Congratulations with the purchase of your dehumidifier. You have acquired a high quality
product which will give you many years of pleasure, if you use it responsibly. Please read
the user’s manual first in order to ensure the optimum life span of your dehumidifier. On
behalf of the manufacturer, we provide a two-year warranty on material- or manufacturing
defects.
Enjoy your dehumidifier.
PVG Holding B.V.
1 PLEASE READ THE USER’S MANUAL FIRST.
2 IF YOU HAVE ANY DOUBTS, CONSULT YOUR DEALER.
Dear Sir, Madam, · Yours sincerely, · Customer Service Department

A
B

F
G
H

Read this user manual carefully before using the appliance and keep it for future reference. Install this device only when it complies with local/national leg- islation, ordinances and standards. This product is intended to be used as a dehumidifier in residential houses and is only suitable for use in dry locations, in normal household conditions, indoors in living room, kitchen and garage. This unit is only suitable for earthed sockets, connection voltage 220-240 V. / ~50 Hz.

The electricity supply to the device must be checked by a recognised professional if you have any doubts regarding the compatibility.


Specific information regarding appliances with R 290 refrigerant gas.

Maintenance and repairs that require the assis- tance of other qualified personnel must be per- formed under the supervision of an individual specified in the use of flammable refrigerants.
Appliances shall be installed,operated and stored in a room with a floor area larger than 4 m2. The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
1 GENERAL INSTRUCTIONS This instruction manual is intended for use by individuals possessing adequate backgrounds of electrical, electronic, refrigerant and mechanical experience.
1.1 Checks to the area Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
1.2 Work procedure Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed.
1.3 General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
1.4 Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. nonsparking, adequately sealed or intrinsically safe.
1.5 Presence of fire extinguisher lf any hotwork is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.
1.6 No ignition sources No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to thesurrounding space. Prior to worktaking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed.
1.7 Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it extemally into the atmosphere.
1.8 Checks to the refrigeration equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. lf in doubt consult the manufacturer’s technical 4

2.2 Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc.
Ensure that apparatus is mounted securely.
Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications.
NOTE The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. lntrinsically safe components do not have to be isolated prior to working on them. 3 REPAIR TO INTRINSICALLY SAFE COMPONENTS Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted tor the equipment in use.
lntrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating.
Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak. 4 CABLING Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continua! vibration from sources such as compressors or fans. 5 DETECTION OF FLAMMABLE REFRIGERANTS Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame} shall not be used.

6 LEAK DETECTION METHODS The following leak detection methods are deemed acceptable for systems containing flammable refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need recalibration. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum} is confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipework. lf a leak is suspected, all open flames shall be removed/extinguished. lf a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves} in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process. 7 REMOVAL AND EVACUATION When breaking into the refrigerant circuit to make repairs - or for any other purpose - conventional procedures shall be used. However, it is important that best practice is followed since flammability is a consideration. The following procedure shall be adhered to: remove refrigerant; purge the circuit with inert gas; evacuate; purge again with inert gas; open the circuit by cutting or brazing.
The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be “flushed” with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task. Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipework are to take place. Ensure that the outlet tor the vacuum pump is not close to any ignition sources and !here is ventilation available. 8 CHARGING PROCEDURES In addition to conventional charging procedures, the following requirements shall be followed. Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them. Cylinders shall be kept upright. Ensure that the refrigeration system is earthed prior to charging the system with refrigerant. Label the system when charging is complete (if not already). Extreme care shall be taken not to overfill the refrigeration system. Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site. 9 DECOMMISSIONING Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. lt is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. lt is essential that 4 GB electrical power is available before the task is commenced. a) Become familiar with the equipment and its operation. b) lsolate system electrically. c) Before attempting the procedure ensure that: mechanical handling equipment is
available, if required, for handling refrigerant cylinders; d) All personal protective equipment is available and being used correctly; the
recovery process is supervised at all times by a competent person; e) recovery equipment and cylinders conform to the appropriate standards. f) Pump down refrigerant system, if possible. g) lf a vacuum is not possible, make a manifold so that refrigerant can be removed
from various parts of the system. h) Make sure that cylinder is situated on the scales before recovery takes place. i) Start the recovery machine and operate in accordance with manufacturer’s
instructions. j) Do not overfill cylinders. (No more than 80 % volume liquid charge).

k) Do not exceed the maximum working pressure of the cylinder, even temporarily. l) When the cylinders have been filled correctly and the process completed, make
sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off. m) Recovered refrigerant shall not be charged into another refrigeration system
unless it has been cleaned and checked. 10 LABELLING Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant. 11 RECOVERY When removing refrigerant from a system, either for servicing or decommissioning, il is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge are available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that il is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders.
lf compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric healing to the compressor body shall be employed to accelerate this process. When oil is drained from a system, il shall be carried out safely.

Respect the required distance of the device to walls and other objects.
humidity will be displayed with the defaults of continuous mode “CO”, and the
compressor will then start immediately for dehumidification with POWER indicator
lamp lit (when the compressor stops,it flashes).
degree, the wind speed is fixed.
20 cm · 20 cm

