fig. c , page 4.

Data plate

  • Choose a place that is easily accessible for servicing as well as installing and disassembling.

A data plate is attached to the device. This data plate provides the user and fitter with information on specifications of the device.

  • Do not place the device on or above heat-sensitive materials.
  • Before installing the device, check whether any vehicle components could be damaged by the installation of the device (such as lamps, cupboards, doors).

Installation !

  • For safety reasons, note the location of existing wiring harnesses, wires and other components within the installation area, in particular those which are not visible, when installing the device (when drilling or screwing etc.).
  • If the cowl is installed under a window that can be opened, an electric window switch must be installed.

Notes on installation

  • Make sure that the air drawn in by the device cannot be contaminated by vehicle exhaust gases or by exhaust gases from the device.

Read this installation manual completely before installing the device.

  • The safety and drain valve must be installed directly besides to the device. It must be placed below the cold water connection. It must be easily accessible for operation.

The following tips and instructions must be observed while installing the device: ! ! !

  • Only install the heater in a water cycle which contains a pressure pump with pressure regulator.
  • The hoses, pipes and ducts must be routed in such a way that the device is easy to remove for service work.
  • CAUTION! Risk of injury
  • Improper installation of the device can result in irreparable damage to the device and put the safety of the user at risk.
  • Always wear suitable protective clothing (e.g. protective goggles, gloves).
  • To ensure the correct function, pipes and ducts must be laid tensionfree and as short as possible.
  • Do not crush or kink pipes and ducts.
  • Warm air ducts and exhaust ducts might warm up the environment. Make sure that there is no material in contact with the warm air ducts which suffers from heat. Keep a distance of least 10 mm.
  • The water hoses for connecting to the boiler and the safety and drain valve must be safe for drinking water, pressure resistant up to 4.5 bar and hot water-resistant up to +80 °C.
  • If the heater is operated while driving, a safety shut-off device must be installed to prevent an uncontrolled escape of LPG in the event of an accident (according to UN ECE regulation 122). If no safety shut-off device is installed, you can connect the D+ signal to the heater to prevent any operation while driving.
  • Check the compatibility of the data plate information with the gas supply requirements of the vehicle.
  • Only a qualified electrician should connect the device to the electrical power.
  • Check that the voltage specification on the data plate is the same as that of the power supply.

Regulations

Page 11 of the Dometic LPG Combi Heater (CH4000) user manual — Initial start-up
Seite 11 · Zum Vergrößern klicken
Seite 11
  • Do not lay cables which are loose or bent next to electrically conductive material (metal).
5. Set the following settings (see operation manual): – max. fan speed in silent mode – min. fan speed in ventilation mode.
  • Protect cables from sharp edges.
6. Mark the year of installation on the data plate.
  • CH4000E, CH6000E only : Install an all-pole switch with a contact opening width of at least 3 mm on the installation side for the AC supply (230 V).
7. Supply the owner of the vehicle with the operating manual.
8. Check all functions of the device, especially the emptying of the water heater.
  • If the device is powered by the mains ( CH4000E, CH6000E only ): ensure that the AC voltage supply has a residual current circuit breaker.

When a brand-new device is initially put into operation, smoke and odours may develop for a short time.

➤In this case, ensure that the interior is well ventilated and operate the

Notes on connection with a solar system A

appliance for a few minutes at the highest temperature level for self- cleaning: – set room temperature to max. value – choose auto mode for air heating – choose hot mode for water heating.

Replacing fuses !

Mounting and connecting the device

1. Mount the device according to fig. d , page 4.
2. Mount the control panel according to fig. e , page 4 to fig. g , page 5.
3. Install the exhaust duct and cowl according to fig. i , page 5 to fig. l , page 6. – Guide the exhaust duct directly after the unit in a curve to the side or upwards according to fig. h , page 5. This helps to prevent rattling and reduce noise. – Fix exhaust duct at least every 50 cm (fig. h , page 5) using clamps (accessory).

➤Replace broken DC fuses according to fig. w, page 8. Only use fuses

with the same value.

