Thank you for purchasing our product! Read this manual carefully prior to using the appliance.
Why does the appliance store less water in the water tank in winter? The temeprature is low and air is dry, not a fault.
Why can’t the appliance run or stops running suddenly? The water tank might be full of water or it is not installed properly – drain the water tank or re-install it. The appliance might be in the „dehumidification mode“, the ambient temperature is lower or higher than requested (it cannot be performed when the ambient temperatur eis < 5 °C or > 32 °C).
Why is hot air blown out from the air supply outlet? The appliance extracts air in the room and the dehumidification unit cools the air. The temperature decreases below the condensation point, the air condenses into water drops, which fall into the water tank and the dehumidified air is heated by the temperature running unit. This can reduce energy consumption and also accelerate dehumidification, therefore, hot air is blown out, not a fault.
Safety instructions · Frequent questions





Control panel with WIFI and water pump
Timer 24h timer setup, press this key to set on/off time of the dehumidifier. The setting range is 1-24h. If you want to cancel the setting, press twice after confirming the time setting.
Dry key in dehumidifier Press this key to start drying procedure in the appliance. This mode can prevent mold inside the appliance due to dampness. The whole drying procedure nees approximately 1h to finish. Press this button again to cancel the drying mode and to recover to running state beforehand.
Air speed In AUTO or CONTINUOUS mode air speed, high and low can be circularly selected.

LED display This figure displays room humidity. When humidity is set in AUTO mode, this figure shows the set humidity and displays the set time in timer state, % represents percentage of humidity.
Humidity setting Once this button is pressed, the humidity is displayed circularly in the range 30-80 % and the humidity setting is only valid in AUTO mode.
Long press this button for 3 seconds to turn on/off the pump function.
Mode During startup or timer setting, press this button to select desired mode. After choosing, the light indicator of the selected mode is on. Long press the Mode button to activate the Child Lock – repeat to unlock.
On/Off button Press this button to turn the appliance on/off.

Setting the timer off When the dehumidifier is running, press the TIMER button to adjust time from 1 to 24 hours. Press the button once to increase the setting by 1 hour – after the set time exceeds 24 hours, the figure returns back to 1 hour. The TIMER button can also be pressed at any time needed, the time increases or decreases circularly. When the time expires, the appliance turns OFF automatically. After the setting is completed, if the TIMER button does not act at all within 5 seconds, the set time is confirmed. In timer off state the key lamp on the TIMER button is ON.
Setting of timer on When the dehumidifer is in standby mode, the method for adjustment of setting time by the TIMER button is the same as timer off. After the setting is completed, if the TIMER button does not act at all within 5 seconds, the set time is confirmed. In timer off state the key lamp on the TIMER button is ON and the set time is displayed on control panel.
AUTO mode Select AUTO dehumidification. If the room humidity is higher than the set humidity by + 5 %, the compressor will start and the fan will run at the set speed. If the room humidity is between + 5% or - 5% of the set humidity, the compressor and the fan will run at the set speed. If the room humidity is lower than the set humidity by - 5%, then the compressor will stop but the fan will run at the set speed. The default set humidity value is 50%.
CONTINUOUS mode Select CONTINUOUS dehumidification, no matter how the relative humidity in the room is, the compressor starts, the fan runs at high speed in default setting and the air speed can be regulated via the air speed button.
DRYING function Press the DRYING button to start the drying process. The appliance starts at HIGH air speed and releases air continuously for 30 minutes. The appliance turns to run at LOW air speed and lasts for 20 minutes.
To stop, press the DRYING button again to cancel the process and recover to the prior running mode. Or, press the POWER button to stop the process and recover to standby mode.
Humidity indicate function Press the humidity setting button and the mode button at the same time to turn ON/turn OFF the humidity light indicator. When the machine works, the color of light belt on the front cover will change with humidit level. Red color show humidity over 60 %, green color shows humidity 40-60 % and blue color shows less than 40 % humidity.
Pump function Press the humidity setting for 3 seconds to turn on/off the pump function (connect the drainage pipe before turning the on the pump function).
Air-swing function Press the Timer button and the Drying button at the same time to start or end the Air-swing function.
Water drainage When the water tank is full, the full water icon on LCD display flashes (the compressor, fan and negative ion will stop running), the buzzer sounds 10 times to remind the user till the water is drained.
Operating methods


Continuous drainage If you don’t want to drain water from the water tank frequently, you can connect a drainage pipe:
When the pump funtion is off
When the pump function is on


When the pump function is off Find the position of water outlet, také down water cover, pull down the water plug.
Connect the pipe with 13 mm diameter/garden pipe.






Connect the pipe with 5 mm diameter.
Connect the pipe before turning the pump function on to prevent water leakage.

Precautions:



Maintenance

Display code – Instruction FL – The water tank is full
E1 – The coil sensor detects anomaly
E2 – The room temperature sensor detects anomaly
P1 – The unit is in the defrosting mode, normal
CL – The unit is in the internal drying state, normal
LC – Child lock on
The English version of the manual is an exact translation of the original manufacturer‘s instructions.
Images used in this manual are for illustrational purposes only and may differ from the actual product.
Troubleshooting

Download the G21 Smart Home app from Google Play or App Store.

Choose the type of the appliance you want to add
Connect to the WiFi you want to add your appliance to
The appliance Dehumidifier Impact is ready to use. You can change the name of your appliance now
You’re connected to the Mojewifina WiFi. If you want to add the appliance to this WiFi, click continue.
Otherwise, go to WiFi setting in your smartphone and connect to desired WiFi.
Click „Add appliance“.
Choose the appliance.
Follow the instructions on the screen.
Name your appliance and click „Finish“

Install drainage hose prior to turning this function on.
When switched on, the appliance start the self- drying process.

