Quick Start Guide

Page 2 of the ProPlex FloppyDrive Digital DIN Rail Mount user manual — Setup
Seite 2 · Zum Vergrößern klicken
Seite 2

Setup

ProPlex DIN Rail devices use a standard Phoenix MSTB screw terminal connector in various pin configurations. Please refer to the wiring diagrams below for correct hook up of your ProPlex DIN Rail product.

ProPlex FloppyDrive Digital DIN Rail Mount — Setup diagram (page 2)
Abb. 3 · Setup

The ProPlex FloppyDrive Digital DIN Rail must operate at 24 VDC. It can drive a maximum of 15m of 12W per meter Firefly FloppyFlex Digital LED neon and can control a maximum of 120 pixels of RGB.

Addressing and mode selection is done via RDM protocol.

1. Connect the DC power (24V) to the power input located in the left top corner. The connector should be wired as follows:
ProPlex FloppyDrive Digital DIN Rail Mount — Setup diagram (page 2)
Abb. 4 · Setup
Page 3 of the ProPlex FloppyDrive Digital DIN Rail Mount user manual — Setup
Seite 3 · Zum Vergrößern klicken
Seite 3
2. Connect the DMX signal input to the DMX input located in the right top corner of the unit. The connector should be wired as follows:
ProPlex FloppyDrive Digital DIN Rail Mount — Setup diagram (page 3)
Abb. 5 · Setup

2.1 To pass DMX to another device, connect the DMX cable to the DMX Thru port located in the right top corner of the unit. The connector should be wired as follows:

ProPlex FloppyDrive Digital DIN Rail Mount — Setup diagram (page 3)
Abb. 6 · Setup
3. Connect the FloppyFlex Digital to the output connector of the FloppyDrive Digital DIN Rail.

The connectors should be wired as follows:

ProPlex FloppyDrive Digital DIN Rail Mount — Setup diagram (page 3)
Abb. 7 · Setup
Page 4 of the ProPlex FloppyDrive Digital DIN Rail Mount user manual — Connection Scheme for FloppyFlex Digital
Seite 4 · Zum Vergrößern klicken
Seite 4

Connection Scheme for FloppyFlex Digital

ProPlex FloppyDrive Digital DIN Rail Mount — Connection Scheme for FloppyFlex Digital diagram (page 4)
Abb. 8 · Connection Scheme for FloppyFlex Digital
Page 5 of the ProPlex FloppyDrive Digital DIN Rail Mount user manual — Connection scheme for DMX Thru-Port usage
Seite 5 · Zum Vergrößern klicken
Seite 5

Connection scheme for DMX Thru-Port usage

ProPlex FloppyDrive Digital DIN Rail Mount — Connection scheme for DMX Thru-Port usage diagram (page 5)
Abb. 9 · Connection scheme for DMX Thru-Port usage
Page 6 of the ProPlex FloppyDrive Digital DIN Rail Mount user manual — Dimensions and Connections
Seite 6 · Zum Vergrößern klicken
Seite 6

Dimensions and Connections

ProPlex FloppyDrive Digital DIN Rail Mount — Dimensions and Connections diagram (page 6)
Abb. 10 · Dimensions and Connections
ProPlex FloppyDrive Digital DIN Rail Mount — Dimensions and Connections diagram (page 6)
Abb. 11 · Dimensions and Connections
Page 7 of the ProPlex FloppyDrive Digital DIN Rail Mount user manual — LED Status Information
Seite 7 · Zum Vergrößern klicken
Seite 7

LED Status Information

ProPlex FloppyDrive Digital DIN Rail Mount — LED Status Information diagram (page 7)
Abb. 12 · LED Status Information

The Power LED has two states: ON and OFF.

  • ON: Unit is receiving power
  • OFF: Unit is not receiving power

The DMX input activity LED has two states: OFF and BLINKING YELLOW.

  • OFF: There is no active incoming DMX signal.
  • BLINKING YELLOW: There is an active incoming DMX signal. DMX values for FloppyFlex Digital output
ProPlex FloppyDrive Digital DIN Rail Mount — LED Status Information diagram (page 7)
Abb. 13 · LED Status Information
ChannelValueFunctionPixel numb. 1000 ↔ 255RED intensity 0% - 100%1 2000 ↔ 255GREEN intensity 0% - 100%1 3000 ↔ 255BLUE intensity 0% - 100%1 4000 ↔ 255RED intensity 0% - 100%2 5000 ↔ 255GREEN intensity 0% - 100%2 6000 ↔ 255BLUE intensity 0% - 100%2 ………… ………… ………… 358000 ↔ 255RED intensity 0% - 100%120 359000 ↔ 255GREEN intensity 0% - 100%120 360000 ↔ 255BLUE intensity 0% - 100%120
Page 8 of the ProPlex FloppyDrive Digital DIN Rail Mount user manual — LOS ANGELES +1 818.899.8818
Seite 8 · Zum Vergrößern klicken
Seite 8

CONTACT INFORMATION

LOS ANGELES HEADQUARTERS

527 Park Avenue | San Fernando, CA 91340, USA

Tel+1 818.899.8818 | Fax: +1 818.899.8813

sales@tmb.com

TMB 24/7 TECH SUPPORT

US/Canada+1.818.794.1286
Toll Free1.877.862.3833 (1.877.TMB.DUDE)

UK: +44 (0)20.8574.9739

Toll Free0800.652.5418

techsupport@tmb.com

LOS ANGELES +1 818.899.8818

LONDON +44 (0)20.8574.9700

NEW YORK +1 201.896.8600

BEIJING +86 10.8492.1587

CANADA +1 519.538.0888

ProPlex FloppyDrive Digital DIN Rail Mount — LOS ANGELES +1 818.899.8818 diagram (page 8)
Abb. 14

A full service company providing technical

support, customer service, and follow-up. Providing products and services for the industrial,

entertainment, installation, defense, broadcast, research, telecommunications, and signage industries.

Servicing the global market from offices in Los Angeles, London, New York, Toronto, and Beijing.

Frage zu ProPlex FloppyDrive Digital DIN Rail Mount stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu ProPlex FloppyDrive Digital DIN Rail Mount

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

ProPlex FloppyDrive Digital DIN Rail Mount PDF-Anleitung

8 Seiten·201 KB·Halterung·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…