Cleaning and maintaining

➤Clean the device according to fig. x, page 8.

4. Install the warm air ducts according to fig. m , page 6 and fig. n , page 6.

➤Never use detergents containing chlorine for cleaning and disinfec-

5. Observe water connection scheme: fig. o , page 6.

tion.

6. Mount the safety and drain valve and connect to cold water supply according to fig. p , page 6 to fig. q , page 7.

➤Perform self-cleaning once a week: see chapter “Self-cleaning” on

page 11.

7. Connect the hot water outlet according to fig. r , page 7.

➤If side cowl is positioned below a window: Check window switch

8. Connect the venting hose according to fig. s , page 7.

operation as a pre trip or seasonal check.

9. Ensure that the operating pressure of the gas supply and the device are the same, see data plate.

➤Check regularly, especially after long journeys, that the cowl and the

exhaust duct are intact and correctly fixed.

10. Connect to the gas supply according to fig. t , page 7.

➤Operate the safety and drain valve regularly, at least twice a year, to

11. Connect the device to power supply according to fig. u , page 7. – You can use D+ connection if no safety shut-off device (according to UN ECE regulation 122) is installed. – Make sure that at least 12 V is available at the device.

remove limescale deposits and ensure proper function.

➤Have the heater, its gas supply and ducting for the products of com-

bustion checked by an expert in accordance with national regulations (e.g. in Germany every 2 years). If no national regulations exist that should be done at least every 2 years. The inspection must be certified on a test certificate (e.g. DVGW Work Sheet G 607 for vehicles in Ger- many).

Legend to fig. u, page 7

No. Description

1 Window switch (optional accessory)

2 Room temperature sensor

To clean the system against bacteria operate the heater for a few minutes at the highest temperature level for self-cleaning:

Initial start-up

1. Set room temperature to max. value.
1. Attach the supplied sticker with warnings in a clearly visible place on the heater or inside the vehicle, e. g. on the wardrobe door.
2. Choose auto mode for air heating.
3. Choose hot mode for water heating.
2. If data plate is no more accessible after installation, attach the accompanied data plate (copy) to a place close to the device that is accessible.
3. After installation, have the tightness of the gas supply line checked by a specialist, using the pressure drop method, and a test certificate issued (in Germany, e.g. in accordance with DVGW worksheet G 607).
4. Set value for under voltage alarm according to fig. v , page 7.

Self-cleaning

Page 12 of the Dometic LPG Combi Heater (CH4000) user manual — Disposal
Seite 12 · Zum Vergrößern klicken
Seite 12

Troubleshooting

Error CodeCauseRemedy 416Master gas valve error➤ Execute the default routine. 417Gas valve relay error➤ Execute the default routine. 418Air heater start error➤ Execute the default routine. 419Water heater start error➤ Execute the default routine. 420Air heater flame out➤ Execute the default routine. 421Water heater flame out➤ Execute the default routine. 422Air heater overheat1. Assure that air heater is switched off. 2. Wait 15 – 30 minutes until heater has cooled down. 3. Check if all air inlet grilles and the cabin air ducting to the heater are not blocked. 4. Restart air heater. 5. If heater does not operate properly contact the manufacturer‘s support. 423Water heater overheat1. Assure that water heater is switched off. 2. Wait 15 – 30 minutes until heater has cooled down. 3. Check if boiler is filled with water. 4. Refill with water if water was missing. 5. Restart water heater. 6. If heater does not operate properly contact the manufacturer‘s support. 424Window opened (only if window switch is installed)1. Check if the window above the cowl is opened. 2. If window was opened close window and restart heater. 3. If window was closed execute the default routine. 434Self shutdown. Service warning has been ignored too long.➤ Contact the manufacturer‘s support for service. Heater can only be restarted after service.

Firmware version

➤Read out the firmware versions of the display (HMI) and of the heater

according to fig. y, page 8.

Default routine for trouble shooting

Only execute the default routine if it is proposed in the error code table.

1. Wait 3 minutes, then restart.
2. If the heater does not operate properly contact the manufacturer‘s support.

Contacting the manufacturer‘s support

See back page of this manual.