To avoid damage, place the unit in an upright position for at least 24 hours before initiation.
Make sure that the air outlet and air inlet are never blocked.
Only operate the unit on a horizontal surface to ensure no water leaks out.
» that the installation of pipe-work shall be kept to a minimum;
» that pipe-work shall be protected from physical damage and, in the case of flammable
refrigerants, shall not be installed in an unventilated space;
» that compliance with national gas regulations shall be observed;
» that mechanical connections shall be accessible for maintenance purposes;
» that, for appliances containing flammable refrigerants, the minimum floor area of the room shall
be mentioned in the form of a table or a single figure without reference to a formula;
READ THE MAUAL CAREFULLY BEFORE USING THE APPLIANCE
R290 refrigerant gas complies with European environmental directives.
Appliance shall be installed, operated and stored in a room with a floor area larger than 4 m2.

Additional warning for appliance with R290 refrigerant gas (refer to the rating plate for the type of refrigerant gas used)
Checks to the area Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following precaution shall be completed prior to conducting work on the system.
Work procedure Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed.
General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided.
Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially toxic or flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with all applicable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
Presence of fire extinguisher If any hot work is to be conducted on the refrigerating equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.
No ignition sources No person carrying out work in relation to a refrigerating system which involves exposing any pipe work shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks.
Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out.
Checks to the refrigerating equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt, consult the manufacturer’s technical department for assistance.
The following checks shall be applied to installations using flammable refrigerants:

Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with
Initial safety checks shall include:
Repairs to sealed components During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc.
Ensure that seals or sealing materials have not degraded to the point that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications.
Repair to intrinsically safe components Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use.
Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.
Cabling Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.
Detection of flammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.
Removal and evacuation When breaking into the refrigerant circuit to make repairs – or for any other purpose – conventional procedures shall be used. However, for flammable refrigerants it is important that best practice is followed since flammability is a consideration.

The following procedure shall be adhered to:
The refrigerant charge shall be recovered into the correct recovery cylinders. For appliances containing flammable refrigerants the system shall be purged with oxygen-free nitrogen to render the appliance safe for flammable refrigerants. This process may need to be repeated several times. Compressed air or oxygen shall not be used for purging refrigerant systems.
For appliances containing flammable refrigerants, refrigerants purging shall be achieved by breaking the vacuum in the system with oxygen-free nitrogen and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final oxygen- free nitrogen charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipe-work are to take place.
Ensure that the outlet for the vacuum pump is not close to any potential ignition sources and that
ventilation is available.
Charging procedures In addition to conventional charging procedures, the following requirements shall be followed.
Prior to recharging the system, it shall be pressure-tested with the appropriate purging gas. The system shall be leak-tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.
Decommissioning Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of recovered refrigerant. It is essential that electrical power is available before the task is commenced.
a) Become familiar with the equipment and its operation.
b) Isolate system electrically.
c) Before attempting the procedure, ensure that:
» mechanical handling equipment is available, if required, for handling refrigerant cylinders;
» all personal protective equipment is available and being used correctly;
» the recovery process is supervised at all times by a competent person;
» recovery equipment and cylinders conform to the appropriate standards.
d) Pump down refrigerant system, if possible.

e) If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
f) Start the recovery machine and operate in accordance with instructions.
g) Do not overfill cylinders (no more than 80 % volume liquid charge).
h) Do not exceed the maximum working pressure of the cylinder, even temporarily.
i) When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
j) Recovered refrigerant shall not be charged into another refrigerating system unless it has been cleaned and checked.
Labelling Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. For appliances containing flammable refrigerants, ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.
Recovery When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely.
When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure-relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of all appropriate refrigerants including, when applicable, flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant waste transfer note arranged. Do not mix refrigerants in recovery units and especially not in cylinders.
If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.
Häufige Probleme, wahrscheinliche Ursachen und Lösungen.
| Problem | Mögliche Ursache | Abhilfe | |
|---|---|---|---|
| The dehumidifier does not run. | • Power plug fell out. | • Insert the plug into socket. | p.10 |
| The dehumidifier does not run. | • Water tank full of water or place dat incorrect position. | • Drain the water tank and place it back in correctly. | p.10 |
| The dehumidifier does not run. | • The ambient temperatur eis lower than 5 °C or higher than 32 °C. | • Normal phenomenon. | p.10 |
| The dehumidification function is not effective. | • Room temperature or humiditiy too low. | • In dry seasons the dehumidification ability will reduce. | p.10 |
| The dehumidification function is not effective. | • Air outlet and inlet blocked. | • Clean up the object block the air outlet and inlet. | p.10 |
| Air is not blown out. | • Air filter blocked. | • Clean the air strainer. | p.10 |
| Noise is abnormal during operation. | • Appliance placed improperly so that i tis inclined or unstable. | • Place the appliance on a firm level place. | p.10 |
| Noise is abnormal during operation. | • Air strainer blocked. | • Clean the air strainer. | p.10 |
| Noise is abnormal during operation. | • „Tittering“ sound. | • The flowing sound of refrigerant, a normal phenomenon. | p.10 |
| Water leakage | • Connection of drainage pipe becomes loose. | • Fasten drainage pipe. | p.10 |
| Water leakage | • Drainage system is blocked. | • Remove obstacles and straighten out the waterpipe. | p.10 |
| Frosting occurs | • The ambient temperature is low and i tis in the state of waiting to defrost. | • It is a normal phenomenon and the appliance has the automatic defrosting function. | p.10 |