(continuous), “30%”, “50%”, “35%”, “40%”, “45%”, “50%” “85%”, “90%”,
“AU” (comfort), “CO” (continuous) cycle. The default mode is “CO”.
humidity, the indicator “Cº” being for temperature and “%” for humidity.
A. In the power-on state, press the TIMER key to set the timer for the scheduled
shutdown. In the off state, press the TIMER key to set the timer and when to start
the dehumidifier.
B. Regular time range: 01~24 hours, timing setting: 000102 232400 cycle.
C. When the timing is set to power on, the timing setting is completed and the timing
is displayed. When the timing is set to off, the timing setting is completed and the
humidity is displayed after 5 seconds.
After child lock is turned on, all button operations except child lock buttons cannot
be operated.
operation is completed 10S, all lights (including double 8) are all dimmed.
A. When “CO” (continuous) operation is set to dehumidify, the dehumidifier will
continue to operate regardless of the humidity level.
B. If the indoor humidity is higher than or equal to 3% or more of the set humidity,
the compressor and fan will run. The indicator light of the compressor will be on.
C. After the humidity in the room is dehumidified, when the humidity drops below
2% of the set humidity, the compressor is turned off and the dehumidification is
stopped. The indicator lamp (OK lamp) that reaches the humidity is on.
D. If the dehumidifier stops dehumidifying and the humidity in the room rises above
or equal to 3% or more of the set humidity, if the compressor has passed the
three-minute protection status, the compressor will start dehumidifying.
E. According to the above cycle operation, the indoor humidity can be maintained
at the set humidity.
A. Below 5°C at room temperature, the dehumidifier stops
B. 5 °C ≤ room temperature ≤ 20 °C, automatic selection set 60% humidity
C. 20°C
D. Room temperature> 27 °C, automatic selection set 50% humidity.
A. When this function is enabled, the dehumidifier will continue to operate
(compressor, fan operation) regardless of the humidity level when the “CO”
(continuous) operation dehumidifies.
B. The wind speed is locked at high speed and cannot be adjusted.
A. The compressor does not work.

B. The fan can choose two operating modes: high wind and low wind.
C. Humidity setting button cannot be pressed in fan mode
A. When the full water lasts for 3 seconds , the controller stops working and all
outputs are turned off. The full water indicator is on (FULL, the buzzer sounds 15
rings. Press any key, the bee The alarm will stop immediately.
B. When the full water fault is removed, the original machine’s operating status is
restored (the compressor must be protected by 3 minutes)
A. When it is in defrosting, the compressor is turned off, the fan is defrosted by high
winds, and the defrost indicator lights up (DEF).
B. When the room temperature is less than or equal to 16°C, the temperature of the
coil is not detected. According to the room temperature action, it is as follows:
Room temperature
When 5°C ≤ room temperature ≤ 12°C, the compressor is running for 30 minutes
and the defrost is stopped for 10 minutes.
When 12°C< room temperature ≤ 16°C, the compressor is running for 45 minutes
and the defrost is stopped for 10 minutes
C. When the room temperature is greater than 16°C, the temperature of the coil
is detected, and the operation is performed according to the temperature of
temperature is detected. If the coil temperature is ≤ 1°C, the defrosting is stopped
for 10 minutes.
A. Every time the boot compressor is allowed to start immediately.
B. After the compressor is shut down, start it again, with at least a 3-minute interval.
When the drainage tank is full, the tank full indicator light will turn on, the operation will
stop automatically and the buzzer will beep 15 times to alert the user, that the water need
to be emptied from the drainage tank.



be able to sense the water level so that it can not operate normally.

detergents, steel velvet, chemical treated dusting cloth, gasoline, benzene, thinner
or other solvents, because it may damage the water tank and cause water leakage.
tank is not placed, the full water sensor will still be activated, and the dehumidi-
fier will not work.

The dehumidifier has a continuous drainage hole, using a plastic tube (diameter 10mm)
inserted in partition drainage hole, then outgoing from the tank side. When the water
tank should be installed in place,and the drainage pipe straightened out, the water can be
drained from the machine through the drainage hole.



A. TO CLEAN THE BODY
1Wipe it with a soft damp cloth.

very dirty, use warm water and gentle detergent. Keep dry.



filter in place.

If the machine will not be used for a long period of time, take the following steps:
the dehumidifier to dry completely.
Check the following before contacting technical support:
Failure Potential causes of failure Solution
Is the power line properly con- nected??
Connect the plug and socket well.
Is the full water indicator light? (water tank full or not put in place)
The machine doesn't work.
Drain the water in the tank and put it in place.
Is the room temperature is above 35 degrees or under 5 degrees? The protection device is started and the machine cannot work.
Clean the filter screen according to the cleaning instructions of dehumidifier.
Is the filter blocked?
Dehumidification func- tion can not start.
Is the air inlet or outlet blocked? Remove the obstruction from the air inlet or outlet.
Clean the filter screen according to the cleaning instructions of dehumidifier.
Without wind Is the filter plugged?
Is the machine tilted? Move the machine to a flat, strong position.
It's noisy at work?
Clean the filter screen according to the cleaning instructions of dehumidifier.
Is the filter blocked?
E1 Code Coil sensor short circuit or open circuit
Check whether the line is loose or replace the coil sensor.
There is a two-year warranty on your dehumidifier from the date of purchase. All material


Power supply V / Hz / Ph 220-240/50/1 Dehumidifying capacity (moisture removal at 30ºC, 80%RH) L / 24h 25
Dehumidifying capacity (moisture removal at 27ºC, 60%RH) L / 24h 12.5
For rooms up to * m3/h 140 - 160
Dimensions (w x d x h) mm 371 x 251 x 595
* To be used as indication
Subject to change without prior notice.
Do not dispose of electrical appliances as unsorted municipal waste, use separate
collection facilities. Contact your local government for information regarding the
collection systems available. If electrical appliances are disposed of in landfills or
dumps, hazardous substances can leak into the groundwater and get into the
food chain, damaging your health and well-being. When replacing old appliances
with new once, the retailer is legally obligated to take back your old appliance for
disposal at least for free of charge.
This equipment contains R290 refrigerant in the amount as stated in the table
above. Do not vent R290 into atmosphere: R290, is a fluorinated greenhouse gas