Error code table

Error CodeCauseRemedy 002Battery voltage low1. Check battery voltage and compare them to under voltage setting. 2. Charge battery. 3. Connect vehicle to AC power. 4. If none above solves the issue contact the manufacturer‘s support. 003Battery voltage high1. Check battery voltage and ensure it is less than 16.5 V. If battery voltage is higher than 16.5 V either a wrong battery is connected or battery is broken. 2. Replace battery with battery that supplies DC power according to technical data (see data plate). 3. In case vehicle is connected to AC power check if battery is charging. 4. If battery is charging check charging voltage (must be lower than 16.5 V to assure proper function whilst charging). 005Fuse blown1. Check DC power fuses (chapter “Replacing fuses” on page 11). 2. If heater does not operate properly contact the manufacturer‘s support. 007General system error➤ Contact the manufacturer‘s support. 008Communication error➤ Execute the default routine. 403Air pressure sensor error➤ Execute the default routine. 404Circulation air temperature sensor error➤ Execute the default routine. 406Water temperature sensor error➤ Execute the default routine. 408Room temperature sensor error➤ Execute the default routine. 409Air heater flame sensor error➤ Execute the default routine. 410Water heater flame sensor error➤ Execute the default routine. 411Combustion fan error➤ Execute the default routine. 412Circulation blower error➤ Execute the default routine. 413Air heater gas valve 1 error➤ Execute the default routine. 414Air heater gas valve 2 error➤ Execute the default routine. 415Water heater gas valve error➤ Execute the default routine.

Warning code table

CodeCauseRemedy 425Water frozen.1. Reset warning. Water heating is shut down. Only air heating is operating. 2. Operate the air heating at the highest level so that the interior temperature rises and the water heating is ready for operation again. 432CH4000E, CH6000E only: No more AC power supply available.1. Reset warning. Heater is now only operated with gas. 2. Check power supply. 433Service required.1. Reset warning. 2. Contact the manufacturer‘s support for service after your vacation or at the next opportunity. If you wait too long, the heater will turn itself off and can only be restarted after service.

Disposal

➤Place the packaging material in the appropriate recycling waste bins

wherever possible.

Page 13 of the Dometic LPG Combi Heater (CH4000) user manual — MAX
Seite 13 · Zum Vergrößern klicken
Seite 13

Technical data

CH4000 CH4000E CH6000 CH6000E

ManufacturerDometic Germany GmbH, Hollefeldstr. 63, 48282 Emsdetten, Germany
Product Identification Number0063DL3129
Countries of first destinationAT/BE/BG/CH/CY/CZ/DE/DK/EE/ES/FI/FR/GB/GR/HR/HU/IE/

IS/IT/LI/LT/LU/LV/MC/MT/NL/NO/PL/PT/RO/SE/SI/SK/SM/TR

Heating capacity4000 W 4000 W (1800 W electrical)

6000 W 6000 W (1800 W electrical)

Rated input voltage: 10–16.5 Vg 10–16.5 Vg 220–240 Vw, 50/60 Hz 10–16.5 Vg 10–16.5 Vg 220 – 240 Vw, 50/60 Hz

Current consumption (12 Vg): Water heating 0.7 A

Water heating 0.7 A Max. air heating 12 A

Max. air heating 7 A

Stand-by consumption5 mA
Required fuse15 A
Appliance categoryI 3B/P (30)
Gas categoryLPG / Butane
Gas connection pressure30 mbar

Gas consumption:

325 g/h 487 g/h

MAX

Gas stand-by consumption7.7 g/h (maintain water temperature)

Nominal heat input:

4.55 kW (Hs) 6.8 kW (Hs)

MAX

2.5 kW (Hs)

6.85 kW (Hs)

Water connection pressuremax. 2.8 bar

Boiler (water volume at 2.8 bar): 10 l

Heating-up timeapprox. 17 min (10 l, heated-up from 15 °C to 60 °C)
Operating temperature range–20 °C to +60 °C

Dimensions L x W x H: 514 x 438 x 298 mm

Weight17.3 kg 18.5 kg 17.3 kg 18.5 kg

Inspection/certification:

183 g/h · 505 g/h

Quellen

Referenzen & Links

In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.

Display-Codes

Fehlercodes

Was die auf dem Display angezeigten Fehlercodes bedeuten und wie man sie behebt.

CodeBedeutungLösung
416Master gas valve error➤ Execute the default routine. p.12
417Gas valve relay error➤ Execute the default routine. p.12
418Air heater start error➤ Execute the default routine. p.12
419Water heater start error➤ Execute the default routine. p.12
420Air heater flame out➤ Execute the default routine. p.12
421Water heater flame out➤ Execute the default routine. p.12
422Air heater overheat1. Assure that air heater is switched off. 2. Wait 15 – 30 minutes until heater has cooled down. 3. Check if all air inlet grilles and the cabin air ducting to the heater are not blocked. 4. Restart air heater. 5. If heater does not operate properly contact the manufacturer‘s support. p.12
423Water heater overheat1. Assure that water heater is switched off. 2. Wait 15 – 30 minutes until heater has cooled down. 3. Check if boiler is filled with water. 4. Refill with water if water was missing. 5. Restart water heater. 6. If heater does not operate properly contact the manufacturer‘s support. p.12
424Window opened (only if window switch is installed)1. Check if the window above the cowl is opened. 2. If window was opened close window and restart heater. 3. If window was closed execute the default routine. p.12
434Self shutdown. Service warning has been ignored too long.➤ Contact the manufacturer‘s support for service. Heater can only be restarted after service. p.12
002Battery voltage low1. Check battery voltage and compare them to under voltage setting. 2. Charge battery. 3. Connect vehicle to AC power. 4. If none above solves the issue contact the manufacturer‘s support. p.12
003Battery voltage high1. Check battery voltage and ensure it is less than 16.5 V. If battery voltage is higher than 16.5 V either a wrong battery is connected or battery is broken. 2. Replace battery with battery that sup- plies DC power according to techni- cal data (see data plate). 3. In case vehicle is connected to AC power check if battery is charging. 4. If battery is charging check charging voltage (must be lower than 16.5 V to assure proper function whilst charg- ing). p.12
005Fuse blown1. Check DC power fuses (chapter “Replacing fuses” on page 11). 2. If heater does not operate properly contact the manufacturer‘s support. p.12
007General system error➤ Contact the manufacturer‘s support. p.12
008Communication error➤ Execute the default routine. p.12
403Air pressure sensor error➤ Execute the default routine. p.12
404Circulation air tempera- ture sensor error➤ Execute the default routine. p.12
406Water temperature sensor error➤ Execute the default routine. p.12
408Room temperature sensor error➤ Execute the default routine. p.12
409Air heater flame sensor error➤ Execute the default routine. p.12
410Water heater flame sensor error➤ Execute the default routine. p.12
411Combustion fan error➤ Execute the default routine. p.12
412Circulation blower error➤ Execute the default routine. p.12
413Air heater gas valve 1 error➤ Execute the default routine. p.12
414Air heater gas valve 2 error➤ Execute the default routine. p.12
415Water heater gas valve error➤ Execute the default routine. p.12
425Water frozen.1. Reset warning. Water heating is shut down. Only air heat- ing is operating. 2. Operate the air heating at the highest level so that the interior temperature rises and the water heating is ready for operation again. p.12
432CH4000E, CH6000E only: No more AC power supply available.1. Reset warning. Heater is now only operated with gas. 2. Check power supply. p.12
433Service required.1. Reset warning. 2. Contact the manufacturer‘s support for service after your vacation or at the next opportunity. If you wait too long, the heater will turn itself off and can only be restarted after service. p.12

Frage zu Dometic LPG Combi Heater (CH4000) stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Dometic LPG Combi Heater (CH4000)

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Dometic LPG Combi Heater (CH4000) PDF-Anleitung

148 Seiten·5.4 MB·Heizgerät·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…